• Title/Summary/Keyword: flat-plate structure

검색결과 198건 처리시간 0.028초

슬림형 바닥시스템을 이용한 고층 복합구조의 내진성능에 관한 해석적 연구 (Analysis of Seismic Performance of Slim Flat Plate System in High-rise Hybrid Structural System)

  • 하기주;박효선;박중현;최경렬;김대중;정재광
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.77-80
    • /
    • 2005
  • Recently the construction of high-rise hybrid type building is progressively increased as the social demands. It is significantly important factors such as economy, the safety of structure, and the flexibility of internal space. Therefore new hybrid structural system, using slim flat plate system, is also required to be attained the reduction of story height, the flexibility and efficient use of space. The most suitable structural system is ,with the economy and flexibility, flat plate system in high-rise hybrid type building. But it was focused in the seismic performance for high performance flat plate system in high-rise hybrid type building. Therefore, in the study, to develop the new flat-plate system with high ductile, durable, good performance for the applications. It was evaluated the seismic performance in the critical region of slab-column connection. And then high performance flat plate system, designed by the economy and safety, was developed as a new technique in the application of high-rise hybrid type building.

  • PDF

Unified equivalent frame method for flat plate slab structures under combined gravity and lateral loads - Part 2: verification

  • Choi, Seung-Ho;Lee, Deuck Hang;Oh, Jae-Yuel;Kim, Kang Su;Lee, Jae-Yeon;Shin, Myoungsu
    • Earthquakes and Structures
    • /
    • 제7권5호
    • /
    • pp.735-751
    • /
    • 2014
  • In the previous paper, authors proposed the unified equivalent frame method (UEFM) for the lateral behavior analysis of the flat plate structure subjected to the combined gravity and lateral loads, in which the rotations of torsional members were distributed to the equivalent column and the equivalent slab according to the relative ratio of gravity and lateral loads. In this paper, the lateral behavior of the multi-span flat plate structures under various levels of combined gravity and lateral loads were analyzed by the proposed UEFM, which were compared with test results as well as those estimated by existing models. In addition, to consider the stiffness degradation of the flat plate system after cracking, the stiffness reduction factors for torsional members were derived from the test results of the interior and exterior slab-column connection specimens, based on which the simplified nonlinear push-over analysis method for flat plate structures was proposed. The simplified nonlinear analysis method provided good agreements with test results and is considered to be very useful for the practical design of the flat plate structures under the combined gravity and lateral loads.

포스트 텐션 플랫 플레이트 해석을 위한 강성감소계수 (Stiffness Reduction Factor for Post-Tensioned Flat Plate Slabs)

  • 박영미;박진아;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.125-126
    • /
    • 2009
  • 유효보폭 모델은 횡하중하의 포스트 텐션(PT) 플랫 플레이트 골조 해석에 사용된다. PT 플랫 플레이트의 정확한 해석을 위해서 슬래브의 강성감소는 정확하게 평가되어야 한다. 이 목적을 위하여 본 연구는 기존 연구자들의 PT 플랫 플레이트 실험체를 수집하였으며. 반복적인 작업으로 실험체 강성에 수렴하는 유효보폭모델의 강성을 찾기 위하여 슬래브 폭을 감소시켰다. 이러한 데이터를 수집하여 비선형 회귀분석을 통하여 PT 플랫 플레이트의 강성 감소 계수식을 제안하였다.

  • PDF

Optimization of the Emitting Structure of Flat Fluorescent Lamps for LCD Backlight Applications

  • Park, Ji-Hee;Ko, Jae-Hyeon
    • Journal of the Optical Society of Korea
    • /
    • 제11권3호
    • /
    • pp.118-123
    • /
    • 2007
  • The emitting structure of multi-channel-type flat fluorescent lamps (FFLs) combined by a lenticular-lens-patterned diffuser plate was optimized by the ray tracing technique. The optimal parameters such as the distance between the channels of the FFL and the distance between the FFL and the diffuser plate were suggested from the viewpoint of the luminance uniformity. The best luminance uniformity, which was higher than 90%, was obtained at the channel distance of 4 mm and the distance of 12.5 mm between the FFL and the patterned diffuser plate.

Numerical study on effect of integrity reinforcement on punching shear of flat plate

  • Ahsan, Raquib;Zahura, Fatema T.
    • Computers and Concrete
    • /
    • 제20권6호
    • /
    • pp.731-738
    • /
    • 2017
  • Reinforced concrete flat plates consist of slabs supported directly on columns. The absence of beams makes these systems attractive due to advantages such as economical formwork, shorter construction time, less total building height with more clear space and architectural flexibility. Punching shear failure is usually the governing failure mode of flat plate structures. Punching failure is brittle in nature which induces more vulnerability to this type of structure. To analyze the flat plate behavior under punching shear, twelve finite element models of flat plate on a column with different parameters have been developed and verified with experimental results. The maximum range of variation of punching stress, obtained numerically, is within 10% of the experimental results. Additional finite element models have been developed to analyze the influence of integrity reinforcement, clear cover and column reinforcement. Variation of clear cover influences the punching capacity of flat plate. Proposed finite element model can be a substitute to mechanical model to understand the influence of clear cover. Variation of slab thickness along with column reinforcement has noteworthy impact on punching capacity. From the study it has been noted that integrity reinforcement can increase the punching capacity as much as 19 percent in terms of force and 101 percent in terms of deformation.

Stiffness values and static analysis of flat plate structures

  • Unluoglu, Esref
    • Structural Engineering and Mechanics
    • /
    • 제6권4호
    • /
    • pp.427-437
    • /
    • 1998
  • Flat plate constructions are structural systems which are directly placed on columns without any beams. Various solution methods have been introduced for the solution of flat plate structures under horizontal and vertical loads. In most of these solution methods, models comprising of one column and one plate have been studied. In other solutions, however, co-behavior of two reciprocal columns has been investigated. In this study, interrelations of all the columns on one storey have been examined. At the end of the study structure consisting of nine columns and four plates has been chosen as a model. Then unit moment has been successively applied to each of these columns and unit moments carried over the other columns have been found. By working out solutions far plates and columns varying in ratio, carry-over factors have been found and these factors given in tables. In addition, fixed-end moment factors on the columns arising due to vertical load were also calculated. Then citing slope-deflection equations to which these results could be applied, some examples of moment and horizontal equilibrium equations have been given.

2차유동이 평판후류의 난류구조에 미치는 영향 (Effects of Secondary Flow on the Turbulence Structure of a Flat Plate Wake)

  • 김형수;이준식;강신형
    • 대한기계학회논문집B
    • /
    • 제23권9호
    • /
    • pp.1073-1084
    • /
    • 1999
  • The effects of secondary flow on the structure of a turbulent wake generated by a flat plate was investigated experimentally. The secondary flow was induced In a $90^{\circ}$ curved duct in which the flat plate wake generator was installed. The wake generator was installed in such a way that the wake velocity gradient exists in the span wise direction of the curved duct. Measurements were made in the plane containing the mean radius of curvature where pressure gradient and curvature effects were small compared with the secondary flow effect. All six components of the Reynolds stresses were measured in the curved duct. Turbulence intensities in the curved wake are higher than those in the straight wake due to an increase of the turbulent kinetic energy production by the secondary flow. In the inner wake region, shear stress and strain in the plane containing the velocity gradient of the wake show opposite signs with respect to each other, so that eddy viscosity Is negative in this region. This indicates that gradient-diffusion type turbulence models are not appropriate to simulate this type of flow.

초음속 유동장 내 평판/cavity를 이용한 연료-공기 혼합의 실험적 연구 (Experimental Study on Fuel-Air Mixing Using Flat Plate/Cavity in Supersonic Flow)

  • 김정우;정은주;김채형;정인석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.319-322
    • /
    • 2006
  • 초음속 연소가 성공하려면 1 ms의 시간 안에 충분한 연료-공기 혼합이 이루어져야 한다. 본 실험은 마하 1.92유동에서 헬륨을 수직 분사하여 연료-공기 혼합이 어떻게 이루어지는지 살펴보았다. 평판과 공동 두 가지 모델로 실험을 수행하였고, 슐리렌 가시화를 통해 사진을 찍었다. 압력은 초음속 덕트 내에서 충격파가 어떻게 생성되는지에 영향이 많았고, 침투 거리는 J가 커질수록 두꺼워졌다. 공동이 있는 경우 평판일 때보다 침투 거리가 더 컸다.

  • PDF

절판 구조물의 해석을 위한 8절점 평면 첼 요소의 개발 (Development of 8-node Flat Shell Element for the Analysis of Folded Plate Structures)

  • 최창근;한인선
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.234-241
    • /
    • 1999
  • In this study, an improved 8-node flat shell element is presented for the analysis of shell structure, by combining 8-node membrane element with drilling degree-of-freedom and 8-node plate bending element based on the recently presented technique. Firstly, 8-node membrane element designated as CLM8 is presented in this paper. The element has drilling degree-of.freedom in addition to transitional degree-of-freedom. Therefore the element possesses 3 degrees-of-freedom per each node which as well as the improvement of the element behavior, permits an easy connection to other element with rotational degree-of -freedom. Secondly. 8-node flat shell element was composed by adding 8-node Mindlin plate bending element to the membrane element. The behavior of the introduced plate bending element is further improved by combined use of nonconforming displacement modes, selectively reduced integration scheme and assumed shear strain fields. The element passes in the patch test, doesn't show spurious mechanism and doesn't produce shear locking phenomena. Finally, Numerical examples are presented to show the performance of flat shell element developed in the present study.

  • PDF

고인성 복합섬유 모르타르를 이용한 플랫 플레이트 구조 슬래브-기둥 접합부의 전단성능 개선 (Improvement of Shear Performance for High Ductile Fiber-Reinforced Mortar Slab-Column Connection in Flat Plate Structural System)

  • 하기주;김윤용;신종학;양승혁;홍건호;김정수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.145-148
    • /
    • 2005
  • Recently the construction of high-rise reinforced concrete building is progressively increased as the social demands. It is significantly important factors such as economy, the safety of structure, and the flexibility of internal space. Therefore new structural system is also required to be attained the reduction of story height, the flexibility and efficient use of space. The most suitable structural system is with the economy and flexibility, flat plate slab system in high-rise reinforced concrete building. In this research, it was focused in the improvement of shear performance in the flat plate system using high ductile fiber reinforced mortar. It was evaluated the shear performance in the critical region of slab-column connection. The flat plate system, designed by the high performance and safety, was developed as a new technique in the application of high-rise R/C building.

  • PDF