• Title/Summary/Keyword: flashover

Search Result 321, Processing Time 0.029 seconds

Mathematical Modeling on AC Pollution Flashover Performance of Glass and Composite Insulator

  • Prakash, N.B.;Parvathavarthini, M.;Madavan, R.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1796-1803
    • /
    • 2015
  • While considering the current scenario, in this world power demand goes on increases day by day. Frequent power outages occur in high voltage transmission line due to the deprived performance of polluted insulators; this affects overall operation of power system and may indirectly impinge on the growth of production sector. Many researchers are keenly taking efforts to provide highly reliable and stable power to neediest. In this paper, A.C pollution flashover performance of disc type glass insulator and composite long rod insulators investigation under various artificial pollutions by varying Equivalent Salt Density Deposition (ESDD) levels. Here, we use different types of pollution methods like binding method, dipping method and spraying methods with different types of pollutants concentration. Based on dimensional analysis, four different Mathematical models have been developed to predict the A.C pollution Flashover Voltage (FOV) of insulators. Both the experimental and mathematically modeled results are compared; it's observed that mathematical model 3 yields better results.

Investigation on Flashover Development Mechanism of Polymeric Insulators by Time Frequency Analysis

  • Muniraj, C.;Krishnamoorthi, K.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1503-1511
    • /
    • 2013
  • This paper deals with the analysis of leakage current characteristics of silicone rubber insulator in order to develop a new condition monitoring tool to identify the flashover of outdoor insulators. In this work, laboratory based pollution performance tests are carried out on silicone rubber insulator under ac voltage at different pollution levels and relative humidity conditions with sodium chloride (NaCl) as a contaminant. Min-Norm spectral analysis is adopted to calculate the higher order harmonics and Signal Noise Ratio (SNR). Choi-Williams Distribution (CWD) function is employed to understand the time frequency characteristics of the leakage current signal. Reported results on silicone rubber insulators show that the flashover development process of outdoor polymer insulators could be identified from the higher order harmonics and signal noise ratio values of leakage current signals.

Influence of flame on flashover characteristics of model transmission line (모의 송전선로의 섬락특성에 미치는 화염의 영향)

  • Kim, I.S.;Kim, C.N.;Jee, S.W.;Lee, S.W.;Lee, K.S.;Lee, D.I.;Kim, L.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1738-1740
    • /
    • 2001
  • The occurrence of fires under transmission lines is responsible for a great number of power line outages. In this paper, the ac flashover voltages and the corona onset voltages of a model transmission line in the presence of flame were investigated. We found that the corona onset voltages and the flashover voltages were varied with the position of flames. Flashover voltages of vertical arranged electrodes with flame appeared to decrease 43[%] lower than those of same conditions with no flame.

  • PDF

A Study on the Characteristics of DC Flashover with Floating Metallic Objects in Unipolar Ion Field (불평등 전계중에 금속구 및 금속침의 부유 물체가 존재하는 경우의 Flashover특성)

  • Seok, B.Y.;Huh, G.D.;Kim, K.S.;Cho, J.S.;Park, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.469-471
    • /
    • 1995
  • This paper describes the effect of floating metallic object on do flashover characteristics in all gap producing unipolar ion flow field. Needle-to-plane electrodes of 120mm in gap length were used as the main gap electrode and the tested metallic objects were spheres with the radius of 2,10 and 15mm or needles from 5 to 40mm long. The characteristics of flashover voltage vs. location of the floating object are different completely with the shape of the floating metal and polarity of the applied voltage.

  • PDF

Electrical Flashover Characteristic Test by Gas Flames(I) (화염에 의한 전기적 섬락특성 실험(I))

  • Sohn, H.K.;Lee, H.K.;Han, H.J.;Park, I.P.;Han, S.W.;Kim, B.G.;Oh, H.H.;Choi, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.450-451
    • /
    • 2008
  • Most of the transmission lines in Korea pass through a mountains. The forest fire occurred in around the transmission lines make an accident such as flashover and faults in the power transmission lines. In spite of that risk, there are no research on the flashover characteristics by fires in electric discharge engineering in our country. Therefore, by studying flame's electrical conductivity, the paper recommended measures that can minimize transmission line's flashover accidents in the future, which can be caused by forest fire in a region where transmission lines pass through.

  • PDF

A Study on the Correlation of Analysis between Flashover and Smoke Production Rate in Building Structure (건축구조물에 있어서 플래시오버와 연기발생량의 상관관계 분석에 관한 연구)

  • Seo, Dong-Goo;Kim, Dong-Eun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.236-237
    • /
    • 2013
  • The fire safety design of performance is fire behavior inside buildings must be scientifically described and systemized as a theory, thereby allowing application to fire safety design of buildings. In this study, experiment of fire behavior according to disposition of combustibles were performed for correlation analysis between flashover and smoke production rate in building structure. As a result, smoke production rates is happened more than 80 m2/s in compartment(ISO 9705). Also, even if the fire load for flashover to if occur smoke did not, which confirmed that the delay time of occurrence.

  • PDF

A Flashover Characteristics Due to Flames (화염으로 인한 전기적 섬락특성 변화)

  • Sohn, H.K.;Lee, H.K.;Han, H.J.;Park, I.P.;Oh, H.H.;Min, B.W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.703-704
    • /
    • 2007
  • Most of the transmission lines in Korea pass through a mountains. The forest fire occurred in around the transmission lines make an accident such as flashover and faults in the power transmission lines. In spite of that risk, there are no research on the flashover characteristics by fires in electric discharge engineering in our country. This paper was mentioned about the relation between the flame and flashover characteristics. We were carried out simple test by using artificial flame generator and rod-plane or conductor-plane gaps. And we were summarized test results.

  • PDF

Electrical Characteristic of a Suspended Porcelain Insulator with a 154 kV Transmission Line (154 kV 송전선로 자기재 현수 애자의 전기적 특성 규명에 관한 연구)

  • Jeon, Seongho;Choi, In-Hyuk;Kim, Taeyong;Lee, Youn-Jung;Koo, Ja-Bin;Son, Ju-Am;Yi, Junsin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.1
    • /
    • pp.56-59
    • /
    • 2020
  • Porcelain insulators are typically exposed to surface discharge and lightning impulse in service. This study investigates the insulation characteristics of the external and internal discharges of a porcelain insulator with respect to its flashover for a 154 kV transmission line. The experiments are also conducted using a wet flashover test and an impulse test based on the external discharge and the internal penetration, to classify the flashover voltage-time curve of the porcelain insulator. When an impulse with a strength of 2,500 kV/㎲ was applied three times to 6.5 mm ceramic samples, electrical penetration of approximately 70% occurred. The impulse experiment confirmed that the electrical penetration inside the porcelain insulator coincided with the area where the electric field was concentrated. The wet flashover voltage test revealed that the flashover threshold voltage increases by approximately 7% after cleaning of the surface.

A Study of Horizontal Surface Discharge Characteristics for Dew-Point of Dry-Air and Materials of Solid Insulator in Quasi-Uniform Field (Dry Air 중의 준평등전계에서 노점과 고체절연물 재질에 따른 수평연면방전 특성 연구)

  • Kang, Byoung-Chil;Seok, Jeong-Hoo;Min, Gyeong-Jun;Bae, Sungwoo;Lee, Kwang-Sik;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.64-69
    • /
    • 2015
  • This study investigates the Horizontal surface discharge characteristics of solid insulators by varying their materials, and the dew-point of dry-air. The methodology of this study is that a quasi-uniform field is first applied to a test chamber. Then, the chamber is filled with dry-air as an insulation gas which pressure is varied from 1 to 6atm while applying an AC voltage to the chamber. The used solid insulators are teflon, polyethlene and polyurethane. As the dew-point is lower and the pressure of dry-air is higher, the flashover voltage of all solid insulators increases more. When each characteristic of the solid insulators is compared under the same gas pressure, the flashover voltage of teflon is the highest. Then, the flashover voltage of polyethlene is higher than that of polyurethane. Moreover, it is observed that the flashover voltage increases as the horizontal distance between the electrodes of each solid insulator become larger, respectively. However, as the pressure is increased, flashover voltage of the solid insulators is saturated. Therefore, selection of cost-effective insulation is needed in order to appropriate pressure.

Flashover Characteristics of the Horizontal Air Gaps Caused by Combustion Flames (연소화염에 의한 수평배치 공기갭의 섬락전압 특성)

  • 김인식;김이국;김충년;지승욱;이상우;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.27-34
    • /
    • 2002
  • In this paper, characteristics of the ac and dc flashover voltage in the horizontal air gap of a needle-needle electrode system were investigated when the combustion flame was present near the high-voltage electrode. In order to examine the flashover phenomena and the corona inception voltages caused by flame we measured the voltage and current waveforms when the corona and the flashover was occurred. We also observed, as increasing the applied voltages, the deflection or fluctuation phenomena in the shape of flames caused by the corona wind and the coulomb's force. As the results of an experimental investigation, we found that the reduction of flashover voltages, in comparison with the no-flame case, are 62.7[%] for k=1.0, 34.2[%] for h=5[cm], 27.3[%] for h=7[cm] and 21.4[%] for h=9[cm] when ac voltage is applied.