• Title/Summary/Keyword: flank approach

Search Result 25, Processing Time 0.028 seconds

Comparison of Paramedian and Flank Approaches for Abdominal Unilateral Cryptorchidectomy in Korean Native Calves (한우에서 복강 내 편측성 잠복고환 제거를 위한 부정중선 및 겸부 접근의 비교)

  • Jeong, Jae-Kwan;Baik, Young-Chul;Kang, Hyun-Gu;Kim, Ill-Hwa
    • Journal of Veterinary Clinics
    • /
    • v.30 no.1
    • /
    • pp.66-70
    • /
    • 2013
  • This report compared paramedian and flank approaches for the effective removal of abdominal unilateral cryptorchidism in calves. Two Korean native calves of approximately 300 kg in body weight, which had undergone the removal of a testis from the scrotum, were diagnosed as having abdominal unilateral (left) cryptorchidism by rectal palpation. One calf was administered with xylazine (0.2 mg/kg, IV) and was restrained in the dorsal recumbency position on the ground of barn for the paramedian approach, while the other calf was sedated with xylazine (0.03 mg/kg, IV) and restrained in the standing position for a flank approach. For the two calves, 2% lidocaine was administered by local infiltration, along the proposed incision line. Following incisions of the skin, muscle and peritoneum, the testis, which was located between the left kidney and inguinal canal, was grasped, exteriorized out of the abdominal cavity and detached from the gubernaculum testis. Then spermatic cord was ligated and cut. Finally, the testis was removed. An assistant was required to restraint a calf in dorsal recumbency for paramedian approach, and cryptorchidectomy was carried out with operator in a rather uncomfortable squatting posture, while restraint was rather simple and cryptorchidectomy was proceeded with operator in a standing posture where the flank approach was taken. During surgery, the gubernaculum testis was more strained during pulling the testis in the flank approach than in the paramedian approach, as the distance between incision site and the gubernaculum testis was greater in the flank approach than that in the paramedian approach. On the other hand, intra-abdominal pressure was greater in the paramedian approach than in the flank approach during surgery. The elapsed time between restraint and the end of surgery was 10 min shorter where the flank approach (35 min) was taken, than where the paramedian approach (45 min) was taken. In conclusion, this case study demonstrated that the flank approach might be more convenient than the paramedian approach for abdominal unilateral cryptorchidectomy in calves.

이미지 프로세싱을 위한 드릴 마모측정에 관한 연구

  • 양승배;김영일;유봉환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.298-301
    • /
    • 1992
  • A digital image processing approach has been adopted to measure the flank wear area, which is very difficult to measure using conventional techniques. Automatic thresholding of the gray-level values of an image is very useful in automated analysis of image. 1-D entropy thresholding technique is used for image processing and analysis of the flank wear area. This strategy provides more information about drill wear conditions and should therefore have a higher reliability than previous methods. This study calulated quantitatively the flank were area of drill by computer program.

Comparison of Ventral Midline and Right Flank Approaches of Ovariohysterectomy in Bitches

  • Ishwor Dhakal;Bharata Regmi;Bablu Thakur;Ishwari Tiwari;Shraddha Tiwari;Yeonsu Oh;Manoj K. Shah
    • Journal of Veterinary Clinics
    • /
    • v.40 no.1
    • /
    • pp.25-30
    • /
    • 2023
  • The ventral midline approach (VMA) and right flank approach (RFA) are common procedures for the sterilization of bitches. This study compared the different parameters viz. total duration of surgery, recovery time, and length of the incision as well as body temperature, heart rate, respiration rate, and SpO2 in each approach. Twenty (20) bitches were divided randomly for the RFA and VMA. Meloxicam (0.2 mg/kg) was administered subcutaneously half an hour before the induction to provide preemptive analgesia. Diazepam and ketamine were administered intravenously at dose rates of 0.25 mg/kg and 2.5 mg/kg, and 0.17 mg/kg and 3.33 mg/kg, respectively to produce and maintain anesthesia. Each parameter was recorded at the pre-operative, operative and post-operative times. The average duration of surgery and length of incision of RFA (16.1 ± 5.13 min and 2.44 ± 0.83 cm) were significantly lower (p < 0.05) than the VMA (21.3 ± 5.48 min and 3.53 ± 0.7 cm). The operated bitches showed hypothermia (p < 0.05) at 1 hour compared to baseline and 24 hours of surgery. Heart and respiration rates increased significantly (p < 0.05) during traction and severing of ovarian ligaments in bitches within the RFA group, but there was no significant difference within VMA approaches. The sedation score was significantly higher (p < 0.05) at 1 hour after surgery in both approaches. Based on the duration of surgery and length of incision RFA approach was quick and minimal skin wound. Further studies on bitches considering molecular investigations of surgical stress are imperative.

A Study on Tool Wear Diagnosis by Measuring Spindle Displacement (주축 변위 측정을 통한 공구 마모 진단에 관한 연구)

  • 김진현;김일해;장동영;한동철
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.1
    • /
    • pp.222-228
    • /
    • 2003
  • A reliable tool wear monitoring technique is the one of important aspects for achieving an integrated and self-adjusting manufacturing system. In this paper, a tool wear estimation approach for turning is proposed. This approach uses the model of cutting force, spindle displacement and their relation. A series of experiments were conducted by designing experimental techniques to determine the relationship between flank wear and cutting force coefficient as well as cutting parameters such as cutting speed, depth of cut and feed. The proposed model performance has shown that the spindle displacement model predicts tool wear with high accuracy and spindle displacement signal is possible to replace cutting force signal.

A Study on Tool Wear Diagnosis by Measuring Spindle Displacement (주축 변위 측정을 통한 공구 마모 진단에 관한 연구)

  • 김진현;김일해;장동영;한동철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.459-464
    • /
    • 2001
  • A reliable tool wear monitoring technique is the one of important aspects for achieving an integrated and self-adjusting manufacturing system. In this paper, a tool wear estimation approach for turning is proposed. This approach uses the model of cutting force, spindle displacement and their relation. A series of experiments were conducted by designing experimental techniques to determine the relationship between flank wear and cutting force coefficient as well as cutting parameters such as cutting speed, depth of cut and feed. The proposed model performance has shown that the spindle displacement model predicts tool wear with high accuracy and spindle displacement signal is possible to replace cutting force signal.

  • PDF

A Study on the Cutting Tool Wear by Time Series Approach (시계열분석 방법 에 의한 절삭공구 의 마멸 에 관한 연구)

  • 김광준;황홍연
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.5
    • /
    • pp.450-461
    • /
    • 1984
  • A new indirect tool wear sensing technique is proposed using time series analysis. The acceleration measured on the tool post in the vertical direction during turning is sampled with uniform interval, and fitted following the ARMA modeling procedures. Various signal characteristics are observed in respect with the progress of flank wear. From those observations it is believed that; *The variance of the signal is approximately proportional to the increase of flank wear. *The absolute power of a dynamic mode decreases in the beginning of cutting until the maximum flank wear increases up to 0.4-0.5mm, and then increases. *The other characteristics are not so much related to the tool wear as the signal variance and the absolute power of a dynamic mode. Hence, the absolute power of a dynamic mode seems to be a good factor for the indication of tool-change time regardless of tool material or cutting conditions.

Dual repair of traumatic flank hernia using laparoscopic and open approaches: a case report

  • Heo, Yoonjung;Kim, Dong Hun
    • Journal of Trauma and Injury
    • /
    • v.35 no.1
    • /
    • pp.46-50
    • /
    • 2022
  • Traumatic flank hernia (TFH) is rare and prone to recurrence, which makes appropriate treatment challenging. No current guidelines define the optimal timing and method of repair. Meanwhile, recent advances in laparoscopic techniques are reshaping the options for the treatment of TFH. A dual approach that utilizes both laparoscopic and open methods has not previously been reported. Herein, we present the successful treatment of TFH after blunt trauma. A 46-year-old male patient underwent elective herniorrhaphy on hospital day 3, in which laparoscopic implantation of a sublay mesh and extracorporeal implantation of an onlay mesh were performed. Such techniques may be appropriate and result in feasible outcomes in hemodynamically stable patients with large TFH who are strongly suspected of having bowel herniation or concomitant intraperitoneal injuries. Larger studies are needed to assess the long-term results.

A Study on the Wear of Ceramic Tool in Finish Machining of STD11 Steel (STD11강의 다듬질절삭에 의한 세라믹공구의 마멸에 관한 연구)

  • 김광래
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.4 no.2
    • /
    • pp.46-53
    • /
    • 1995
  • In this study, Wear of a ceramic cutting tool for hardened STD11 steel was investigated. Under the finish machining condition. DOC notch wear of a ceramic cutting tool was mostly occurred earlier than flank and crater wear were proceeded. The relations of DOC notch wear, which was characteristically produced at the beginning of cutting. to cutting speed, feed, depth of cut, and nose radius of a ceramic cutting tool were examined. Effective approach angle, which is a function of cutting conditions, and boundary area were suggested, and then the influence of those was investigated, The following conclusions were obtained: (1)as cutting speed was increasing. DOC notch wear was decreasing (2) the cutting condition that magnitude of slendermess ratio was made small, was favorable for DOC notch wear, (3) as depth of cut was smaller, the influence of feed on DOC notch wear was also smaller, (4) DOC notch wear was mainly influenced by effective approach angle, but by boundary area in the range of low feed.

  • PDF

Mechanistic Analysis Modeling for the 3-D Chip Formation Process (3-D 칩생성과정의 역학적 해석 모델링)

  • Kim, Gyeong-U;Kim, U-Sun;Kim, Dong-Hyeon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.12
    • /
    • pp.163-168
    • /
    • 2000
  • Once the chip has developed a mixed mode of side-curl and up-curl, it would generally curl to strike the tool flank. The development of the bending stresses and sheat in the chip would ultimately lead to chip failure. This paper approach this problem from a mechanics-based approach, by treating the chip as a 3-D elastic curved beam, and applying appropriate constraints and forces. The expressions for bending, shear and direct stresses are developed through an energy-based criterion. The location of the maximum stresses is also identified and explained for simulated test conditions.

  • PDF

A Study on the Surface Roughness Behavior of Reactor Vessel Stud Holes in APR1400 Nuclear Power Plants (APR1400 원자로 용기 스터드 홀의 표면거칠기 거동에 관한 연구)

  • Kim, Dong Il;Kim, Chang Hun;Moon, Young Jun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.1
    • /
    • pp.62-70
    • /
    • 2019
  • The APR1400 reactor may be operated for a long time under high temperature and pressure conditions, causing damage to the stud holes and causing stud bolts and holes to stick. The present practice is to manually remove the anti-sticking agent and foreign matter remaining in the APR1400 reactor stud hole and to visually check the surface condition of the thread to check the damage status of the threads. In the case of the APR1400 reactor stud holes, manually cleaning the threads increases the risk of radiation exposure and operator's fatigue. To avoid this, the autonomous mobile robot is used to automatically clean the reactor stud holes. The purpose of this study is to optimize the cleaning performance of the mobile robot by looking at the behavior of the surface roughness of the stud surface cleaned by the brush attached to the mobile robot due to changes in brush material, thickness of wire, and rotation speed. A microscopic approach to the surface roughness of the flank is needed to investigate the effects of the newly proposed brush of the autonomous mobile robot on the thread holes. According to this experiment, it is reasonable to use STS brush rather than Carbon one. Optimal operating conditions are derived and the safety of APR1400 reactor stud holes maintenance can be improved.