• Title/Summary/Keyword: flame liftoff

Search Result 55, Processing Time 0.024 seconds

Characteristics of Interacting Lifted Flames (상호작용하는 부상화염의 특성에 관한 연구)

  • Lee, Seung;Lee, Byeong-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.461-466
    • /
    • 2001
  • The characteristics of nonpremixed interacting flames are investigated in the parameter of nozzle configuration and nozzle separation distane, s. Three nozzle arrangements - diamond 4 nozzle, linear 5 nozzle and cross 5 nozzle- are used. When s is about 10 nozzle diameter, flames lift from the nozzle at the highest fuel flowrate compared with the other s cases. Normally flames are extinguished at the lifted states. Flowrates when blowout occurs are affected by the nozzle configuration, nozzle seperation distance. Blowout flowrates for the diamond- or cross-shaped nozzle cases are parabolic function of s. For 5 cross nozzle case, flames extinguished at 3.3 times higher flowrate than that of single equivalent area nozzle. Turbulent liftoff heights are not function of flowrates for these cases.

Non-Reacting Flow Structure of a Low Swirl Combustor with respect to Inlet Velocities (저선회 연소기의 입구 속도에 따른 비반응 유동구조 분석)

  • Jeong, Hwanghui;Lee, Bok Jik;Lee, Keeman
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.56-63
    • /
    • 2018
  • In low swirl combustors the flame is lifted above the nozzle to achieve balance between the flame speed and velocity field at the exit of the nozzle. Characterization of the flame liftoff height is important because it affects the stability of the combustor and degradation of the nozzle material. In experiments, a counter-intuitive trend of flame liftoff heights with respect to inlet velocities was observed. To elucidate the complicated flow field in a low swirl combustor having swirl vanes and a turbulence generator, a series of numerical simulations of non-reacting flows was conducted by varying the inlet velocity. The flow structures at the exit of the nozzle with respect to the inlet velocities are investigated to support the observation in the experiments.

Effect of Hydrogen Addition on Autoignited Methane Lifted Flames (자발화된 메탄 부상화염에 대한 수소 첨가의 영향)

  • Choi, Byung-Chul;Chung, Suk-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.75-81
    • /
    • 2012
  • Autoignited lifted flames in laminar jets with hydrogen-enriched methane fuels have been investigated experimentally in heated coflow air. The results showed that the autoignited lifted flame of the methane/hydrogen mixture, which had an initial temperature over 920 K, the threshold temperature for autoignition in methane jets, exhibited features typical of either a tribrachial edge or mild combustion depending on fuel mole fraction and the liftoff height increased with jet velocity. The liftoff height in the hydrogen-assisted autoignition regime was dependent on the square of the adiabatic ignition delay time for the addition of small amounts of hydrogen, as was the case for pure methane jets. When the initial temperature was below 920 K, where the methane fuel did not show autoignition behavior, the flame was autoignited by the addition of hydrogen, which is an ignition improver. The liftoff height demonstrated a unique feature in that it decreased nonlinearly as the jet velocity increased. The differential diffusion of hydrogen is expected to play a crucial role in the decrease in the liftoff height with increasing jet velocity.

Characteristics of Laminar Lifted Flames in Coflow Jet with Various Coflow Velocities (동축류 제트에서 동축류 속도에 따른 층류 부상화염의 특성 연구)

  • Lee, S.J.;Kim, K.N.;Won, S.H.;Chung, S.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.21-26
    • /
    • 2004
  • Characteristics of laminar lifted names in coflow jet with various coflow velocities have been studied experimently. USlI1g the fuel nozzle with d=0.254 for the pure propane, liftoff heights are fitted by using power equation with jet velocity. As coflow velocity increases up to 60 cm/s powers of fitting equation steeply decrease. From the result of numerical analysis using the FLUENT, the stoichiometry contour and the axial velocity nondimensionalized by initial jet velocity along the stoichiometry contour are changed with variations of coflow velocities, The change of axial velocity along stoichiometric contour is more sensitive than that of stoichiometric contour, For this reason, powers of fitting equation for liftoff height with jet velocity decreases with the increase of coflow velocity. Using the fuel nozzle with d=4,35 mm for the highly diluted propane by nitrogen, the liftoff height increases with the increase of coflow velocity when coflow velocity is less than the maximum value of initial jet velocity. But when coflow velocity is faster than that, the liftoff height decreases with the increase of coflow velocity.

  • PDF

Lifted Flames in Laminar Coflow Jets of Propane (층류 동축류 제트에서의 프로판 부상 화염에 관한 실험적 연구)

  • Lee, J.;Won, S.H.;Jin, S.H.;Chung, S.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.61-67
    • /
    • 2002
  • Characteristics of lifted flames in axisymmetric laminar coflow jets have been investigated experimentally. Approximate equations for velocity and concentration with virtual origins have been proposed to analyze the behavior of flames in coflow jets. Measuring Rayleigh intensity to investigate the concentration field. proposed approximate equations were confirmed. By using the results of OH PLIF, direct photography and Rayleigh scattering measurement, it is shown that the locations of maximum intensity in direct photography coincide with the tribrachial points in axisymmetric jets and the tribrachial points travel on the stoichiometric contour. For coflow jets, the experimental results of liftoff height have been successfully correlated with nozzle exit velocity using predicted behavior from proposed approximated equations. These results substantiate the stabilization mechanism in coflow jet is based on the balance between flame propagation speed and axial flow velocity, same as for the free jets.

  • PDF

Nitrogen Dilution Effects on Liftoff Flame Stability in Non-premixed Turbulent Hydrogen Jet with Coaxial Air (질소희석이 부상된 수소 난류확산화염의 화염안정성에 미치는 영향)

  • Oh, Jeong-Seog;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.393-396
    • /
    • 2008
  • The study of nitrogen dilution effect on flame stability was experimentally investigated in non-premixed turbulent lifted hydrogen jet with coaxial air. hydrogen gas was used as a fuel and coaxial air was injected to make flame liftoff. And both of the fuel jet and coaxial air velocity were fixed as $u_F$=200 m/s and $u_A$=16 m/s, while nitrogen diluents mole fraction was varied from 0 to 0.2. For the analysis of flame structure and flame stabilization mechanism, the simultaneous measurement of PIV/OH PLIF had been performed. It was found that the turbulent flame propagation velocity increased as decreasing of nitrogen mole fraction. We concluded that the turbulent flame propagation velocity was expressed as a function of turbulent intensity, even though the mole fraction of nitrogen diluents gas was changed.

  • PDF

Study on the Turbulent Edge Propagation Speed of a Lifted Diffusion Flame in Turbulent Mixing Layer (난류 혼합층 확산화염에서 부상선단의 난류전파속도에 대한 연구)

  • Kim, Jun-Hong;Chung, S.H.;Ahn, K.Y.;Kim, J.S.
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.55-61
    • /
    • 2004
  • Leading front of a lifted diffusion flame in turbulent mixing layer was investigated in order to find a appropriate definition of the turbulent edge propagation speed. The turbulent lifted diffusion flame was simulated by employing the flame hole dynamics combined with level-set method which yields a temporally evolving turbulent extinction process. By tracing the leading front locations of the temporal flame edges, temporal variations of the liftoff height, local flow velocity, and edge propagation speed at the leading front were investigated and they demonstrated the flame-stabilization condition of the turbulent lifted flame. Finally, a turbulent edge propagation speed was defined and its temporal variation from the simulation was discussed.

  • PDF

The Stability of Turbulent Interacting Flames (다수 난류 비예혼합 화염의 상호작용에 관한 연구)

  • Kim, Jin-Sun;Lee, Byeong-Jun
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.453-458
    • /
    • 2001
  • The stability of turbulent nonpremixed interacting flames is investigated in terms of nozzle configuration shapes which depend on the existence of the center nozzles. Six nozzle arrangements which are cross 4, 5, 8, 9, square 8 and circular 8 nozzles are used for the experiment. Those are arranged to see the effect of the center nozzle out of multi-nozzle. There are many parameters that affect flame stability in multi-nozzle flame such as nozzle separation distance, fuel flowrates and nozzle configuration, but the most important factor is the existence of nozzles in the center area from the nozzle arrangement. As the number of nozzle in the area is reduced, more air can be entrained into the center of flame base and then tag flame is formed. In the case of circular 8 nozzles, blowout flowrates are above 5.4 times compared with that of single equivalent area nozzle.

  • PDF

A Transitional Behavior of a Premixed Flame and a Triple Flame in a Lifted Flame(II) (부상화염에서 예혼합화염과 삼지화염의 천이적 거동(II))

  • Jang Jun Young;Kim Tae Kwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.3 s.234
    • /
    • pp.376-383
    • /
    • 2005
  • In the paper we investigate characteristics of a transitional behavior from a premixed flame to a triple flame in a lifted flame according to the change of equivalence ratio. In previous study, we showed that the stabilized laminar lifted flame regime is categorized by regimes of premixed flame, triple flame and critical flame. A gas-chromatograph is used to measure concentration field, a smoke-wire system is used to measure streak line, and a PIV system is used to measure velocity field in lifted flame. In the visualization experiment of smoke wire, the flow divergence and redirection reappeared in premixed flame as well as triple flame. Thus we cannot express the flame front of lifted flame has a behavior of triple flame with only flow divergence and redirection. In PIV measurement, flow velocity for those three flames has minimum value at the tip of flame front. To differentiate triple flame and premixed flame, $\Phi$ value of partially premixed fraction is employed. The partially premixed fraction $\Phi$ was constant in premixed flame. In critical flame small gradient appears over the whole regime. In triple flame, typical diffusion flame shape is obtained as parabolic distribution type due to diffusion flame trailing.

Characteristics of Autoignited Laminar Lifted Flames in Heated Coflow Jets of Carbon Monoxide/Hydrogen Mixtures (일산화탄소/수소 혼합기의 가열된 동축류 제트에서 자발화된 층류 부상화염의 특성)

  • Choi, Byung-Chul;Chung, Suk-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.639-646
    • /
    • 2012
  • The characteristics of autoignited lifted flames in laminar jets of carbon monoxide/hydrogen fuels have been investigated experimentally in heated coflow air. In result, as the jet velocity increased, the blowoff was directly occurred from the nozzle-attached flame without experiencing a stabilized lifted flame, in the non-autoignited regime. In the autoignited regime, the autoignited lifted flame of carbon monoxide diluted by nitrogen was affected by the water vapor content in the compressed air oxidizer, as evidenced by the variation of the ignition delay time estimated by numerical calculation. In particular, in the autoignition regime at low temperatures with added hydrogen, the liftoff height of the autoignited lifted flames decreased and then increased as the jet velocity increased. Based on the mechanism in which the autoignited laminar lifted flame is stabilized by ignition delay time, the liftoff height can be influenced not only by the heat loss, but also by the preferential diffusion between momentum and mass diffusion in fuel jets during the autoignition process.