• Title/Summary/Keyword: fixtures

Search Result 384, Processing Time 0.026 seconds

Proposal of VMD for a Footwear Shop at Department Stores - Focused on a Footwear Shop for Women at a "H" Department Store -

  • Lee, Mi-Young;Kim, Soon-Ku
    • Journal of Fashion Business
    • /
    • v.6 no.3
    • /
    • pp.28-40
    • /
    • 2002
  • For modern man and woman, footwear is considered a fashion for expressing oneself, and not merely a protective tool for the feet. The purpose of this research is to increase the effect of sales promotional activities by emphasizing product image and by enhancing sales environment. Towards this end, this research focuses on the study of environment at footwear stores that meet the challenges incurred by the changing lifestyles of consumers and the ensuing dynamics of the society in general. Research is based on an in-depth, thorough study of the previous research works and entails examining theoretical background and the concept of Visual Merchandising Display (VMD). Research will focus on the analysis of current situation at footwear stores located in department store based on material research on footwear stores and theoretical examination. Research on the current situation of footwear stores at department store will be conducted from the VMD perspective. In the end, this research paper will make suggestions on the VMD measures for footwear stores with the aim of increasing sales by satisfying consumers' sensibility and purchasing desire. Suggestions will be made based on the results of the research. -Study of current VMD status per fixture centered on 18 brands at department store -Suggestions for VMD at footwear stores based on the survey results of customer purchasing behavior This research intends to develop structured VMD methodology for footwear stores based on the research centered on VMD research of footwear stores at department store. Significance of this research lies in its aim to contribute to the sales increase, no matter how trivial it might be. Going a step further, this research work could be considered one of the foundations for defining the role of VMD methodology at footwear stores. Suggested results are as follows. (1) Need to cast away from simple, one-dimensional type of display method at footwear stores and transform into product image oriented VMD (2) Need to highlight product image by fully leveraging props and by developing footwear display methods that are suitable for different types of fixtures (3) Need to stabilize VMD by developing footwear manual that enables efficient management by store operator.

Interaction effects of pen environment and sex on behavior, skin lesions and physiology of Windsnyer pigs

  • Mkwanazi, Mbusiseni Vusumuzi;Kanengoni, Arnold Tapera;Chimonyo, Michael
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.3
    • /
    • pp.452-458
    • /
    • 2019
  • Objective: The study was carried to determine the interaction effects of pen enrichment and sex on behavioral activities, skin lesions and physiology of Windsnyer pigs. Methods: Forty-eight growing Windsnyer pigs of both sex, with an average initial body weight of 21.6 (${\pm}9.01$) kg were used. Four pigs were randomly assigned to either enriched or barren pens at a stocking density of $0.35m^2/pig$. Enriched pens contained 2 L bottles filled with stones and suspended at head level on ropes stretching across the pens. In addition, two plastic balls (90 mm in diameter) and 500 mL bottles (235 mm long) were placed on the floor of each enriched pen. Results: Pigs in barren environments had higher heart rates (p<0.001) than those in enriched pens. There was an interaction of pen environment and sex on rectal temperature (p<0.001). Females in enriched pens had higher rectal temperatures (p<0.05) than females in barren pens. There was no interaction of pen environment and sex on time spent eating and drinking (p>0.05). Time spent bullying was influenced (p<0.05) by pen environment and sex. Female pigs in barren environment spent more time on bullying than females in enriched pens. There was an interaction of pen environment and sex on time spent lying down and walking (p<0.05). Female pigs in enriched pens spent more time lying down than females in barren pens. Males in barren pens spent more time walking than males in enriched pens while no effect of pen environment was observed in females. There was an interaction of pen environment and sex on the number of skin lesions in the head, neck and shoulder region and other parts of the body (p<0.05). Conclusion: It was concluded that pen enrichment reduced the number of skin lesions and anti-social behaviors, especially for female pigs. There is a need, therefore of housing indigenous pigs under confinement.

A retrospective randomized study of success rates according to abutment selection in DENTIS submerged implant with an internal hex connection (DENTIS 내부연결형 서브머지드 임플란트에서 지대주 선택에 따른 성공률의 후향적 연구)

  • Kim, Eun-Hee;Lee, Joeng-Eun;Hwang, Hee-Seong;Kim, Chul-Hoon;Kim, Jung-Han;Kim, Bok-Joo
    • The Journal of the Korean dental association
    • /
    • v.56 no.11
    • /
    • pp.605-614
    • /
    • 2018
  • PURPOSE. The purpose of this study is to determine the efficacy of the DENTIS submerged-type implant with an internal hex connection and to build corresponding abutment-selection criteria. MATERIAL AND METHODS. A total of 204 patients received submerged implant fixtures with an internal hex connection at the Dong-A University Hospital Dental clinic in Busan from January 2013 and May 2016. Three specific abutments, UCLA abutments, customized abutments, ready-made abutments, were randomly selected. Implant success was defined as the basis of the International Congress of Oral Implantologists(ICOI, 2007) criteria. The relationship between the implant success rate and the abutment factor was analyzed using the Kruskal-Wallis test(P<.05). RESULTS. A total of 508 implants were placed in 204 patients. After a mean observation period of 38.6 months, 493 out of 508 implants were in normal function, yielding an overall success rate of 97.05%. A total of 15 implants failed: 10 in the maxillary molar area, 4 in the mandibular molar area, and 1 in the mandibular incisal area. All of the implant failures occurred in a single-implant prosthesis, especially high in the maxillary molar area. The Kruskal-Wallis analysis showed that abutment selection has no significant correlation with implant failure(P>.05). CONCLUSION. DENTIS submerged implants with an internal hex connection showed predictable results with a success rate of 97.05%. It is no influence on the success rate in the selection of submerged implant abutment with an internal hex connection.

  • PDF

Implementation of an Electrode Positioning System to Improve the Accuracy and Reliability of the Secondary Battery Stacking Process (2차 전지 적층 공정의 정확성과 신뢰성 향상을 위한 전극 위치결정 시스템 구현)

  • Lee, June-Hwan
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.6
    • /
    • pp.219-225
    • /
    • 2021
  • As for the battery package method, a prismatic package method is preferred for stability reasons, but it is rapidly expanding due to the stability verification of a pouch type package. The pouch type using the lamination process has an advantage of high battery energy density because it can reduce space waste, but has a disadvantage of low productivity. Therefore, in this paper, by extracting edge detection algorithm precision, pattern algorithm precision, and motion controller recall rate by improving backlight lighting fixtures to minimize light diffusion, securing standards for stereo camera position relationship displacement monitoring, and securing standards for lens release monitoring. We propose to implement a system that ensures accuracy and reliability in positioning. As a result of the experiment, the proposed system shows an average error range of 0.032mm for edge detection, 0.02mm for pattern algorithm, and 0.014mm for motion controller, thus ensuring the accuracy and reliability of the positioning mechanism.

Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model

  • Choi, Yoon-Sil;Oh, Jae-Woon;Lee, Young;Lee, Dong-Woon
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.5
    • /
    • pp.411-421
    • /
    • 2022
  • Purpose: In this study, we aimed to evaluate the degree of heat generation when a novel drill design with an irrigation slot was used with metal sleeve-free (MF) and metal sleeve-incorporated (MI) surgical guides in an environment similar to that of the actual oral cavity. Methods: A typodont with a missing mandibular right first molar and 21 bovine rib blocks were used. Three-dimensional-printed MF and MI surgical guides, designed for the placement of internal tapered implant fixtures, were used with slot and non-slot drills. The following groups were compared: group 1, MI surgical guide with slot drill; group 2, MI surgical guide with a non-slot drill; and group 3, MF surgical guide with a slot drill. A constant-temperature water bath at 36℃ was used. The drilling was performed in 6 stages, and the initial, highest, and lowest temperatures of the cortical bone were measured at each stage using a non-contact infrared thermometer. Results: There were no temperature increases above the initial temperature in any drilling procedure. The only significant difference between the non-slot and slot groups was observed with the use of the first drill in the MI group, with a higher temperature in the non-slot group (P=0.012). When the heat generation during the first and the second drilling was compared in the non-slot group, the heat generation during the first drilling was significantly higher (P<0.001), and there was no significant difference in heat generation between the drills in the slot group. Conclusions: Within the limitations of this study, implant-site preparation with the surgical guide showed no critical increase in the temperature of the cortical bone, regardless of whether there was a slot in the drill. In particular, the slotted drill had a cooling effect during the initial drilling.

Energy-dispersive X-ray spectroscopic investigation of a fractured non-submerged dental implant associated with abutment fracture

  • Truc Thi Hoang Nguyen;Mi Young Eo;Kezia Rachellea Mustakim;Mi Hyun Seo;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.1
    • /
    • pp.43-48
    • /
    • 2023
  • The biocompatibility and durability of implant fixtures are major concerns for dentists and patients. Mechanical complications of the implant include abutment screw loosening, screw fracture, loss of implant prostheses, and implant fracture. This case report aims to describe management of a case of fixture damage that occurred after screw fracture in a tissue level, internal connection implant and microscopic evaluation of the fractured fixture. A trephine bur was used to remove the fixture, and the socket was grafted using allogeneic bone material. The failed implant was examined by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS), which revealed a fractured fixture with both normal and irregular bone patterns. The SEM and EDS results give an enlightenment of the failed fixture surface micromorphology with microfracture and contaminated chemical compositions. Noticeably, the significantly high level of gold (Au) on the implant surface and the trace amounts of Au and titanium (Ti) in the bone tissue were recorded, which might have resulted from instability and micro-movement of the implant-abutment connection over an extended period of time. Further study with larger number of patient and different types of implants is needed for further conclusion.

Detachable zirconia prosthesis using Milled bar and ADD-TOC attachment in partial edentulous mandible: A case report (하악 부분 무치악 환자에서 Milled-bar와 ADD-TOC 부착 장치를 이용한 탈착 가능한 지르코니아 보철물 수복 증례)

  • Min-Sung Sohn;Jung-Bo Huh
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.90-99
    • /
    • 2023
  • Implant overdentures are widely used as a treatment method to restore oral function in completely edentulous or partially edentulous patients with severe bone resorption. Using a milled bar, it is mechanically advantageous as the implant fixtures are splinted. Applying additional attachments to the bar has the advantage of dispersing the stress applied to the implant. In this case, a patient who used implant overdentures using 4 implants wanted to fabricate a new prosthesis due to repeated fractures of the denture and weakened retention. Milled bar with ADD-TOC attachment and zirconia prosthesis were fabricated by CAD-CAM method and mechanically and aesthetically satisfactory results were obtained.

The Development of a Dormitory Management System Using the Ubiquitous and Automation Technology (유비쿼터스와 자동화 기술을 이용한 기숙사 관리 시스템 개발)

  • Jang, Jae-Hyuk;Sim, Gab-Sig
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2009
  • Today the use of RFID is extended in medical. circulation market, manufacture, security field, etc. Besides, the book-lending and the attendance management system are on an increasing trend in the use of RFID The developed dormitory management system is composed of a support program, a room management program, a manager program, and a mobile program etc.. In the support program a student(or a manager) can see his(or all member's) entrance and exit history. The room management program decides whether a student can enter the dormitory or not and manages the use of the power after or inquiring a RFID's input tag information into database server. The manager program is able to input and modify a room state and the fixtures information in the room required to operate the room management program, to set up and retrieve a student's entrance and exit information and a room state information. The mobile program enables a manager to check student's identity whether he is in or out, and the manager can know the personal information of being out in detail.

Stress distribution in implant abutment components made of titanium alloy, zirconia, and polyetheretherketone: a comparative study using finite element analysis (티타늄 합금, 지르코니아, 폴리에테르에테르케톤 지대주 재질에 따른 임플란트 구성요소의 응력분포: 유한 요소 분석을 통한 비교 연구)

  • Sung-Min Kim
    • Journal of Technologic Dentistry
    • /
    • v.46 no.2
    • /
    • pp.21-27
    • /
    • 2024
  • Purpose: This study aimed to analyze the stress distribution and deformation in implant abutments made from titanium (Ti-6Al-4V), zirconia, and polyetheretherketone (PEEK), including their screws and fixtures, under various loading conditions using finite element analysis (FEA). Methods: Three-dimensional models of the mandible with implant abutments were created using Siemens NX software (NX10.0.0.24, Siemens). FEA was conducted using Abaqus to simulate occlusal loads and assess stress distribution and deformation. Material properties such as Young's modulus and Poisson's ratio were assigned to each component based on literature and experimental data. Results: The FEA results revealed distinct stress distribution patterns among the materials. Titanium alloy abutments exhibited the highest stress resistance and the most uniform stress distribution, making them highly suitable for long-term stability. Zirconia abutments showed strong mechanical properties with higher stress concentration, indicating potential vulnerability to fracture despite their aesthetic advantages. PEEK abutments demonstrated the least stress resistance and higher deformation compared to other abutment materials, but offered superior shock absorption, though they posed a higher risk of mechanical failure under high load conditions. Conclusion: The study emphasizes the importance of selecting appropriate materials for dental implants. Titanium offers durability and uniform stress distribution, making it highly suitable for long-term stability. Zirconia provides aesthetic benefits but has a higher risk of fracture compared to titanium. PEEK excels in shock absorption but has a higher risk of mechanical failure compared to both titanium and zirconia. These insights can guide improved implant designs and material choices for various clinical needs.

Evaluation of peri-implant bone defects on cone-beam computed tomography and the diagnostic accuracy of detecting these defects on panoramic images

  • Takayuki Oshima;Rieko Asaumi;Shin Ogura;Taisuke Kawai
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.171-180
    • /
    • 2024
  • Purpose: This study was conducted to identify the typical sites and patterns of peri-implant bone defects on cone-beam computed tomography (CBCT) images, as well as to evaluate the detectability of the identified bone defects on panoramic images. Materials and Methods: The study population included 114 patients with a total of 367 implant fixtures. CBCT images were used to assess the presence or absence of bone defects around each implant fixture at the mesial, distal, buccal, and lingual sites. Based on the number of defect sites, the presentations of the peri-implant bone defects were categorized into 3 patterns: 1 site, 2 or 3 sites, and circumferential bone defects. Two observers independently evaluated the presence or absence of bone defects on panoramic images. The bone defect detection rate on these images was evaluated using receiver operating characteristic analysis. Results: Of the 367 implants studied, 167 (45.5%) had at least 1 site with a confirmed bone defect. The most common type of defect was circumferential, affecting 107 of the 167 implants(64.1%). Implants were most frequently placed in the mandibular molar region. The prevalence of bone defects was greatest in the maxillary premolar and mandibular molar regions. The highest kappa value was associated with the mandibular premolar region. Conclusion: The typical bone defect pattern observed was a circumferential defect surrounding the implant. The detection rate was generally higher in the molar region than in the anterior region. However, the capacity to detect partial bone defects using panoramic imaging was determined to be poor.