• Title/Summary/Keyword: fixtures

Search Result 384, Processing Time 0.027 seconds

Analysis of Propagation Environments for Indoor Wireless Communication Systems at THz Frequencies (THz 실내 무선 통신시스템을 위한 전파환경 분석)

  • Lee, Won-Hui;Chung, Tae-Jin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.2
    • /
    • pp.1-6
    • /
    • 2010
  • Short-range wireless communication systems are expanding at rapid rate, finding application in offices and homes. Development of wireless local network is accompanied by steady increase in the demand for ever higher data rates. This in turn entails the necessity to develop communication systems which operate at higher frequencies. It can be expected that short-rage wireless communication networks will soon push towards the THz frequency range. We use a 3D ray-launching for analysis of propagation environments at the indoor fixtures. We extended the approach from the modeling of the reflectivity of optically thick, smooth building materials at THz frequencies to materials with a rough surface. The simulation result of propagation environment is similar to average received power of reference paper. The RMS delay spread was calculated to be 9.11 ns in a room size of $6m(L){\times}5m(W){\times}2.5m(H)$ for the concrete plaster.

Development of Guidelines for Indoor Environment in Apartment Remodeling Projects (아파트 리모델링의 실내환경 계획지침 개발)

  • Choi, Yoon-Jung
    • Journal of the Korean housing association
    • /
    • v.20 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • The final aim of this study was to propose guidelines for the indoor environment of apartment remodeling projects. The first task of this study was to understand the major elements and the actual condition of the remodeling for apartment unit by carrying out in-depth interviews on residents and specialists. The open-access interviews were conducted with interior designers who have a wide experience of apartment remodeling and residents who live in recently remodeled apartment units. The second task was to evaluate the actual condition of the indoor environment and to analyze the main factors that affect the indoor environment in remodeled apartment units. Field measurements were carried out in twenty apartment units occupied after remodeling, recording indoor environment elements (indoor temperature, globe temperature, relative humidity, $CO_2$, CO, PM10, TVOC, HCHO, illumination, and equivalent noise level). Moreover, resident interviews and researcher observations were carried out to determine the contents of the remodeled unit and to investigate the architectural and living factors(like ventilation characteristics, etc.) related to the indoor environment. The results are as follows. The remodeling elements generally included the changing of lighting fixtures and finishing materials in all the spaces, the integration of the balcony into the children's room, the installation of furniture in the kitchen and the entrance, the changing storage furnitures and equipments in the bathroom. The average levels of each unit of relative humidity, $CO_2$, TVOC, HCHO, equivalent noise level, and illumination were proved to be on the whole in inadequate condition. The factors that affect these indoor elements were classified as remodeling factors (remodeling amounts, extent balcony integration, and lighting fixture exchange), ventilation characteristics, and living factors. According to these results, this research proposed the guidelines for the indoor environment in apartment remodeling projects.

MAXILLARY SINUS AUGMENTATION WITH BOVINE BONE MINERAL(Bio-$Oss^{(R)}$) AND THE MAXILLARY TUBEROSITY (상악결절과 다공성 골 미네랄의 복합이식을 통한 상악동 골이식술)

  • Han, Ki-Deok;Chung, Il-Hyuk;Lee, Eun-Kyung;Suh, Je-Duck;Song, Seung-Il
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.4
    • /
    • pp.391-396
    • /
    • 2007
  • The aim of this study was to evaluate implant stability placed in the maxillary sinus which was augmented with bovine bone mineral(Bio-$Oss^{(R)}$) mixed with autogenous bone from the maxillary tuberosity. Maxillary sinus floor augmentation with the mixture of bovine bone mineral and autogenous maxillary tuberosity bone was performed in 30 maxillary sinuses, and 68 implants were placed at the time of sinus graft. After 6 months of implant placement abutments were connected and implant stability quotient(ISQ) was measured by radio frequency analysis(RFA). In addition, bone level changes was evaluated by taking periapical radiograph. During surgical procedures, no complication was observed, and all patients healed uneventfully. At 6 months the implant showed stable ISQ values. The marginal bone level changes around the fixtures was stably maintained through out the follow up period. This study confirmed that maxillary sinus floor augmentation with mixture of bovine bone mineral and maxillary tuberosity bone could be reliable for bone regeneration in subantral space.

Fixation Method of Prestressed Fiber Optic Sensor (광섬유센서의 프리스트레인 부가 고정방식)

  • Kim, Ki-Soo
    • Composites Research
    • /
    • v.25 no.6
    • /
    • pp.211-216
    • /
    • 2012
  • FBG sensor peaks could be split due to polarization by shear strain, when the fiber optic sensors embedded or attached to the structure. For the fiber optic sensor packages, sensor grating has to be protected from shear strains. Also, pretension has to be applied to the sensor because compressive strain must be measured. Without pretension of sensor, the sensor does not show any change of signal until it is stretched. In order to mesure compressive and tensile strains, two fixing point and prestressed sensor need. In the fixing point, just holding the optical fiber cause slip between core and cladding in the fiber. A Fixation method of prestressed FBG sensors fixed with partially stripped fibers was developed. The sensor package has the prestress controllable fixtures at the fixing points. Prestress to the sensor imposed by controlling the two fixed points with bolts and nuts make it easy to measure compressive strain as well as tensile strain. The fiber optic sensor packages applied to the actual structure and the structural monitoring system using the package can be applied to safety through surveillance.

Maxillary sinus augmentation with biphasic calcium phosphate(Osteon$^{(R)}$); A clinical and radiographic study (Original Article 1 - 합성골 이식재인 Osteon$^{(R)}$을 이용한 상악동 거상술-임상적, 방사선 계측학적 연구)

  • Cha, Jae-Kook;Jung, Ui-Won;Kim, Min-Soo;Um, Yoo-Jung;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho;Chung, Sung-Min
    • The Journal of the Korean dental association
    • /
    • v.48 no.1
    • /
    • pp.45-55
    • /
    • 2010
  • Purpose: The aim of this study was to evaluate 1 year cumulative survival rate of implants placed on augmented sinus using Osteon$^{(R)}$, bone graft material and to assess height of the grafted material radiographically. Material and Methods: 10 maxillary sinuses were augmented in 10 patients and 25 implant fixtures were installed simultaneously or after 6 months healing period. The height of the sinus graft material was measured using panoramic images immediately after augmentation and up to 19 months subsequently. Changes in the height of the sinus graft material were calculated with respect to implant length and original sinus wall height. Results: The cumulative survival rate was 100% in all 25 implants. Additionally, normal healing process without any complication was observed in all patients. The mean crown/Implant ratio was 1.25. The mean marginal bone loss was 0.95mm and the mean resorption rate of Osteon$^{(R)}$ was 0.05mm/month. The fastest resorption site of Osteon$^{(R)}$ is the first molar area. The grafted material was well maintained in sinus and decreased slightly over 1 year. Conclusion: In conclusion, It can be suggested that Osteon$^{(R)}$ may have predictable result when it was used as a grafting material for sinus floor augmentation.

Comparison of changes in retentive force of three stud attachments for implant overdentures

  • Kim, Su-Min;Choi, Jae-Won;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.303-311
    • /
    • 2015
  • PURPOSE. The aim of this study was to compare the changes in retentive force of stud attachments for implant overdentures by in vitro 2-year-wear simulation. MATERIALS AND METHODS. Three commercially available attachment systems were investigated: Kerator blue, O-ring red, and EZ lock. Two implant fixtures were embedded in parallel in each custom base mounting. Five pairs of each attachment system were tested. A universal testing machine was used to measure the retentive force during 2500 insertion and removal cycles. Surface changes on the components were evaluated by scanning electron microscopy (SEM). A Kruskal-Wallis test, followed by Pairwise comparison, was used to compare the retentive force between the groups, and to determine groups that were significantly different (${\alpha}$<.05). RESULTS. A comparison of the initial retentive force revealed the highest value for Kerator, followed by the O-ring and EZ lock attachments. However, no significant difference was detected between Kerator and O-ring (P>.05). After 2500 insertion and removal cycles, the highest retention loss was recorded for O-ring, and no significant difference between Kerator and EZ lock (P>.05). Also, Kerator showed the highest retentive force, followed by EZ lock and O-ring, after 2500 cycles (P<.05). Based on SEM analysis, the polymeric components in O-ring and Kerator were observed to exhibit surface wear and deformation. CONCLUSION. After 2500 insertion and removal cycles, all attachments exhibited significant loss in retention. Mechanism of retention loss can only be partially explained by surface changes.

Photoelastic Stress Analysis of Single Implant Restoration According to Implant Fixture Size and Abutment Diameter (단일치 임플란트에서 고정체와 지대주 직경의 차이에 따른 광탄성 응력 분석)

  • Lee, Jin-Han;Cho, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.253-267
    • /
    • 2008
  • The purpose of this study was to evaluate the pattern and the magnitude of stress distribution in the supporting tissues surrounding implant fixture with different diameter of implant fixtures(3i implant, Ø4.0, Ø5.0, Ø6.0mm and UCLA abutments(Ø4.1, Ø5.0, Ø6.0mm using photoelastic stress analysis. Photoelastic model was made with PL-2 resin(Measurements Group, Raleigh, USA) and three implants of each diameter were placed in the mandibular posterior edentulous area distal to the canine. Individual crowns were fabricated using UCLA abutments. Photoelastic stress analysis was carried out to measure the fringe order around the implant supporting structure under simulated loading conditions(15 lb, 30 lb). The results were as follows; 1. The more the diameter of implant fixture was increased, the less the stress concentration on cervical area of fixture was observed under loading. 2. Increasing mesiodistal diameter of implant superstructure had no much influence on stress distribution around implant fixture. 3. The use of smaller abutment had no influence on stress distribution around implant fixture. The use of smaller abutment diameter than that of implant fixture had no favorable effect on implant supporting tissue at biomechanical consideration.

A Heuristic for parallel Machine Scheduling Depending on Job Characteristics (작업의 특성에 종속되는 병렬기계의 일정계획을 위한 발견적 기법)

  • 이동현;이경근;김재균;박창권;장길상
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.17 no.1
    • /
    • pp.41-41
    • /
    • 1992
  • In the real world situations that some jobs need be processed only on certain limited machines frequently occur due to the capacity restrictions of machines such as tools fixtures or material handling equipment. In this paper we consider n-job non-preemptive and m parallel machines scheduling problem having two machines group. The objective function is to minimize the sum of earliness and tardiness with different release times and due dates. The problem is formulated as a mixed integer programming problem. The problem is proved to be Np-complete. Thus a heuristic is developed to solve this problem. To illustrate its suitability and efficiency a proposed heuristic is compared with a genetic algorithm and tabu search for a large number of randomly generated test problems in ship engine assembly shop. Through the experimental results it is showed that the proposed algorithm yields good solutions efficiently.

HISTOMORPHOMETRIC EVALUATION OF OSTEOGENESIS WITH BRUSHITE IMPLANT SURFACES IN DOGS (성견에서 거친 표면을 가지는 임플란트에서 골형성에 관한 조직형태계측학적인 평가)

  • Moon, Chul-Woong;Kim, Su-Gwan;Kim, Hak-Kyun;Moon, Seong-Yong;Lim, Sung-Chul;Oh, Ji-Su;Baik, Sung-Mun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.2
    • /
    • pp.150-157
    • /
    • 2008
  • This study evaluated the influence of smooth and brushite-coated implant surfaces in dogs. The first through fourth mandibular premolars were extracted from eight young adult dogs. Twelve weeks after extraction. implantation was performed at the extraction sites. In total, 40 implant fixtures were implanted in the dog mandibles. Twenty machined implants served as controls and twenty brushite-coated surfaces served as tests. Dogs were sacrificed 2 and 4 weeks after implantation. The hemi-mandibles were obtained and processed histologically to obtain non-decalcified sections. Longitudinal sections of each implant were made and analyzed using light microscopy. The overall implant success rate was 83.3%. Histomorphometrically. the experimental group had a better percentage of bone-implant contact than the control group (p<0.05) and there was a significant difference between the 2- and 4-week groups after implantation (p<0.05) Our results suggest that the implant surface morphology influences the increase in peri-implant osteogenesis in the early period of peri-implant healing.

Clinical Study on Outfracture Osteotomy Sinus Graft (Outfracture Osteotomy Sinus Graft에 대한 임상적 연구)

  • Seo, Eun Woo;Lee, Ho Kyung;Song, Seung Il;Lee, Jeong Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.2
    • /
    • pp.94-99
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the feasibility of the outfracture osteotomy sinus graft technique with the evaluation of 8.5 year survival rate of the implants placed in the atrophic edentulous posterior maxillary area. Methods: One hundred and seventy-six cases of 145 patients who visited our center from August 2004 to February 2013 and were diagnosed as atrophic edentulous maxillary alveolar ridge, were selected and underwent sinus graft with outfracture osteotomy sinus graft technique. Feasibility of the outfracture osteotomy sinus graft technique was investigated with clinical and radiographic evaluation to assess the survival rate of the total dental implants in augmentation sinus surgery. Total fixture number available in follow-up period was 320, in which the lost 15 patients were excluded out of 160 patients. Results: Eight point five year cumulative survival rate was 95.6% with 14 failures of total 320 fixtures. The average follow-up period was 28 months 16 days with the minimum and maximum follow-up periods of 4 months 5 days and 94 months 10 days, respectively. Conclusion: Traditional infracture technique is a popular method for an augmentation sinus surgery. The authors modified this classical method by outfracturing and readapting the bony window after sinus graft, with excellent treatment results evidenced by high survival rate, which proves the feasibility of the newly-designed outfracture osteotomy sinus graft technique.