• 제목/요약/키워드: fixed-roof tank

검색결과 4건 처리시간 0.02초

Wind loads on fixed-roof cylindrical tanks with very low aspect ratio

  • Lin, Yin;Zhao, Yang
    • Wind and Structures
    • /
    • 제18권6호
    • /
    • pp.651-668
    • /
    • 2014
  • Wind tunnel tests are conducted to investigate the wind loads on vertical fixed-roof cylindrical tanks with a very low aspect ratio of 0.275, which is a typical ratio for practical tanks with a volume of $100,000m^3$. Both the flat-roof tank and the dome-roof tank are investigated in present study. The first four moments of the measured wind pressure, including the mean and normalized deviation pressure, kurtosis and skewness of the pressure signal, are obtained to study the feature of the wind loads. It is shown that the wind loads are closely related to the behavior of flow around the structure. For either tank, the mean wind pressures on the cylinder are positive on the windward area and negative on the sides and the wake area, and the mean wind pressures on the whole roof are negative. The roof configurations have no considerable influence on the mean pressure distributions of cylindrical wall in general. Highly non-Gaussian feature is found in either tank. Conditional sampling technique, envelope method, and the proper orthogonal decomposition (POD) analysis are employed to investigate the characteristics of wind loads on the cylinder in more detail. It is shown that the patterns of wind pressure obtained from conditional sampling are similar to the mean pressure patterns.An instantaneous pressure coefficient can present a wide range from the maximum value to the minimum value. The quasi-steady assumption is not valid for structures considered in this paper according to the POD analysis.

Shaking Table Test of Steel Cylindrical Liquid Storage Tank Considering the Roof Characteristics

  • Bae, Doobyong;Park, Jang Ho
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1167-1176
    • /
    • 2018
  • Steel cylindrical tanks are widely used for the storage of hazardous substances of which leakage must be prevented under any circumstances. However, the dynamic response of the steel cylindrical liquid storage tank depends sensitively on the fluid-structure interaction and the vibration of the tank structure and necessitates clarification for the safety of the tank structure. This paper presents the results of shaking table tests performed to examine the dynamic behavior of a scaled cylindrical steel tank model considering the presence or not of fixed roof and added mass at the top of the tank for various fluid levels. The test results confirm the occurrence of both beam-type and oval-type vibration modes and show that the larger content of liquid inside the container amplified the acceleration along the height of the cylindrical tank. The oval-type vibration modes are seen to be more dominant in case of large water-to-structure mass ratio.

내부 부상형저장탱크(IFRT) 화재·폭발 예방대책에 관한 연구 (Study of Fire and Explosion Prevention of an Internal Floating Roof Tank)

  • 구채칠;최재욱
    • 한국화재소방학회논문지
    • /
    • 제33권1호
    • /
    • pp.45-49
    • /
    • 2019
  • 본 연구는 옥외저장탱크에서 발생한 화재의 근본적인 원인분석을 통해 저장탱크의 안전을 유지할 목적으로 수행되었다. 옥외저장탱크는 위험물을 장기간 저장하기 위한 고정장치로 탱크본체 및 부속장치로 구성되며, 부속장치는 벤트 시스템, 브레더 밸브, 화염방지기 등으로 구성된다. 화염방지기는 옥외저장탱크의 화재 폭발을 방지하기 위해 필요한 안전장치이다. 하지만 최근 발생한 옥외저장탱크 화재를 계기로 기존에 설치되어 운용중인 옥외저장탱크에 안전성 확보 차원에서 화염방지기를 의무적으로 설치해야 하는지 국내 외 기준을 비교 분석하여 화염방지기 설치가 필요함을 제시하였고, 화염방지기의 성능을 검증할 수 있는 국내기준이 부족하므로 외국 기준을 참고하여 보완할 필요성이 있다.

콘크리트 타설에 따른 지하식 LNG 저장탱크 컴프레션링 거동 분석 (The Analysis of Inground LNG Storage Tank Compression Ring Behavior during Concrete Pouring)

  • 김영균;김지훈;윤인수;오병택;양영명
    • 한국가스학회지
    • /
    • 제9권2호
    • /
    • pp.16-21
    • /
    • 2005
  • LNG저장탱크에서의 컴프레션링의 역할은 콘크리트 벽체에 고정되어 Steel 루프 플레이트를 연결지지 하는 것이다. 구체적으로는 한쪽 끝부분은 콘크리트 벽체에 묻혀 고정되며 다른 쪽 끝부분은 루프 플레이트와 용접 연결되어 중첩된다. 이러한 조건에서 예측되는 하중 조건인 자중, 내부압력 및 콘크리트 무게에 대한 충분한 안전성을 확보하도록 설계되어야 한다. 본 논문에서는 유한요소법과 실제 시공 시 계측을 통해 획득한 데이터를 이용하여 콘크리트 타설 시공에 따른 컴프레션링의 거동을 파악하였다. 또한 설계변수 변화에 따른 컴프레션링의 거동을 분석한 결과를 기본으로 하여 보다 합리적인 설계법을 제시 하고자 하였다.

  • PDF