• 제목/요약/키워드: fixed-length analysis

검색결과 309건 처리시간 0.025초

Nonlinear vibration analysis of MSGT boron-nitride micro ribbon based mass sensor using DQEM

  • Mohammadimehr, M.;Monajemi, Ahmad A.
    • Smart Structures and Systems
    • /
    • 제18권5호
    • /
    • pp.1029-1062
    • /
    • 2016
  • In this research, the nonlinear free vibration analysis of boron-nitride micro ribbon (BNMR) on the Pasternak elastic foundation under electrical, mechanical and thermal loadings using modified strain gradient theory (MSGT) is studied. Employing the von $K{\acute{a}}rm{\acute{a}}n$ nonlinear geometry theory, the nonlinear equations of motion for the graphene micro ribbon (GMR) using Euler-Bernoulli beam model with considering attached mass and size effects based on Hamilton's principle is obtained. These equations are converted into the nonlinear ordinary differential equations by elimination of the time variable using Kantorovich time-averaging method. To determine nonlinear frequency of GMR under various boundary conditions, and considering mass effect, differential quadrature element method (DQEM) is used. Based on modified strain MSGT, the results of the current model are compared with the obtained results by classical and modified couple stress theories (CT and MCST). Furthermore, the effect of various parameters such as material length scale parameter, attached mass, temperature change, piezoelectric coefficient, two parameters of elastic foundations on the natural frequencies of BNMR is investigated. The results show that for all boundary conditions, by increasing the mass intensity in a fixed position, the linear and nonlinear natural frequency of the GMR reduces. In addition, with increasing of material length scale parameter, the frequency ratio decreases. This results can be used to design and control nano/micro devices and nano electronics to avoid resonance phenomenon.

Sensitivity Analysis for Joint Pricing and Lot-sizing Model with Price Dependent Demand under Day terms Supplier Credit in a Two-stage Supply Chain

  • Shinn, Seong-Whan
    • International Journal of Advanced Culture Technology
    • /
    • 제8권2호
    • /
    • pp.270-276
    • /
    • 2020
  • In this paper, we analyze the buyer's joint pricing and lot-sizing model in a two-stage supply chain consisting of the supplier, the buyer and the customer. It is assumed that the supplier will permit a certain fixed period for settling the amount the buyer owes to him for the items supplied in order to stimulate the demand for the product. Generally, credit transactions would have a positive effect to the buyer. The availability of credit transactions from the supplier effectively reduces the cost of holding stocks for the buyer and therefore, the buyer has a lot of price options to choose his sales price for a customer in anticipation of increased the customer's demand and, as a result, it will appear to increase the buyer's inventory levels. On the other hand, in the case of decaying products in which their utility decay over time, the decaying rate with time may be expected to reduce inventory levels. In this regard, we need to analyze how much the length of credit period and the decaying rate affect the buyer's pricing and lot-sizing policy. For the analysis, we consider the situation where the customer's demand is represented as a linearly decreasing function of the buyer's sales price. From this perspective, we formulate the buyer's annual net profit and analyze the effect of the length of credit period and decaying rate of the product on the buyer's inventory policy numerically.

Comparative evaluation of peri-implant stress distribution in implant protected occlusion and cuspally loaded occlusion on a 3 unit implant supported fixed partial denture: A 3D finite element analysis study

  • Acharya, Paramba Hitendrabhai;Patel, Vilas Valjibhai;Duseja, Sareen Subhash;Chauhan, Vishal Rajendrabhai
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.79-88
    • /
    • 2021
  • Purpose. To assess peri-implant stress distribution using finite element analysis in implant supported fixed partial denture with occlusal schemes of cuspally loaded occlusion and implant protected occlusion. Materials and methods. A 3-D finite element model of mandible with D2 bone with partially edentulism with unilateral distal extension was made. Two Ti alloy identical implants with 4.2 mm diameter and 10 mm length were placed in the mandibular second premolar and the mandibular second molar region and prosthesis was given with the mandibular first molar pontic. Vertical load of 100 N and and oblique load of 70 N was applied on occlusal surface of prosthesis. Group 1 was cuspally loaded occlusion with total 8 contact points and Group 2 was implant protected occlusion with 3 contact points. Results. In Group 1 for vertical load, maximum stress was generated over implant having 14.3552 Mpa. While for oblique load, overall stress generated was 28.0732 Mpa. In Group 2 for vertical load, maximum stress was generated over crown and overall stress was 16.7682 Mpa. But for oblique load, crown stress and overall stress was maximum 22.7561 Mpa. When Group 1 is compared to Group 2, harmful oblique load caused maximum overall stress 28.0732 Mpa in Group 1. Conclusion. In Group 1, vertical load generated high implant stress, and oblique load generated high overall stresses, cortical stresses and crown stresses compared to vertical load. In Group 2, oblique load generated more overall stresses, cortical stresses, and crown stresses compared to vertical load. Implant protected occlusion generated lesser harmful oblique implant, crown, bone and overall stresses compared to cuspally loaded occlusion.

승모판 역류 In-Vitro 모델을 활용한 초음파 및 4D flow MRI 기반 혈류 정량화 비교연구 (In-Vitro Model Design of Mitral Valve Regurgitation and Comparative Study of Quantification between PISA and 4D flow MRI)

  • 이주연;권민성;허형규
    • 한국가시화정보학회지
    • /
    • 제22권1호
    • /
    • pp.40-48
    • /
    • 2024
  • This study presents an in-vitro model designed to simulate mitral valve regurgitation, aiming to compare the quantification results between Proximal Isovelocity Surface Area(PISA) and 4D Flow MRI on both fixed and valve annulus tracking(VAT) views. The in-vitro model replicates the dynamic conditions of the mitral valve in a pulsatile environment, utilizing a piston pump set at 60 bpm. Through systematic experiments and analysis, the study evaluates the accuracy and effectiveness of PISA and 4D Flow MRI in assessing regurgitation severity, considering both fixed and valve annulus tracking. The displacement length measured in echo closely resembled that of optical measurements, making it advantageous for structural analysis. VAT-4D flow MRI exhibited the smallest deviation from actual flow rate values, establishing it as most accurate method for quantitative regurgitation assessment.

불규칙가진의 반발계수 진동-충격 시스템의 수치해석 (Numerical Analysis of Randomly Driven Vibro-Impact System With a Coefficient of Restitution Contact Mechanism)

  • 이창희
    • 소음진동
    • /
    • 제8권3호
    • /
    • pp.513-523
    • /
    • 1998
  • Impact response of a vibro-impact system and its contact mechanism was studied. The vibro-impact system is composed of a small secondary system is constrained to move along a slot of fixed length in a large primary system. The contact mechanism is characterized by its coefficient of restitution. Numerical simulation analysis has been used to determine the time-history and the impact statistics of the primary and secondary systems. Input excitation of the primary system was random, and the responses obtained were the velocities of the primary and secondary system, the closing velocity in time axis and the duration time between impacts. The validity of the numerical simulation method was checked by comparing the results with those obtained by other researchers analytically. It is shown that the results obtained by the nemerical simulation analysis showed a good agreement with those for the analytical method.

  • PDF

Effect of FRP parameters in strengthening the tubular joint for offshore structures

  • Prashob, P.S.;Shashikala, A.P.;Somasundaran, T.P.
    • Ocean Systems Engineering
    • /
    • 제8권4호
    • /
    • pp.409-426
    • /
    • 2018
  • This paper presents the strengthening of tubular joint by wrapping Carbon fiber reinforced polymer (CFRP) and glass fiber reinforced polymer (GFRP). In this study, total number of layers, stacking sequence and length of wrapping are the different parameters involved when fiber reinforced polymers (FRP) composites are used for strengthening. For this, parameters where varied and results were compared with the reference joint. The best stacking sequence was identified which has the highest value in ultimate load with lesser deflections. For determining the best stacking sequence, numerical investigation was performed on CFRP composites; length of wrapping and number of layers were fixed. Later, the studies were focused on CFRP and GFRP strengthened joint by varying the total number of layers and length of wrapping. An attempt was done to propose a parametric equation from multiple regression analysis, which can be used for CFRP strengthened joints. Hashin failure criteria was used to check the failure of composites. Results revealed that FRP was having a greater influence in the load bearing capacity of joints, and in reducing the deflections and stresses of joint under axial compressive loads. It was also seen that, CFRP was far better than GFRP in reducing the stresses and deflection.

화재진압 시 발생하는 주수 기둥의 저항분석 방법 연구 (A Study on the Method of Resistance Analysis of Water Stream During Fire Supperession)

  • 정병선;김응식;박종열
    • 한국안전학회지
    • /
    • 제33권6호
    • /
    • pp.22-27
    • /
    • 2018
  • Fire fighters are exposed to the risk of many accidents during fire suppression, especially near the high voltage circuit. In order to prevent and analyze the electric shock accidents, measurement of water resistance is crucial. However, this has been one of the overlooked research areas and it has been very difficult to measure the mixed up resistance components separately. In this paper, we measured a total resistance of apparatus and regarded it as a serial resistance of contact resistance and length dependant resistance. Measuring the resistance by varying the length of water stream, the variable resistance and fixed contact resistance appear, which are used to calculate the both components of resistances. In addition, the resistance of fire hose can be calculated from the parallel circuit which is formed by grounding the fire hose with the resistance of water stream. Results show that we can successfully measure the resistance per unit length of water stream and fire hose, thereby proving that this method is a facile way to measure water and fire hose resistance. However, many experiments are still required to obtain the precise contact resistance of ground under various condition and the resistance between the human body and fire hose.

Could Clinical Pathways Improve the Quality of Care in Patients with Gastrointestinal Cancer? A Meta-analysis

  • Song, Xu-Ping;Tian, Jin-Hui;Cui, Qi;Zhang, Ting-Ting;Yang, Ke-Hu;Ding, Guo-Wu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권19호
    • /
    • pp.8361-8366
    • /
    • 2014
  • This meta-analysis was performed to assess the implementation effects of clinical pathways in patients with gastrointestinal cancer. A comprehensive search was conducted in the Cochrane Library, PubMed, EMBASE, Web of Science and Chinese Biomedical Literature Database (from inception to May 2014). Selection of studies, assessing risk of bias and extracting data were performed by two reviewers independently. Outcomes were analyzed by fixed-effects and random-effects model meta-analysis and reported as mean difference (MD), standardized mean difference (SMD) and odds ratio (OR) with 95% confidence intervals (CI). The Jadad methodological approach was used to assess the quality of included studies and the meta-analysis was conducted with RevMan 5.1 software. Nine citations (eight trials) involving 642 patients were included. The aggregate results showed that a shorter average length of stay [MD = -4.0; 95% CI (-5.1, -2.8); P < 0.00001] was observed with the clinical pathways as compared with the usual care. A reduction in inpatient expenditure [SMD = -1.5; 95% CI (-2.3, -0.7); P = 0.0001] was also associated with clinical pathways, along with higher patient satisfaction [OR = 4.9; 95% CI (2.2, 10.6); P < 0.0001]. Clinical pathways could improve the quality of care in patients with gastrointestinal cancer, as evidenced by a significant reduction in average length of stay, a decrease in inpatient expenditure and an improvement in patient satisfaction. Therefore, indicators and mechanisms within clinical pathways should be a focus in the future.

연결고정, 인접면 접촉강도 및 치관길이에 따른 엔도포어 임플란트를 이용한 고정성 국소의치의 광탄성 응력 분석 (A PHOTOELASTIC STRESS ANALYSIS OF FIXED PARTIAL DENTURES WITH ENDOPOREIMPLANTS ACCORDING TO SPLINTING, CONTACT TIGHTNESS, AND CROWN LENGTH)

  • 정회열;최민호;김유리;조혜원
    • 대한치과보철학회지
    • /
    • 제42권4호
    • /
    • pp.425-442
    • /
    • 2004
  • Statement of problem: A difficulty in achieving a passive-fitting prosthesis can be overcome by individual crown restoation of multiple implants. But individualized crown has another difficulty in control of contact tightness and stress distribution. Purpose: This in vitro study is to evaluate the stress distribution and the magnitude in the supporting tissues around Endopore implants with different crown lengths, interproximal contact tightness, and the splinting effects. Material & methods: Three Endopore implants($4.1{\times}9mm$) were placed in the mandibular posterior edentulous area distal to the canine and photoelastic model was made with PL-2 resin(Measurements Group, Raleigh, USA). Restorations were fabricated in two crown lengths: 9, 13 mm. For non-splinted restorations, individual crowns were fabricated on three custom-milled titanium abutments. After the units were cemented, 4 levels of interproximal contact tightness were evaluated: open, ideal($8{\mu}m$ shim stock drags without tearing), medium($40{\mu}m$), and heavy($80{\mu}m$). For splinted restorations, 3-unit fixed partial dentures were fabricated. This study was examined under simulated non-loaded and loaded conditions(6.8 kg). Photoelastic stress analysis was carried out to measure the fringe order around the implant supporting structure. Results: 1. When restorations were not splinted, the more interproximal contact tightness was increased among the three implants, the more stress was shown in the cervical region of each implant. When crown length was increased, stresses tended to increase in the apex of implants but there were little differences in stress fringes. 2. When nonsplinted restorations were loaded on the first or third implant, stresses were increased in the apex and cervical region of loaded implant. Regardless of interproximal contact tightness level, stresses were not distributed among the three implants. But with tighter interproximal contact, stresses were increased in the cervical region of loaded first or third implant. 3. When the nonsplinted restorations were not loaded, there were little stresses on the supporting structure of implants, but low level stresses were shown in the splinted restorations even after sectioning and soldering. 4. With splinted restorations, there were little differences in stresses between different crown lengths. When splinted restorations were loaded, stresses were increased slightly on the loaded implant, but relatively even stress distribution occurred among the three implants. Conclusions: Splinting the crowns of adjacent implants is recommended for Endopore implants under the overloading situation.

장파장 적외선 렌즈의 비구면 및 회절면 효과 분석 (Analysis of aspheric and diffractive surface effect for long wavelength infrared lens)

  • 김현수;이동한;김현규;이국환
    • 한국광학회지
    • /
    • 제14권4호
    • /
    • pp.369-376
    • /
    • 2003
  • 장파장 적외선 영역에서, 비구면 및 회절면을 동시 또는 단독으로 사용했을 때 렌즈의 성능에 미치는 영향을 분석하였다. 유효초점거리(efl: effective focal length)를 100 mm로 고정하고 반시야 각(half field angle)을 5$^{\circ}$에서 30$^{\circ}$까지 5$^{\circ}$간격으로 증가시켰을 때 수치구경 값의 변화를 고찰하였다. 렌즈의 광학성능은 장점함수(merit function)를 기준으로 사용하였다. 이 분석을 근거로 픽셀 크기 45 $\mu$m, 픽셀 수 320${\times}$240검출기를 기준으로 비냉각 열상장비용으로 사용 가능한 F/l.0인 광학계를 설계하였다.