• Title/Summary/Keyword: fitting test

Search Result 596, Processing Time 0.028 seconds

Comparison of Clinical Usefulness of Program-Assisted and Real Ear Measurement-Assisted Hearing Aids Fitting (프로그램과 실이 측정을 이용한 보청기 적합의 임상적 유용성의 비교)

  • Chang, Young-Soo;Jung, Hye Im;Cho, Yang-Sun
    • Korean Journal of Otorhinolaryngology-Head and Neck Surgery
    • /
    • v.61 no.12
    • /
    • pp.663-668
    • /
    • 2018
  • Background and Objectives The main objectives of this study were to determine the clinical usefulness of the program-assisted and real ear measurement (REM)-assisted fitting of hearing aids. Subjects and Method Fifteen participants with moderate to moderately severe hearing loss were enrolled in this study. Objective and subjective fitting results were assessed to compare the benefits between the program-assisted fitting (using a software fitting program) and the REM-assisted fitting. Real ear insertion gain (REIG), sound-field audiometry using warble tone, and Korean Hearing in Noise Test (K-HINT) were performed as objective tests. Sound quality rating was performed as a subjective test. Results In the program fitting, 48.89% of fitting points failed to come within ${\pm}10dB$ of the REIG target. In the REM fitting, however, the percentage of failure significantly decreased to 23.33% (p=0.013). In K-HINT test, the reception threshold for speech in quiet situation significantly decreased from 50.1 dB HL with the program fitting to 44.7 dB HL after the REM fitting (p<0.001). In front noise condition, signal-to-noise ratio improved from 4.53 dB to 3.50 dB with the REM fitting without statistical significance (p=0.099). In the sound quality rating, the REM fitting ($4.27{\pm}0.56$) showed a significantly better sound quality ratings than the program fitting ($3.69{\pm}0.74$) (p=0.017). Conclusion The REM fitting showed better results in both subjective and objective measurements than the program fitting.

Life Analysis of Flexible Tubes Fitting for Pneumatic system (공기압용 관연결 피팅의 수명 분석)

  • Kang, Bo-Sik;Song, Joo-Sub;Yoo, Yung-Chul;Kim, Hyoung-Eui
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1842-1847
    • /
    • 2007
  • In this study, we are to analyze the life and the main failure mode of flexible tubes fitting for pneumatic that are usually applied in the factory automation line. Flexible tubes fitting for pneumatic have complicated failure cause because they are organized as a complex of various elements. Therefore, in this paper, we analyzed the main failure mode of flexible tubes fitting for pneumatic, and then performed life test and performance test according to the international standards. On the basis of these processes, we estimate shape parameter that is the main factor for the calculation of test time for the reliability of flexible tubes fitting for pneumatic and their data analysis of life distribution.

  • PDF

Use of the Modified Linear Curve Fitting Method in Analyzing Slug Tests to Evaluate Hydraulic Conductivity of Vertical Cutoff Walls (순간 변위시험 (Slug Test)을 이용한 연직차수벽의 투수계수 산정시 수정된 Linear Curve Fitting 방법의 적용)

  • Choi, Hang-Seok;Daniel David E.
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.338-347
    • /
    • 2006
  • 연직차수벽은 오염지역이나 폐기물 매립장에서 오염된 지하수 (때로는 오염된 수증기) 흐름을 차단하거나 또는 오염지역의 정화처리시 효율을 높이기 위하여 외부로부터 지하수 흐름을 막기 위해 설치된다. 이 논문에서는 연직차수벽의 가장 중요한 설계요소인 차수벽체의 현장 투수성을 평가하는 방법들중 가장 보편적으로 사용되는 단공식 순간 변위시험 (slug test)을 소개한다. 연직차수벽에서 실행된 단공식 순간 변위시험 결과를 해석하기 위해서, 연직차수벽의 압축성과 기하학적인 특성을 고려한 수정된 linear curve fitting 방법을 제안하고 그 적용성을 case study를 통해 평가한다. 기존의 대수층 투수계수 산정에 이용된 curve fitting 방법들에 비하여 수정된 linear curve fitting 방법은 보다 정확한 연직차수벽체의 투수성을 평가하도록 한다.

  • PDF

Development of Smart Phone Application with User Fitting for Hearing Impaired in Various Environment (환경별 사용자 피팅이 가능한 스마트폰 보청기 어플리케이션 개발)

  • Lee, K.;Kang, S.-I.;Park, G.S.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.2
    • /
    • pp.121-128
    • /
    • 2015
  • In this paper, we introduce our smart phone application for hearing impaired people. Unlike previous hearing aids application, our application has both functions of self hearing tests and sound amplification. We provide user with two types of self hearing test, those are standard hearing test and detail hearing test. Each test has different advantages like short test time and accurate test result, however both tests provide reliable result. Our hearing test allows that user can measure their hearing loss level according to the frequency. Sound amplification function provide proper fitting formula by using NAL-NL1, and it guarantees high speech intelligibility. Our application can also memorize user's fitting data at specific test condition. Therefore those who using our hearing aids application can easily reset their hearing aids / earphone properties periodically. Our application is advanced at the aspect of self fitting function that no other previous application did. So we are expecting these comfortable processes about fitting lead the number of hearing aids user to be increased.

  • PDF

Plastic Displacement Estimates in Creep Crack Growth Testing (크리프 균열 성장 실험을 위한 소성 변위 결정법)

  • Huh Nam-Su;Yoon Kee-Bong;Kim Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.10 s.253
    • /
    • pp.1219-1226
    • /
    • 2006
  • The ASTM test standard recommends the use of the compact tension specimen for creep crack growth rates measurement. In the creep crack growth rate test, the displacement rate due to creep is obtained by subtracting the contribution of elastic and plastic components from the total load line displacement rate based on displacement partitioning method fur determining $C^*-integral$, which involves Ramberg-Osgood (R-O) fitting procedures. This paper investigates the effect of the R-O fitting procedures on plastic displacement rate estimates in creep crack growth testing, via detailed two-dimensional and three-dimensional finite element analyses of the standard compact tension specimen. Four different R-O fitting procedures are considered; (i) fitting the entire true stress-strain data up to the ultimate tensile strength, (ii) fitting the true stress-strain data from 0.1% strain to 0.8 of the true ultimate strain, (iii) fitting the true stress-strain data only up to 5% strain, and (iv) fitting the engineering stress-strain data. It is found that the last two procedures provide reasonably accurate plastic displacement rates and thus should be recommended in creep crack growth testing. Moreover, several advantages of fitting the engineering stress-strain data over fitting the true stress-strain data only up to 5% strain are discussed.

A Study of Korean Non-linear Fitting Formula based on NAL-NL1 for Digital Hearing Aids (디지털 보청기에서의 NAL-NL1 기반 한국형 비선형 fitting formula 연구)

  • Kim, H.M.;Lee, S.M.
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.169-178
    • /
    • 2009
  • In this study, we suggest Korean nonlinear fitting formula (KNFF) to maximize speech intelligibility for digital hearing aids based on NAL-NL1 (NAL-nonlinear, version 1). KNFF was derived from the same procedure which is used for deriving NAL-NL1. KNFF consider the long-term average speech spectrum of Korean instead of English because the frequency characteristic of Korean is different from that of English. New insertion gains of KNFF were derived using the SII (speech intelligibility index) program provided by ANSI. In addition, the insertion gains were modified to maximize the intelligibility of high frequency words. To verify effect of the new fitting gain, we performed speech discrimination test (SDT) and preference test using the hearing loss simulator from NOISH. In the SDT, a word set as test material consists of 50 1-syllable word generally used in hearing clinic. As a result of the test, in case of moderate hearing loss with severe loss on high frequency, the SDT scores of KNFF was more improved about 3.2% than NAL-NLl and about 6% in case of the sever hearing loss. Finally we have obtained the result that it was the effective way to increase gain of mid-high frequency bands and to decrease gain of low frequency bands in order to maximize speech intelligibility of Korean.

End-fitting Design and Performance Evaluation of Polymer Insulator (폴리머 애자의 End-fitting 설계 및 성능 평가기술)

  • Cho, H.G.;Lee, U.Y.;Han, S.W.;Han, D.H.;Ji, W.Y.;Yeo, H.G.;Kang, D.W.;Chun, J.U.;Lee, H.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.25-29
    • /
    • 2004
  • Corona on polymer materials causes deterioration by the combined action of the discharge striking the surface and the action of certain chemical compounds that are formed by the discharges. In the design and manufacture of polymer insulators must be sufficiently large to avoid corona discharges, otherwise a shielding or corona ring (grading ring) needs to be installed on the insulator. To conduct this purpose, many researchers have investigated end-fitting of polymer insulator by voltage distribution simulation and electrical test. Grading rings are used to improve the performance of the insulator in multiple ways. They can reduce corona and associated audible noise and radio influence and television interference. The factors determining the uses of a grading ring are line voltage, geometry and dimensions of end fittings, geometry and dimensions of line hardware, and environmental conditions. In this paper, electrical property of polymer insulator with end-fitting design have been investigated by electrical field analysis, various end-fitting design, tracking wheel test, corona inception voltage and extinction voltage. Electrical field analysis is conducted by FEM program and various end-fitting is designed through this result. Designed end-fittings are manufactured and their performance is conducted by electrical performance test.

  • PDF

The Correlation Between Corneal Eccentricity and Radius Curvature by Fitting Status of Soft Contact Lens Wearer (소프트 콘택트렌즈 착용자의 피팅 상태에 따른 각막 이심률과 곡률반경과의 상관관계)

  • Han, Sun-Hee;Kim, Bong-hwan;Park, Jun-Sung;Baek, Su-won;Kwon, Sung Jin;Kim, Eun Kyoung;Yoon, Jung Na;Choi, So Min;Heo, A Jeong;Park, Eun Hye
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.4
    • /
    • pp.662-670
    • /
    • 2016
  • Purpose. Because of a recent increase in use of soft contact lens at younger ages, in the present study, the correlation between corneal eccentricity and radius of curvature and fitting types of contact lens was investigated. Methods. The study evaluated the fitting status of targets through lens centration, push-up test, dynamic lag test and static lag test of lenses usually worn by 49 men and women (98eyes) in their 20s to 30s who put on soft contact lenses. After evaluation, the subjects were classified into 3 categories by fitting status(steep, aligment and flat). The radius of corneal curvature in the naked eyes was measured by using keratometer. Moreover the corneal eccentricity in the nasal side, temporal side, superior side and inferior side was measured by using the device capable of measuring the corneal eccentricity. Results. The radius of corneal curvature and corneal eccentricity of soft lenses worn by subjects were higher in the order of steep fitting and flat fitting, and the higher average corneal curvature radius and corneal eccentricity is intend to be more steep fitting(p=0.051, p=0.052). The corneal eccentricity showed a tendency to nasal fitting type at the higher eccentricity and temporal fitting type at the smaller eccentricity, statistically significant difference was observed(p<0.05). The study showed there were low correlation that nasal and temporal side at steep fitting, superior side at normal fitting and 4side(nasal, temporal, superior, inferior) at flat fitting, therefore when the corneal eccentricity changed the radius of corneal curvature also changed. The corneal eccentricity and the radius of corneal curvature showed statistically significant difference at 4side and each fitting types(p<0.05). Conclusions. The results of this study, the fitting status, of wearer are based on radius of corneal curvature and corneal eccentricity, and if lens fitting would be done considering that, it seems to be useful in a soft contact lens prescription.

Subjective Symptoms according to Fitting Test in Soft Contact Lens Wearers (소프트콘택트렌즈 착용자의 피팅 상태 확인 유무에 따른 자각적 증상)

  • Kim, Jung-Hee;An, Youngju
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.431-442
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate subjective symptoms according to the wearing, purchase and fitting status of soft contact lens wearers, and consumer perception of base curve. Methods : A survey was conducted for those who visited optical shops and lens shops in Seoul from June to August 2018. A total of 98 answer sheets they submitted were used for the analysis. The chi-square test and Fisher's exact test were used to compare subjective symptoms (dryness, glare, uncomfortable fitting, and decreased vision) according to whether fitting condition is screened (case history and push-up test, ect relevant to wearing sensation), and the odds ratio (OR) was obtained by the logistic regression analysis. Results : When the contact lenses were purchased, the rate of which the visual acuity test was performed was 86.6% at optical shop and 64.7% at lens shop. When purchasing contact lens and the contact lens was not tested for fitting, they more experienced dryness (OR 4.41, 95% CI 1.25-15.62) and uncomfortable fitting (OR 2.68, 95% CI 1.08-6.64) than testing for fitting. In addition, it was investigated that 87.8% of contact lens wearers did not know about the term base curve, 92.9% did not listen to an explanation related to the base curve when purchasing contact lenses, and 96.9% did not experience with base curve test. Conclusion : It would be thought that satisfaction of the contact lens fitting of existing consumers should be improved by changing a proper base curve by confirming the fitting condition when prescribing soft contact lens.

Application of Linear Curve Fitting Methods for Slug Test Analysis in Compressible Aquifer (압축성이 큰 지반에서 순간변위(충격)시험 해석을 위한 선형 커브피팅법(Linear Curve Fitting Methods)의 적용)

  • Choi, Hang-Seok;Lee, Chul-Ho;Nguyen, The Bao
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.11
    • /
    • pp.99-107
    • /
    • 2007
  • The linear curve fitting methods such as the Hvorslev method and the Bouwer and Rice method provide a rapid and simple means to analyze slug test data for estimating in-situ hydraulic conductivity (k) of geologic material. However, when analyzing a slug test in a relatively compressible aquifer, these methods have difficulties in fitting a straight line to the semi-logarithmic plot of the test data that shows a concave-upward curvature because the linear curve fitting methods ignore the role of the compressibility or specific storage ($S_s$) of an aquifer. The comparison of the Hvorslev method and the Bouwer and Rice method is made far a partially-penetrating well geometry to show analytically that the Hvorslev method estimates higher hydraulic conductivity than the Bouwer and Rice method except that the well intake section locates very close to the bottom of the aquifer. The effect of fitting a straight line to the slug test data is evaluated along with the dimensionless compressibility parameter (${\alpha}$) ranging from 0.001 to 1. A modified linear curve fitting method that is expanded from Chirlin's approach to the case of a partially penetrating well with the basic-time-lag fitting method is introduced. A case study for a compressible glacial till is made to verify the proposed method by comparing with a type curve method (KGS method).