• 제목/요약/키워드: fissure

검색결과 399건 처리시간 0.029초

전북지역 치과개원의의 열구전색제 사용실태에 관한 연구 (A STUDY OF ATTITUDES TOWARD AND USE OF PIT AND FISSURE SEALANTS BY DENTISTS IN CHON-BUK AREA)

  • 김재곤;백병주
    • 대한소아치과학회지
    • /
    • 제21권2호
    • /
    • pp.429-438
    • /
    • 1994
  • Since the introduction of pit and fissure sealants in the early 1970's, many studies have been published amply documenting the efficacy of these materials as caries-preventive agents. However, the acceptance of the technique by dentist has been questionable. This survey was investigated the attitudes toward and use of pit and fissure sealants by dentist in Chonbuk area. The results were as follows: 1. Utilization of pit and fissure sealants is very high. Only 15% of dentists never use pit and fissure sealants, whereas 85% generally use pit and fissure sealants. 2. Most dentists reported that their knowledge of pit and fissure sealants was gained through dental schools education. 3. Concern about difficult to sell' to patient, poor retention of pit and fissure sealants and unsubstantiated by research were given as the main reasons why pit and fissure sealants was not used. 4. Patient demands and various educate program were given as important factors that would lead to increase use of pit and fissure sealants.

  • PDF

Effects of the earth fissure on the seismic response characteristics of a nearby metro station

  • Jiang Chang;Yahong Deng;Huandong Mu
    • Earthquakes and Structures
    • /
    • 제24권1호
    • /
    • pp.53-64
    • /
    • 2023
  • Earth fissures with several kilometers will inevitably approach or cross the metro line, significantly threatening the safety of the underground structure in the earth fissure site. However, the influence of the earth fissure site's amplification effect on the metro station's dynamic response is still unclear. A representative earth fissure in Xi'an was taken as an example to establish a numerical model of a metro station in the earth fissure site. The dynamic response characteristics of the metro stations at different distances from the earth fissure under various seismic waves were calculated. The results show that the existence of the earth fissure significantly amplifies the dynamic response of the nearby underground structures. The responses of the axial force, shear force, bending moment, normal stress, horizontal displacement, inter-story drift, and relative slip of the metro station were all amplified within a specific influence range. The amplification effect increases with the seismic wave intensity. The amplification effect caused by the earth fissure has relatively weak impacts on the axial shear, shear force, bending movement, normal stress, and horizontal movement; slightly larger impacts on the inter-story drift and acceleration; and a significant impact on the relative slip. The influence ranges of the axial force and normal stress are approximately 20 m. The influence ranges of the acceleration and inter-story drift can reach 30 m. Therefore, the seismic fortification level of the underground structure in the earth fissure site needs to be improved.

치면열구전색의 유지력 (RETENTION OF PIT AND FISSURE SEALANT)

  • 이상호
    • 대한소아치과학회지
    • /
    • 제33권2호
    • /
    • pp.336-347
    • /
    • 2006
  • 치면열구전색은 잘 시행하지 못한 경우 오히려 우식발생을 가릴 수 있어 위험하다. 따라서 치면열구전색의 올바른 적용방법에 대한 이해와 재고가 필요하다. 치면열구전색 시행하기 위해서는 반드시 recall-check이 전제되어야 하는데, 치면열구전색재 시술 환자의 70%가 recall이 되었을 때 병원 경영이 효율적으로 이루어지고 있다는 평가를 내릴 수 있다. 치면열구전색재 도포시 임상가들이 가장 관심 있게 추구하는 2가지 사항은 첫째 치면열구전색재가 소와 및 열구내로 깊숙이 침투하도록 하는 것과 둘째 치면열구전색재와 치면 사이의 gap(변연누출, marginal leakage)을 최소로 발생하게 하는 것이다. 이는 모두 치면열구전색재의 유지력을 좋게 하기 위한 것이며 이는 치면열구전색의 성공/실패와 직결된다. 그러나 탈락되지 않게 할 수는 없어도 더 오랫동안 붙어 있도록 하는 노력은 필요하다. 본 종설에서는 치면열구전색재 유지력을 강화하기 위한 방법으로 치면열구전색재의 재료학적 검토, 유지력에 관계되는 요소, 교합면 소와 및 열구 세척 소와와 열구 내로의 침투도를 높이는 방법, 미세누출을 줄일 수 있는 임상 기술 등에 대해 살펴보고자 하였다. 치면열구전색재의 유지력에 관여되는 요소가 매우 많고 다양하므로 이에 대한 기본적인 이해와 함께 도포 과정에서의 술자의 섬세함과 정성이 전제되어야 한다.

  • PDF

한국 성인 여성 집단에서 검열과 안구돌출의 상관관계 (Correlation between Palpebral Fissure and Exophthalmos in Korean Adult Women Population)

  • 김덕훈
    • 한국임상보건과학회지
    • /
    • 제2권1호
    • /
    • pp.17-23
    • /
    • 2014
  • Purpose. This study was to investigate the relationship between the palpebral fissure size and the exophthalmos in a population of Korean adult women subjects with normal eye status. Methods. From November 2012 to September 2013, The authors analyzed the morphological values in 73 Korean adults population. The test was performed using the Hertel exophthalmometer and verner califer. Analysis of subjects data were recorded using the spss version 20.0 a statistical program (IBM Co, Armonk, NY USA). Results. The average age of the 73 subjects (146 eyes) was (21.219+/-0.261)mm. the average value of palpebral fissure was (25.110+/-1.646)mm in width and (8.096+/-1.464)mm in height. The average value of exophthalmos was (15.002+/-1.922)mm. There was a significant relationship(P>0.05) in the average size between the width and height in palpebral fissure. Also, there was a significant relationship(P>0.05) in the average size between the palpebral fissure width and exophthalmos. On the other hand, there was a significant relationship(P>0.01) in the average size of palpebral fissure height and exophthalmos. Conclusions: In this study, these results suggested that the palpebral fissure and exophthalmos had a significant relationship in the average value of size in Korean adult women population.

한국노인여성의 검열과 안구돌출의 상관관계 (Correlation between Palpebral Fissure and Exophthalmos of The Elder Women in Korea)

  • 김덕훈
    • 한국임상보건과학회지
    • /
    • 제3권3호
    • /
    • pp.427-434
    • /
    • 2015
  • Purpose: This study was to investigate the relationship between the palpebral fissure and the exophthalmos in an elder women population in Korea subjects with normal eye status. Methods. From November 2014 to July 2015, The author analyzed the morphological values in 81 Korean elder women population. The clinical test was performed using the Hertel exophthalometer and verner califer. Analysis of data were described using the spss 20 and Pearson's test. Results. The mean age of the 81 subjects (162 eyes) was (73.938+/8.585)mm. The mean value of palpebral fissure was (5.673+/-2.065)mm in width and (24.179+/-4.409)mm in height. The mean value of exophthalmos was (5.537+/-2.151)mm. There were a significant relationship(P>0.01) in the mean size between the width and height in palpebral fissure. Also, there were a significant relationship(P>0.01) in the mean size between the palpebral fissure width and exophthalmos. Also, there were a significant relationship(P>0.01) in the mean size between the palpebral height width and exophthalmos. However, there were not significant relationship(P>0.01) in the mean size between the palpebral fissure width and exophthalmos in right eye. On the other hand, The relationship between right eye and left eye of the palpebral fissure and exophthalmos was similar results. Conclusions. In this study, these results suggested that the palpebral fissure and exophthalmos was a significant relationship in the mean value of morphologic characters in Korean elder women population.

A Statistical Analysis of Superior Orbital Fissure Width in Korean Adults using Computed Tomography Scans

  • Park, Yongsik;Kim, Youngjoon
    • 대한두개안면성형외과학회지
    • /
    • 제18권2호
    • /
    • pp.89-91
    • /
    • 2017
  • Background: The superior orbital fissure is a small area that connects the middle cranial fossa and the orbit. Many studies have measured the size of the superior orbital fissure. However, there is no standard value for the size of the superior orbital fissure. Therefore, we conducted this study to provide the average size of the superior orbital fissure in Korean adults. Methods: We measured the widths of the superior orbital fissures of 142 patients using computed tomography scans. Because the width of the superior orbital fissure varies at different locations, we measured the superior orbital fissure width at the level of the optic canal. Results: In the males, the width of the superior orbital fissure on both sides was $3.79{\pm}0.93mm$, and these values were $3.79{\pm}0.96mm$ for the left side and $3.783{\pm}0.92mm$ for the right side. In the females, the widths of the superior orbital fissures were $3.62{\pm}1.35mm$ on the left side, $3.69{\pm}1.18mm$ on the right side, and $3.65{\pm}1.26mm$ across both sides. Conclusion: There were no significant differences between the males and females or between the left and right sides. The present study suggests that we may accept the hypothesis that a congenitally narrow superior orbital fissure may be a risk factor for the superior orbital fissure syndrome. Surgeons should take precaution with patients who have narrow superior orbital fissures during the perioperative period.

안검열 비대칭에 관한 연구 (Prevalence of Palpebral Fissure Asymmetry in Healthy Koreans)

  • 김상문
    • 한국안광학회지
    • /
    • 제4권2호
    • /
    • pp.119-122
    • /
    • 1999
  • 조사대상 61명의 primary gaze, $45^{\circ}$ right gaze 및 $45^{\circ}$ left gaze때의 안검열폭을 측정하였다. 안검열폭의 비대칭 판정기준을 1mm 이상으로 하였을 때 생리적 안검열폭 비대칭의 prevalence는 primary gaze에 서 13.1%(8/61), right gaze에서 24.6%(15/61) 그리고 left gaze에서 16.4%(10/61) 이었다. Primary gaze에서 안검열폭의 비대칭 값을 보정한 후 two-tailed trivariate analysis를 실시한 결과 horizontal gaze에서 대부분의 경우 보정된 안검열폭 비대칭 값은 1mm 이하였고 내전안의 폭이 더 넓어지는 경향을 보였다. 동시에 이러한 효과는 right gaze와 left gaze때에 동일하게 나타났고 성에 따라 유의성 있는 차이가 없었다. 내전 안에서 안검열폭의 평균 증가는 right gaze 때에 0.29mm이고 left gaze 때에 0.21mm이었다.

  • PDF

Assessment of seismic damage on frame structures across the earth fissure under earthquake

  • Xiong, Zhongming;Huo, Xiaopeng;Chen, Xuan;Xu, Jianjian;Xiong, Weiyang;Zhuge, Yan
    • Earthquakes and Structures
    • /
    • 제18권4호
    • /
    • pp.423-435
    • /
    • 2020
  • An accurate evaluation of structural damage is essential to performance-based seismic design for the structure across the earth fissure. By comparing the calculation results from three commonly used damage models and the experimental results, a weighted combination method using Chen model was selected in this paper as the seismic damage evaluation. A numerical model considering the soil-structure interaction (SSI) was proposed using ABAQUS software. The model was calibrated by comparing with the experimental results. The results from the analysis indicated that, for the structure across the earth fissure, the existence of earth fissure changed the damage distribution of the structural members. The damage of structural members in the hanging wall was greater than that in the foot wall. Besides, the earth fissure enlarged the damage degree of the structural members at the same location and changed the position of the weak story. Moreover, the damage degree of the structure across the earth fissure was greater than that of the structure without the earth fissure under the same excitation. It is expected that the results from this research would enhance the understanding of the performance-based seismic design for the structure across the earth fissure.

Hydro-mechanical coupling behaviors in the failure process of pre-cracked sandstone

  • Li, Tingchun;Du, Yiteng;Zhu, Qingwen;Ren, Yande;Zhang, Hao;Ran, Jinlin
    • Geomechanics and Engineering
    • /
    • 제24권6호
    • /
    • pp.573-588
    • /
    • 2021
  • The interaction of cracks and water significantly affects the fracture mechanism of rocks. In this study, laboratory tests were conducted using sandstone samples containing a single fissure to explore the hydro-mechanical behaviors in the failure process of pre-cracked rocks. The internal crack characteristics were also analyzed using X-ray CT scanning. The results show that the confining pressure has the greatest effect on the mechanical properties (e.g., strengths, elastic modulus, and Poisson's ratio), followed by the fissure inclination and water pressure. At a lower fissure inclination, the confining pressure may control the type main cracks that form, and an increase in the water pressure increases the number of anti-wing cracks and the length of wing cracks and branch cracks. However, the fracture behaviors of samples with a higher fissure inclination are only slightly affected by the confining pressures and water pressures. The effect of fissure inclination on the internal crack area is reduced with the propagation from the fissure tips to the sample ends. The fissure inclination mainly affects the value of permeability but not affect the trend. The impact of pre-existing fissure on permeability is smaller than that of confining pressure and water pressure.

안와골절 정복술 후 발생한 상안와열증후군의 치험례 (Superior Orbital Fissure Syndrome after Repair of Blow Out Fracture)

  • 이영배;김찬우;박대환
    • Archives of Plastic Surgery
    • /
    • 제38권6호
    • /
    • pp.879-882
    • /
    • 2011
  • Purpose: Superior orbital fissure syndrome is a rare neurological complex. Superior orbital fissure syndrome may result from a variety of inflammatory, infectious, neoplastic, iatrogenic, traumatic, vascular cause. The author report a patient who suffered from superior orbital fissure syndrome after inferior orbital wall reduction. Methods: A 26-year-old female suffered from inferior orbital wall fracture with inferior gaze limitation and orbital soft tissue herniation. On posttrauma 10 day, inferior orbital wall was reduced using endoscope and porous polyethylene ($Medpor^{(R)}$) was inserted. On immediate postoperation, she reported that extraocular movement was limited in almost any directions. She underwent exploration surgery to release the presence of extraocular muscle impingement. But, there was no observation of extraocular muscle impingement. On postoperative one day, high-dose steroid therapy was started to release superior orbital fissure syndrome which was defined in postoperative computed tomography. Results: After one month of high-dose steroid therapy, extraocular movement limitations improved progressively in all directions. In four months, extraocular movement recovered completely. Conclusion: Superior orbital fissure syndrome may occur after surgical procedure of orbital wall reduction. Prompt diagnosis and treatment with mega-dose corticosteroid is an effective option for avoiding disaster from compressive syndrome.