• Title/Summary/Keyword: fire-resistant construction

Search Result 94, Processing Time 0.025 seconds

A Experimental Study on the Fire Resistant Performance of the High Strength Concrete with Loading and Unloading test (재하 및 비재하 내화 실험을 통한 고강도콘크리트의 내화성능에 관한 실험적 연구)

  • Kim, Woo-Jae;Kim, Hyun-Bae;Kim, Kyu-Yong;Kim, Young-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.61-64
    • /
    • 2009
  • Recently, the higher buildings are, the stronger concrete are used. Ultra high strength concrete have the possibility of spalling when a fire breaks out. so the fire-resistance performance is necessary to use the ultra high strength concrete on the high-rise building. On this study, the heating test for the concrete with loading/unloading is performed for ultra high strength concrete using nylon fiber. The heating test followed by ISO-834 heating curve on the real-size specimen and the strength of concrete are 60, 80, 100, 200 MPa.

  • PDF

Fire Resistant Performance after Application of Repaired Materials for Fire-Damaged Reinforced Concrete Column (화재피해를 입은 철근콘크리트 단주시험체의 보수재료 적용 후 내화성능 평가)

  • Sim, Sang-Rak;Ryu, Dong-Woo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.5
    • /
    • pp.147-154
    • /
    • 2020
  • Currently, there are no specific repair methods for RC structures damaged by fire, and repair methods are applied when durability deteriorates due to aging. In addition, a number of recent studies have been reported that have conducted fire resistance assessment of the repair materials themselves, assuming exposure to high-temperature environments such as fires. However, researches that evaluate the fire resistance performance of the repair materials by applying existing repair materials to the actual fire damaged reinforced concrete structures are very rare. Therefore, in this study, a number of existing repair materials were applied to fire-damaged concrete column to compare and evaluate the fire resistance performance with the original cover concrete.

Fire Performance Analysis of SLIM AU Composite Beam (슬림 AU 합성보의 내화해석)

  • Kim, Myeong-Han;Oh, Myoung-Ho;Min, Jeong-Ki
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.4
    • /
    • pp.133-140
    • /
    • 2016
  • SLIM AU(A plus U-shaped) composite beam had been developed for not only reducing the story height in residential and commercial building, but also saving the cost of floor construction. The structural performance and economic feasibility was sufficiently approved by means of structural experiments and analytical studies. Even though fire resistance of the SLIM AU composite beam was evaluated throughout furnace fire test, the fire performance of the composite beam using finite element analysis is not analysed yet. Therefore the predictions of fire resistance simulations with loading as well as temperature distribution of the composite beam are summarized in this paper.

Advanced concrete for Skyscraper (초고층 구조물을 위한 특수 콘크리트)

  • Cho, Yun-Gu
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.106-111
    • /
    • 2008
  • Advanced concrete technology, which is the main construction technology of skyscraper, is dealt with in this paper. Advanced concrete technologies are classified into several types such as super high strength concrete(SHSC), low heat concrete(LHC), fire resistant concrete(FRC) and blast resistant concrete(BRC). The necessity, principal and application examples of advanced concrete technology are described respectively. In the last part of the paper, the introduction of HYUNDAI E&C's technology of Advanced concrete and future research trend are described.

  • PDF

Field Application of 80MPa High Strength Fire Resistant Concrete using Ternary Blended Cement (설계강도 80MPa 3성분계 고강도내화콘크리트의 현장적용 및 성과분석)

  • Kim, Seong-Deok;Kim, Sang-Yun;Bae, Ki-Sun;Park, Su-Hee;Lee, Bum-Sik
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.5
    • /
    • pp.113-119
    • /
    • 2010
  • Fire resistance and field tests for high-strength concrete(HSC) of 80MPa were carried out to evaluate whether or not it shows the same material properties even in the field condition of being mass-produced and supplied. As a result, it was found that fire resistant HSCs containing composite fiber(NY, PP) of 0.075% have great resistance to fire and spalling. In the field test, before the pumping air contents, slump flow, U-box, L-flow, compressive strength, gap of hydration temperature of interior and exterior of specimen and placing ratio per hour satisfied the required properties of HSC. However, after the pumping of HSC, as slump flow and L-flow were slightly less than required criterion, they need to be improved. In terms of hydration temperature of HSC, it was found to satisfy the related criterion. Packing ability as well as placing ratio per hour of HSC, which was about $44m^3$, show outstanding results. If slump flow of developed ternary HSC is improved after the pumping it can be useful for the construction of high-rise buildings.

Study on the Design Automation of Steel House Shop drawing (스틸하우스 설계 자동화의 필요성과 적용방법에 관한 연구)

  • Won, Wan-Youn;Park, Hyeon-Soo
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.103-106
    • /
    • 2006
  • This study proposes a method of generating steel house shop drawing in an automated design method, reducing construction manpower and period. With one hour fire-resistant approval code, reflecting work ability and efficiency, steel-framed house market is expected to extend from one or two story house to multi-purpose facilities up to four story height. More models have been constructed in this system than the first appearance of fire-resistant approval in Korea in 1997. Also, cost estimation of components such as frame walls, roof trusses and floors is obtained with shop drawings. Also, the lack of suppliers of steel framed house shop drawing and unstandardized drawing method get constructors have difficulty in understanding its design. In steel framed house industry, shop drawings are essential part in building and constructing framework and they have major effects on construction deadlines and expenses. By exploring method of shop drawing automation, this study aims to optimize work flow with a standardized drawing method. The proposed system can be applied to manufacturing automation in domestic industry of factory-built panelizing method in the near future.

  • PDF

A Study on Data Research for Fire Regulations and Fire Retardant in Interior Architecture (실내건축관련 소방(消防)규정과 방염(防炎)에 관한 연구)

  • Cho, Sung-O;Kim, Yong-Sung
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.95-102
    • /
    • 2010
  • Recently, a grow in size and features of Interior construction work over the complex and The Fire-related regulations have been strengthened for the prevention of fire damage. This study is purpose to propose interior design, construction and supervision for the efficient and reasonable way throughout the fire-related laws are investigated in interior architecture. First, the interior of the building work will be based on actual use Fire-related Laws and Regulations have be investigated. Second, based on analysis of material and facilities by Application can be used in production by the data were applied to the present. Third, the international Fire and Flame Retardant Standards for investigating and reviewing the relevant laws, differences and characteristics of each country were analyzed. Fourth, the various fire-related issues of regulation and the application of relevant provisions in the field works, the law's standards, and improvements were identified by analysis. Fire-Related Laws and Building codes that Safety Administration of the Fire Services are divided into design, it comes to approval from the municipal authorities with concerns about the fire that will fit on the Fire Department's administrative procedures and operations is necessary to integrate operations. In conclusion, Fire-related business are divided into Minister of Land, Transport and Maritime Affairs and Ministry of Public Administration and Security. So, Both institutions is need to be the cooperative work. It is necessary to the field supervision. Because, Flame-resistant performance standards in the field works applied are too complex. Last, Establishment of fire-related regulations will enact by private organizations and the experts to participate.

Study on the Fire Resistance of Light Weight Inorganic Polymer Concrete Panel Wall (Inorganic Polymer Concrete를 이용한 경량패널의 내화특성에 관한 실험적 연구)

  • Hwang, Ji-Soon;Kim, Woo-Jae;Kim, Dae-Hoi;Park, Dong-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.205-206
    • /
    • 2011
  • Inorganic Polymer Concrete, a type of Alkali activated cement and concrete, is known for various excellent performances, especially for better performance in the area of high temperature heat resistance(thermal characteristic) than portland cement concrete.In this study, light weight concrete panel was manufactured using this Inorganic Polymer Concrete and then evaluated for fire resistance with a small-scale heating furnace. Since the result showed excellent fire resistance, it is considered usable for manufacturing fire resistant concrete panel wall.

  • PDF

Structural performance of unprotected concrete-filled steel hollow sections in fire: A review and meta-analysis of available test data

  • Rush, David;Bisby, Luke;Jowsey, Allan;Melandinos, Athan;Lane, Barbara
    • Steel and Composite Structures
    • /
    • v.12 no.4
    • /
    • pp.325-350
    • /
    • 2012
  • Concrete filled steel hollow structural sections (CFSs) are an efficient, sustainable, and attractive option for both ambient temperature and fire resistance design of columns in multi-storey buildings and are becoming increasingly common in modern construction practice around the world. Whilst the design of these sections at ambient temperatures is reasonably well understood, and models to predict the strength and failure modes of these elements at ambient temperatures correlate well with observations from tests, this appears not to be true in the case of fire resistant design. This paper reviews available data from furnace tests on CFS columns and assesses the statistical confidence in available fire resistance design models/approaches used in North America and Europe. This is done using a meta-analysis comparing the available experimental data from large-scale standard fire tests performed around the world against fire resistance predictions from design codes. It is shown that available design approaches carry a very large uncertainty of prediction, suggesting that they fail to properly account for fundamental aspects of the underlying thermal response and/or structural mechanics during fire. Current North American fire resistance design approaches for CFS columns are shown to be considerably less conservative, on average, than those used in Europe.

The fire-risks of cost-optimized steel structures: Fire-resistant and hot-rolled carbon steel

  • Garcia, Harkaitz;Cuadrado, Jesus;Biezma, Maria V.;Calderon, Inigo
    • Structural Engineering and Mechanics
    • /
    • v.78 no.1
    • /
    • pp.67-75
    • /
    • 2021
  • This work studies the behaviour of a steel portal frame selection under fire exposure, considering both span lengths and fire exposure times as variables. Such structures combine carbon steel (S275), fireproof micro-alloyed steel (FR), and coatings of intumescent paint with variable thicknesses, improving thereby the flame retardant behaviour of the steel structure. Thus, the main contribution of this study is the optimization of the portal frames by combining both steels, analysing the resulting costs influence on the final dimensions. Besides, the topological optimization of each steel component within the structure is also defined, in accordance with the following variables: weather conditions, span, paint thickness, and cost of steel. The results mainly confirmed that using both FR and S275 grades with intumescent painting is the Pareto optimum when considering performance, feasibility and costs of such portal frames widely used for industrial facilities.