• 제목/요약/키워드: fire-resistance design

검색결과 213건 처리시간 0.029초

폐콘크리트 순환자원을 이용한 건설재료의 화재내력 및 단열성에 관한 실험적 연구 (Experimental Study on Fire Resistant Capacity and Thermal Conduction of Construction Material Using the Circulation Resources)

  • 최재남;홍세화;손기상
    • 대한안전경영과학회지
    • /
    • 제12권3호
    • /
    • pp.121-128
    • /
    • 2010
  • This is to show some basic data for introducing both circulated aggregate and recycled powder producing waste concrete. Standard-mixing design for 24MPa has been basically used and added and replaced normal aggregate with recycled powder made of waste concrete. In addition, polycarboxylate high-range water reducing agent has been used because recycled powder is missing adhesive strength and it is not compare with cement's adhesive strength. Compressive strength with powder mixture of 2%, 4%, 6%, 8%, and 10% has been decreased down to 80% of normal concrete material strength without recycled powder mixture. $200^{\circ}C$, $400^{\circ}C$ and $600^{\circ}C$ heated concrete were compressively tested in order to find out concrete strength resistant to high temperature. heat capacity was also tested, based on the expectancy of its low conductivity. In addition, thermal conduction test was tested in order to find out concrete insulation. According to this test, when concrete was tested by fire resistance, it using the circulation aggregate was same resulted by concrete using the natural aggregate. also, recycle powder was not effecting insulation performance. but it is fit to standard on concrete insulation of building law.

Shenzhen Rural Commercial Bank Headquarters: an Iconic Tower Defined by the Integration of Architecture, Structure and Sustainability Goals

  • Besjak, Charles;Thewis, Alexandra
    • 국제초고층학회논문집
    • /
    • 제11권1호
    • /
    • pp.31-39
    • /
    • 2022
  • The seamless integration of the architecture and structure of a tall building plays a key role in establishing a recognizable and iconic design. The structural system developed for Shenzhen Rural Commercial Bank Headquarters (SRCBH) utilizes enhanced structural innovations unique to the tower's geometry to improve structural and sustainability performance. SRCBH utilizes a steel diagrid system pulled outside of the enclosure line with diaphragm forces resolved primarily by corner diagonal beams. During the design process the structural systems underwent performance based design and optimization for wind and seismic loading. Resiliency was prioritized for structural design as well as fire resistance. More closely integrating the structure of a building with its architecture and sustainability goals can lead to unique and innovative towers with a timeless expression.

전기 히터의 형상에 따른 시뮬레이션 열 해석 연구를 통한 융합 기술 연구 (Convergence Technique Study through Simulation Thermal Analysis due to the Shape of Electric Heater)

  • 이정호;조재웅
    • 한국융합학회논문지
    • /
    • 제6권6호
    • /
    • pp.241-246
    • /
    • 2015
  • 추운 겨울철 실내를 따뜻하게 해주는 발열 및 난방기구들은 필수적인 요소이며, 2000년대부터 이러한 난방기구들의 사용량은 급격하게 증가하고 있다. 하지만, 화재 사고와 화재의 위험성 역시 증가하고 있다. 따라서 본 연구에서는 보다 안전한 난방기구의 설계를 위하여 시중에서 판매되는 세라믹, 카본 및 근적외선 히터들로서의 세 가지 형상의 전기히터들을 참고하여 3D 모델링하였으며, 이들 모델들을 가지고 열 해석을 수행하여 열변형량과 열응력 등에 따른 내구성을 연구하였다. 본 연구에서 도출된 연구 결과들을 바탕으로 각 형상에 따른 전기히터 모델들의 내구성을 예측할 수 있었고, 궁극적으로 보다 안전한 내화성이 있는 새로운 난방기구의 개발에 기여할 수 있었다. 또한 디자인 면에서 융합 기술로의 접목도 가능하여 미적인 감각을 나타낼 수 있다.

강섬유 콘크리트 혼입율에 따른 내부앵커형 콘크리트 충전기둥 내화성능에 관한 해석적 연구 (Analysis Study on Fire Performance with Internal Anchored Concrete Filled Steel Tube Columns According to Percent of Steel-Fibers)

  • 김선희;염경수;김용환;최성모
    • 한국강구조학회 논문집
    • /
    • 제28권1호
    • /
    • pp.23-34
    • /
    • 2016
  • 콘크리트 충전강관 기둥은 강관의 구속효과에 의해 콘크리트의 압축내력 상승과, 콘크리트에 의한 강관의 국부좌굴 보강효과에 의해 부재내력이 상승하고 뛰어난 변형성능을 발휘한다. 하지만, 기둥단면이 커질 경우 합성효과를 발휘하기 위하여 스터드 볼트나 후 시공 앵커 볼트를 사용해야 하는 시공상의 문제점이 발생된다. 이를 극복함과 동시에 합성효과를 증대시키기 위한 방안으로 내부에 리브가 설치된 용접조립 기둥이 소개되었다. 내부 리브는 콘크리트와 맞물려 있어 리브의 변형은 콘크리트의 균열을 촉진시키는 역할을 동반하게 된다. 이러한 잠재적인 문제에 대한 해결책은 강관 리브의 변형에 저항할 수 있도록 콘크리트 인성을 증가시킬 수 있는 방안이 필요하다. 언급된 두 가지의 문제점이 효과적으로 해결될 경우 용접조립 각형강관 기둥은 내화성능 확보가 가능하다고 판단된다. 본 연구에서는 해결방안으로 내부 콘크리트를 강섬유와 혼입하여 기둥 자체의 연성과 인성을 증대시키는 것에 중점을 맞추고 있다. 내화성능 평가를 위한 시험체는 총 8개 로 하중비에 따른 재하가열 실험을 실시하고 화재 전후 거동과 열 변형 능력을 주요변수별로 분석하였다. 실험결과와 선행연구 비교를 통해 열 전달과 열응력 해석 모델의 신뢰성을 확보하였으며, 강섬유 혼입율에 따른 변수해석을 수행하였다.

TRIZ기법에 의한 물류창고의 화재원인 및 4M에 따른 예방대책 분석 (Classification of Fire Causes in Warehouses Using the TRIZ Technique and Analysis of Preventive Measures Accordingto 4M)

  • 한상훈;공하성
    • 문화기술의 융합
    • /
    • 제6권3호
    • /
    • pp.401-412
    • /
    • 2020
  • 이 연구는 TRIZ기법에 의한 물류창고 화재의 원인분석과 4M을 적용하여 화재예방대책을 제시하였다. 연구결과는 다음과 같다. 첫째, 창의적 문제해결기법인 TRIZ기법을 적용하여 물류창고 화재원인의 모순을 제시하였다. 둘째, 인적 요인, 물류창고의 화재대책으로 관리자의 안전 기준, 근로자 안전의식 강화, 샌드위치 패널의 작업자 시공기술 강화 등을 방안을 분석하였다. 셋째, 기계, 설비적 요인, 물류창고의 화재대책으로 안전시설, 안전장치 확대 설치, 화재 진압장비 도입 및 개발, 샌드위치 패널의 내화성능 향상방안을 제시하였다. 넷째, 작업, 환경적 요인, 물류창고의 화재대책으로 작업공법에 대한 안전수칙 및 관리감독 강화, 물건 적재 장소에 대한 방화구획설정, 성능위주설계 기반으로 한 방화구획의 설정방안을 제시하였다. 마지막으로, 관리적 요인, 물류창고의 화재예방대책으로 화재 위험도가 낮은 특정소방대상물, 화재안전기준을 적용하기 어려운 특정소방대상물에 샌드위치 패널이 불연재료 이상 재질 규정을 검토, 물류냉동 창고에 스프링클러설비를 설치, 샌드위치 패널 구조인 물류창고에는 바닥면적의 크기와 관계없이 자동설비의 설치를 의무화하되 소급적용하는 방안을 제안한다.

소방관 보조로봇 플랫폼의 내충격성능 향상을 위한 구조 보강 설계 (The Structural Reinforcement Design of Firefighter Assistance Robots for Improving the Impact Resistance)

  • 신동환;김윤구;안진웅
    • 대한임베디드공학회논문지
    • /
    • 제6권5호
    • /
    • pp.273-280
    • /
    • 2011
  • In this paper, we describe the structural reinforcement approach of the throwing-type firefighter assistance robot which can be thrown into a fire site to monitor inside the place and search trapped people while ensuring a firefighter's safety. The reinforcement design is focused on high strength with low weight for the robot. The in-depth structural analysis of the platform is carried out to track down the weakest part, especially with the 1.8m height of drop test. The analysis is verified by comparing with the 1.8m height of the drop test of the throwing-type firefighter assistance robot. The optimal approach for improving the strength of the weakest part aims at topological equivalent and equivalently stress distributed shape.

폭발 후 화재하중 시나리오에 따른 2방향 프리스트레스트 콘크리트 패널부재의 손상도 평가 (Damage Evaluation of Bi-directionally Prestressed Concrete Panels under Blast-fire Combined Loading)

  • 최지훈;최승재;김태균;김장호
    • 콘크리트학회논문집
    • /
    • 제29권3호
    • /
    • pp.237-248
    • /
    • 2017
  • 각종 사고 및 테러로 인한 폭발, 충돌, 화재 사고가 발생함에 따라 사회적인 안전 불감증이 더욱 고조되고 있으나, 실제 극한하중에 대한 구조물의 방호 설계가 반영되지 못하고 있는 실정이다. 특히, 원전격납구조물, 가스탱크 등과 같은 주요 시설물에 적용되고 있는 2방향 프리스트레스트 콘크리트(PSC) 구조물에 대한 폭발, 그리고 폭발로 인한 2차적으로 발생 가능한 화재에 대한 연구가 미흡함에 따라 복합손상 시나리오에 대한 구조물의 검토가 필요하다. 따라서, 본 연구에서는 폭발 후 화재하중 복합손상을 분석하기 위하여 $1,400mm{\times}1,000mm{\times}300mm$의 2방향 비부착 프리스트레스트 콘크리트를 제작하여, 폭발하중은 ANFO 25 kg의 장약량을 1.0 m 이격거리로 실험을 구성하고, 화재하중은 5분 이내에 $1,200^{\circ}C$의 화재하중을 가할 수 있는 RABT 화재시나리오를 적용하여 극한저항성능을 검토하였다. 본 연구는 향후 국내외 프리스트레스트 콘크리트에 대한 방호설계 및 폭발해석 등 관련 연구분야의 중요한 자료가 될 것이라 판단된다.

도로터널 화재시 열부력이 제연용 제트팬 댓수에 미치는 영향에 대한 해석적 연구 (A numerical study on effects of thermal buoyance force on number of jet fans for smoke control)

  • 유지오;신현준
    • 한국터널지하공간학회 논문집
    • /
    • 제15권3호
    • /
    • pp.301-310
    • /
    • 2013
  • 현재 도로터널에는 화재시 임계풍속을 유지할 수 있도록 제트팬을 설치하고 있으며, 제트팬 댓수는 임계풍속을 유지하기 위한 유동저항, 자연풍에 의한 환기저항, 열부력에 의한 환기저항을 고려하여 산정한다. 그러나, 국내의 경우, 제트팬 댓수 산정시 열부력은 고려하지 않고 있는 실정이다. 이에 본 연구에서는 열부력이 제트팬 댓수에 미치는 영향을 검토하기 위해서 터널연장(500, 750, 1000, 1500, 2000, 3500 m) 및 경사도(-1.0, -1.5, -2.0%)를 변수로 하여 화재성장곡선에 따른 비정상상태의 수치 시뮬레이션을 수행하였으며, 열기류의 평균온도 및 열부력에 의한 압력손실을 검토하여 열부력이 제트팬 댓수에 미치는 영향을 검토하였다. 이에 본 연구에서는 화재로 인한 열부력을 고려하는 경우에 제트팬 댓수의 증가가 필요하며, 특히, 설계화재강도를 100 MW로 하는 경우에는 본 해석조건의 모든 범위에서 열부력에 의한 압력손실이 차량저항에 의한 압력손실의 최대치보다 증가하며, 현행설계기준을 적용하는 경우보다. 최소 2~11대의 제트팬 대수의 증가가 필요한 것으로 분석되었다. 따라서 제연용 제트팬 용량 산정시 열부력에 대한 고려가 반드시 필요한 것으로 나타났다.

SCBA 면체용 다자간 동시 양방향 팀 통신모듈 개발 (Development of Multipoint Simultaneous Full-duplex Team Communication Module for SCBA)

  • 김시국;최수길;임우섭;한용택
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.165-172
    • /
    • 2019
  • 본 연구는 소방대원들이 화재현장에서 진압 및 구조 업무 활동 시 필수로 착용하고 있는 SCBA 시스템에 팀원 간 의사소통이 가능하도록 다자간 동시 양방향 통신이 적용된 SCBA 면체용 무선통신 모듈을 설계·제작하여 그 성능을 확인하였다. 본 시험 조건에서 팀 통신모듈 성능평가결과 가시거리(LOS)에서 500 m 이상 통신이 가능하며, 건축물 내부 수평 통신거리는 1:1로 최소 36 m에서 최대 51 m까지 측정되었다. 또한, Ad-hoc 기능을 구현하여, 3 hoc 자동중계로 통신거리가 128 m 까지 확대되었다. 건축물 내부 수직 통신거리는 오픈된 계단실의 경우 5층까지, 구획된 계단실의 경우 3층까지 통신되었고, 2 hoc 자동중계를 통해 5층까지 모든 통신이 가능하였다. 화재상황을 가정한 통신 성능실험결과 별도의 PTT 키 조작 없이도 소방무선통신 표준약어를 5명의 팀원이 정확히 인지하는 것을 확인할 수 있었다. 추가적으로 불꽃저항성 실험결과 950 ± 50 ℃의 불꽃에 5 s간 노출 후 즉시 소화되어 내염성을 지닌 것을 확인할 수 있었다.

Water-blocking Asphyxia of N95 Medical Respirator During Hot Environment Work Tasks With Whole-body Enclosed Anti-bioaerosol Suit

  • Jintuo Zhu;Qijun Jiang;Yuxuan Ye;Xinjian He;Jiang Shao;Xinyu Li;Xijie Zhao; Huan Xu;Qi Hu
    • Safety and Health at Work
    • /
    • 제14권4호
    • /
    • pp.457-466
    • /
    • 2023
  • Background: During hot environment work tasks with whole-body enclosed anti-bioaerosol suit, the combined effect of heavy sweating and exhaled hot humid air may cause the N95 medical respirator to saturate with water/sweat (i.e., water-blocking). Methods: 32 young male subjects with different body mass indexes (BMI) in whole-body protection (N95 medical respirator + one-piece protective suit + head covering + protective face screen + gloves + shoe covers) were asked to simulate waste collecting from each isolated room in a seven-story building at 27-28℃, and the weight, inhalation resistance (Rf), and aerosol penetration of the respirator before worn and after water-blocking were analyzed. Results: All subjects reported water-blocking asphyxia of the N95 respirators within 36-67 min of the task. When water-blocking occurred, the Rf and 10-200 nm total aerosol penetration (Pt) of the respirators reached up to 1270-1810 Pa and 17.3-23.3%, respectively, which were 10 and 8 times of that before wearing. The most penetration particle size of the respirators increased from 49-65 nm before worn to 115-154 nm under water-blocking condition, and the corresponding maximum size-dependent aerosol penetration increased from 2.5-3.5% to 20-27%. With the increase of BMI, the water-blocking occurrence time firstly increased then reduced, while the Rf, Pt, and absorbed water all increased significantly. Conclusions: This study reveals respirator water-blocking and its serious negative impacts on respiratory protection. When performing moderate-to-high-load tasks with whole-body protection in a hot environment, it is recommended that respirator be replaced with a new one at least every hour to avoid water-blocking asphyxia.