• Title/Summary/Keyword: fire tolerance

Search Result 23, Processing Time 0.025 seconds

Effects of Forest Fire on the Forest Vegetation and Soil (II) (황폐산지(荒廢山地)에서의 산불이 삼림식생(森林植生) 및 토양(土壤)에 미치는 영향(影響)에 관한 연구(研究)(II))

  • Woo, Bo Myeong;Kwon, Tae Ho;Ma, Ho Seop;Lee, Heon Ho;Lee, Jong Hak
    • Journal of Korean Society of Forest Science
    • /
    • v.68 no.1
    • /
    • pp.37-45
    • /
    • 1985
  • The second year's results of surface fire effects on forest vegetation and soil properties and fire tolerance of various tree species were investigated in Mt. Gwanak, Kyunggi-do, successively after the study of the first year's effect in the same place. Soil moisture contents, organic matters, and most of soil nutrients including exchangeable bases had increased just after fire and went down to become somewhat constant. Available phosphorous at fired area decreased until it became similar to that at unfired area, while pH of subsoil was continuously increasing from just after fire till after 1 year. For Lespedeza and Weigela species, fire tolerance of tree crown was the lowest but reproductive capacity was the highest. And both of them were high for Rhododendron species. More exact classification into Increasers, Decreasers, Invaders and Neutral species was possible in the second year's study. According to comparison of similarities, it was found that the vegetational structure at fired area is slowly restoring to original state as time goes.

  • PDF

A Research of Field Tolerance for Improvement of Fire Fighting Ability in High Rise Structures (고층건축물에서의 소방력 향상을 위한 현장적응성에 관한 연구)

  • Choi, Tae-Young;Park, Nam-Kwun
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.1
    • /
    • pp.47-55
    • /
    • 2012
  • There are currently various domestic high-rise construction projects underway. Such projects may maximize the economic impact, and yield other benefits, however, there is also a possibility of fire, terrorism, and other disasters that one may not even imagine. This study of high-rise structures' damage reduction measures the fire-fighting ability of the fire fighters at the scene of an indoor emergency upon entry. In order to identify the practical limitations, the fire fighter entered from the 1st floor to reach the top 54th floor. 1.Time required to reach the top floor without the respirator 2.Time required as well as pressure consumption to reach the top floor with the respirator equipped was measured; based on the results, performable range of operations during a fire fighting activity were presented.

Effects of Forest Fire on the Forest Vegetation and Soil(IV) (황폐산지(荒廢山地)에서의 산불이 삼림식생(森林植生) 및 토양(土壤)에 미치는 영향(影響)에 관(關)한 연구(硏究)(IV))

  • Woo, Bo-Myeong;Lee, Heon-Ho
    • Journal of Korean Society of Forest Science
    • /
    • v.78 no.3
    • /
    • pp.302-313
    • /
    • 1989
  • To investigate the effects of forest fire on the change of vegetation and soil conditions by the lapse of time, the 5th soil survey and vegetation analysis were carried out in July of 1988 at the rocky areas of Mt. Kwanak, where ground fire broke out 5 years ago. Three-year increasing trends of organic matter content, the value of pH, and total nitrogen content stabilized after the restoration of the vegetation. By the comparison of the occurrences of the species for 5 years after the forest fire, woody and herbaceous plants were categorized into 4 groups, i,e., invasive, sensitive, tolerant, and neutral species to the forest fire. Although such diversity indices as the species diversity and similarity index indicate that the restoration of damaged vegetation to the original species composition was proceeded for the period, the restoration of vegetation to the original crown closure and tree growth was not proceeded yet.

  • PDF

Water Jet Experiment of Automatic Fire-tracking Water Cannon Facility combined with Indoor Hydrant Facility in Road Tunnels (도로터널의 옥내소화전설비 겸용 자동화점추적 방수총설비의 방수실험)

  • Kim, Chang-Yong;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.92-98
    • /
    • 2019
  • To determine if water-jet nozzle moves and water jetting are effective according to the location of the fire, this study examined the automatic fire-tracking water cannon system and aan indoor hydrant system, such as water jet centered directivity, water jet range maintainability and water jet shape uniformity. First, an examination to find the center of fire accurately from this system design showed that the water jet centered test was accurate. Second, the water jet range test results showed that when water is jetted at the maximum water jet radius, the water jet shows an inaccurate result but within the allowable tolerance range. Finally, the water-jet shape test result confirmed that there are no problems in setting the block from the algorithm design.

A Study on Tool Offset for Cutting of the Polyurethane Foam (폴리우레탄폼 절삭가공시 공구보정에 관한 연구)

  • Min, Se-Hong;Kim, Hei-Song
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.2
    • /
    • pp.31-35
    • /
    • 2000
  • After constructing master model utilizing CAD data originated by sketch, product NC data for polyurethane foam using digitized master model data. And model cutting is performed utilizing specially developed polyurethane foam cutting tool in machining center. In this study, it is discussed to construct concept of tool offset, method of tool offset and feature tolerance, etc., that is impossible for cutting of the polyurethane foam by CNC machine.

  • PDF

Design and Performance Analysis of Lateral Type MEMS Inertial Switch (수평 구동형 MEMS 관성 스위치 설계 및 성능해석)

  • Gim, Hakseong;Jang, Seung-gyo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.7
    • /
    • pp.523-528
    • /
    • 2020
  • A lateral type MEMS inertial switch was designed on the same principle as spring-mass system. The MEMS switch is used for arming mechanism of the arm-fire device by sensing the applied acceleration. We analyzed the switching capability of the MEMS switch under various acceleration conditions via performance model. Simulation results showed that the MEMS switch works very well at 10 g when the applied acceleration slope does not exceed 10 g/msec. On the other hand, the threshold operating acceleration level simulation exceeded the requirement (10±2 g) due to the width and length of the spring by considering 10% tolerance of the design values. Design modification of doubling the width of the spring, which is difficult to reduce less than 10% tolerance in fabrication process, was proposed after confirming the simulation results comply the requirement.

Development and Safety Evaluation of Earth Leakage Alarm Breaker Equipped with Fire Current (IGR) Alarming Function (화재전류(IGR) 경보 기능이 내장된 누전경보차단기의 개발 및 안전성 평가에 관한 연구)

  • Ko, Wan-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.43-48
    • /
    • 2020
  • The purpose of this study is to develop an earth leakage alarm circuit breaker, equipped with a leakage alarming function (JER-E2S, ETECKOREA Co., Korea), and to analyze its characteristics. The developed mechanism is exclusively used for single-phase and 220 V circuits, with a rated current of 32 A, 20 A, 20 A (for restrooms), 16 A, etc. It satisfies all characteristics of existing earth leakage circuit breakers (ELB). If a fire current, which is a resistive leakage current (Igr), flows through an electric line, the device detects the leakage current in real time and warns against the leakage through a blinking LED lamp. Since the developed device displays a tolerance to a capacitative leakage current (Igc) that inevitably occurs in LED lamps, communication devices, etc., it ensures a stable power supply. In addition, the earth leakage alarm circuit breaker protects against power failure due to a momentary ground fault. Therefore, it can supply power without the risk of the circuit breaker malfunctioning due to a momentary ground fault caused by water droplets, leaves, etc. Moreover, with a standby power of less than 0.1 W, the developed earth leakage alarm circuit breaker exhibits a power saving performance that is 3~8 times greater than that of other ELBs. Installation of approximately 10 earth leakage alarm circuit breakers in one apartment household, with an area of 120 ㎡, can save 2~5 kWh per month. Therefore, the developed earth leakage alarm breaker not only satisfies the characteristics of existing earth leakage breakers, but also exhibits outstanding power supply quality since it has the functions of electric fire prevention and malfunction prevention. Therefore, this device can innovatively contribute to electric fire prevention.

Review of Crash Landing Load Factor (추락착륙 하중배수에 대한 고찰)

  • Bae, Hyo-gil;Kim, Do-Hyung;Park, Jea Sung
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.1
    • /
    • pp.47-55
    • /
    • 2021
  • When an abnormal landing occurs, aircraft structures should be designed to guarantee occupants survivability without preventing egress. To find out fire root causes at crash, lots of fixed aircraft crash tests were conducted. Appropriate crash load factors were established with the comprehension of structural behavior based on dynamic analysis and investigation of human tolerance. Cargo restraint criteria were set up considering passengers safety and operational cost while analyzing past cargo aircraft accident data using a probabilistic approach. Reviewing results of past crash tests, current crash landing load factor was appreciated physically, medically, and economically.

Reinforcing System(MFRI) for Concrete Structure using FRP ROD & High-performance Mortar (섬유복합재봉(FRP ROD)과 고강도 모르터를 이용한 철근 콘크리트 구조물의 휨 보강공법(MFRI) 공법)

  • Bae Ki-Sun;Park Sing-Hun;Lee Sang-Uk
    • Composites Research
    • /
    • v.18 no.4
    • /
    • pp.59-65
    • /
    • 2005
  • This report is on the Reinforcing System(MFRI) for Concrete Structure using FRP ROD & High-Performance Mortar. The main characteristic of this system is as follow. First, the fiber rods in this system have seven times greater tensile strength than general reinforcing steel bars(re-bar) and the weight is a fifth lighter. Camels coated on the fiber rods' surfaces to improve adhesive strength and pull-out strength. Second, high strength shotcrete mortar is has very good workability and low rebound rate. After installing the Fiber Rods, Shotcrete mortar Is applied or sprayed to finish reinforcement. Finally, MFRI system has excellent fire-resisting performance and sogood tolerance against external environment by inserting fiber rods and reinforcing materials into mortar which has high compressive strength. It is applied to bridge slab, utility box and tunnel of civil engineering works, and beam and slab of building structures.

Design of Occupant Protection Equipment for Passenger Car Using Taguchi Method (다구찌법을 이용한 자동차 승객 보호 장구의 설계)

  • 이권희;주원식;이주영
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.299-304
    • /
    • 2003
  • The design of an occupant protection equipment has been considered as the important process in developing a new car since the crash performance plays an important role on the market. The cost is increased when an unexpected real test is carried out in the proto-design stage. Thus, the exact prediction of a crash performance can reduce the number of full-car test. In this research, the robust design of an airbag system considering the frontal crash is suggested to predict the more reliable responses. On the contrary, most existing researches do not consider the uncertainties. The uncertainties treated in this research are the tolerances of the vent hole, the time to fire and the length of a strap in airbag and the tolerance of the load limiter load in seat belt. The Taguchi method is utilized to determine the robust optimum of each parameter

  • PDF