• Title/Summary/Keyword: fire tests

Search Result 613, Processing Time 0.025 seconds

Determination of limiting temperatures for H-section and hollow section columns

  • Kwon, In-Kyu;Kwon, Young-Bong
    • Steel and Composite Structures
    • /
    • v.13 no.4
    • /
    • pp.309-325
    • /
    • 2012
  • The risk of progressive collapse in steel framed buildings under fire conditions is gradually rising due to the increasing use of combustible materials. The fire resistance of such steel framed buildings is evaluated by fire tests. Recently, the application of performance based fire engineering makes it easier to evaluate the fire resistance owing to various engineering techniques and fire science. The fire resistance of steel structural members can be evaluated by the comparison of the limiting temperatures and maximum temperatures of structural steel members. The limiting temperature is derived at the moment that the failure of structural member results from the rise in temperature and the maximum temperature is calculated by using a heat transfer analysis. To obtain the limiting temperatures for structural steel of grades SS400 and SM490 in Korea, tensile strength tests of coupons at high temperature were conducted. The limiting temperatures obtained by the tensile coupon tests were compared with the limiting temperatures reported in the literature and the results of column fire tests under four types of loading with different load ratios. Simple limiting temperature formulas for SS400 and SM490 steel based on the fire tests of the tensile coupons are proposed. The limiting temperature predictions using the proposed formulas were proven to be conservative in comparison with those obtained from H-section and hollow section column fire tests.

STRUCTURAL TEST AND ANALYSIS OF RC SLAB AFTER FIRE LOADING

  • Chung, Chul-Hun;Im, Cho Rong;Park, Jaegyun
    • Nuclear Engineering and Technology
    • /
    • v.45 no.2
    • /
    • pp.223-236
    • /
    • 2013
  • In the present study the behavior of fire and the residual strength of fire-ignited RC slabs are investigated by experimental tests and numerical simulations. The fire tests of RC slabs were carried out in a furnace using the ISO 834 standard fire. The load capacity of the cooled RC slabs that were not loaded during the fire tests was evaluated by additional 3 point bending tests. The influence of the proportion of PP (polypropylene) fibers in the RC slabs on the structural behavior of the RC slabs after the fire loading was investigated. The results of the fire tests showed that the maximum temperature of concrete with PP fiber was lower than that of concrete without PP fiber. As the concrete was heated, the ultimate compressive strength decreased and the ultimate strain increased. The load-deflection relations of RC slabs after fire loading were compared by using existing stress-strain-temperature models. The comparison between the numerical analysis and the experimental tests showed that some numerical analyses were reliable and therefore, can be applied to evaluate the ultimate load of RC slabs after fire loading. The ultimate load capacity after cooling down the RC slabs without PP fiber showed a considerable reduction from that of the RC slabs with PP fiber.

Fire-induced damage on Shield TBM concrete segment (터널 화재로 인한 콘크리트 세그먼트의 손상특성 규명)

  • Choi, Soon-Wook;Chang, Soo-Ho;Lee, Gyu-Phil;Bae, Gyu-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.423-430
    • /
    • 2005
  • Fire accidents in underground space may bring much loss of lives as well as properties and result in catastrophic disasters. This study aimed to manufacture the high-temperature furnace capable of simulating fire scenarios (RABT and RWS) and carry out the preliminary fire tests to evaluate fire-induced damage in underground structures. Specimens used in the fire tests were the concrete segments generally used in shield TBM tunnels. The simulated fire scenario was set to the RABT curve that is the most representative fire scenario in underground space. From the fire tests, the spalling was estimated to reach approximately 20cm from the surface exposed to fire. In addition, from the observation of core specimens obtained after fire tests, the deteriorated zone of unspalled specimens amounted to approximately 10cm from the surface of spalling.

  • PDF

Applying to simulation analysis for predicting the combustion performance of Large scale fire tests (실대화재시험의 연소성능 예측을 위한 시뮬레이션 적용)

  • Kim, Woon-Hyung;Park, Kye-Won;Jeong, Jae-Gun;Im, Hong-Soon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.86-92
    • /
    • 2008
  • On this study, modeling works using Cone tools simulation method were made for the prediction of real fire test results such as small to large scale fire tests including ISO 5660-1, EN 13823 and ISO 13784-1. For those simulation prediction, three real fire tests were performed in advance. In addition, Real data from ISO 5660-1 test were applied to this simulation modeling. Finally, the comparative analysis between Real fire tests and Simulation results were made out. Also, the Classifying evaluation by EURO Class using EN 13501-1 were taken off.

  • PDF

An Analysis on Confidence Level of Domestic Precision Guided Missile(PGM) based on Live-fire Test Results (국내 정밀유도무기 사격시험 결과 기반 신뢰수준 분석)

  • Seo, Bo-Gil;Yoon, Young Ho;Kim, Bo Ram
    • Journal of Korean Society for Quality Management
    • /
    • v.48 no.1
    • /
    • pp.215-225
    • /
    • 2020
  • Purpose: The purpose of this study was to show current states of domestic Precision Guided Missile(PGM) by analyzing Live-fire test results using general methods to get the Confidence Levels. Methods: Live-fire test results were used to get Confidence Levels of PGM. The Confidence Levels were derived by two general methods. The first method was Binomial distribution and second was convergence of Hypergeometric distribution and Bayes' rule. Results: The results of this study are as follows; The more Live-fire tests of PGM are performed, the higher Confidence Level of PGM will be estimated. And the number of Live-fire tests are related to a unit price of PGM. This results means that the increase of live-fire test, which is useful data for preparation and evaluation of Development Tests / Operation Tests for PGMs, is only way to enhance the Confidence Levels of each PGMs. Conclusion: This study shows the relationship between the Live-fire tests and Confidence Levels of PGMs and it will be used on Live-fire Test & Evaluation of PGMs for reference.

The Evaluation of Fire Endurance of Glazing Systems with Automatic Sprinklers (자동 스프링클러로 보호된 창의 내화 성능 평가에 관한 연구)

  • Lee, Chang-Seop;Chang, Sok-Hwa;Kim, Hong;Jung, Ki-Chang
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1998.11a
    • /
    • pp.73-76
    • /
    • 1998
  • To use glazing systems protected by automatic sprinklers as fire barriers in building compartmentation, fire endurance tests of these systems have been performed by several research workers. Most of the tests concerned the types of glasses and sprinklers, sprinkler water flow rate, and sprinkler activation time. Horizontal side wall sprinklers and window glazing systems with a vertical center mullion were mainly applied in the tests. In the study, full-scale fire endurance tests were carried out to verify the ability of large glazing systems divided by a horizontal mullion and protected by pendent vertical sprinklers. The result shows that the protrusive length of the horizontal mullion, which is perpendicular to the glass surface, is the main parameter that determines the fire resistance rating of the systems. The mullion obstructs the water flow in the glass.

  • PDF

Tests of Fire and Flame Retardant Performance for Membrane Materials (막재료의 난연 및 방염성능 실험에 대한 연구)

  • Kim, Gee-Cheol;Choi, Kwang-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.2
    • /
    • pp.55-60
    • /
    • 2016
  • The Membrane structure has a number of problems in the application of a fireproof code based on general buildings codes. Thus, the fireproof code of membrane structure is necessary to activate the construction of the membrane structure. Because it requires a systematic classification of fire retardant and flame proof performance of membrane material. Fire retardant and flame proof tests are conducted on membrane materials mostly used in current construction to propose the fire and flame retardant performance criteria of membrane materials. Fire and flame retardant tests results, PTFE membrane material with the glass fiber fabric have a limit-combustible performance. PVDF membrane material with the polyester fabric does not ensure the fire retardant performance, but this membrane material has the flame retardant performance of a thick fabric. Also, ETFE does not ensure the fire retardant performance, but this membrane material has the flame retardant of a thin fabric.

Evaluation of the Fire Resistance Performance of Interior Anchor Type CFT Columns through Loaded Heating Test

  • Kim, Sunhee;Yom, Kyongsoo;Choi, Sungmo
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.39-48
    • /
    • 2013
  • The fire resistance performance of generic CFT columns has been verified through various tests and analyses and the columns are widely used for fire resistance designs abroad. In this study, 3 groups of specimens (Non-fire protection, reinforcement with steel fiber and fire resistance paint) are suggested in order to evaluate the fire resistance performance of interior anchor type concrete-filled steel tubular columns having efficient cross-sections through loaded heating tests. Axial deformation-time relationship and in-plane temperatures are compared to evaluate the fire resistance performance of the specimens associated with variables. Suggested from the fact that the interior anchors exposed to fire exert influence on fire resistance performance due to thermal expansion, the reinforcements using steel fiber and fire resistance paint are verified to mitigate contraction and improve fire resistance performance. The result obtained from the tests of interior anchor type concrete-filled tubular columns is expected to be used for effective fire resistance design in association with previously conducted studies.

Structural performance of unprotected concrete-filled steel hollow sections in fire: A review and meta-analysis of available test data

  • Rush, David;Bisby, Luke;Jowsey, Allan;Melandinos, Athan;Lane, Barbara
    • Steel and Composite Structures
    • /
    • v.12 no.4
    • /
    • pp.325-350
    • /
    • 2012
  • Concrete filled steel hollow structural sections (CFSs) are an efficient, sustainable, and attractive option for both ambient temperature and fire resistance design of columns in multi-storey buildings and are becoming increasingly common in modern construction practice around the world. Whilst the design of these sections at ambient temperatures is reasonably well understood, and models to predict the strength and failure modes of these elements at ambient temperatures correlate well with observations from tests, this appears not to be true in the case of fire resistant design. This paper reviews available data from furnace tests on CFS columns and assesses the statistical confidence in available fire resistance design models/approaches used in North America and Europe. This is done using a meta-analysis comparing the available experimental data from large-scale standard fire tests performed around the world against fire resistance predictions from design codes. It is shown that available design approaches carry a very large uncertainty of prediction, suggesting that they fail to properly account for fundamental aspects of the underlying thermal response and/or structural mechanics during fire. Current North American fire resistance design approaches for CFS columns are shown to be considerably less conservative, on average, than those used in Europe.

HOT-SMOKE TESTS IN TWO UNDERGROUND RAILWAY STATIONS WITH MOVING TRAINS

  • Allan, Hugh
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.472-476
    • /
    • 1997
  • Hot-smoke testing in Australia has progressed to the stage where there is an Australian Standard for these tests. The purpose of such tests is twofold: firstly they can validate computer modeling predictions for smoke movement, and secondly they can demonstrate that the smoke control systems and associated fire safety systems function satisfactorily. Hot-smoke tests were carried out in March 1997 at two of Sydney's underground railway stations, namely St James and Museum. The purpose of the tests was to demonstrate that the smoke control systems performed their functions as intended. Tests were carried out in the concourses and on the platforms, and trains ran during the tests so that the effect of moving trains on smoke movement could be observed. A total of five tests were carried out and video recordings were taken of each. This is the first time that hot-smoke tests have been carried out in an underground station with trains running. The paper discusses some of the interesting observations and the problems identified by the tests.

  • PDF