• Title/Summary/Keyword: fire test

Search Result 1,887, Processing Time 0.035 seconds

A Report on Test Results of Fusible-Link Type Heat Responsive Links (Fusible Link Type 감열체 성능시험보고)

  • Gwon, O-Seung
    • Fire Protection Technology
    • /
    • s.10
    • /
    • pp.5-8
    • /
    • 1991
  • This report is explained about test results of heat responsive links for fire protection service, such as fire dampers and fire doors, automatic fire suppression systems and so forth. The testing program was progressed divided by two testing items, external appearance test and performance test. The object of this report is present the problem which appear from the analysis of test results.

  • PDF

A Study on the Analysis of Fire Hazards for Communication Cable (통신케이블의 화재위험성 분석에 관한 연구)

  • Hong, Sung-Ho;Park, Chan-Ho;Park, Sang-Tae;Yu, Song-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.192-194
    • /
    • 2009
  • This study presents on the analysis fire hazards of communication cable. In order to analyze fire hazards fire retardant tests and con-calorimeter test is conducted. The fire retardant tests are IEC 60332-1 and UL 94 test. The results show that IEC 60332-1 test and It 9t test are not effective to estimate fire hazard. And various parameter is obtained by con-calorimeter test. It is necessary to analysis effectively fire hazards of cable for new fire retardant test.

  • PDF

Study on Fire safety test method for the bed mattress (침대 매트리스 화재안전 평가에 대한 국내외 적용 현황)

  • Park, Kye-Won;Jeong, Jae-Gun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.325-328
    • /
    • 2012
  • This paper intends to introduce foreign/ domestic situation on fire safety assessment of bed mattress. America continent countries and ISO recently adapt real scale test method, other coutries including Korea have been using small scale test method such as IMO FTP code's bed component fire test.

  • PDF

An Experimental Study on the Warehouse Mock-up Fire Test (창고 모델 실물화재 특성에 대한 실험적 연구)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.47-54
    • /
    • 2010
  • This study is analyze the damage of warehouse fire accident be made through the fire characteristic database of combustibles and real scale fire test of warehouse mock-up. Combustibles fire tests are carried out for database using RCT (Room Corner Tester) to predict fire growth the goods. A mockup ($3m{\times}3m{\times}2.4m$) of clothes warehouse was built and real scale fire test by LSC (Large Scale Calorimeter) base on the fire characteristic DB. The mock-up of clothes warehouse is made of two type sandwich panels (Glass wool, EPS foam sandwich panel). As a mock-up test result, test 1 (Glass wool sandwich panel) and test 2 (EPS foam sandwich panel) indicating fire growth such as 5 MW, 11 MW of maximum HRR (Heat Release Rate).

Description on assessment system of bed mattress's fire safety in real scale (침대 매트리스 실규모 화재안전 평가시스템 기술)

  • Park, Kye-Won;Jeong, Jae-Gun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.329-332
    • /
    • 2012
  • This study focuses on the establishment of bed mattress fire test in real scale where it explains the burner heat supply, test procedure and test report in detail. Especially burner system is dealt in importance for bed mattress test in real scale due to simulating in bedding component by burner heat out-put.

  • PDF

A Study on the Development, Performance and Reliability Certification for Fire Detection System in Outdoor Area (옥외형 화재경보시스템의 개발과 성능시험에 관한 연구)

  • Baek, Dong-Hyun;Ghil, Min-Sik
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.15-18
    • /
    • 2013
  • This paper is concerned with the Performance and Reliability Certification for fire detection system in outdoor area such small and middle sized cultural assets, natural monument and outdoor facilities. Especially, if a fire were to occur in vulnerable area, it is difficulty to detect a fire. therefore we propose a high efficiency and low cost unmanned fire detection system in capable of an early detection regardless spontaneously fire or firebug. for Adoption of Intelligent Fire Detection System with movable and unmanned function breaking from the existing Conventional Fire Detection System, this Range of R&D includes the Performance test, Function test, Field test, Flame Detection test and EMI/EMS Compliance test. the Result data of Performance test, Function test and Field test is generally good during 3 months. also we checked that thermal variation test and EMI/EMS compliance test are good result data within allowable range. As a result of general test, we verified improvement results that the measure distance of fire detection extend 75 m, the Power of waiting time increase 4 hours, the Power of operation time increase 3 days and the context awareness with video as well as sensors.

An Experimental Study on Piping Feasibility of PE Compound Pipe for Fire Protection Service (PE 이종강관의 소방용 배관 적용성에 관한 실험적 연구)

  • Park, Jeong-Hwa;Oh, Cheon-Young;Kwark, Ji-Heon;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.55-61
    • /
    • 2016
  • In this study, to determine whether it is possible to apply Polyethylene (PE) compound pipe, which was developed to solve the problem caused by the corrosion of the fire protection piping currently in usein water based fire extinguishing systems, we performed an actual mockup fire test. Since no test standard was available related to the developed compound pipe, we compared and analyzed domestic and international technical materials and test standards and selected suitable fire test standards to evaluate the performance of the PE compound pipe. we applied two fire test standards to the PE compound pipe, viz. those for CPVC and metallic pipes, and conducted a total of 6 experiments to evaluate its performance. According to the results of the first and second fire tests based on the test standard for the CPVC pipe, neither the fitting nor the piping was damaged or deformed and no leakage was observed in the pressure test, which was performed for 5 minutes. For the fire test based on the metallic pipe test standard, a total of 4 experiments were conducted. The first two experiments were conducted to simulate the wet piping system. In the results of this fire test, neither leakage nor rupture was observed from the PE compound pipe and no damage was caused, such as the secession of the PE material. However, in the next two experiments, which simulated the dry system, the PE compound pipe suffered damage and rupture, including deformation before the fire fighting water was discharged. Therefore, we found that the piping performance of the PE compound pipe did not undergo any deterioration, including fusion, deformation, or damage, in the wet piping system simulated fire test.

A Study on the Flame Resistance Performance and Smoking Characteristics of the Flame-Resistant Paint (방염도료의 방염성능 및 발연특성에 관한 연구)

  • Kim, Hwang-Jin;Lee, Sung-Eun;Oh, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.78-83
    • /
    • 2009
  • 17 kinds of fire resistant paint which are currently used were painted on the MDF, to find flame resistance performance and smoking characteristics according to principal ingredient and characteristics of fire resistant paint. 45 degree combustion test and smoke density test were conducted to investigate the flame resistance performance and smoking characteristics. According to the 45 degree combustion test, acrylic resin type fire resistant paint showed the most excellent fire resistance performance. And the water soluble fire resistant paint showed better fire resistance performance compare to the solvent soluble paints. Also gloss paint showed better fire resistance performance than the flat paint. Based on the smoke density test, the smoke generation of fire resistant treated specimen of acrylic resin type was least. And the water soluble fire resistant paint generate little smoke than solvent soluble fire resistant paint.