• 제목/요약/키워드: fire risk assessment

검색결과 350건 처리시간 0.026초

Characteristics of a Corona between a Wiring Clamp(Dead End Clamp) and a Porcelain Insulator Used in a 154[kV] Power Receptacle

  • Han, Un-Ki;Kim, Jong-Min;Bang, Sun-Bae;Kim, Han-Sang;Choi, Hyeong-Jun
    • 조명전기설비학회논문지
    • /
    • 제21권9호
    • /
    • pp.57-63
    • /
    • 2007
  • The occurrence of a corona is that electrical discharge due to the heterogeneity that occurs when an electrical field is concentrated in an electrode due to a cusp formed on said electrode. Wire treatment at the end of a 154[kV] dead end clamp for end users accelerates the occurrence of corona, which in turn leads to power loss and noise. In this study, the characteristics of the corona which occurs between porcelain insulators and support clamps of overhead lines used in 154[kV] power receiving facilities for end users were investigated. The corona, which cannot be identified by one common method, was measured utilizing a UV image camera. A risk assessment for fire damage and its status was suggested. The stress distribution of the electrical field by length of bare wire was suggested by means of the finite element method(FEMLAB). As a result, it was found to affect a porcelain insulators. These results can be utilized for the enhancement of clamp installation and safety in power facilities.

BLEVE로 인한 과압 예측에 관한 연구 (A Study on the Overpressure Estimation of BLEVE)

  • 김인태;김인원;송희열
    • 한국가스학회지
    • /
    • 제4권1호
    • /
    • pp.69-76
    • /
    • 2000
  • BLEVE로 인한 위험을 평가하기 위한 프로그램, BLEVE ESTIMATOR를 이용하여 온도에 따른 폭발량과 Flashing mass를 계산하였고, 부천 가스충전소의 사고를 모델로 피해를 예측하였으며, 상용프로그램인 Dupont의 SAFER 프로그램과 비교하였다. 폭발량과 Flashing mass는 폭발온도의 증가에 따라 지수함수로 증가하였으며, Propane이 n-Butane보다 상대적으로 높게 나타났다. 용기의 온도, 압력, 충전비가 높을수록 Overpressure가 높게 나타났다.

  • PDF

계층분석과정(AHP)을 이용한 전기안전기술 우선순위 및 추진방향 분석연구 (The Analysis of the Priority and Progress Direction of Electrical Safety Technology using Analytic Hierarchy Process)

  • 김한상;이건호;김동우;전정채;이기연;김영석;정진수
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1784-1791
    • /
    • 2013
  • Electrical safety technique is a disaster prevention technology to protect the life and property of the people and it has high correlation with all electricity industry. According to the latest statistics, loss of human life and property damage due to electrical fire have increased from 2011. Therefore, technological development for guarantee safety of electrical facilities for customer will become more important. In this paper, we drew priority and weigh for the electrical safety technology using analytic hierarchy process and present progress direction of each technology through Risk-Return assessment. We expect development of the research and development policies of government about electrical safety technology in a higher state and think that policymakers and experts will be more interested in these fields based on this paper.

Fireball로 인한 Thermal flux 예측에 관한 연구 (A Study on the Thermal Flux Estimation of Fireball)

  • 김인태;김인원;송희열
    • 한국가스학회지
    • /
    • 제4권3호
    • /
    • pp.46-52
    • /
    • 2000
  • Fireball로 인한 위험성 및 피해를 평가하기 위한 프로그램, FIRESTOR를 개발하여 Fireball로 인한 Thermal flux를 예측하였고, FIRESTOR 프로그램을 부천가스 충전소 사고를 모델로 하여, BLEVE ESTIMATOR와 상용프로그램인 Dupont 사의 SAFER와 비교 분석 하였 다. 용기압력이 일정시 Propane과 Butane의 경우 Thermal flux는 거리변화에 따라 지수함 수로 감소하였다. 거리변화에 따른 Thermal flux변화를 BLEVE ESTIMATOR, SAFER, FIRESTOR로 상호 비교한 결과 본 연구에서 연구개발한 FIRESTOR 프로그램은 SAFER 와 ESTIMATOR의 중간값으로 Dupont사의 상용프로그램인 SAFER에 근접하는 경향을 보이고 있어 우수한 프로그램으로 판단된다.

  • PDF

EPS공정에서 발생하는 n-Pentane의 화재폭발에 대한 위험성평가 및 위험성 완화 대책에 관한 연구 (A Study on the Risk Assessment and Mitigation Plan about Fire Explosion of n-Pentane in EPS Process)

  • 서민수;김기석;김보민;강동천;강길재;천영우
    • 한국위험물학회지
    • /
    • 제6권2호
    • /
    • pp.39-46
    • /
    • 2018
  • 최근 전자제품 생산업체에서 EPS를 직접생산하게 되면서 EPS 공정이 증가하고 있다. EPS에는 펜탄이 포함되어 있으며, 펜탄은 하이브리드 혼합물로 구분할 수 있어 높은 화재폭발의 위험성을 가지고 있다. 각 공정별 펜탄의 누출률은 발포기, 사일로실, 저장실 순이나 발포기의 경우 일반적으로 밀폐되어 있으므로 사일로 실이 가장 화재폭발 위험성이 높다고 판단하였다. 사일로실의 누출률 중 70%는 사일로 상단을 통해 누출되며, 사일로 상단을 통해 누출되는 펜탄의 거동을 분석하여 사일로실 위험성 완화대책을 수립하였다. 1. 폭발위험구역 2종으로 관리, 2. 사일로상단 50cm이내 환기설비 설치 또는 Push-Pull 구조의 환기설비설치, 3. 사일로 하단 1.4m이내에 가스감지기 설치, 4. 60%이상의 습도유지

전문건설업 안전문화 평가에 관한 연구 (A Study on the Evaluation of Safety Culture in Specialty Contractor)

  • 신상연;백신원;정성룡
    • 한국안전학회지
    • /
    • 제36권2호
    • /
    • pp.18-25
    • /
    • 2021
  • Specialty contractor facilities, which involve a combination of welding and commissioning, face a high risk of serious accidents such as fire, explosion, and suffocation associated with welding work, nitrogen, and argon use. In such facilities, the organizational safety culture has considerable impact on the frequency of accidents. In this study, a safety culture evaluation was conducted on specialty contractors. NOSACQ-50, a standardized survey method on safety culture, was selected as an assessment tool to evaluate the safety culture in specialized construction companies that could not afford to invest heavily in safety. The self-administered questionnaire survey was conducted with 201 workers of four construction companies and the results were analyzed. It was found that in companies with low safety culture, the occurrence of irrationality was 66.0%, while in companies with high safety culture, the occurrence of irrationality was 42.6%. Thus, the difference in the occurrence of irrationality by safety culture was statistically significant. The difference in safety culture level according to the experience of occurrence of irrationality was also significant. It was also found that the higher the belief in safety management authorization, safety responsibilities of managers, worker safety priorities, and safety system effects, the lower the probability of irrationality.

깊이 인자를 고려한 매설배관의 사고피해영향 비교 분석에 관한 연구 (A Study for Comparison of Consequence Analysis for Buried Pipeline Considering the Depth Factor)

  • 한승훈;설지우;류병태;태찬호;고재욱
    • 한국가스학회지
    • /
    • 제20권5호
    • /
    • pp.9-16
    • /
    • 2016
  • 매설배관은 내부 또는 외부의 결함으로 인하여 leak나 rupture가 발생 할 수 있으며, 가스가 누출 시 큰 사고가 발생할 수 있기 때문에 정량적 위험성평가를 통한 분석이 필요하다. 하지만 현재 매설배관에 대한 위험성 평가시 매설을 고려하지 않거나, 매설 깊이를 고려하지 않고 무조건 배관압력의 1/10으로 가정하는 OGP기준을 사용하고 있는 실정이다. 이에 본 연구에서는 여러 기관의 매설배관 ETA분석자료를 통하여 발생가능 사고 중 Jet fire의 사고피해영향을 분석하였으며, Jet fire의 복사열 계산에 있어서 배관의 매설깊이 인자를 고려한 매설모델을 수립하였다. 사례연구는 New Jersey의 Edison지역에서 발생한 사고를 이용하여 본 모델과 OGP모델을 비교 분석하였다. 연구결과 화염원으로부터 10m거리를 기준으로 매설모델의 복사열 값이 OGP모델에 비해 실제 사례와 비슷한 값을 얻을 수 있었다.

에너지 시설물의 위험성 평가에 따른 비상대응 시스템 구축 (Development of Emergency Response System by Risk Assessment Methodology in Energy Facility)

  • 이헌석;강승균;정인희;김범수;유진환;박철환;김대흠;고재욱
    • 한국가스학회지
    • /
    • 제12권2호
    • /
    • pp.118-123
    • /
    • 2008
  • 도시에는 에너지 시설물로서 고압가스 저장시설 및 고압가스 배관 등 위험물을 취급하는 시설이 산재해 있고, 이런 시설들의 효율적인 위험성 분석 및 관리시스템의 부재로 사고 가능성이 상존하며 선진국에 비해 상대적으로 높은 사고율을 보이고 있다. 에너지 시설물에서 발생하는 사고는 시설 자체의 막대한 피해 뿐만 아니라 시설 주변 지역에 미치는 영향이 매우 크므로, 본 연구에서는 사고영향 분석을 통한 비상대응 시스템을 적용하여 사고피해 정도에 대한 정보를 이용한 체계적인 대응체제를 구축하였다.

  • PDF

바닥내장재의 연소특성 분석에 관한 연구 (A Study on Analysis of Characteristics Combustion of Floor Covering Materials)

  • 박영주;이해평;김현주
    • 한국방재학회 논문집
    • /
    • 제10권3호
    • /
    • pp.77-83
    • /
    • 2010
  • 본 연구에서는 건축물 내장재 가운데 바닥재의 화재특성을 평가하기 위하여 목재, 모노륨, 장판지, 니스코팅 된 장판지 등 4종의 바닥재를 대상으로 콘칼로리미터, 발화온도시험기, 열중량분석기, 한계산소지수시험기 등을 이용하여 착화성, 발열특성, 난연성과 같은 연소특성을 분석하였다. 모노륨은 발화온도가 $325^{\circ}C$로 가장 낮았으며, 장판지와 니스코팅 된 장판지는 비교적 빠른 시간인 7초 이전에 착화가 시작되었다. 총열방출량은 목재가 $100MJ/m^2$로 가장 높게 나타났지만 최대열방출율은 니스코팅된 장판지가 가장 높은 것으로 나타났다. 열중량분석 결과, 모든 바닥재들이 $300{\sim}400^{\circ}C$ 온도구간에서 급격한 중량감소를 보였으며, 한계산소지수는 장판지와 니스코팅 된 장판지가 20~21% 정도이고 목재는 34%로 나타났다. 본 연구결과를 살펴보면, 모노륨, 장판지, 니스코팅 된 장판지는 착화가 빠르고 연소가 용이한 반면, 발열량은 낮은 것을 알 수 있었으며, 목재는 비교적 착화위험성이 낮고 난연성은 좋지만 발열량이 높은 것으로 나타났다.

지역사회 재난회복력 구성요소와 재난관리정책 결정요인 분석 (A Comparative Study on the Importance of the Components of the Community Disaster Resilience on Disaster Response)

  • 김진근;박찬석
    • 한국재난정보학회 논문집
    • /
    • 제15권3호
    • /
    • pp.339-346
    • /
    • 2019
  • 연구목적: 사실 재난대응을 잘하기 위해서는 발생한 재난에 대한 철저한 분석과 평가로 자연스럽게 완화 및 대비가 이루어져야 했어야 함에도 불구하고 "대응 ${\rightarrow}$ 복구 ${\rightarrow}$ 완화 ${\rightarrow}$ 대비${\rightarrow}$ ${\ldots}$"가 선(善)순환적으로 작동되지 않아 분절적 재난관리가 반복되었다. 연구방법: 여러 다각적인 연구방법 및 분석을 통해 결국 사회재난 중심 재난관리체제인 우리나라에서 지역사회의 재난회복력을 높이기 위해서는 연구결과: (1) "시민 안전교육 및 훈련" (2) "시민대상 실시간 재난정보제공 및 공유" (3) "재난정보 및 경보시스템 네트워크(연결망) 구축" (4) "재난분석과 평가(위험성 및 취약성 평가)" (5) "재난완화계획"(6) "정부 간(間) 협조체계 구축" 등 주요 구성요소가 재난관리정책에 구체적으로 반영되어 실현되어야 함을 검증하였다. 결론: 이제는 더 이상 악(惡)순환적 또는 단절적 재난관리가 아닌 선(善)순환적 연결된 재난관리가 되어야 한다. 재난관리를 더 잘하기 위해서는 완화 및 대비 영역에서 재난대응에 영향을 주는 재난회복력 주요 구성요소가 재난관리의 선(善)순환적인 연결고리에 작동할 수 있도록 재난관리정책에 우선적으로 반영되어야 할 것이다.