• Title/Summary/Keyword: fire retardant chemicals

Search Result 33, Processing Time 0.025 seconds

Effects of the Treated Chemicals on the Flexual and Physical Properties of Fire Retardant Treated Particleboards (내화처리(耐火處理) 파티클 보오드의 휨강도(强度)와 물리적(物理的) 성질(性質)에 미치는 약제(藥劑)의 영향(影響))

  • Lee, Phil-Woo;Kwon, Jin-Heon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.39-48
    • /
    • 1983
  • This research was performed to investigate the manufacturing possibility of the particleboard treated with commercial fire retardant chemicals. Laboratory test boards at this investigation were made from particles treated by soaking into 5, 10, 15, and 20 percent concentration solutions of ammonium sulfate and Minalith before resin was applied. According to the results, MOR (modulus of repture) and MOE (modulus of elasticity) in flexure exceeded type 100 (100 kgf/$cm^2$, $1.5{\times}10^4\;kgf/cm^2$) of the Korean Industrial Standard (KS F 3104). Except for 15 and 20 percent chemicals concentrations of Minalith, every internal bond stress values met type 100 (1.5 kgf/$cm^2$) of KS F 3104. However thickness swelling values of fire retardant treated particleboards were not reached in the Standard (12%).

  • PDF

Combustion Characteristics of Fire Retardants Treated Domestic Wood (난연처리 국산 침엽수재의 연소특성 분석)

  • Seo, Hyun Jeong;Hwang, Wuk;Lee, Min Chul
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.2
    • /
    • pp.9-18
    • /
    • 2017
  • In this study, we measured that fire characteristics of four wood species using indoor finish materials. Wooden specimens were treated with fire retardant chemicals such as diammonium phosphate and potassium carbonate. The wooden specimens are Larix kaempferi, Pinus koraiensis, Cryptomeria japonica, and Chamaecyparis obtusa, which are used for indoor finish. The heat release rate (HRR) values of fire retardant treated woods were confirmed lower than that of untreated woods. For specific details, the HRR values of vacuum impregnated specimens for Pinus koraiensis and Cryptomeria japonica were measured lower than coatings. However, those of Larix kaempferi and Chamaecyparis obtusa showed the opposite effect to it. Total heat release rate values of all wooden specimens, vacuum impregnated were lower than coated specimens.

Studies on the Fire Retardant Treatment of Wet Forming Mat for Hardboard (경질섬유판(硬質纖維板)의 습식(濕式)매트 내화처리(耐火處理)에 관(關)한 연구(硏究))

  • Shin, Dong-So;Lee, Hwa-Hyoung;Shim, Chong-Supp
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.180-188
    • /
    • 1982
  • This study was carried out to make hardboard fire retardants and to examine the properties of the hard-board treated with them. The fire retardant treatment was achieved by surface impregnation of water soluble retardant chemicals into the forming mat with 55 percent of moisture content. followed by the hot pressing process. Ammonium monophosphate, ammonium diphosphate, sodium borate, and boric acid were used as the fire retardants. Fire retardant test was carried out by using the differential thermal analysis thermogram. The results are summarized as follows: 1. Fire retardant-treated hardboard showed higher values of the specific gravity. water absoption, and flexural strength than those of untreated hardboard. Especially, the treatment of ammonium monophosphate gave the best results in the flexural strength, and a 10 gr/$ft^2$ loading of the fire retardant compound of ammonium monophoshate, ammonium diphosphate, and sodium borate drew the best flexural strength value among the three different experimental loadings of 10, 20 and 30 gr/$ft^2$. 2. There were no definite differences in moisture content between the fire retardant-treated hardboard and the untreated hardboard. 3. The fire retardant compound of ammonium monophosphate, ammonium diphosphate, and sodium borate resulted in the best fire retardancy, and its fire retardancy was increased in proportion to the increase of loading.

  • PDF

Decay Resistance and Anti-mold Efficacy of Wood Treated with Fire Retardants (난연처리 목재의 방미 및 방부성능)

  • Son, Dong Won;Kang, Mee Ran;Lee, Dong-Heub;Park, Sang-Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.6
    • /
    • pp.559-565
    • /
    • 2013
  • This study evaluated the ability of white and brown rot fungi to decompose fire retardant-treated wood by measuring mass loss. Anti efficacy of FRT against sapstain and mold fungi was evaluated. Wood was treated with liquid sodium silicate and boric acid, ammonium borate, di-ammonium phosphate. Retardant treated wood was then subjected to fungal decay resistance tests performed according to KS standard method using a brown-rot fungus, Fomitopsis palustris and white rot fungus Trametes versicolor. Aspergillus niger, Penicillium funiculosum, Rhizopus nigricans, Aureobasidium pullulans, Tricoderma virede fungi were used anti-sapstain and mold test. Boron and phosphorus chemicals used in this study increased the resistance of fire retardant treated wood against both fungal attack. Anti mold and sapstain efficacy of the fire retardant treated wood was excellent but there were difference depend on mold. After the liquid sodium silicate treatment, the second chemical treatment process could lead chemical fixation into wood, which effects decay resistance.

A Study on the Fire Resistance of Korean Cellulose Insulation (국내 섬유질 단열재의 내화성능에 관한 연구)

  • Kwon, Young-Cheol;Hwang, Jung-Ha;Yu, Hyung-Kyu
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.4
    • /
    • pp.10-16
    • /
    • 2008
  • The fire resistance of thermal insulation and interior finishing materials is recently much emphasized after the fire accident at the Icheon Cold Store in January 2008. Three kinds of thermal insulation are used in buildings. They are Organic, Non-organic and cellulosic insulation. Organic insulation such as polystyrene foam board and urethane foam has high thermal resistance but it has no fire resistance. While non-organic insulation such as rockwool and glassfiber has high fire resistance, it has lower thermal resistance than organic insulation. Cellulose insulation is primarily manufactured from recycled newsprint or cardboard using shredders and fiberizers. Despite of its environmental friendliness and high thermal resistivity, its domestic use has not much increased because of the prejudice that paper can easily burn. However, the cellulose insulation as a product is about 80 wt.% cellulosic fiber and 20 wt.% chemicals, most of which are fire retardants such as boric acid and ammonium sulfate. It is required to secure its fire safety for more consumption as a building insulation in Korea. Therefore, this study investigates the fire resistance of Korean cellulose insulation according to the rate of fire retardant and finally presents the optimum rate of fire retardant in cellulose as building insulation. The fire safety test was conducted according to the ASTM C 1485-00. The test results indicate that above 18 wt% of fire retardant is necessary to secure the fire safety of cellulose insulation.

Studies on the Residual Bending Strength of burned Douglas-fir and Western Hemlock soaked with Fire Retardant Chemicals (내화처리(耐火處理) 미송(美松) 및 미삼재(美杉材)의 연소후(燃燒後) 잔유(殘留)휨강도(强度)에 관한 연구(硏究))

  • Lee, Phil-Woo;Park, Heon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.15-24
    • /
    • 1984
  • The $3{\times}3{\times}30\;cm^3$ sized specimens of Douglas-fir(Pseudotsuga menziesii) and western hemlock(Tsuga heterophylla) in this study were soaked in four fire-retardant solutions of ammonium sulfate, monoammonium phosphate, diammonium phosphate, and aluminium chloride for 1, 24, 72, 168, and 336 hours. Subsequently they were air-dried and burned at high temperature of ca. $1,800^{\circ}C$ and for short time of 5 minutes. This study estimated the relationship between the adsorbed chemicals and the residual weight ratio or residual bending strength of these partly burned lumbers. The results were as follows; 1) In average amount of chemical adsorption, diammonium phosphate showed the largest and aluminium chloride the smallest regardless of species but monoammonium phosphate was larger in Douglas-fir than that of western hemlock. 2) The amount of chemical adsorption was larger in western hemlock than Douglas-fir on the whole. 3) The amount of chemical adsorption was increased with the increase of soaking time but the rate of increase began to decrease at 200hrs. 4) Residual weight ratios showed no difference between species but showed differences among the chemicals treated i.e. monoammonium phosphate, diammonium phosphate, ammonium sulfate and aluminium chloride in turn from the largest to the smallest. 5) MOR values showed linear increase with the increase of residual weight ratios but showed no difference in species and chemicals respectively. 6) In the relationship between amount of chemical adsorption and MOR, only diammonium phosphate showed the curve of secondary degree with significance in Douglas-fir. 7) The MOE value of burned Douglas-fir lumber increased and showed significance of 99% as the adsorbed chemical amount increased, but among the chemicals only monoammonium phosphate showed significance. The MOE value of burned western hemlock lumber didn't show significance. 8) In only Douglas-fir, the correlation between adsorbed chemical amount and work to proportional limit showed significance in only monoammonium phosphate. And in both Douglas-fir and western hemlock, the correlation between adsorbed chemicals and work to maximum load showed significance in monoammonium phosphate.

  • PDF

A Comparative Study on the Mechanical Properties of Plywood treated with Several Fire-Retardant Chemicals(II) - Effect of Platen Temperature in Press Drying on the Static Bending Strength of Treated Plywood - (수종(樹種) 내화약제(耐火藥劑)로 처리(處理)된 합판(處理)의 기술적(技術的) 성질(性質)에 관(關)한 비교연구(比較硏究)(II) - 열판건조시(熱板乾燥時) 열판온도(熱板溫度)가 처리합판(處理合板)의 휨강도(强度)에 미치는 영향(影響) -)

  • Chung, Woo-Yang;Kim, Jong-Man;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.12-18
    • /
    • 1984
  • Soaking treated in 20% aqueous solutions of $(NH_4)_2SO_4$, $NH_4H_2PO_4$, $(NH_4)_2HPO_4$, $Na_2B_4O_7-H_3BO_3$(60:40) and Minalith, the mixed salts for 9 hrs. the wet 3.5mm meranti (Parashorea spp.) plywoods were press-dried at 90, 120 and $150^{\circ}C$ and put to static bending test to examine the influence of redrying temperature on the strength of fire-retardant treated plywoods ill flexure. While water-soaking treatment (control) showed serious reduction in Stress at proportional limit, MOE, MOR, Work per unit volume at $150^{\circ}C$, all the fire-retardant treatments maintained bending strength even at $150^{\circ}C$ and showed rather increased values in case of some chemicals. In view of drying rate and maintenance of strength, the most pertinent platen temperature was $150^{\circ}C$ and Borax-Boric acid was the predominant fire-retardant in this study.

  • PDF

A Study on the Acid Digestion Bomb Pretreatment Method of Fire Retardant Chemicals (DBDPE-$Sb_2O_3$) for the Determination of Antimony (DBDPE-$Sb_2O_3$ 중 Sb를 분석하기 위한 가압 산분해 전처리 연구)

  • Choi, Jong-Keum;Park, Je-An;Park, Kyung-Su;Kim, Sun-Tae;Kim, Young-Sang
    • Analytical Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.731-735
    • /
    • 2000
  • The acid digestion bomb pretreatment method for the determination of antimony in a commercial fire retardant material sample (DBDPE-$Sb_2O_3$) was studied. DBDPE-$Sb_2O_3$ sample was digested with $H_2SO_4:HCl$(1:2) mixture in digestion bomb at $220^{\circ}C$ for 2 hrs. and antimony was determined by atomic absorption spectrophotometry. Recovery of 99.6-99.8% and C.V. of 0.94-1.07% for Sb was obtained for spiked real samples. In the present method, the analytical results obtained for antimony were 40.3 and 36.3% (w/w), respectively.

  • PDF

Fire Retardancy and Mechanical Properties of Paper Sludge-Wood Particle Mixed Board (제지 슬러지-목재 파티클 혼합보드의 내화성과 기계적 성질)

  • Son, Jung-Il;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.54-65
    • /
    • 1994
  • This research carried out to investigate the effects of inorganic materials in paper sludge on the thermal degradation and of paper sludge addition on physical and mechanical properties of paper sludge-wood particle mixed boards in comparison with unmodified particleboards. Also these unmodified particleboards and paper sludge-wood particle mixed boards were soaked in aqueous solutions of fire-retardant chemicals(diammonium phosphate and zinc chloride), and their fire retardancy were tested by oxygen index method and ISO ignition test to determine the feasibility of paper sludge, industrial waste, as a recyclable resource in fabrication of fire-resisting panels for building material. Since the redrying of fire-retardant treated particleboards and paper sludge-wood particle mixed boards were made by press drying method, this process was a simple and effective method. On the other hand, flexural bending strength and internal bonding strength were also analysed to evaluate mechanical properties through standard method.

  • PDF

Effects of Treatment Methods of Fire-retardant and Layup of Treated Veneers on the Performances of Plywoods (내화약제(耐火藥劑)의 처리방법(處理方法) 및 처리단판(處理單板)의 조판형태(調板形態)가 합판(슴板)의 성능(性能)에 미치는 영향(影響))

  • Son, Jung-Il;Cho, Jae-Sung;Suh, Jin-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.39-50
    • /
    • 1999
  • This research was carried out to investigate the development of fire-retardancy treatment technology and performance evaluation of fire-retardant treated plywoods. Radiata pine, keruing, dillenia, calophyllum and terminalia veneers were treated by normal(conventional) pressure soak(NPS) and vacuum-pressure-soak(VPS) using 20% water solution of diammonium phosphate. Then, 4.8mm thick, 3ply plywoods were fabricated with combination of fire-retardant treated, untreated or water-immersion types and several composition types of radiata pine and keruing veneers, i,e. the uniform and the mixed types in species composition, and the homogenious and the alternate layer types in veneer treatment. In composed species, the retention and the treatment effects of fire-retardant chemicals III radiata pine was still greater than those of keruing. The effect of VPS treatment was larger than that of NPS treatment, however, adhesive bonding strength and bending strength of plywoods treated by these two methods were not necessarily lowered, compared to those of untreated plywood. And also, fire endurance performance of the urea melamine resin-bonded plywood was greater than that of the phenol resin-bonded plywood. In result, the appropriate combination in veneer species and layer as well as alternate fire-retardant treatments would be more efficiently available in service.

  • PDF