• Title/Summary/Keyword: fire prevention activities

Search Result 65, Processing Time 0.025 seconds

Analysis of Fire-Related State Compensation Cases (화재와 관련된 국가배상 사례의 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.109-117
    • /
    • 2019
  • When those who have caused a fire have no ability to compensate fire victims, the victims tend to charge fire agencies for state compensation to receive damage relief. This study analyzed two state compensation cases related to fires. The findings suggest that if there is a causal relationship between fire damage and mistakes committed by fire officials that are associated with fire prevention or special fire inspections, courts usually decide that fire agencies should compensate fire victims. Despite the introduction of a new article in the Framework Act on Fire-Fighting Services on December 26, 2017, titled "Exemption from Responsibility for Fire-Fighting Activities", exemptions are only available if inevitability of the activity has been proven. However, unlike rescue or first aid activity, inevitability is difficult to prove when it comes to fire inspection activity. Therefore, it is expected that state compensation suits related to fires will not decrease.

Effects of Recycling-Segregated Collection Activities on the Environmental Attitude of Elementary Students (초등학생의 환경태도 개선을 위한 재활용 분리수거 활동 프로그램 개발)

  • U, Sung-Hwan;Lee, Hae-Seung
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.3
    • /
    • pp.65-76
    • /
    • 2007
  • Values and attitude towards the environment begin to form in elementary school. Thus, environmental education is effective to promote children's sensibility on the environment, to increase their interest and concern on it, and to make them have friendly attitudes towards it. As a measure of such education, experiential learning activities are being emphasized, where children can see, feel and experience for themselves in a familiar environment surrounding them. Based on the results of this research, the following proposals can be made for environmental education necessary for elementary school children. i) the contents of environmental education should be selected and organized according to grades. Also, schedule should be secured to provide environmental education in certain time. ii) program should be developed to fit into local characteristics and academic level, providing connective and consistent environmental education. iii) activities for environmental education in elementary school can be effective only if connective guidances are provided among school, home and local community. iv) the recycling and separate collection activity program used in this research was limited to 3rd graders in small-size rural schools. Additional research may be necessary to see how long their attitudes last according to different grades.

Case Studies of Firefighter Burns Safety Accident during Fire-fighting Activities (현장 소방활동 중 소방공무원 화상사고 사례 분석 연구)

  • Sin-woong, Choi;So Yun, Lee
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.136-147
    • /
    • 2022
  • The purpose of this study is to analyze four cases of firefighter burns in various fire scenes and to find prevention measures to decrease firefighter injuries. Among the analysis reports prepared by the National Fire Research Institute of Korea from 2016 to 2020, four burn-related accidents are summarized and the main causes are conveyed. The four accidents include second-degree burns from using extinguishers during containment of fires; nine firefighters burned due to re-ignition in the LPG car repair shop; two firefighters injured with third-degree burns from using fire extinguishers during life-saving events in residential housing; and injuries from the radiant heat of the tank BLEVE near the factory fire. These cases are comprehensively investigated in their respective scenes and analyzed based on the fire site investigation reports from the fire department and related theoretical explanations of risk for each accident scene. In the third case study, some experimental research is conducted to evaluate the risk involved with the use of safety gloves. This is evaluated by reviewing Fire Tactics and Standard Operational Procedures (SOP) to determine improvements and recommendations for an efficient firefighting response. Results show that the main causes of burn accidents are the insufficient use of personal protective equipment (PPE), such as safety gloves, and the failure to follow firefighting tactics or SOPs. Through the accident investigation and assessment, it is concluded that to reduce the frequency of burn accidents, the performance of firefighting equipment, SOPs, protection tactics, and safety policy systems require improvement.

Experimental Study to Estimate the Required Flow of Fire Extinguishing System for Flame Spread Prevention on Composite Panel (복합패널 화재확산 방지를 위한 소화시스템의 소요유량 산정을 위한 실험적 연구)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Hwi-Seong;Kim, Yang-Kyun
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.33-39
    • /
    • 2017
  • Composite panel refers to the particular plywood produced in a way of stacking the different kinds of material in sandwich form and adhering them using adhesives and is widely used as building material for its constructability and cost efficiency. But as the surface is finished with steel plate, fire extinguishing agent cannot reach to the core material because of such steel plate on surface which causes the difficulties in suppressing the fire as well as in fire-fighting activities due to collapse. This study, to deal with such problem, is intended to set the fire pipe in core material to prevent the fire from spreading and in a bid to achieve this using minimized fire water, water supply test device was fabricated to estimate the required water flow of fire extinguisher and consequently, optimal water flow (0.5 L/min) was determined through a full-scale fire test.

Estiamtion of Time Series Model on Forest Fire Occurrences and Burned Area from 1970 to 2005 (1970-2005년 동안의 산불 발생건수 및 연소면적에 대한 시계열모형 추정)

  • Lee, Byungdoo;Chung, Joosang
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.6
    • /
    • pp.643-648
    • /
    • 2006
  • It is important to understand the patterns of forest fire in terms of effective prevention and suppression activities. In this study, the monthly forest fire occurrences and their burned areas were investigated to enhance the understanding of the patterns of forest fire in Korea. The statistics of forest fires in Korea, 1970 through 2005, built by Korea Forest Service was analyzed by using time series analysis technique to fit ARIMA models proposed by Box-Jenkins. The monthly differences in forest fire characteristics were clearly distinguished, with 59% of total forest fire occurrences and 72% of total burned area being in March and April. ARIMA(1, 0, 1) was the best fitted model to both the fire accurrences and the burned area time series. The fire time series have a strong relation to the fire occurrences and the burned area of 1 month and 12 months before.

Correlation between the Apartment Resident Community and Housing Satisfaction (아파트 거주자의 커뮤니티와 주거만족도 간의 인과관계)

  • Kim, Myung-Hee;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.3
    • /
    • pp.61-68
    • /
    • 2020
  • This study aims to determine the correlation between the apartment resident community and housing satisfaction and suggest which factors can contribute to improving the local community's housing environment and satisfaction by means of the local inhabitants and apartment residents participating in co-managing the community. The study results are as follows. Firstly, the apartment resident community had a positive effect on housing satisfaction but the effects were insignificant. This revealed that residents' interest in communicating with the resident community was low due to various organizations such as the women's association, election committee, and autonomous society being used as means to pursue personal gain rather than the development of the entire apartment. Secondly, the vitalization of the apartment resident community had a positive effect on housing satisfaction. The analysis results showed that the higher the level of unity and volunteering activities of residents, the more improved the resident vitalization programs are being managed, and the higher the level of resident participation, the higher the housing satisfaction. Lastly, this study suggests the supplementation and upgrading of apartment community facilities into complex community facilities as a means to unify the residents and vitalize the resident community. To vitalize the resident community and strengthen the community spirit, the residents will need to voluntarily create a community hub by forming community-tailored associations and programs through connections with local governments and businesses.

Predicting of Ignition Time and Critical Distance for Ignition of Douglas fir by Radiant Heat of Incandescent Lamp (백열전구 복사열에 의한 미송판의 발화 임계거리 및 발화시간 예측)

  • Lee, Heung-Su;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.2
    • /
    • pp.18-25
    • /
    • 2016
  • The incandescent lamp is an electric light fixture with a tungsten filament heated to a high temperature, by passing an electric current through it, until it glows with visible light. The hot filament is protected from oxidation with a glass bulb that is filled with inert gas. The incandescent lamp has fire risk when combustible materials are close to its glass bulb. Because its lamp has the property which converts 90~95 percents of the electric power to heat energy. 2015 national fire statistics show that fires caused by lighting fixtures were 652 cases, and incandescent lamps(44 cases) and halogen lamps(53 cases) accounted for 15 percents in those of high heating light fixtures. Since incandescent lamp fires account for about 45 percents in the high heating light fixture, we could not overlook the fire risks by the incandescent lamp. Although many studies related with those have been conducted, incandescent lamp fires are continuously occurred. This study was carried out to study the fire risk of ignition of wood due to radiant heat of incandescent lamp. Radiant heat flux of the incandescent lamp was predicted by applying point source model, and critical distance for ignition of wood was calculated by applying integral model. The results from this study could applied to fire prevention activities related to light bulb, and it could be used in fire cause investigations related to radiant heat of incandescent lamp.

Development and Evaluation of Injury Prevention Education Proposal for Elementary School Children (학령기 아동의 사고예방 교육안 개발 및 평가)

  • Lee Jung-Eun;Kim Ji-Hyun;Kim Shin-Jeong
    • Child Health Nursing Research
    • /
    • v.8 no.4
    • /
    • pp.365-380
    • /
    • 2002
  • This study was to develop and evaluate injury prevention education proposal which will helpful and can be utilized directly on the first line spot for elementary school children. Education proposal development and evaluation process was 1) Construction of 10-times education proposal contents proper to schooler 2) Testify validity through 3 pediatric nursing professor and 4 elementary school nurse 3) Pretest was done from March, 2002 to July on 3-6th grade 313 elementary school students 4) Through correction and revision after pretest evaluation meeting, final injury prevention education proposal was developed 5) After 10-times injury education, evaluation was carried out about the degree of help in education contents and general constitution of injury education to total subjects of educated children. Injury prevention education proposal consists of 10 times and each subjects are followings. 1st is 「introduction of injury prevention education and the importance of injury prevention」 2nd is「safety in and around home」, 3rd is 「injury prevention in school」, 4th is 「prevention of violence」, 5th is 「motor vehicle safety」, 6th is 「water safety」, 7th is 「prevention of fire and burns」, 8th is 「toy and product safety」, 9th is 「sports and recretional activities safety」and the final 10th is 「injury prevention caused by animals」. In the evaluation, the degree of help in education contents showed it helped to children averaged 1.66 and general constitution showed averaged 2.17 that children satisfied about developed injury prevention proposal. This study expected to provide systematic and concrete guidance in injury prevention education for elementary school children.

  • PDF

A study on enhancing professionalism of civil anti-disaster organizations for public safety in Korea: with a focus on CAIND (한국 재난관리 체계에서 민간 방재조직의 전문성 제고 방안 - 지역자율방재단을 중심으로 -)

  • Chae, Jong-Sik
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.3
    • /
    • pp.163-178
    • /
    • 2021
  • Purpose: This study explored a plan for improving the overall preventive activity of Korean Citizen-Corps-Active-in-Disaster (CAIND). Methods: The study used the documentary survey and the technical approach methods. This way, detailed information regarding civil anti-disaster organizations was found in scholarly monographs, specialty publications, and master's/doctoral dissertations. It further utilized the statistical yearbooks between 2015 and 2018 from the Korean Ministry of Public Administration, Security, and Fire Service, and the National Statistical Office, to discover practical problems through a statistical analysis. Volunteer activities being inherent, related issues were reviewed at the same time to for purposes of clarifying the characteristics of disaster prevention activity by CAIND. Results: The study provided four major suggestions for improvement. First, the quota management system of Korean CAIND considering the characteristics of rural areas should be supplemented. Second, the education and training systems of Korean CAIND should be established to satisfy regional conditions. Third, management members' readership competency in operating organizations, including that of the Korean CAIND captain in charge, should be strengthened. Fourth, the reward system for Korean CAIND activities should be improved. Conclusion: In the future, the results of this study are expected to be utilized as a basic data to develop Korean CAIND.

Changes in The Amount of Air Respirator Consumed by Field Fire-fighting Activities (현장 소방활동에 따른 공기호흡기 소모량의 변화)

  • Jeon, Jai-In;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.4
    • /
    • pp.93-98
    • /
    • 2019
  • The purpose of this study was to identify and analyze the rate of change of air respirator consumption based on field fire fighting activities, The results of the experiment are as follows. The mean air consumption of the Five subjects was $15.56{\ell}/min$ when standing still, $32.43{\ell}/min$ when walking with normal pace, $43.07{\ell}/min$ when the fire hoses was expanded and arranged, $55.28{\ell}/min$ when climbing stairs, The situation of running up the stairs and hitting the hammer continuously increases to $127.14{\ell}/min$, which means that the consumption of air increases according to the energy consumption. Despite being the oldest, Experimental subject A was $13.23{\ell}/min$ when standing still, $29.33{\ell}/min$ when walking normally, and $41.08{\ell}/min$ when the fire hose was deployed and arranged. This is a result of familiarity with deep and slow breathing methods. The average respiratory use rate of subjects D was $63.58{\ell}/min$. The reason for this is that obesity seems to increase the air consumption, and it is considered that the physical strength is exhausted by the action of the hammer, which has a greater influence on the increase of air consumption. The subject E had significantly lower air respiratory use rate of $49.90{\ell}/min$. The reason for this is that the age of E is the youngest among the subjects, and it is presumed that it possesses strong physical strength.