• Title/Summary/Keyword: fire pattern

Search Result 335, Processing Time 0.031 seconds

Study of Diagnosis Criteria For Fire-Heat Pattern in Stroke Patients (중풍환자의 화열변증 진단 기준에 관한 연구)

  • Kang, Byoung-Kab;Sun, Seung-Ho;Lee, Jeong-Seob;Kim, So-Yeon;Choi, Sun-M;Go, Mi-Mi;Kim, Jeong-Cheol;Bang, Ok-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.6
    • /
    • pp.1486-1490
    • /
    • 2009
  • To develop the diagnostic tool for Fire-heat pattern, we analyzed sensitivity and specificity of symptom signs to diagnose the Fire-heat pattern in stroke patients. Korean medicine doctor surveyed Fire-Heat of the symptoms for the Stroke(KSDS) case report form in stroke patients within 1 month of onset. The sensitivity of "more 1/5 in major sings and 2/11 in helpful sings", "more 2/5 in major sings and 2/11 in helpful sings", "more 3/5 in major sings and 2/11 in helpful sings", "more 1/5 in major sings and 3/11 in helpful sings" "more 2/5 in major sings and 3/11 in helpful sings" "more 3/5 in major sings and 3/11 in helpful sings" are respectively 93%, 59%, 33%, 80%, 53%, 32%. The specificity are respectively 93%, 59%, 33%, 80%, 53%, 32%. The sensitivity(59%) and specificity(80%) of "more 2/5 in major sings and 2/11 in helpful sings" that to be implanted.

Effects of Ventilation Condition on the Fire Characteristics in Compartment Fires (Part II: Multi-dimensional Fire Dynamics) (구획화재에서 환기조건의 변화가 화재특성에 미치는 영향 (Part II: 다차원 화재거동))

  • Kim, Jong-Hyun;Ko, Gwon-Hyun;Park, Chung-Hwa;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.32-38
    • /
    • 2010
  • Multi-dimensional fire dynamics were studied numerically with the change in ventilation conditions in a full-scale ISO 9705 room. Fire Dynamic Simulator (FDS) was used for the identical conditions conducted in previous experiments. Flow rate and doorway width were changed to create over-ventilated fire (OVF) and under-ventilated fire (UVF). From the numerical simulation, it was found that the internal flow pattern rotated in the opposite direction for the UVF relative to the OVF so that a portion of products recirculated to the inside of compartment. Significant change in flow pattern with ventilation conditions may affect changes in the complex process of CO and soot formation inside the compartment due to increase in the residence time of high-temperature products. The fire behavior in the UVF created complex 3D characteristics of species distribution as well as thermal and flow structures. In particular, additional burning near the side wall inside the compartment significantly affected the flow pattern and CO production. The distribution of CO inside the compartment was explained with 3D $O_2$ distribution and flow patterns. It was observed that gas sampling at local positions in the upper layer were insufficient to completely characterize the internal structure of the compartment fire.

A Study on Experimental Characteristics in Fire Investigation Techniques of Flammable Liquids (유류화재의 감식기법의 실험적 특성에 관한 연구)

  • Hwang, Taeyeon;Choi, Donmook
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.7-14
    • /
    • 2012
  • This paper is to develop analytical techniques of flammable liquids which have been used for accelerating fire in accidental fires and arsons. We tested the temperature distribution of ceiling, fire patterns on the floor, and existence of flammable liquids and a check with GC/MS about flammable liquids comparing with papers, newspapers, and clothing. Research findings are as follows. The temperature of ceiling is influenced by flame. So gasoline and thinner was observed that combustible materials would be burned by flame. The fire patten on the floor was observed that flammable liquids had specialized pattern comparing combustible materials. When combustible materials on the PVC (Polyvinyl chloride) floor was burned, they didn't react to the gas detector. But flammable liquids had opposite results. After 7 days, we identified components of fire residues with the GC/MS (Gas Chromatography/Mass Spectrometry) about existence of flammable liquids and got components of flammable liquids. Fire investigation is a complicated processes. But we understand characteristics of materials, need detail investigations, and use the GC/MS to analyse flammable materials.

Study on Influence of Air Flow of Ceiling Type Air Conditioner on Fire Detector Response (천장형에어컨 기류가 화재감지기 작동에 미치는 영향 분석)

  • Choi, Moon-Soo;Lee, Keun-Oh
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.40-45
    • /
    • 2018
  • This paper is an analysis of the influence of ceiling air conditioner airflow on fire detector response. In order to analyze the response characteristics of fire detector while forming air flow of a ceiling-type air conditioner, fire tests were carried out in accordance with ISO standard. This experiment was carried out in a fire test site of 10 m (width) ${\times}$ 7 m (length) ${\times}$ 4 m (height). As a result of the experiment, the response of fire detector shows a normal pattern that is delayed as the distance from the fire source is increased in the absence of the air conditioner, but it is confirmed that the pattern is not maintained in the strong air flow. When the air flow of air conditioner was strong, the response time was increased by 121% in the smoke detector and by 39% in the heat detector. In the case of ceiling type air conditioners, it is considered that the number of fire detectors should be increased, or a detector with high sensitivity should be installed for early detection of fire.

Learning algorithm for flame pattern recognition (화재 패턴 인식을 위한 학습 알고리즘)

  • Kang, Suk Won;Lee, Soon Yi;Lee, Tae Ho
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.521-525
    • /
    • 2009
  • In this paper, we introduce fire detection system and software learning algorithm that recognize fire patterns. Flame patterns means that periodical and consistent pattern about general conception of fire, and to process it with the definition. Learning algorithm for flame pattern recognition that we propose is the method which is faster and more exactly than existing algorithm. Also, we trying to elicit the method through experiment result and by applying it, we show the validity of an early fire warning system.

  • PDF

A Patient with Liver Fire Flaming Upward and Metabolic Syndrome Improved by Korean Medicine: A Case Report (대사증후군이 동반된 간화상염 변증 환자에 대한 한의정신요법 병행 한의치료 증례보고)

  • Jun-Hee, Cho;Jung-Hwa, Lim;Bo-Kyung, Kim
    • Journal of Oriental Neuropsychiatry
    • /
    • v.33 no.4
    • /
    • pp.485-495
    • /
    • 2022
  • The purpose of this study is to report a case of a patient with pattern identification of liver fire flaming upward and metabolic syndrome improved by Korean medicine. The patient felt completely lost. She was treated for headache, insomnia, and metabolic syndrome with Korean medicine and psychotherapy. Pittsburgh Sleep Quality Index (PSQI), Insomnia Severity Index (ISI), Pattern Identification Tool for Insomnia (PIT-Insomnia), Minnesota multiphasic personality inventory-2 (MMPI-2), and bioelectrical impedance analysis (BIA) were used for assessment. During treatment for six months, the patient stopped taking headache pills. Her blood pressure was stabilized. Her body weight, body fat, body mass index (BMI), and visceral fat decreased significantly. The sum of ISI, PSQI, PIT-insomnia also decreased significantly. Her Ego strength increased in the MMPI-2 supplementary scale. We assume that Korean medicine treatment through acupuncture, herbal medicine, and psychotherapy is effective in treating pattern identification of liver fire flaming upward and metabolic syndrome.

Experimental Studies on the Burning Forms of Flammable Liquids (인화성액체의 연소 형태에 관한 실험적 연구)

  • Choi, Seung-Bok;Choi, Don-Mook
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.04a
    • /
    • pp.247-251
    • /
    • 2010
  • The victims of fire are increasing steadily. Fires have been occurred by arson, spontaneous combustion and various causes. As a result of that, the damages of fire got out of hand. Especially, the fires of flammable liquids are can be spreaded easily because of high calorific value and fire loads. These rapid fire spread cause the huge losses of both life and property and the malfunction of extinguishing systems. In these studies, we examined the spread pattern of surface fire on the water surface by the reappearance experiment.

  • PDF

A Study on the Arson Fire Char-acteristics based on Computer Simulation (컴퓨터 시뮬레이션에 의한 방화화재 특성에 관한 연구)

  • Choi, Jin
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2007.11a
    • /
    • pp.239-253
    • /
    • 2007
  • With the development of the Korean economy, the number of arson fire has been radically increased and become a huge problem and issue in Korea Society for last several decades. This study is to establish the fire life safety strategy regarding the arson fire through performing the computer simulation based on fire scenarios with researching domestic fire statistics and cutting edge techniques and methods for fire characteristics and fire dynamic. In addition, to design the fire life safety strategy depending on the arson fire pattern, the flow and characteristics of fire flames and smoke is analyzed by the computer modeling.

  • PDF

The Analysis on Forest Fire Occurrence Characteristics by Regional Area in Korea from 1990 to 2014 Year

  • Jeon, Bo Ram;Chae, Hee Mun
    • Journal of Forest and Environmental Science
    • /
    • v.32 no.2
    • /
    • pp.149-157
    • /
    • 2016
  • Understanding regional characteristics in forest fire occurrence is important to establish effective forest fire prevention policy in Korea. This study analyzed the characteristics of forest fires occurred in 16 administrative districts for recent 25 years (1990~2014) to examine regional characteristics in forest fire occurrence. Forest fire occurrence reflects regional characteristics depending on climatic factors as well as region's society-cultural factors. Results showed that the first cause of forest fire occurrence was carelessness by human activities throughout all administrative districts, however, the second cause depends on regional characteristics. As the results of forest fire occurrence period analyzed for 10 days, the most forest fires occurred in the southern region during January to March, while forest fires in the northern region occurred mostly during March to April. We classified forest fire occurrence patterns into three types (centralized: Gyeonggi-do, dispersal: Busan, horizontally distributed: Gyeongsangnam-do) by multi-temporal analysis for forest fire occurrence period.