• Title/Summary/Keyword: fire of the vehicle

Search Result 298, Processing Time 0.023 seconds

Risk Analysis of Jet Flame Occurred at Hydrogen Fuel Cell Vehicle (수소자동차의 제트화염 발생에 따른 위험성 분석)

  • Byoungjik, Park;Yangkyun, Kim;Ohk Kun, Lim
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.158-165
    • /
    • 2022
  • Eco-friendly policies proposed by the government of The Republic of Korea have encouraged the use of eco-friendly vehicles. Hydrogen vehicles have exhibited the highest growth rate, although the current number of registered vehicles is low. In hydrogen vehicles, a thermally activated pressure relief device (TPRD) is installed to prevent explosions in the hydrogen gas cylinder. When discharged due to low ignition energy, hydrogen gas readily forms a jet flame. The risks induced by such jet flames were analyzed through a numerical analysis. Jet flames can activate TPRDs installed in nearby hydrogen gas cylinders. As a result, high-voltage cables exposed in the lower area of a vehicle can ignite within seconds. There was a 9.5-kW/m2 area around the vehicle (which can result in casualties) at a distance of ~5 m from the hydrogen gas cylinder, and a 37.5-kW/m2 area (which can cause significant damage) in the form of an inverted triangle toward the lower section of the vehicle. We believe that the risk factors analyzed herein should be considered for addressing accidents in hydrogen vehicles.

A Study on the Improvement of Structure of Urban Transit Vehicle Considering Elevation of Fire Safety (화재안전성 향상을 고려한 도시철도 차량의 구조개선에 관한 연구)

  • Kim Kyu-Joong;Lee Seung-Yong;Lee Kuen-Oh
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.15-20
    • /
    • 2005
  • This is a comparative study where we compare simulation results with model examining the time and direction the fire spreads when it breaks out. Also there is vertical distribution of temperature in carriage where the fire spreads out. This study is about demonstrating how to establish smokeless system in urban vehicle, about its necessity, and about vehicle system restructuring, This study also makes an effort to find more advanced method for efficient fire safety in trains, In existing vehicles, in case of fire, the smoke can't go out when doors are closed and hence it spreads in whole train. Even though the method of using ventilation or exhaust established inside the carriage to throw smoke out is much better than the way of opening end doors in each carriage, this study is trying to do research on second way. Through simulation we see that in second case, even though not as good as the first one, smoke can exit through gates. Even though the first method is better, the second can also be uses to let fire out. We can know that in the first case as the smoke can exit out faster, it provides more safety for people. So this system provides better fire safety condition.

  • PDF

The Evaluation of Fire Reliability for the High Pressure Hydrogen Storage System of Fuel Cell Vehicle (I) (연료전지자동차의 고압수소저장시스템 국부화재 신뢰성 평가 (I))

  • Kim, Sang-Hyun;Choi, Young-Min;Hang, Ki-Ho;Shim, Ji-Hyun;Hang, In-Cheol;Lim, Tae-Won
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.4
    • /
    • pp.520-526
    • /
    • 2011
  • In recent years, it is very important that hydrogen storage system is safe for user in any circumstances in case of crash and fire. Because the hydrogen vehicle usually carry high pressurized cylinders, it is necessary to do safety design for fire. The Global Technical Regulation (GTR) has been enacted for localized and engulfing fire test. High pressure hydrogen storage system of fuel cell electrical vehicles are equipped with Thermal Pressure Relief Device (TPRD) installed in pressured tank cylinder to prevent the explosion of the tank during a fire. TPRDs are safety devices that perceive a fire and release gas in the pressure tank cylinder before it is exploded. In this paper, we observed the localized and engulfing behavior of tank safety, regarding the difference of size and types of the tanks in accordance with GTR.

A Study on Maintainability Improvement for Underwater Weapon Training Vehicle (수중무기 훈련탄의 정비성 향상방안 연구)

  • Jeong, Jinseob
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.111-117
    • /
    • 2013
  • In this paper, we have proposed novel technique to improve maintainability for training vehicle of underwater weapon system. In case of under water weapon, the fire procedure is related with operation of expulsion system in submarines. So the submarine crews should practice the complex fire procedure of weapon system by using training vehicle, which is safer and cheaper than operational weapon. After emitted from submarine, the training vehicle rise to the surface and should be withdrawn from the sea. The recovered training vehicle is transported to maintenance depot and pass through the recycling procedure including disassembling the vehicle, data acquisition & analysis, battery charge, replacing expandable components, testing the captive equipment, and assembling the vehicle. The disassembling & assembling of training vehicle which is composed of watertight section or airframe, is time-consuming work. So in this paper, we have studied the elements of recycling procedure and propose the method to exclude the assembling & disassembling work for maintainability improvement.

On the Occurrence of Defects by Vehicle Type According to the Fire-fighting Vehicle Detailed Inspection (소방차량 정밀점검 분석에 따른 차종별 결함 발생에 관한 연구)

  • Lee, Jang Won;Han, Yong-Taek
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.112-119
    • /
    • 2021
  • Purpose: This study is based on the detailed inspection data for the last 6 years of fire-fighting high ladder vehicles, fire-fighting inflected ladder vehicles, fire-fighting chemical vehicles and fire-fighting pump vehicles used in front-line fire departments. The purpose is to contribute to the technological development of fire-fighting vehicles by grasping the implementation status of each city and province, the rate of defects, and the occurrence of defects by year. Method: The implementation status by city and province, defect incidence rate, and defect occurrences by year were analyzed. Result: From 2012 to 2017, when the average of 230 or more overhaul vehicles was requested, the results of each city/province show slight fluctuations, but the number of defects gradually decreased due to the old fire-fighting vehicle replacement project and the response of fire vehicle manufacturers. Conclusion: In the case of fire-fighting ladders, the incidence rate of defects was found to be in the order of elevator device, electric device, ladder device, and pneumatic supply device. And in the case of the fire fighting ladder, it was confirmed that the incidence of defects appeared in the order of the refractive ladder, hydraulic cylinder, hydraulic oil, and pneumatic supply device. In the case of fire-fighting chemical vehicles, it was confirmed that defects occurred in the powder fire extinguishing device, fire pump, vacuum pump, and pneumatic supply device.

Analysis of Interaction Between Recirculating Flow Near The Jet Fan and The Backlayer of Smoke in a Road Tunnel (도로터널에서 제트팬 근처의 재순환유동과 연기 역류현상의 상호작용 분석)

  • Kim, Chang-Kyun;Ryu, Jin-Woong;Kim, Sung-Joon
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.191-201
    • /
    • 2005
  • A numerical analysis was done for a tunnel fire in a 1000m road tunnel. A cartesian coordinate was adopted to make a computational grid sytem which has 448,000 computational cells. A transient flow phenomena in the tunnel was simulated by the commercial code of PHEONICS from the ignition of fire to 600 seconds by the interval of 100 seconds. Total computational time of about 44 hours was required to get a convered solution in each time step. The purpose of this research is to analyze of the backlayering pheonomena and recirculation flow in a tunnel. The compuational results say that the backlayering does not happens near the fire of vehicle in this case because the vehicle fire is located at the outside of recirculation zone of flow ocuured near the jet fan. In this research, onset of backlayering pheonomena could be escaped if jet fan is set 95m in front of the the fire of vehicle.

  • PDF

Radio Frequency Based Emergency Exit Node Technology

  • Choi, Youngwoo;Kim, Dong Kyoo;Kang, Do Wook;Choi, Wan Sik
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.2 no.1
    • /
    • pp.91-100
    • /
    • 2013
  • This paper introduces an indoor sensor fusion wireless communication device which provides the Location Based Service (LBS) using fire prevention facility. The proposed system can provide information in real time by optimizing the hardware of Wi-Fi technology. The proposed system can be applied to a fire prevention facility (i.e., emergency exit) and provide information such as escape way, emergency exit location, and accident alarm to smart phone users, dedicated terminal holders, or other related organizations including guardians, which makes them respond instantly with lifesaving, emergency mobilization, etc. Also, the proposed system can be used as a composite fire detection sensor node with additional fire and motion detect sensors.

A Study on Torsional Stiffness Improvement of a Vehicle (자동차의 비틀림 강성 향상에 관한 연구)

  • 임기창;임석현
    • Fire Science and Engineering
    • /
    • v.11 no.1
    • /
    • pp.47-54
    • /
    • 1997
  • Using high tensile steel plate makes the vehicle body stiffness lower even though it can lessen the fuel consume rate in application of weight reduction. The crack which happens arround vehicle window glass is brought about due to fatigue with low torsional stiffness. The paper presents a most suitable way to increase torsional stiffness using elasticity theory. Also the result of this study shows good agreement with FEM and experiments. We used a passenger car for calculation in this paper. Because we can apply the result of this study to fire engine as well as passenger car.

  • PDF

Fire Power Analysis for Concept Exploration of Combat Vehicle (전투차량체계의 개념탐색을 위한 화력성능분석)

  • Lim, O-Kaung;Choi, Eun-Ho;Ryoo, Jae-Bong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.3
    • /
    • pp.251-258
    • /
    • 2009
  • At the stage conceptual design, combat vehicle is classified into three general categories of fire power, mobility and physical properties of system. The present research is restricted to fire power and its optimization. At the stage of conceptual designing of system, it is appropriate to consider major variables affecting fire power - including the weight of bullet, which exerts a direct influence on destroying effect, maximum range which takes long range firing in consideration. To estimate the maximum firing range, a simple interior ballistic and an exterior ballistic model were built by using the lumped parameter method, Le Duc method and point mass trajectory model. Design of experiment and regression analysis was used to derive simulations of fire power. Finally, response surface models were built and design variables were analyzed.

A experimental Study on Insulation Breaking Fire Case of Starter Motor B Terminal (스타트모터 B단자 절연파괴 화재사례에 대한 실험적 연구)

  • Woo, Seung Woo;Park, J.M.;Hyun, B.S.;Nam, J.W.;Park, W.S.;Kim, J.P.;Cho, Y.J.;Goh, J.M.;Park, N.K.
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.55-62
    • /
    • 2019
  • In this paper, we introduce a case of a fire accident during parking of a large truck that is repeatedly occurring. The shape and location of the combustion and electrical singularity commonly found in other vehicle fire accidents could limit the starter motor as the ignition section. In addition, it was possible to confirm the electrical melting singularity that could act as a cause of ignition between the start motor B terminal and the start motor enclosure. By combining the above investigations and investigations, it was possible to estimate the electric fire expressed from insulation breaking of the starter motor B terminal, and by using the renewable starter motor comparison product mounted on the fire vehicle, an experiment was performed to reproduce the ignition process from the starter motor under specific conditions. So. It is hoped that this will raise awareness about vehicle fires, which can lead to large fires or casualties, share the risks of using starter motors for regeneration, and help in the rapid and accurate investigation of similar vehicle fires in the future.