• 제목/요약/키워드: fire loads

검색결과 145건 처리시간 0.029초

Collapse Initiation and Mechanisms for a Generic Multi-storey Steel Frame Subjected to Uniform and Travelling Fires

  • Rackauskaite, Egle;Kotsovinos, Panagiotis;Lange, David;Rein, Guillermo
    • 국제초고층학회논문집
    • /
    • 제10권4호
    • /
    • pp.265-283
    • /
    • 2021
  • To ensure that fire induced collapse of a building is prevented it is important to understand the sequence of events that can lead to this event. In this paper, the initiation of collapse mechanisms of generic a multi-storey steel frame subjected to vertical and horizontal travelling fires are analysed computationally by tracking the formation of plastic hinges in the frame and generation of fire induced loads. Both uniform and travelling fires are considered. In total 58 different cases are analysed using finite element software LS-DYNA. For the frame examined with a simple and generic structural arrangement and higher applied fire protection to the columns, the results indicate that collapse mechanisms for singe floor and multiple floor fires can be each split into two main groups. For single floor fires (taking place in the upper floors of the frame (Group S1)), collapse is initiated by the pull-in of external columns when heated beams in end bays go into catenary action. For single floor fires occurring on the lower floors(Group S2), failure is initiated (i.e. ultimate strain of the material is exceeded) after the local beam collapse. Failure in both groups for single floor fires is governed by the generation of high loads due to restrained thermal expansion and the loss of material strength. For multiple floor fires with a low number of fire floors (1 to 3) - Group M1, failure is dominated by the loss of material strength and collapse is mainly initiated by the pull-in of external columns. For the cases with a larger number of fire floors (5 to 10) - Group M2, failure is dominated by thermal expansion and collapse is mainly initiated by swaying of the frame to the side of fire origin. The results show that for the investigated frame initiation of collapse mechanisms are affected by the fire type, the number of fire floors, and the location of the fire floor. The findings of this study could be of use to designers of buildings when developing fire protection strategies for steel framed buildings where the potential for a multifloor fire exists.

교육시설 화재위험성 평가를 위한 기초조사에 관한 연구 (A Study on the Basic Investigation for the Fire Risk Assessment of Education Facilities)

  • 이성일;함은구
    • 한국재난정보학회 논문집
    • /
    • 제17권2호
    • /
    • pp.351-364
    • /
    • 2021
  • 연구목적: 교육시설 화재위험성 평가를 위한 기초 데이터 확보를 위하여 화재하중 분석하였다. 사전조사로 화재하중을 산정하기 위해 학교시설의 화재하중과 관련된 기초자료를 수집하였다. 연구방법: 기초자료는 화재하중의 정의 및 종류, 화재하중 산정을 위한 연소열 데이터 화재하중에 대한 선행연구를 통하여 진행하였고 화재하중 산출시 구획실에 존재하는 가연물 중량에 해당 연소열을 곱하여 산정하였다. 연구결과: A 초등학교의 고정가연물은 교실, 음악실, 교무실은 정서나 안전을 고려하여 바닥이 주로 목재로 이루어져 있었으며, 나머지 구획실은 석재로 이루어졌다. 천장과 벽은 석고보드, 콘크리트로 되어있어 가연물에 속하지 않았다. 각 실별로 대표적인 적재가연물은 교실은 책상, 의자, 사물함 등으로 나타났으며 과학실은 실험기구함, 실험도구함이 주를 이루어었으며 도서실은 책과 서가, 열람기구 등이 큰 비중을 차지하였다. 결론: A 초등학교의 적재가연물에 따른 적재화재하중은 도서실, 컴퓨터실, 영어학습실, 교무실, 일반교실, 과학관, 음악실의 순으로 나타났다.

전기화재 징후 감지를 위한 아크전류 파형분석에 관한 연구 (A Study on Analysis of Arc Current Waveforms for Detection of Prognostics of Electrical Fires)

  • 황진권
    • 한국화재소방학회논문지
    • /
    • 제23권1호
    • /
    • pp.7-14
    • /
    • 2009
  • 전류 돌입형, 비선형 및 전류 단속형 부하들은 정상작동 상태에서 아크 발생의 경우와 유사한 전류파형을 갖는다. 이러한 부하들에서 아크 검출기법을 정확하게 구현하기 위하여서는 아크 유무에 따른 전류파형의 전형적인 특징을 찾을 필요가 있다. 본 논문에서는 UL 1699의 직렬과 병렬 아크 발생장치들로 이러한 부하들에 마크를 발생시키고 시간 및 주파수 영역에서 아크 전류파형을 분석한다. 아크 실험의 분석결과를 통하여 아크 전류파형의 전형적인 특징은 시간영역에서는 영점전류의 처짐 현상이고 주파수영역에서는 60Hz 고조파 성분을 제외한 전대역의 주파수에 걸쳐서 스펙트럼 크기가 증가되는 것임을 보인다. 비선형 및 전류 단속형 부하들에서 시간영역보다는 주파수영역의 아크 전류의 특징이 보다 명확히 나타남을 보인다. 본 논문에서 제시된 아크 전류파형의 특징들은 아크 차단기 개발을 위한 기반자료로 활용될 것으로 기대된다.

ECC로 피복된 고강도콘크리트의 폭렬저감 및 열적특성에 관한 실험적 연구 (Fire Resistant Performance of Anti-Spalling ECC Layers in High-Strength Concrete Structures)

  • 이재영;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.199-202
    • /
    • 2008
  • The purpose of this study is to obtain the fundamental fire resistance performance of engineered cementitious composites(ECC) under fire temperature in order to use the fire protection material in high-strength concrete structures. The present study conducted the experiment to simulate fire temperature by employing of ECC and investigated experimentally the explosion and cracks in heated surface of these ECC. In the experimental studies, 3 HSC specimens are being exposed to fire, in order to examine the influence of various parameters(such as depth of layer=20, 30, 40mm; construction method=lining type) on the fire performance of HSC structures. Employed temperature curve were ISO 834 criterion(3hr), which are severe in various criterion of fire temperature in building structures. The numerical regressive analysis and proposed equation to calculate ambient temperature distribution is carried out and verified against the experimental data. By the use of proposed equation, the HSC members subjected to fire loads were designed and discussed.

  • PDF

화재하중에 따른 구획화재 실험 연구 (The Study on Compartment Fire Experiment According to Fire Load)

  • 권오상;김흥열
    • 한국화재소방학회논문지
    • /
    • 제31권6호
    • /
    • pp.16-22
    • /
    • 2017
  • 국내에서는 복잡해지고 다양해지고 있는 건축물에서의 화재위험에 대응하기 위해 성능기반 화재안전 설계가 논의되고 있지만, 건축물에서의 다양한 인자들에 의한 화재특성의 에측의 어려움으로 인하여 성능기반 화재안전 설계의 도입이 제한되고 있다. 본 연구에서는 뉴질랜드에서 제시하고 있는 화재위험도별 화재하중 값의 실대형 화재실험을 통해 성능기반 설계 도입을 위한 기준 방향 설정 및 기초 자료로 사용하고자 하였다. 실대형 화재실험은 10 MW급의 실대형 칼로리미터에서 $0.8(L){\times}2.0(H)m$의 단일 개구부를 포함하고 있는 $2.4(L){\times}3.6(W){\times}2.4(H)m$ 크기의 시험체 틀의 내부에 목재 크립을 화재하중에 따라 배치시켜, 목재 크립이 전소할 때 까지 진행하였다. 화재실험에서 열방출률의 변화는 목재 크립에 화염이 착화 된 후 외부로 출화되는 약 90초 이후부터 급격히 증가하였으며, 위험도 레벨 1에서는 최대 4743.4 kW의 열발출률이 실험시작 후 244 초에 측정되었고 위험도 레벨 2에서는 5050.9 kW의 최대 열방출률이 497 초에 측정되었다. 또한 위험도 레벨 3에서는 최대 열방출률이 4446.9 kW로 실험시작 677 초에 측정되었다.

내화패널이 부착된 프리캐스트 PSC 풍도슬래브의 정적/동적하중에 관한 실험연구 (Experimental Studies on PSC Airpit-Slab with Fire Resistance Panel under Static and Dynamic Loads)

  • 김태균;배정;최헌;민인기
    • 대한토목학회논문집
    • /
    • 제32권4A호
    • /
    • pp.245-253
    • /
    • 2012
  • 본 연구에서는 장대터널이나 지하차도 등에 시공되는 횡류식 환기시스템을 구성하는 내화패널이 부착된 프리캐스트 풍도슬래브의 구조성능을 평가하기 위해서 실물모형 구조실험을 수행하였다. 또한, 내화패널의 휨강도와 Pull-off test를 통하여 내화패널과 슬래브의 부착성능 등의 기초성능을 우선적으로 확인하였다. 실물모형시험은 내화패널과 프리캐스트 PSC 슬래브의 정적 휨성능과 차량의 통행 시 발생하는 표면압력 이상의 하중에 대한 동적피로부착성능을 평가하였다. 동적피로하중 시험에서 내화패널과 PSC 슬래브 사이의 탈락이나 손상은 발생하지 않았으며, 정적재하시험에서도 매우 안정적인 거동을 보였으며, 하부에 부착된 내화패널의 탈락은 발생하지 않았다. 따라서 시공 중이나 시공 후 외부하중에 의해 내화패널의 탈락은 발생하지 않을 것으로 판단된다.

일정 축력을 받는 콘크리트충전 각형 강관기둥의 내화성능 평가 (An Evaluation for the Fire Resistance of Concrete-Filled Steel Square Tube Columns under Constant Axial Loads)

  • 박수희;류재용;정경수;최성모
    • 한국강구조학회 논문집
    • /
    • 제19권6호
    • /
    • pp.703-714
    • /
    • 2007
  • 본 연구에서는 수치해석에 의해 일정 축력을 받는 콘크리트충전 각형강관(각형 CFT) 기둥의 내화성능을 평가하였다. 본 연구에 앞서 각형 CFT 기둥의 실대 내화성능평가 실험을 수행하였으며, 이로써 무내화피복 상태에서 CFT 기둥 자체만의 내화성능을 평가하였다. 강관은 SPSR 400 강재를 사용하였으며 강관 내에는 27.5MPa와 37.8MPa 강도의 콘크리트를 사용하였다. 콘크리트 강도, 작용 하중비와 기둥단면 직경을 변수로 설정하였다. 수치해석에 의해 예측된 내화성능의 타당성을 검증하기 위하여 실험결과값과 비교 평가해 본 결과, 해석값과 실험값이 서로 잘 일치하거나 해석값이 약간 저평가하고 있음을 확인하였다. 따라서 본 수치해석에 의한 CFT기둥 내화성능 예측은 타당하다고 판단된다. 내화성능 영향인자의 분석 결과, 축력비($N/N_c$)가 동일한 경우 콘크리트 강도가 적을수록 내화성능이 우수하며 단면직경이 클수록 내화성능은 향상되었다.

표준화재 재하조건 콘크리트 중공슬래브의 피복두께에 따른 화재거동에 관한 실험적 연구 (An Experimental Study on the Fire Behavior of Concrete Void Slab under Standard Fire with Loading Condition)

  • 김흥열;김형준;조범연;여인환;권인규
    • 한국화재소방학회논문지
    • /
    • 제25권6호
    • /
    • pp.64-72
    • /
    • 2011
  • 기존의 무량판 구조와 동일한 콘크리트 중공슬래브구조는 구조적 하중지지 성능이 불필요한 슬래브 단면상의 중앙부 콘크리트를 제거하여 슬래브의 자중을 줄이고 무량판 구조의 단점을 보완하여 장점을 극대화시킨 구조형식이다. 본 연구에서는 콘크리트 중공슬래브 공법의 실제 스팬길이인 7.5 m에서 슬래브 피복두께에 따른 화재거동 영향성 분석을 위하여 화재실험을 수행하였다. 하중조건은 고정하중과 적재하중을 고려하여 실험체에 등분포 조건으로 사전 재하하였으며, 표준화재조건으로 재하가열 실험을 수행하였다. 슬래브의 화재가열 노출면으로부터의 깊이별 온도변화와 처짐변형 특성을 측정하였으며, KS F 2257-1 평가기준에 의거하여 슬래브의 내화성능을 평가하였다. 실험결과 피복두께 50 mm를 확보할 경우, EPS 중공체로 제작한 실험체의 경우 약 2시간 정도의 내화성능을 확보할 수 있는 것으로 나타났다.

LIMITATIONS OF SPHERE ANEMOMETRY FOR LOW GAS VELOCITY MEASUREMENTS

  • Han, J.Y.;O.F. Turan
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.297-304
    • /
    • 1997
  • Sphere anemometry technique is re-visited for low gas velocity measurements during full-scale fire tests. This technique has the advantage of requiring only one channel per sphere for data acquisition, in addition to being cheap and rugged, The results indicate that the technique is useful for small fuel load burns with low radiation levels. For large fuel loads, the usefulness is up to sprinkler activation temperatures.

  • PDF