• Title/Summary/Keyword: fire guard

Search Result 40, Processing Time 0.027 seconds

A Fundamental Research on the Safety Facilities of Railroad (철도 선로안전시설에 관한 기초연구)

  • Lee Seong-Won;Kim Seung-Hwan;Shin Seung-Kyo;Kim Tae-Wook
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.550-555
    • /
    • 2005
  • In this research, safety requirements for guard rail, buffer stop, car stop scotch block, protection device, fire protection facilities, safety siding, escape facilities and inundation protection facilities are studied to establish a standard. First, various kinds of guard rails and their construction methods are investigated. Researches on the level difference of main track and guard rail, joint, length, and fastening force of guard rail are done. Second, the classification of buffer stop and car stop scotch block and its characteristics are examined, and the impact force, speed limit and capacity of buffer stop are summarized. Details of protection device, fire protection facilities, safety siding, escape facilities and inundation protection facilities are also investigated. From this fundamental research results, basic data on the safety facilities of railroad system are established.

  • PDF

A Study on the Safety Facilities of Urban Railway (I) (도시철도 선로안전시설에 관한 고찰(I))

  • Lee Seong-Won;Kim Seung-Hwan;Shin Seung-Kyo;Kim Hong-Seuk
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1150-1155
    • /
    • 2004
  • In this paper, safety requirements for guard rails, buffer stops, defensive structures, anti-fire facilities, and safety sidings are studied to establish a standard. Various kinds of guard rails and their construction methods are investigated. Researches on the level difference of main track and guard rail, joint. length, and fastening force of guard rail are done. The classification of buffer stops, defensive structures, anti-fire facilities, and safety sidings and its characteristics are examined. From this study, fundamental data on the safety facilities of urban railway system are established.

  • PDF

A study for introduction plan of Evacuation Exit ladder in apartment (아파트에 있어서의 피난사다리 도입 방안에 관한 연구)

  • Kim, Tae-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.11-16
    • /
    • 2008
  • The trend of constructing skyscraper has arisen to the offistel and apartment complex due to the lack of exploitable land and urbanization. But, the phenomenon of the multi-story buildings is different from the regular building because of the possibility of mass disaster in fire. Therefore, Analyzing and comparing our actual condition and Japanese, It is going to be suggested that the introduction of fire escape ladder for residents in emergency.

  • PDF

A Study on Fire Detection in Ship Engine Rooms Using Convolutional Neural Network (합성곱 신경망을 이용한 선박 기관실에서의 화재 검출에 관한 연구)

  • Park, Kyung-Min;Bae, Cherl-O
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.4
    • /
    • pp.476-481
    • /
    • 2019
  • Early detection of fire is an important measure for minimizing the loss of life and property damage. However, fire and smoke need to be simultaneously detected. In this context, numerous studies have been conducted on image-based fire detection. Conventional fire detection methods are compute-intensive and comprise several algorithms for extracting the flame and smoke characteristics. Hence, deep learning algorithms and convolution neural networks can be alternatively employed for fire detection. In this study, recorded image data of fire in a ship engine room were analyzed. The flame and smoke characteristics were extracted from the outer box, and the YOLO (You Only Look Once) convolutional neural network algorithm was subsequently employed for learning and testing. Experimental results were evaluated with respect to three attributes, namely detection rate, error rate, and accuracy. The respective values of detection rate, error rate, and accuracy are found to be 0.994, 0.011, and 0.998 for the flame, 0.978, 0.021, and 0.978 for the smoke, and the calculation time is found to be 0.009 s.

A Study on the Methods of Fire-Safety in Cultural Property Wooden Buildings (목조 문화재 건축물의 화재 방재를 위한 조사 연구)

  • Chang, Hyung-Soon;Cho, Won-Seok;Kim, Heung-Gee
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.10 no.4
    • /
    • pp.25-32
    • /
    • 2008
  • The prevention of disasters in cultural property is very important management and historical duties. The reason can't be measured values with monetary scale of our contemporary. Therefore, this paper was considered fire-safety as one of terrible threat-disasters about the wooden buildings. This research deal with 47 cases cultural property wooden building by whole investigation(field survey and interview) in Gangnung province. The most buildings have basic fire extinguisher; ABC powder. A few buildings are rarely installed fire extinguishing equipments; outdoor fire hydrant, heat sensor, ground sprinkler, CO2-hose-reel. But these state is very insufficient for the fire-safety in cultural property wooden buildings. Specially as particular attention in province, forest fire of regional characteristic have close relation with cultural property fire. The majority of factor against forest and building fire is to provide monitoring and security system; CCTV, Fence, Sensor, Alarm and paid guard man against incendiary. Ultimately it is necessary to construct comprehensive disaster prevention system with the organic cooperation such as National Emergency Management Agency, Cultural Heritage Administration, Forest Service, local government officials and regional citizen.

  • PDF

A Study on the Improvement of System to Prevent Accidents during Welding and Melting Operations (용접·용단 작업 중 사고 예방을 위한 제도 개선 연구)

  • Han, Kyung-Su;Cho, Guy-Sun;Kim, Young-Se;Kim, Byung-Jik;Park, Ju-Yeong;Park, Gyo-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.1
    • /
    • pp.76-81
    • /
    • 2020
  • Recently, fire and explosion accidents caused by sparks scattered during welding and melting work in the work place where flammables are present. The causes of such fire accidents are mostly non-compliance with basic safety rules such as the removal of hazardous goods and the prevention of sparks scattering. It is strongly recommended to revise Industrial Safety and Health Act. This study analyzes the fire and explosion accidents in the work of firearms, such as welding and melting work, and analyzes the causes from a system perspective, and proposes an improvement plan for the system such as expanding the number of fire monitors, pre-approval of fire risk work, and intensifying fire prevention safety education.