• Title/Summary/Keyword: fire growth

Search Result 349, Processing Time 0.035 seconds

The observation on eating impact on psychological aspect (식생활이 정서에 미치는 영향에 대한 고찰)

  • Bang, Jung-Kyun
    • Journal of Oriental Neuropsychiatry
    • /
    • v.16 no.2
    • /
    • pp.125-133
    • /
    • 2005
  • Object : This paper is designed to inquire into the influence of eating habits on the emotion of modem people. Method : The methodology is used that searches for materials such as books and treatises on the relationship between eating habits and emotion. Result : Meat used for fast food comes from cows that are fed the feed containing growth hormone and antibiotic. Growth hormone extremely supplements fire or yang within the body while antibiotics undermines the process of yin, leading to an accumulation of damp-heat and inflammation of ministerial fire. Additives contained in instant foods also impinge on the process of yin, leading to poor digestion, damp-heat toxins and ministerial fire. Excessive consumption of meat results in incomplete combustion of fat and hinders the formation of essence. Subsequently, ministerial fire becomes hyperactive as a result of the lack of yin energy. Increased meat consumption in the human diet is coupled with unhealthy eating pattern in which people eat too much for dinner and too quickly. Eating too much disturbs digestion, making it slow and incomplete, leading to excess damp-heat conditions, insufficient amount of vital essence and eventually hyperactive ministerial fire. Milk is considered a catalyst of faster growth, making it suitable for calves. Milk intake rapidly increases the balance of yang and eventually cause hyperactivity of ministerial fire. Conclusion : It is estimated that the eating habits of modern people cause the process of yang, making them feel restless, impatient and aggressive.

  • PDF

Heat Risk Assessment of Wood Coated with Boron/Silicone Sol (붕소/실리콘 졸로 도포된 목재의 열위험성 평가)

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.9-20
    • /
    • 2019
  • This study was examined fire risk properties of wood specimen for the constructional interiors, especially focusing on the fire performance index (FPI) and the fire growth index (FGI) as heat hazard characteristics. Flame retardants were synthesized using boric acid, boronic acid and tetraethoxyorthosilicate. Heat release characteristics were measured by using a cone calorimeter (ISO 5660-1) and cypress was used. The external heat flux as fire intensity was maintained at 50 kW/㎡. The measured fire performance index (FPI) after burning was increased by 1.6 times for boric acid/silicone (BA/Si) sol, each 1.1 times for isobutylboronic acid/silicone (IBBA/Si) sol and phenylboronic acid/silicone (PBA/Si) sol compared with cypress. Fire risk by the fire performance index was increased BA/Si, IBBA/Si ≈ PBA/Si order. The fire growth index was decreased 94% for the BA/Si and 8% for the IBBA/Si sol, and was increased by 17% for the PBA/Si sol. Fire risk by the fire growth index was increased BA/Si, IBBA/Si, PBA/Si order. Overall fire risk was higher in the order of BA/Si < IBBA/Si < PBA/Si.

Fire Risk Rating Evaluation of Organic Insulation Materials (유기 단열재의 화재위험성 등급 평가)

  • You, Ji Sun;Jeon, Nam;Chung, Yeong-jin
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.417-422
    • /
    • 2021
  • In this study, poly isocyanurate foam (PIR), poly urethane foam (PUR), and phenol foam (PF) of organic insulation materials were selected, and investigated using a cone calorimeter, as per ISO 5660-1. Standard materials (PMMA) were used to standardize the fire hazard assessment, and the fire risk was classified and evaluated by Chung's equations-III and IV. The fire performance index-II value of Chung's equations-II was the highest value with PF of 14.77 s2/kW. And the PUR was 0.08 s2/kW, the lowest value of fire performance index-II value. The fire growth index-II value was the lowest value with PF of 0.01 kW/s2. And the PUR was 1.14 kW/s2, the highest value of fire growth index-II value. The fire performance index-III (FPI-III) of Chung's equations-III had the lowest value for PUR (0.11) and the highest for PF (20.23). The PUR showed the highest value of the fire growth index-III (FGI-III) as 14.25, while the PF exhibited 0.13 regarded as the safest materials. The fire risk index-IV (FRI-IV) value of Chung's equation-IV was in the following order: PUR (130.03) >> PIR (19.13) > PMMA (1.00) > PF (0.01). Therefore, it was concluded that the fire risk associated with PF is the lowest, whereas that associated with PUR is the highest.

An Experimental Study on Characteristics of Sprinkler Head Activation in Low Growth Rate Fire (저성장속도 화재에서의 스프링클러 헤드 동작특성에 관한 실험적 연구)

  • Choi, Yong-Seob;Yoon, Jong-Chil
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.26-35
    • /
    • 2016
  • Sprinkler installations shall be operated at normal operating temperature of the atmosphere as a fire sprinkler head in any facility to control and extinguish the fire when the fire initially. Recently, however, some flush type quick response automatic sprinkler heads in slow fire place is a problem that can not be normal operation are raised. In this paper, by using the experimental model of the Apartment house of Commons and Cabinet burner size bedrooms fire conditions to form a slow growth rate and can supply more than 0.2 MPa pressure is the minimum pressure that can be applied inside the pipe in the field experiment was conducted. In the majority of experiments lush type quick response automatic sprinkler heads which is used in the country it was confirmed to be incompletely opened as the Cold Soldering occur. This phenomenon is likely to fail early fire suppression and control because they can cause the spread of fire and casualties needed to complement domestic product testing and type approval standards through additional research.

LATEST INTERNATIONAL DEVELOPMENTS IN PASSIVE FIRE PROTECTION

  • Marx, Olliver
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.227-243
    • /
    • 1997
  • Fire and smoke can from a small ignition source develop rapidly. Active systems in combination with Passive Fire Protection measures will offer highest safety standards to the building's developers and occupants. Nevertheless, the fire growth is very unpredictable and it is therefore essential at the planning stage that tested solutions are well selected according to National codes and later on installed by qualified contractors to ensure optimum performance. This demonstrates that Passive Fire Protection as safety measure cannot be neglected. Recent fire cases all over the world still proof that fire can develop any time and any where even in countries of high safety standards.

  • PDF

A Study on the Risk Management Information System of the Underground Space - focused on Fire Growth Risk Assessment System- (지하공간의 위험관리정보시스템에 관한 연구 -화재확산평가시스템 중심으로-)

  • 박종근;노삼규
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.49-58
    • /
    • 2002
  • A large number of accidents at an underground place have been happening, including the gas explosion under construction of subway; the fires of underground utility and underground shopping malls, and other explosion, at home and abroad recently. These accidents make the function of a city ineffective due to the paralyses of electricity and communications net as well as the loss of property and cause people to feel unsecured with accompaniment of a heavy of toll of lives. This research will show evaluation methods of a numerical value of expected average loss space of combustion with the use of probability in order to present potential risk of combustion growth that underground space might cause, and how designer decides a system that enables us to compare and evaluate relatively the effectiveness of measures for preventing burning by calculating the expansion route and the damage size of burning in case of fire.

Numerical study to reproduce a real cable tray fire event in a nuclear power plant

  • Jaiho Lee ;Byeongjun Kim;Yong Hun Jung;Sangkyu Lee;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1571-1584
    • /
    • 2023
  • In this study, a numerical analysis was performed as part of an international joint research project to reproduce a real cable tray fire that occurred in the heater bay area of the turbine building of a nuclear power plant. A sensitivity analysis was performed on various input parameters to derive results consistent with the sprinkler activation time obtained from the fire event analysis. For all sensitive parameters, the normalized sprinkler activation time correlated well with the power function of the normalized sprinkler height. A correlation equation was developed to identify the sprinkler activation time at any location when determining the slope or fire growth rate under the conditions assuming a linear or t-squared heat release rate (HRR) time curve. Various cable fire growth assumptions were used to determine which assumption was better to provide the prediction coincident with the information given from the fire event analysis in terms of the sprinkler activation time and total energy generated from cables damaged by fire. In the comprehensive analysis of all the sensitive parameters, the standard deviation of the input parameters increased as the sprinkler height decreased. Within the range of the sensitivity parameter values given in this study, when considering all sprinkler heights, the standard deviation of the cable model change was the largest and that of the overhang position change was the smallest.

Development of a Numerical Model for the Rapidly Increasing Heat Release Rate Period During Fires (Logistic function Curve, Inversed Logistic Function Curve) (화재시 열방출 급상승 구간의 수치모형 개발에 관한 연구 (로지스틱 함수 및 역함수 곡선))

  • Kim, Jong-Hee;Song, Jun-Ho;Kim, Gun-Woo;Kweon, Oh-Sang;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.20-27
    • /
    • 2019
  • In this study, a new function with higher accuracy for fire heat release rate prediction was developed. The 'αt2' curve, which is the major exponential function currently used for fire engineering calculations, must be improved to minimize the prediction gap that causes fire system engineering inefficiency and lower cost-effectiveness. The newly developed prediction function was designed to cover the initial fire stage that features rapid growth based on logistic function theory, which has a more logical background and graphical similarity compared to conventional exponential function methods for 'αt2'. The new function developed in this study showed apparently higher prediction accuracy over wider range of fire growth durations. With the progress of fire growth pattern studies, the results presented herein will contribute towards more effective fire protection engineering.

A Study on the Formations of Thermal Stratification of Furniture Fire (가구화재시 열적성층의 형성에 관한 연구)

  • 허만성
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.24-29
    • /
    • 1996
  • The objective of this research is to study on the formations of thermal stratification in a room in case of several furniture fires such as trashcan, chair, carpet, sofa, mattress and wardrobe as a fire starter in a residential room by performing the experimental studies. The uniformly distributed fire in case of carpet showed that the ignition and the initial growth period were relatively short while the fully developed period was considerably long. The concentrated fires such as the mattress and wardrobe showed that the ignitions and the initial growth periods were relatively long. When fire spread to only one direction, like the case for the trashcan with a regular shape, there was one peak of temperature profile, and for the irregular shaped furniture such as chair, sofa, mattress and wardrobe, there were two or more peaks. The interface heights for the furniture fires were around 1(m) mataining constant state. However, at the time of the maximum temperature, the interface height was lowered to 0.25(m)-0.75(m) from the floor

  • PDF

A Study on the Flame Growth Characteristics of Household Items(Refrigerator·Washing machine·Drawer·Sofa) (생활용품(냉장고·세탁기·장롱·소파)의 화재성장 특성 연구)

  • Park, Young Ju
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.45-51
    • /
    • 2015
  • This study was full-scale combustion test for flame growth characteristics and temperature characteristics analysis to predict the risk of household Items fire when fire occurs. Experimental results, Refrigerator flames were the highest measured in 15 min time, and Washing machine is between 20 ~ 30 min, Drawer is 5 min, Sofa was enabled up to the size of the flame 15 min. In addition, the maximum combustion temperature was found from the time 20 min ~ 25 min, Sofa is temperature was elevated up to $1190^{\circ}C$, Refrigerator is $1,162^{\circ}C$, Drawer is $822^{\circ}C$, Washing machine appeared to be rising up to $670^{\circ}C$. Therefore, in the case of the maximum temperature of combustion Sofa it showed relatively high.