공압서보시스템에 의한 미세 간극제어 시스템 설계 (Fine Gap Control Using Pneumatic Servo System)

  • 김동환;김영진;정대화
    • 한국정밀공학회지
    • /
    • 제19권12호
    • /
    • pp.45-56
    • /
    • 2002
  • A pneumatic servo system requiring a fine gap control in a photo-electric sensor which is used for a LCD array detection device is introduced. The gap controlled by the pneumatic servo system remains within around 50~80 ${\mu}{\textrm}{m}$, and the system possesses an effect to eliminate undesirable particles on the LCD plate by blowing air out. The air flow rate is initially controlled by a servo valve and expanded by a booster valve, thus the controlled air pressure contributes to maintaining an appropriate gap between the LCD plate and photo-electric sensor An air floating plate of two degrees of freedom is designed and fabricated, and a fine tilting motion control is also implemented by assigning different gap commands. The pressure control and direct gap control are proposed, and each performance is verified experimentally.

토지이용의 위험성 제어계획 -사용 밀도에 따른 기준치 설정의 접근방법- (Planning Controls for Land Use Safety)

  • 노삼규
    • 한국화재소방학회논문지
    • /
    • 제10권2호
    • /
    • pp.20-27
    • /
    • 1996
  • This paper discussed the limit of existing safety controls where the use of land around hazardous industry. There is a gap between engineering evaluation of acceptable criteria for loss reduction and risk exposure to the areas of high risk outside plants from the aspects of risk perception. The paper performed how land use safety could be designed between the density of uses with the duration of risk exposure by type of land use. It concluded the needs of multi-dimensional presentation for an appropriate risk controls on existing and future land use safety.

  • PDF

제연댐퍼 송풍량에 따른 피난 안전 구역 차압 및 연기 거동 특성 연구 (Study of Smoke Behavior and Differential Pressure in the Refuge Safety Area According to Damper Capacity of Smoke Control)

  • 이재빈;문주현;이성혁;유홍선
    • 한국화재소방학회논문지
    • /
    • 제25권4호
    • /
    • pp.103-109
    • /
    • 2011
  • 본 연구에서는 초고층 건축물 화재 시 피난 안전 구역이 있는 피난 층에서 화재실로부터 발생하는 연기의 거동을 파악하기 위하여 상용코드를 사용하여 수치해석을 하였다. 화재를 모사하기 위하여 10 MW의 발열량에 해당하는 온도와 속도를 이용하여 부력 plume을 적용하였으며 종 보존 방정식을 이용하여 화재 연기 거동을 예측하였다. 피난 안전 구역에 제연 댐퍼를 설치하여 급기 가압 제연 시스템을 적용하였으며 화재실 문이 열린 경우 25 $m^3/s$, 화재실과 부속실 문이 동시에 열린 경우 50 $m^3/s$의 제연 댐퍼송풍량은 화재 안전 기준 NFSC 501-A를 만족하며 충분히 제연이 가능하다는 것을 확인하였다. 부속실문이 열린 경우, 화재실의 문이 닫혀 있더라도 문과 벽 사이의 틈새 면적으로 연기가 피난 안전 구역으로 유입될 가능성이 있다. 또한, 50 $m^3/s$ 높은 송풍량으로 제연 중 화재실 문이 닫힐 경우 피난자가 화재실에 고립될 가능성을 확인하였다. 그러므로 피난자의 안전을 위해 제연 송풍량의 조절이 필요하며 본 연구에서는 피난 시나리오에 따른 적절한 송풍량을 제안한다.

농촌 소나무림에서 산불에 의한 식생변화와 유용미생물의 적용 (Vegetation Change after A Forest Fire in a Rural Japanese Red Pine Forest and Applications of Effective Microorganism)

  • 여지선;김기대
    • 한국환경복원기술학회지
    • /
    • 제11권4호
    • /
    • pp.46-56
    • /
    • 2008
  • This study examined the natural restoration of vegetation through monitoring of the development of a vegetation community from 2006 through 2007 after a forest fire. Approximately 5,000 $m^2$ in a forest near Topyeon-ri, Kangnae-myeon, Chungcheongbuk-do with Japanese red pine (Pinus densiflora) forest and its floor vegetation had been completely burned by a fire in April 2005. This area and another nearby Japanese red pine forest were selected as the experiment site and the control site, respectively. Vegetation survey was conducted at the experiment site and the control site. A seed bank experiment was carried out in the greenhouse to examine underground vegetation. Effective microorganism(EM) was applied to the seed bank experiment to estimate its effects on the direction of ecological succession. According to the results, a total of 36 plant species including shrub and herbaceous species were discovered in the experiment site. Quercus serrata, Lespedeza cyrtobotrya, and Castanea crenata, Rubus crataegifolius, Oplismenus undulatifolius, and Carex lanceolata were among the most abundant species. Biomass in the experiment site reached 2.4 times biomass than those in the control site, indicating the productivities of shrub and herbaceous layers are better in the experiment site. According to the result of the soil seed bank experiment of the experiment site, a total of 182 plants of 14 species were recorded. In addition, a total of 13 plants of 2 species were found from soil seed bank of the experiment site applied by EM. If EM is applied to the burned site, it will control the budding of herbaceous plants, creating the gap between herbaceous plants. This loss of competition is expected to help the restoration of trees in the burned area.

방화문의 누설틈새 계산 및 연돌효과 분석 (The Leakage Crack Calculation of the Fire Door and the Stack Effect Analysis)

  • 김일영;권창희
    • 한국화재소방학회논문지
    • /
    • 제27권2호
    • /
    • pp.46-53
    • /
    • 2013
  • 건축의 환경이 변하면 그에 따른 설계기준도 변하여야 한다. 방화문의 시험기준이 2005년 7월 27일 차연성 시험이 적용되면서 문틈이 기밀한 구조로 바뀌었다. 그러나 국가화재안전기준은 영국의 자료를 인용한 과거의 문틈규정을 적용함으로서 현실과 설계 규정의 차이가 오차나 안전율 이상으로 과도하다. 설계와 현실의 차이로 인하여 발생하는 결과 및 현상을 분석하고 개정되어야 할 국가화재안전기준의 누설틈새면적 계산법을 제시하고 연돌효과로 인한 방연풍속의 차이를 분석하였으며 생활패턴 및 피난패턴을 반영한 공동주택의 방연풍속 측정법에 대해 고찰하고 합리적인 측정법을 제시하였다.

Planning for Safely Control on Hazardous Material Distribution Depot.

  • Roh, S.K.;Jun, S.W.;Kang, T.H.;Seo, Y.M.
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.260-268
    • /
    • 1997
  • The safety of LPG vessel storage has been simply designed and controled with blast wave barrier structure concept regardless of its quantity or hazardous situation. The limit of regal controls on LPG vessel storage need to be identified in terms of safety buffer distance from LPG explosion. The level of overpressure effect and heat radiation In the safety structure and neighbouring human activity required to be estimated to find the gap between existing controls on such storage. To this content the paper discuss the issues on the approach In the blast wave barrier and safety separation distances.

  • PDF

LPG 판매업소의 위험성 제어계획 (Planning for Safety Control on LPG Distribution Depot)

  • 노삼규;전성우;강태희;서영민
    • 한국화재소방학회논문지
    • /
    • 제12권4호
    • /
    • pp.21-30
    • /
    • 1998
  • LPG 판매업소의 용기보관창고는 보관량이나 위해 상황을 충분히 고려하지 않은 상태로 단순히 방폭벽 구조에 의한 안전규제에 의존해 왔다 따라서 LPG폭발로 인한 보관창고 의 안전규정은 안전완충거리를 충분히 확보하고 있는지 확인할 필요가 있다. 기존의 안전 규제는 그러한 보관창고로부터 사고시 인근에 위치한 구조물과 연간 활동에 미치는 잠재 적 초과압력이나 방출열의 정도를 고려하고 있는지 그 확인이 요구된다. 본 연구는 P PHAST와 IAEA의 위험성 평가와 우선 순위 선정수법, 일본의 LPG 판매소 안전규정 등 을 통하여 안전거리를 산출하였다. 이 결과에 의하면 기존의 LPG판매소의 방폭벽은 추가 적인 안전거리가 요구된다.

  • PDF

응급구조(학)과 대학생의 코로나바이러스감염증-19(COVID-19)에 대한 지식 및 태도와 감염관리 수행도 간의 관련성 연구 (A Study on the Relation between Knowledge and Attitude on Coronavirus Disease-19 (COVID-19) and Infection Control Performance of Paramedic students)

  • 박대성;김갑선;이만진;김예림
    • 미래기술융합논문지
    • /
    • 제2권3호
    • /
    • pp.25-32
    • /
    • 2023
  • 본 연구는 응급구조(학)과 대학생을 대상으로 코로나19에 대한 지식 및 태도와 감염관리 수행도 간의 관련성을 알아보기 위해 시행하였다. 연구 대상은 전라남북도, 광주광역시에 소재한 3-4년제 응급구조(학)과에 재학 중인 대학생 154명이고, 수집된 자료는 SPSS/WIN 16.0을 이용하여 빈도와 백분율, 합(Sum), 평균 및 표준편차, t-test, ANOVA(Scheffe), Pearson's Correlation Coefficient, Multiple Linear Regression으로 분석하였다. 응급구조(학)과 대학생들의 감염관리 수행도에 코로나19에 대한 태도와 지식 순으로 영향을 미쳤다. 따라서 응급구조(학)과 대학생들의 감염관리 수행도를 높이기 위해 코로나19에 대한 지식 및 태도를 향상시킬 수 있는 정규 또는 비정규 교육과정, 다학제적 교육과정 개발 및 적용이 필요하다.

GIS를 이용한 화재진압 취약성 지도 제작 - 대구광역시 달서구를 사례로 - (Producing Firefighting Vulnerability Maps Using GIS - A Case Study of Dalseo-gu, Daegu -)

  • 김성재;최갑용;장은미;송완영
    • 한국지리정보학회지
    • /
    • 제18권3호
    • /
    • pp.11-20
    • /
    • 2015
  • 매년 발생하고 있는 화재사고는 많은 재산과 인명의 피해를 안겨주고 있다. 이러한 피해를 최소화하고 적절한 사고대응을 하기 위하여 많은 시간과 비용을 투자해 오고 있으며, 최근 들어서는 공간정보 기술이 발달함에 따라 소방분야에서도 GIS(Geographic Information System)를 활용한 화재진압 관련 연구들이 많이 수행되어져 오고 있다. 그러나 대부분의 연구들이 소방 관련 요소들에 대한 개별적인 분석만 이루어지고 있을 뿐 소방 활동의 주요 임무인 화재진압 활동 취약요소들에 대한 종합적 분석 연구는 미진한 실정이다. 본 연구에서는 원활한 화재진압 활동을 함에 있어 방해되는 요소들을 파악 및 분석하고, 이와 관련된 데이터들을 수집하여 GIS DB화를 수행하였다. 이를 기반으로 GIS 중첩분석을 수행하여 화재진압 취약성 지도를 제작하였다. 본 연구를 통하여 화재진압 활동 저해 요소들에 대한 정량적 분석이 가능함으로써 골든타임 확보를 위한 화재진압 운영계획등과 같이 소방관련 종사자들에게 합리적인 의사결정을 지원할 수 있을 것으로 판단된다.