• Title/Summary/Keyword: fire equipments

Search Result 120, Processing Time 0.024 seconds

The Ergonomic Layout of Ship's Bridge Panels using the Mathematical Programming (수리모형을 이용한 선박 항해기기 패널의 인간공학적 배치)

  • Jang, Jun-Hyuk;Kim, Hong-Tae;Sim, Joung-Hoon;Lee, Dong-Choon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.251-257
    • /
    • 2011
  • When designing a ship, ergonomic considerations are crucial when minimizing a navigator's fatigue due to the burden of work, and to appropriately operate the navigational equipment for each given situation by helping the operator to understand the surroundings as well as the physical functions of the ship. However, insufficient consideration of ergonomic elements in the actual design of ship Bridges is lowering the performance of safe navigation and allows for the possibility of operation or readout errors. Consequently, these errors lead to an increase in maritime accidents. Therefore, this study conducted a usability evaluation on the importance of and the usage frequency of navigational equipment, their influence on actual navigation, and the possibility of error upon operation or readout between training ship officers, to derive an optimized layout that includes the consideration of ergonomic factors for on-Bridge navigational equipment, which are currently arranged differently according to their type or size. The optimized layout of on-Bridge navigational equipment was carried out based on the evaluation results, using the Lingo program. Through the process of optimization, revised layouts of on-Bridge navigational equipments(control and display device) were suggested, considering emergency situations(ship collision, stranding, fire and explosion, sinking, etc.) during navigation.

Design and Implementation of LoRa-based Emergency Exit Guide System (LoRa 기반 피난 유도 체계의 설계 및 구현)

  • Shin, Jaejun;Eun, Seongbae;So, Sun-Sup;Kim, Byungho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.4
    • /
    • pp.569-574
    • /
    • 2018
  • This paper proposes and implements a LoRa-based emergency exit guide system which can direct the optimal refuge path accounting for the real state of the fires. Each 4-way emergency exit guide sign presents a right direction through one of four LED signs toward the possible exit dynamically calculated by the shortest path algorithm. We constructed a simulation environment with 8 spots of the emergency exit guide signs and 2 exits, which can simulate variant cases of fire accidents, and showed that the proposed algorithm can presents the right guidance for each emergency exit guide sign. We also evaluated the performances of LoRa-based wireless communications using a self developed communication module in the various indoor and outdoor environments. The proposed system can be applied to small and medium sized buildings as well as larger ones in terms of cost efficiency, in which there's no needs to invest for the complex equipments except only sensors and emergency exit guide signs.

Development of M2M-based Underground Space (subway) Disaster Response Network and EL Display Integrated Board (M2M기반 지하공간(지하철) 재난대응 네트워크 및 EL 디스플레이 통합 보드 개발)

  • Park, Miyun;Kwon, Segon;Park, EunChurn;Lee, Jeonhun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.422-441
    • /
    • 2017
  • Notifying emergency evacuation methods, accurate disaster location and evacuation route guidance can be very active alternatives to quickly minimize evacuation and casualties in disaster situation in the development of subway disaster prevention detection system that detects the disaster signs at the subway station early on the basis of Internet of things and leads passengers to evacuate. It's not easy to ensure perfect functioning of fire fighting facilities and equipments due to underground space structure with narrow exits. Therefore, we developed disaster provision EL Display integrated board that can induce the most efficient evacuation and the field experiment was conducted to examine the practical application in this study. Especially the applicability was verified by field application test because there is no case in which EL panels are used to evacuate disasters.

A Study on the Institute Warranties in the Institute Time Clauses-Hulls 1/10/83 (선박보험약관상 협회항행제한담보약관(協會航行制限擔保約款)에 관한 연구)

  • Park, Sang-Kab;Kim, Jong-Rak;Shin, Young-Ran
    • Journal of Navigation and Port Research
    • /
    • v.36 no.5
    • /
    • pp.329-338
    • /
    • 2012
  • The Institute Time Clauses-Hulls 1/10/83 has been using widely with attachment and/or endorsement of the Institute Warranties 1/7/76 stipulating vessel's trading limits. Taking into consideration of several changes and renewals on the contents of the Institute Time Clauses-Hulls for clarifying the clauses themselves with development on technology of vessel's construction and navigational equipments up to the present, the clauses on the Institute Warranties 1/7/76 should have been changed and/or renewed. Moreover, the insured still has been burdening additional premium in vessel's navigating and / or calling to the areas stipulated in the Institute Warranties 1/7/76 regardless of any changes of marine business environments. Thus, this study aims to analyze the Institute Warranties 1/7/76 as well as to suggest a reasonable level of additional premium for breach of Institute warranties through not only a comparative analysis between the Institute Warranties clauses and those of the corresponding Institute Warranties using in the Japanese Fire and Marine Insurance companies but also consideration of current circumstances on changes in climatic conditions, vessel design, navigation and communication requirements and capabilities.

Study on the method of safety diagnosis of electrical equipments using fuzzy algorithm (퍼지알고리즘을 이용한 전기전자기기의 안전진단방법에 대한 연구)

  • Lee, Jae-Cheol
    • Journal of Digital Convergence
    • /
    • v.16 no.7
    • /
    • pp.223-229
    • /
    • 2018
  • Recently, the necessity of safety diagnosis of electrical devices has been increasing as the fire caused by electric devices has increased rapidly. This study is concerned with the safety diagnosis of electric equipment using intelligent Fuzzy technology. It is used as a diagnostic input for the multiple electrical safety factors such as the use current, cumulative use time, deterioration and arc characteristics inherent to the equipment. In order to extract these information in real time, a device composed of various sensor circuits, DSP signal processing, and communication circuit is implemented. The fuzzy logic algorithm using the Gaussian function for each information is designed and compiled to be implemented on a small DSP board. The fuzzy logic receives the four diagnostic information, deduces it by the fuzzy engine, and outputs the overall safety status of the device as a 100-step analog fuzzy value familiar to human sensibility. By experiments of a device that combines hardware and fuzzy algorithm implemented in this study, it is verified that it can be implemented in a small DSP board with human-friendly fuzzy value, diagnosing real-time safety conditions during operation of electric equipment. In the future, we expect to be able to study more intelligent diagnostic systems based on artificial intelligent with AI dedicated Micom.

A Study on Lawsuit Cases and Measures of Emergency Medical Service (응급의료서비스 중 발생되는 소송사례와 대책 연구)

  • Kwon, Hay-Ran
    • The Korean Journal of Emergency Medical Services
    • /
    • v.13 no.3
    • /
    • pp.77-90
    • /
    • 2009
  • Civil complaints and lawsuits filed in the process of providing emergency medical service include fall accident on the way of carrying the patient, transfer consent, refusal and rejection of rescue request, range and behavior restriction of emergency medical technicians, false registry of logbook, neglect of duty and emergency patient, and violation of traffic laws on the way of dispatch to the scene of accident. This study suggested the measures by cases as follows. 1. The accidents on the way of carrying a patient could be divided into fall of patient and fall by paramedic's mistake. In the former case, damages caused by the ambulance's shaking must be notified to the patient and guardian and recommended to fasten seat belt, in the latter case, the plan of patient's posture, route of transport, rescue and equipments should be comfirmed before fixing the patient. 2. Transfer consent must be made as implied when the patient is unconscious under delusion and was not able to consent physically, and paramedic must take an action by his judgment and record details of services on logbook. 3. When a patient refused to transfer, get 'confirmation of transfer refusal' and inform him of refusal. Paramedic should receive the signature. In addition, in case of refusal, transfer request should be made after hearing doctor's opinion and it should be notified to transfer request and superintendent of fire station after making 'confirmation of transfer refusal'. 4. Emergency medical technicians should perform their duties within the range of services prescribed by Article 41 of Law of Emergency Medical Service and Article 33 of Its Enforcement Regulations and shall not make announcement of death. In case of reporting the death to guardian, it is desirable to use record data like ECG results. 5. The best way to have protection from legal problems is making and keeping the exact records of accident and patient. Paramedic should not mention his subjective opinion about the accident-related matter. He must record correctly and keep the original medical records. 6. As emergency medical technicians are responsible for taking care of emergency patients, they must contact a briefing room when they meet a difficult situation suddenly due to vehicle stop or treatment of other patients and then must have support from neighboring hospital and other safety centers. 7. Since the ambulance operator is responsible for safety and careful driving of ambulance, he must be careful when he violates traffic regulations unavoidably. The operator should drive slowly below 10km/h at an intersection and pass it after getting way from general vehicles driving from all directions.

  • PDF

Performance Ability after CPR Education of the ground workers in an airport (공항 지상 근무자의 심폐소생술 수행능력)

  • Shin, Ji-Hoon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.13 no.3
    • /
    • pp.29-40
    • /
    • 2009
  • Objective : This study is an experimental study which is designed to examine the differences between knowledge and self-confidence before and after theory education(CPR PPT material) based on guidelines of CPR and emergency cardiac treatment of American Heart Association(AHA, 2005) and video self-instruction program for the general public by Korean Association of Cardiopulmonary Resuscitation(KACPR), trace CPR performance ability after CPR and AED education and investigate the accuracy of artificial respiration and chest compression, and know the difference in CPR performance abilities including AED. Methods : Subjects of this study include ground crews and staffs at M airport in G province equipped with emergency equipments for CPR according to Art. 47, Sec. 2 of Emergency Medical Law, airport police, rent-a-cops, security guard, quarantine officer, custom officer, and communication, electricity, civil engineering, facility management staff, airport fire fighting staff, air mechanic, traffic controller, and airport management team among airport facility management staffs. They were given explanation of necessity of research and 147 of 220 subjects who gave consent to this research but 73 who were absent from survey were excluded were used as subjects of this study. of 147 subjects, there were 102 men and 45 women. Results : 1) Knowledge score of CPR was $6.18{\pm}0.87$ before instruction and it was increased to $15.12{\pm}1.78$ after instruction, and there was statistically significant difference. 2) Self-confidence score in CPR was $3.16{\pm}0.96$ before instruction and it was increased to $7.05{\pm}0.75$ after instruction, and there was statistically significant difference. 3) Total average score in CPR performance ability after instruction was 7.46 out of 9, performance ability was highest in confirmation of response as 144(97.95%), follwed by request of help as 140(95.25%) and confirmation of respiration as 135(91.83%), and lowest in performing artificial respiration twice(gross elevation of chest) as 97(65.98%). Accuracy of artificial respiration(%) was $28.60{\pm}16.88$ and that of chest compression(%) was $73.10{\pm}22.16$. 4) Performance ability of AED after instruction showed proper performance in power on by 141(95.91%) and attaching pad by 135(91.83%), hand-off for analyzing rhythm showed 'accuracy' in 115(78.23%) and 'non-performance' in 32(21.77%), delivery of shock and hand-off confirmation showed 'accuracy' in 109(74.14%) and 'inaccuracy' in 38(25.86%), and beginning chest compression immediately after AED was done by 105(71.42%).

  • PDF

A Study on the Legislation for the Commercial and Civil Unmanned Aircraft System Operation (국내 상업용 민간 무인항공기 운용을 위한 법제화 고찰)

  • Kim, Jong-Bok
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.28 no.1
    • /
    • pp.3-54
    • /
    • 2013
  • Nowadays, major advanced countries in aviation technology are putting their effort to develop commercial and civil Unmanned Aircraft System(UAS) due to its highly promising market demand in the future. The market scale of commercial and civil UAS is expected to increase up to approximately 8.8 billon U.S. dollars by the year 2020. The usage of commercial and civil UAS covers various areas such as remote sensing, relaying communications, pollution monitoring, fire detection, aerial reconnaissance and photography, coastline monitoring, traffic monitoring and control, disaster control, search and rescue, etc. With the introduction of UAS, changes need to be made on current Air Traffic Management Systems which are focused mainly manned aircrafts to support the operation of UAS. Accordingly, the legislation for the UAS operation should be followed. Currently, ICAO's Unmanned Aircraft System Study Group(UASSG) is leading the standardization process of legislation for UAS operation internationally. However, some advanced countries such as United States, United Kingdom, Australia have adopted its own legislation. Among these countries, United States is most forth going with President Obama signing a bill to integrate UAS into U.S. national airspace by 2015. In case of Korea, legislation for the unmanned aircraft system is just in the beginning stage. There are no regulations regarding the operation of unmanned aircraft in Korea's domestic aviation law except some clauses regarding definition and permission of the unmanned aircraft flight. However, the unmanned aircrafts are currently being used in military and under development for commercial use. In addition, the Ministry of Land, Infrastructure and Transport has a ambitious plan to develop commercial and civil UAS as Korea's most competitive area in aircraft production and export. Thus, Korea is in need of the legislation for the UAS operation domestically. In this regards, I personally think that Korea's domestic legislation for UAS operation will be enacted focusing on following 12 areas : (1)use of airspace, (2)licenses of personnel, (3)certification of airworthiness, (4)definition, (5)classification, (6)equipments and documents, (7)communication, (8)rules of air, (9)training, (10)security, (11)insurance, (12)others. Im parallel with enacting domestic legislation, korea should contribute to the development of international standards for UAS operation by actively participating ICAO's UASSG.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009 (설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo Young;Choi, Jong-Min;Baik, Yong-Kyu;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

Recent Progress in Air Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 (공기조화, 냉동 분야의 최근 연구 동향: 2006년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.427-446
    • /
    • 2008
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 has been accomplished. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro heat exchanger and siphon cooling device using nano-fluid. Traditional CFD and flow visualization methods were still popular and widely used in research and development. Studies about diffusers and compressors were performed in fluid machinery. Characteristics of flow and heat transfer and piping optimization were studied in piping systems. (2) The papers on heat transfer have been categorized into heat transfer characteristics, heat exchangers, heat pipes, and two-phase heat transfer. The topics on heat transfer characteristics in general include thermal transport in a cryo-chamber, a LCD panel, a dryer, and heat generating electronics. Heat exchangers investigated include pin-tube type, plate type, ventilation air-to-air type, and heat transfer enhancing tubes. The research on a reversible loop heat pipe, the influence of NCG charging mass on heat transport capacity, and the chilling start-up characteristics in a heat pipe were reported. In two-phase heat transfer area, the studies on frost growth, ice slurry formation and liquid spray cooling were presented. The studies on the boiling of R-290 and the application of carbon nanotubes to enhance boiling were noticeable in this research area. (3) Many studies on refrigeration and air conditioning systems were presented on the practical issues of the performance and reliability enhancement. The air conditioning system with multi indoor units caught attention in several research works. The issues on the refrigerant charge and the control algorithm were treated. The systems with alternative refrigerants were also studied. Carbon dioxide, hydrocarbons and their mixtures were considered and the heat transfer correlations were proposed. (4) Due to high oil prices, energy consumption have been attentioned in mechanical building systems. Research works have been reviewed in this field by grouping into the research on heat and cold sources, air conditioning and cleaning research, ventilation and fire research including tunnel ventilation, and piping system research. The papers involve the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies on indoor air quality took a great portion in the field of building environments. Various other subjects such as indoor thermal comfort were also investigated through computer simulation, case study, and field experiment. Studies on energy include not only optimization study and economic analysis of building equipments but also usability of renewable energy in geothermal and solar systems.