• 제목/요약/키워드: fire control system

검색결과 731건 처리시간 0.023초

Development of K-Maryblyt for Fire Blight Control in Apple and Pear Trees in Korea

  • Mun-Il Ahn;Hyeon-Ji Yang;Sung-Chul Yun
    • The Plant Pathology Journal
    • /
    • 제40권3호
    • /
    • pp.290-298
    • /
    • 2024
  • K-Maryblyt has been developed for the effective control of secondary fire blight infections on blossoms and the elimination of primary inoculum sources from cankers and newly emerged shoots early in the season for both apple and pear trees. This model facilitates the precise determination of the blossom infection timing and identification of primary inoculum sources, akin to Maryblyt, predicting flower infections and the appearance of symptoms on various plant parts, including cankers, blossoms, and shoots. Nevertheless, K-Maryblyt has undergone significant improvements: Integration of Phenology Models for both apple and pear trees, Adoption of observed or predicted hourly temperatures for Epiphytic Infection Potential (EIP) calculation, incorporation of adjusted equations resulting in reduced mean error with 10.08 degree-hours (DH) for apple and 9.28 DH for pear, introduction of a relative humidity variable for pear EIP calculation, and adaptation of modified degree-day calculation methods for expected symptoms. Since the transition to a model-based control policy in 2022, the system has disseminated 158,440 messages related to blossom control and symptom prediction to farmers and professional managers in its inaugural year. Furthermore, the system has been refined to include control messages that account for the mechanism of action of pesticides distributed to farmers in specific counties, considering flower opening conditions and weather suitability for spraying. Operating as a pivotal module within the Fire Blight Forecasting Information System (FBcastS), K-Maryblyt plays a crucial role in providing essential fire blight information to farmers, professional managers, and policymakers.

지하공간에 대한 제연설비 성능기준의 적정성 고찰(I) (A Study on Appropriateness of Performance Criteria of Smoke Control System for Underground Spaces (I))

  • 안찬솔;김홍열;유용호;전규엽
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.103-106
    • /
    • 2008
  • This study is intended to evaluate the characteristics of smoke spreading and the appropriateness of evacuation time extended by operation of smoke control system during fire within the underground space of the building structured in compliance with the smoke control system performance criteria from the local fire safety standard, which has been currently applied to the buildings in Korea. Using the heat release per unit weight of the combustibles, a numerical analysis both in case of smoke control system in operation and the system not in operation was carried out at the several different shopping malls. From the viewpoint of securing the evacuation time, the results were compared in an attempt to assess the appropriateness of the fire safety criteria.

  • PDF

큰 개구부가 있는 공간의 화재와 제연의 대와류모사 (Large Eddy Simulation of Fire and Smoke Control in a Compartment with Large Openings)

  • 박외철
    • 한국화재소방학회논문지
    • /
    • 제17권3호
    • /
    • pp.7-12
    • /
    • 2003
  • 지하철 역과 같이 대형 개구부가 있는 공간의 화재와 제연을 조사하기 위해, 지하철 역과 유사한 구조의 4 m ${\times}$ 1 m ${\times}$ 1.5m 크기의 공간 내 50 kW의 폴리우레탄 화재에 대한 수치모사를 수행하였다. 대와류모사를 난류모델로 사용하고, 혼합분율 연소모델과 복사 유한체적법을 사용하였다. 화재 발생 후 5초부터 급배기방식과 급기방식, 배기방식의 세가지 기계 제연방식이 각각 작동했을 때 제연방식에 따른 승강장과 출입통로의 공기온도와 연기이동을 비교하였다. 제연방식 가운데 급배기방식의 제연성능이 가장 좋고 안전한 것으로 나타났다. 그러나 지하철 역에 사용되고 있는 급기방식은 급기구를 통해 공급된 공기가 고온의 연기와 혼합됨으로써 제연성능이 오히려 자연제연방식보다 불량하므로 지하철 역과 같은 구조에서는 적합하지 않음을 확인하였다.

제연구역 출입문의 차압 및 개방력 측정기준의 실효성 분석에 관한 연구 (Study on the Analysis of Differential Pressure of the Access Door for a Smoke Control Zone and the Effectiveness of the Measurement Criteria of its Opening Force)

  • 이재오;최충석
    • 한국화재소방학회논문지
    • /
    • 제26권4호
    • /
    • pp.24-30
    • /
    • 2012
  • 본 연구에서는 화재실과 인접부 제연구역의 차압 및 방화문의 개방력을 측정할 때의 문제점을 분석하고, 객관적인 방법에 의해 측정된 실측값을 제시하는데 있다. NFSC 501A의 제연설비 가동 시 출입문의 개방에 필요한 힘은 110 N 이하로 규정하고 있다. 제연설비가 설치된 공간에서 제연설비가 작동하지 않을 때는 KS F 2805의 시험방법에 의해서 개방력의 측정이 가능하지만 제연설비가 작동되었을 때는 화재실과 제연실의 차압에 의해 발생되는 추가적인 힘이 필요하므로 기준에서 제시하는 시험방법은 신뢰성이 부족함을 알 수 있다. 제연설비 가동 전 완전히 폐쇄된 상태의 개방력은 아날로그측정기($F_a$) 27.8 N, 디지털측정기($F_d$) 27.4 N을 각각 나타냈다. 그리고 문이 $5^{\circ}$ 개방된 상태의 개방력 $F_a$는 33 N, $F_d$는 33.6 N을 나타냈다. 제연설비가 작동되고 완전히 폐쇄된 상태의 개방력 $F_a$는 45.3 N, $F_d$는 46.9 N을 나타냈고, 문이 $5^{\circ}$ 개방된 상태의 개방력 $F_a$는 77.6 N, $F_d$는 76.0 N 등으로 확인되었다. 따라서 현재의 KS F 2805에서 제시하고 있는 기준과 상이하므로 적절한 기준의 검토가 요구된다.

A Study on the Safe Position from the Local Fire in the Ship's Engine Rooms

  • Kim, Mann-Eun;Lee, Kyoung-Woo;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권3호
    • /
    • pp.446-454
    • /
    • 2008
  • Control devices for fire safety systems located in a engine room are to be arranged at a safe position which is easily accessible during a fire. To develop an interpretation for the safe position in engine rooms, calculation and experiments are carried out to determine a correlation between radiant heat and distance from fire in this paper. On the basis of results of this research, the control devices for a main engine are to be installed in the behind side of an obstruction to reduce radiant heat from the fire of the main engine. In case of other control devices, they are also to be provided in the same manner of control devices for the main engine or are to be placed with 5 meters far from fire hazards.

발사체 열제어/화재안전 시스템 설계 및 시험 (Design and Test of Thermal Control and Fire Safety System for Space Launch Vehicle)

  • 고주용;오택현;이준호
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.1006-1010
    • /
    • 2017
  • 본 논문은 발사체의 지상대기 및 운용 중 격실 내부의 열제어 및 화재/폭발 방지를 위해서 적용되는 열제어/화재안전계에 대한 설계 및 시험에 대해서 기술한다. 고려된 시스템은 한국형발사체 개발의 일환으로 진행되고 있는 시험발사체의 열제어/화재안전 시스템으로 이 시스템은 나로호의 경험을 토대로 고압 시스템을 적용한다. 고압 및 저압 시스템의 선정은 발사대의 가스공급 설비 및 발사체의 특성을 고려해서 선정하며 이에 따라 시스템의 구성도 달라진다. 결과적으로 개발된 시스템은 시험을 통해서 초기의 설계 조건을 만족하는 결과를 얻을 수 있음이 확인되었으며, 이러한 시스템은 한국형발사체의 개발에 그대로 확장되어 적용될 예정이다.

  • PDF

규칙 및 클러스터링에 의한 사례기반 추론을 이용한 지능형 선박 화재진압통제시스템의 성능 개선 (Performance Improvement of the Intelligent System for the Fire Fighting Control using Rule-based and Case-based Reasoning by Clustering in a Ship)

  • 현우석
    • 정보처리학회논문지B
    • /
    • 제9B권3호
    • /
    • pp.263-270
    • /
    • 2002
  • 현재가지 개발된 화재진압통제 지능시스템들은 대부분 규칙기반 시스템이다. 실제로 화재를 탐지하는데 필요한 지식은 정형화된 규칙만으로 표현하기 어렵다. 또한 시스템의 성능 향상을 위해서 지속적인 규칙들의 수정 및 추가가 이루어져야 하며, 특히 예외적인 상황에서의 화재 발생 탐지시 문제점을 지니고 있다. 이러한 문제점들을 개선하기 위한 규칙 및 사례기반 추론을 이용한 하이브리드 화재진압통제 지능시스템 (H-FFIS)은 규칙기반 시스템보다 화재탐지율은 향상시켰으나, 수행시간이 증가되었다. 본 연구에서는 기존의 H-FFIS의 단점을 보완하기 위하여 규칙 및 클러스터링에 의한 사례기반 추론을 이용한 개선된 선박 화재진압통제 지능시스템(A-FFIS)을 제안한다. 제안하는 시스템은 기존의 H-FFIS와 비교해 볼 때, 수행시간을 감소시키면서 정확성을 향상시키는 결과를 얻었다.

대구 지하철역 제연의 문제점과 대책 I. 제연방식 (A Numerical Simulation of Smoke Control in Daegu Subway Stations I. Smoke Control System)

    • 한국화재소방학회논문지
    • /
    • 제17권4호
    • /
    • pp.98-104
    • /
    • 2003
  • 대구 지하철역 제연의 문제점과 그 대책을 조사하기위해 지하철역 승강장 계단 주위 10 m${\times}$3 m${\times}$5.4 m 의 공간에서의 제연을 FDS로 모사하였다. 200 ㎾의 폴리우레탄 화재와 각 급기구와 배기구의 공기유량 0.9 ㎥/s에 대한 급기방식의 제연성능을 온도와 연기입자의 분포로 조사한 결과, 급기방식은 제연효과가 거의 없어 연기를 신속하게 배출하지 못함을 알 수 있었다. 또 세가지 기계제연방식 중에서 배기방식의 제연성능이 가장 우수하므로, 급기방식을 단순히 배기방식으로 전환함으로써 제연성능을 대폭 개선할 수 있음을 확인하였다.

Performance Evaluation of a BACnet-based Fire Detection and Monitoring System for use in Buildings

  • Song Won-Seok;Hong Seung-Ho
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권1호
    • /
    • pp.70-76
    • /
    • 2006
  • The objective of this paper is to propose a reference model of a fire detection and monitoring system using MS/TP protocol. The reference model is designed to satisfy the requirements of response time and flexibility. The reference model is operated on the basis of BACnet, a standard communication protocol for building automation systems. Validity of the reference model was examined using a simulation model. This study also evaluated the performance of the BACnet-based fire detection and monitoring system in terms of network-induced delay. Simulation results show that the reference model satisfies the requirements of the fire detection and monitoring system.

부속실 급기가압제연시 차압변화에 관한 실험적 연구 (An Experimental Study on the Pressure Differentials during the Pressurized Air Supply to the Elevator Lobby)

  • 김범규;박용환;김홍식
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.110-119
    • /
    • 2009
  • A fire should be accompanied by the heat and smoke. However, smoke is considered main cause of heavy casualties. Smoke easily spreads away from the fire area to remote space and cause mortal wound for the resident. A technical way effectively protecting the life and property from the smoke is the smoke control system of the building. Pressurized air supply system can be considered to prevent the refuge area from the smoke infiltration that evacuate residents via evacuation route for life safety. This paper is related with performance estimation and the effectiveness of the pressurized air supply system through experiments.

  • PDF