• 제목/요약/키워드: finger skin temperature

검색결과 28건 처리시간 0.019초

전신경화증으로 유발된 속발성 레이노증후군 호전 1례 (A Case of Raynaud's Syndrome Modified by Secondary Systemic Sclerosis)

  • 장영우;김정윤;김혜경;이기언;임승환
    • 한방안이비인후피부과학회지
    • /
    • 제31권4호
    • /
    • pp.108-116
    • /
    • 2018
  • Objectives : A Report on the Improvement of korean medical treatment of Secondary Raynaud's Syndrome Caused by Systemic Sclerosis. Methods : We treated a Secondary Raynaud's syndrome 59-year-old woman with herbal medicine and acupuncture treatment for 3 months. The evaluation of treatment was confirmed by photographs before and after treatment, VAS, and palm skin temperature. Results : After treatment, the color of both fingernails and finger skins recovered from white to purplish red, and Raynaud phenomenon and palm flaring were decreased. VAS decreased from 8 to 2 and palm skin temperature increased by left hand 1.4 degrees right hand 1.2 degrees. Conclusions : It was shown that korean medical treatment was effective in the conservative treatment of Secondary Raynaud's syndrome caused by systemic sclerosis.

인지과제 수행시 배경 소음의 크기에 따른 생리적 반응차 (The role background noise intensity on Physiological activity during performance of mental task)

  • 손진훈;;민윤기;이경화;최상섭
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1999년도 학술발표대회 논문집 제18권 1호
    • /
    • pp.269-273
    • /
    • 1999
  • Combination of mental stress task with noise background is a traditional tool employed in psychophysiology. However, intensity of background noise is a factor affecting both performance on test and psychophysiological responses associated with stress evoked by mental load in noisy environment. In the current study on 7 subjects we analyzed the influence of white noise (WN) intensity (55, 70, and 85 dB[A] ) on psychophysiological responses during word recognition test performed on noise background. There were recorded following physiological variables: electrodermal activity (EDA) , namely, skin conductance level (SCL), skin conductance response (SCR) amplitude (SCR-A), rise time and total number of SCRs (N-SCR); cardiovascular activity, e.g., heart rate (HR), respiratory sinus arrhythmia (RSA) index, pulse transit time (PTT), finger pulse volume (PV), skin temperature (SKT) and respiratory activity, such as respiration rate (RESP-R) and inspiration wane amplitude (RESP-A) during baseline resting state and 40 s long performance on 3 similar Korean word recognition tests with different WN intensity (55, 70, and 85 dB). Electrodermal responses (SCR-A, SCL, N-SCR) demonstrated gradual increment with increased intensity of noise, and this increase of response magnitude with higher intensity of noise was typical also for r skin temperature (phasic SKT decrease) and pulse volume (phasic and tonic PV decrease). However, some cardiovascular and respiratory responses did not exhibit same tendency of gradual increase of reactivity , namely HR, as well as RESP-R and RESP-A showed decrement of response magnitudes. Important finding in terms of cardiovascular reactivity was that 55 and 70dB evoked similar profiles, while 85dB WN resulted in significantly different profile of reactions, suggesting that there exists a threshold level after which intensive auditory stimulation elicits psychophyslological responses pattern of different quality. There are discussed potential autonomic mechanism involved in mediation of observed physiological responses.

  • PDF

원적외선 방사 기능 실내복 착용이 인체 피부혈류량, 온열 심리 및 온열 생리 기능에 미치는 영향 (Influences of Wearing Far-infrared Indoor Clothing on Skin Blood Flow, Perceptual and Thermal Responses)

  • 백윤정;서원지;김형찬;이주영
    • 한국의류학회지
    • /
    • 제44권2호
    • /
    • pp.342-353
    • /
    • 2020
  • The purpose of this study was to evaluate far-infrared clothing (FIR condition) with non-far-infrared clothing (Control condition) to assess the effects of FIR on thermo-physiological responses. Eight young healthy males (23.0±2.3 yr, 176.5±3.7 cm, and 69.0±4.3 kg) participated in this experimental trial, which consisted of a 20 min rest followed by a 40 min walk (4.0 km·hr-1) and a 20 min recovery at 20℃ with 50%RH. The results showed that finger skin blood flow and mean skin temperature were significantly higher for the FIR condition than the control during exercise and recovery (p<.001). Clothing microclimate temperature of the FIR condition was 0.5℃ higher on the back (p=.001) and 0.4℃ higher on the thigh (p=.015) during recovery. Clothing microclimate relative humidity of the FIR condition was 13% higher on the chest (p=.006) and 19% higher on the back (p<.001) during exercise than control. Subjects felt warmer and more comfortable in the FIR condition than in the control (p<.05). Perceived skin wettedness (%BSA) was less in the FIR condition than in the control (p=.001). These results indicate that ceramic-embedded clothing had significant effects on thermoregulatory responses for light activity in an indoor environment.

한냉자극(寒冷刺戟)에 대한 한국해녀의 혈관계 반응(血管系反應)에 관한 연구 (Studies on Vascular Responses to Cold Stimuli in the Korean Diving Women)

  • 백광세;김진경;한대석;강복순;홍석기
    • The Korean Journal of Physiology
    • /
    • 제3권1호
    • /
    • pp.59-66
    • /
    • 1969
  • Experiments on thermoregulatory responses to cold immersion stimulus were carried out in September, 1968 (summer studies) and February, 1969 (winter studies). Eight each of ama and control subject were selected at random from a same community in Yong-Do Island, Pusan. The results obtained are summarized as follows: 1) The rate of fall in muscle temperature of forearm during a 30 min-immersion in $6^{\circ}C$ water bath was significantly slower in the ama in winter and was about the same in the two groups in summer. However, the magnitude of change in the skin temperature and the heat fluxes observed during immersion period was not significantly different either between groups or between seasons. 2) Both finger blood flow and skin temperature during one hr-immersion in $6^{\circ}C$ water bath decreased significantly in the ama as compared to the control. The magnitude of cold-induced vasodilatation during immersion period was significantly greater in the control in winter. However, the time of onset and blood flow at onset showed no significant relation between groups. 3) The magnitude of reactive hyperemia after a 5 min-arterial occlusion in both air and $15^{\circ}C$ water bath was significantly lower in the ana than in the control. In control subjects, post-occluded blood flow in water was significantly greater than in air, while in the ama it decreased to 1/2 of control values. The time required for the return of blood flow to resting values in the air was faster in the ama than in the control but was the same in water in the two groups. 4) The results suggest that vasoconstrictor tone increased in the ama in winter, indicating the development of vascular adaptation as a part of cold acclimatization.

  • PDF

The flow of $CO_{2}$ and $N_{2}$ gases through Asymmetric polytherimide Membrane

  • Park, You-In;Lee, Kew-Ho
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1995년도 제3회 심포지움 (분리막 연구의 최신동향)
    • /
    • pp.73-85
    • /
    • 1995
  • The asymmetric hollow fiber membranes were prepared by the wet spining of polyetherimide dope solution and the effect of hollow fiber structures on the permeation characteristics of carbon dioxide and nitrogen gases through these membrane were investigated. As the concentration of the $\gamma$-butyrolactone (GBL) in dope solution, acting as a swelling agent was increased, the structure of hollow fiber was changed from the finger to sponge type. The permeabilities of gases (CO$_{2}$, N$_{2}$) through these membrane were measured over the wide range of pressure under different temperature. The effect of water vapor on the permeabilities of gases was also investigated. The measured permeabilities showed the different characteristics depending on the structure of membranes. It was found that the flow through the pores were dominant over the polymers matrix. Blocking effect by water vapor in the pores of skin layer greatly improved the ideal separation factor of carbon dioxide/nitrogen.

  • PDF

겨울철 전자 기기 사용을 위한 전도성 보온장갑의 착용성 평가 - 손의 기민성과 사용성, 체온조절 반응을 중심으로 - (Performance of Conductive Gloves When Using Electronic Devices in a Cold Environment - Manual Dexterity, Usability and Thermoregulatory Responses -)

  • 권주연;정다희;김시연;정원영;이주영
    • 한국의류산업학회지
    • /
    • 제22권5호
    • /
    • pp.686-695
    • /
    • 2020
  • The present study evaluated the manual dexterity and usability of conductive gloves when operating touchscreen devices in the cold. Twelve male subjects (23.3±1.5 years in age) participated in three experimental conditions: no gloves, fabric conductive and lambskin conductive gloves. Manual dexterity was tested using both Purdue Pegboard (PP) and ASTM dexterity tests at an air temperature of 5℃ and air humidity of 30%RH. Glove usability was tested through the following touchscreen tests: tap, double tap, long tab, drag, flick, and multi-touch. The results showed that manual dexterity according to the PP (2.5 mm of a pin diameter) and ASTM tests (8 mm of a stick diameter) was worse for the two glove conditions than for the no glove condition (p<.005). PP dexterity was better for the fabric glove condition than for the lambskin glove condition (p<.05); however, there was no difference in ASTM dexterity between the two glove conditions. Hand and finger skin temperatures were higher for the glove conditions than the bare hand condition (p<.05), with no differences between the two glove conditions. The touchscreen usability was the best for the no glove condition, followed by fabric gloves (p<.05). Wearing either fabric or lambskin gloves diminishes hand dexterity while maintaining hand and finger temperatures at higher levels. For improved hand dexterity in dealing with small numbers, letters on a touchscreen in cold environments, we recommend wearing fabric conductive gloves rather than lambskin conductive gloves.

흉강경하 흉부 교감신경간 절제술을 시행한 본태성 다한증 환자의 임상적 고찰 (Clinical Evaluation of Thoracoscopic Sympathectomy in Hyperhidrosis)

  • 오완수;강정권;연준흠;김정원;홍기혁
    • The Korean Journal of Pain
    • /
    • 제12권1호
    • /
    • pp.81-86
    • /
    • 1999
  • Background: Essential hyperhidrosis is a condition with excessive sweating, which may be localized in any parts of the body. Thoracic sympathectomy has been a surgical procedure for the management of hyperhidrosis. Methods: We studied 30 ASA I and II patients suffering from severe hyperhidrosis. Bilateral upper thoracoscopic sympathectomy of $T_{2-4}$ was performed in 30 patients under general anesthesia. Anesthesia was induced with 2.5% thiopental sodium 5 mg/kg and succinylcholine chloride 1 mg/kg and was maintained with enflurane 1~2 Vol% and $N_2O-O_2$ mixture adjusted to maintain $SpO_2$ greater than 96%. During anesthesia, invasive arterial pressure, heart rate, EKG, $SpO_2$ and capnography were monitored. Skin temperature was measured with thermister probes attached to the index finger of each hand. An increase in temperature after cautery confirmed success of the sympathectomy. Results: There were 14 men and 16 women whose ages ranged from 16 to 46 years old (mean age 22.2). Of these patients, 13 patients had complained of palm-sole hyperhidrosis, 9 of palm-sole-axilla hyperhidrosis, 4 of palm-sole-face hyperhidrosis and 4 of palm-sole-axilla-face hyperhidrosis. The provocative factors of excessive sweating were tension and stress from interpersonal relationships. There was positive familial history in 37%. The most common complication was compensatory hyperhidrosis in 23 patients comprising 76%. Other complication included peumothorax (4 patients), hemothorax (1 patient), ipsilateral Horner's syndrome (1 patient) and paresthesia of right arm (1 patient). The degree of satisfaction was graded as good, fair and poor with 15, 12 and 3 patients, respectively. Conclusions: Thoracoscopic sympathectomy with VATS is an efficient, safe and minimally invasive surgical procedure for essential hyperhidrosis.

  • PDF

멀티모달 실감 경험 I/O 인터랙션 시스템 개발 (Development for Multi-modal Realistic Experience I/O Interaction System)

  • 박재언;황민철;이정년;허환;정용무
    • 감성과학
    • /
    • 제14권4호
    • /
    • pp.627-636
    • /
    • 2011
  • 본 연구는 단순 입력 기반 유니모달 인터랙션의 한계를 극복하고 단순 입력 방식이 아닌 멀티모달 기반 사용자의 행위, 의도, 및 집중도를 활용하여 실감적이고 몰입도를 향상시키는 인터랙션 시스템을 제안하는데 그 목적이 있다. 본 연구의 선행연구에서 기존 문헌연구를 토대로 메타분석방법을 활용하여 인터랙션을 위한 3차원 동작 인식 기술의 정확도를 분석하여 최종적인 센서 기반 인터랙션 방법이 선정되었고, 직관적 제스쳐 인터랙션 요소를 추출하여 본 시스템에 반영하였다. 또한 생리반응을 이용한 집중력 판단 기술을 개발하여 사용자 의도를 판단하는 연구를 진행하였다. 본 연구에서 제안하는 시스템은 3부분으로 나눌 수 있다. 선행연구에서 선정된 인터랙션 요소들을 적용하여 가속도(Accelator) 센서와 연성(Flexible) 센서를 활용하여 손 동작을 인식하는 시스템을 구현하였고, 동공 인터랙션을 통한 안경형 시선 추적기를 구현하여 인터랙션이 가능하게 하였으며, 심혈관 반응과 피부 온열 반응을 측정하여 사용자의 의도를 반영한 시스템을 최종 구현하였다. 실감형 디지털 엔터테인먼트 플랫폼 기술 개발을 위한 기초 연구로서 활용이 가능할 것으로 판단된다.

  • PDF