• 제목/요약/키워드: fine particle concentration

검색결과 343건 처리시간 0.03초

광산란법을 이용한 국내 석탄화력발전소 굴뚝에서 배출되는 PM10, PM2.5 측정 및 분석 (Measurement and analysis of PM10 and PM2.5 from chimneys of coal-fired power plants using a light scattering method)

  • 신동호;김영훈;홍기정;이건희;박인용;김학준;김용진;한방우;황정호
    • 한국입자에어로졸학회지
    • /
    • 제16권4호
    • /
    • pp.131-140
    • /
    • 2020
  • Air pollutants emitted from chimneys of coal-fired power plants are considered to be a major source of fine particulate matter in the atmosphere. In order to manage fine particle in the chimney of a coal-fired power plant, it is necessary to know the concentration of fine particle emitted in real time, but the current system is difficult. In this study, a real-time measurement system for chimney fine particle was developed, and measurements were performed on six coal-fired power plants. Through the measurements, the mass concentration distribution according to the particle size could be secured. All six chimneys showed bimodal distribution, and the count median diameters of each mode were 0.5 and 1.1 ㎛. In addition, it was compared with the gravimetric measurement method, and it was determined that the relative accuracy for PM10 was within 20%, and the value measured using the developed measuring instrument was reliable. Finally, three power plants were continuously measured for one month, and as a result of comparing the concentration of PM10 according to the amount of power generation, it was confirmed that the PM10 discharged from the chimney increased in the form of an exponential function according to the amount of power generation.

봄철 황사의 발생과 대기 중 중금속 성분의 농도 변화 -납성분을 이용한 사례 연구 (The Influence of the Asian Dust on the Springtime Distribution of Airborne Lead)

  • 김기현;강창희;이진홍;최금찬;윤용훈
    • 한국대기환경학회지
    • /
    • 제20권6호
    • /
    • pp.833-838
    • /
    • 2004
  • The analysis of Pb in both PM$_{2.5}$ and PM$_{10}$ fraction of aerosols was made consecutively for every spring season during four year period of 2001 through 2004. To diagnose the impact of the Asian Dust (AD) on metal concentration levels, we compared our Pb measurement data after dividing the whole data sets into AD and NAD period. The results of our analysis indicated that the concentrations of coarse particles increased significantly during the AD period, whereas an increase in the fine counterpart was of moderate degree. However, when Pb concentrations between AD and NAD were compared, the patterns were quite different. From all particle fractions, the Pb concentrations of NAD were slightly or moderately higher than those of AD. The overall results of our study suggest that an increase in particle concentrations during the AD period can cause a rather slight reduction in Pb concentration levels; this can be explained by the dilution effect associated with the increase of Pb-depleted coarse particles.s.s.

부산지역 여름철 해풍 발생 시 미세먼지와 초미세먼지 중의 이온성분 특성 (Characteristics of Fine Particle Concentration and Ionic Elements of PM2.5 during Sea Breeze Occurrences in Summertime in Busan)

  • 전병일
    • 한국환경과학회지
    • /
    • 제30권6호
    • /
    • pp.465-474
    • /
    • 2021
  • This research investigated the characteristics of fine particle concentration and ionic elements of PM2.5 during sea breeze occurrences during summertime in Busan. The PM10 and PM2.5 concentrations of summertime sea breeze occurrence days in Busan were 46.5 ㎍/m3 and 34.9 ㎍/m3, respectively. The PM10 and PM2.5 concentrations of summertime non-sea breeze occurrence days in Busan were 25.3 ㎍/m3 and 14.3 ㎍/m3, respectively. The PM2.5/PM10 ratios of sea breeze occurrence days and non-sea breeze occurrence days were 0.74 and 0.55, respectively. The SO42-, NH4+, and NO3- concentrations in PM2.5 of sea breeze occurrence days were 9.20 ㎍/m3, 4.26 ㎍/m3, and 3.18 ㎍/m3 respectively. The sulfur oxidation ratio (SOR) and nitrogen oxidation ratio (NOR) of sea breeze occurrence days were 0.33 and 0.05, respectively. These results indicated that understanding the fine particle concentration and ionic elements of PM2.5 during sea breeze summertime conditions can provide insights useful for establishing a control strategy of urban air quality.

1994년 6월 서울지역 시정장애의 측정 및 분석 (Measurement and Analysis of Visibility lmpairment during June, 1994 in Seoul)

  • 백남준;이종훈;김용표;문길주
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.407-419
    • /
    • 1996
  • Characteristics of visual air quality in Seoul have been investigated between June 13 and 21, 1994. Optical properties (extinction coefficient and particle scattering coefficient), meteorological parameters (relative humidity, temperature, wind speed, wind direction, and cloud cover), particle characteristics (mass size distribution, components) were measured and analyzed. During measurement periods, northwest wind with less than 2m/sec of wind speed deteriorates visibility. Effects of relative humidity are though to be not a direct factor which influence to visibility through the size change due to hygroscopic species in aerosol. During the smoggy period both the aerosol mass concentration and fine particle fraction of the size distribution are increased compared to the clear period. Sulfate, organic carbon, and elemental carbon in aerosol are the major species in determining the occurrence and severity of a smog in Seoul.

  • PDF

샘플유량과 기상조건에 따른 미세먼지 중량 측정용 기구간의 농도 비교 (Comparative Evaluation of Gravimetric Measurement Samplers for Fine Particles by Sampling Flow Rates and Meteorological Conditions)

  • 양원호;김대원;김진국;윤충식;허용;이부용
    • 한국환경과학회지
    • /
    • 제14권1호
    • /
    • pp.91-96
    • /
    • 2005
  • Several samplers using gravimetric methods such as high-volume air sampler, MiniVol portable sampler, personal environmental monitor(PEM) and cyclone were applied to determine the concentrations of fine particles in atmospheric condition. Comparative evaluation between high-volume air sampler and Minivol portable sampler for $PM_{10}$, and between Minivol portable sampler and PEM was undertaken from June, 2003 to January 2004. Simultaneously, meteorological conditions such as wind speed, wind direction, relative humidity and temperature was measured to check the factors affecting the concentrations of fine particles. In addition, particle concen­trations by cyclone with an aerodynamic diameter of $4{\mu}m$ were measured. Correlation coefficient between high­volume air sampler and portable air sampler for $PM_{10}$ was 0.79 (p<0.001). However, the mean concentration for $PM_{10}$ by high-volume air sampler was significantly higher than that by Minivol portable sampler (p=0.018). Correlation coefficient between Minivol portable sampler and PEM for $PM_{2.5}$ as 0.74 (p<0.001), and the measured mean concentrations for $PM_{2.5}$ did not show significant difference. Difference of the measured con­centrations of fine particle might be explained by wind speed and humidity among meteorological conditions. Particle concentration differences by measurement samplers were proportional to the wind speed, but inversely proportional to the relative humidity, though it was not a significant correlation.

화력발전소의 미세먼지 배출특성 (Emission Characteristics of Fine Particles from Thermal Power Plants)

  • Park, Sooman;Lee, Gayoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.455-460
    • /
    • 2020
  • In order to identify the characteristics of fine particle emissions from thermal power plants, this study conducted measurement of the primary emission concentration of TPM, PM10 and PM2.5 according to Korea standard test method (ES 01301.1) and ISO 23210 method (KS I ISO 23210). Particulate matters were sampled in total 74 units of power plants such as 59 units of coal-fired power plants, 7 units of heavy oil power plants, 2 units of biomass power plant, and 6 units of liquid natural gas power plants. The average concentration of TPM, PM10, PM2.5 by fuel are 3.33 mg/m3, 3.01 mg/m3, 2.70 mg/m3 in coal-fired plant, 3.02 mg/m3, 2.99 mg/m3, 2.93 mg/m3 in heavy oil plant, 0.114 mg/m3, 0.046 mg/m3, 0.036 mg/m3 in LNG plant, respectively. These results of TPM, PM10 and PM2.5 were satisfied with the standards of fine dust emission allowance in all units of power plants, respectively. Also, this study evaluated the characteristics of fine particle emissions by conditions of power plants including generation sources, boiler types and operation years and calculated emission factors and then evaluated fine particle emissions by sources of electricity generation.

미세먼지 입경농도 분포의 지역별 특성 (Regional Characteristics of Particle Size Distribution of PM10)

  • 이용기;이기종;이재성;신은상
    • 한국대기환경학회지
    • /
    • 제28권6호
    • /
    • pp.666-674
    • /
    • 2012
  • The purpose of this study is to propose management strategies to lower the level of $PM_{10}$ concentration. First, this study analyzes the characteristics of particle sizes in three different areas, the residential, the roadside, and the industrial areas. Second, it has examined the size of particles which can influence on the increase of $PM_{10}$ concentration level. The distribution of particle size for $PM_{10}$ concentration was not different by regions. The highest portion in the observed $PM_{10}$ is near $0.3{\mu}m$. In addition, both near $2.5{\mu}m$ and near $5.0{\mu}m$ are found higher in portion. The fractions of $PM_{1.0}$ and $PM_{2.5}$ in $PM_{10}$ are 68.2% and 75.8% respectively. The fraction of $PM_{1.0}$ in $PM_{2.5}$ is 89.8%. The particle diameters contributed to the increase of $PM_{10}$ concentration are different by regions. In the residential area, the sizes of near $0.6{\mu}m$ and near $3.3{\mu}m$ particles are found to be the cause for the increase of $PM_{10}$ concentration level. However the particle sizes for the increase of $PM_{10}$ concentration level are $0.8{\mu}m$ and $0.5{\mu}m$ in roadside and industrial area respectively. Therefore, fine particles are found as the key factors to raise $PM_{10}$ concentration level in the two areas, while both fine and coarse particles are in the residential areas. When examined the $PM_{10}$ concentration level change, it was categorized by two different time zones, the high concentration level time and the lower concentration time. In high concentration time, the $PM_{10}$ concentration has increased in the morning in the residential and roadside areas. On the contrary, the level has increased in the evening in the industrial area. In low concentration time, the level of $PM_{10}$ concentration in the roadside area is significantly higher in the morning than the concentration level of other times. There is no significantly different concentration level found in the both residential and industrial areas throughout the day.

부산지역 2021년 2월 1일~2일 연속적인 2개의 한랭전선 통과 시 기상요소와 미세먼지 농도의 특성 (Meteorological Parameters and Fine Particle Concentration during Two Successive Cold Fronts in Busan on 1~2 February 2021 )

  • 전병일
    • 한국환경과학회지
    • /
    • 제31권12호
    • /
    • pp.1069-1078
    • /
    • 2022
  • This study investigated the weather conditions, fine particle concentration, and ion components in PM2.5 when two cold fronts passed through Busan in succession on February 1 and 2, 2021. A analysis of the surface weather chart, AWS, and backward trajectory revealed that the first cold front passed through the Busan at 0900 LST on February 1, 2021, with the second cold front arriving at 0100 LST on February 2, 2021. According to the PM10 concentration of the KMA, the timing of the cold front passage had a close relationship with the occurrence of the highest concentration of fine particles. The transport time of the cold front from Baengnyeongdo to Mt. Gudeok was approximately 11 hours . The PM10 and PM2.5 concentrations in Busan started to increase after the first cold front had passed, and the maximum concentration occurred two hours after the second cold front passed. The SO42-, NO3-, and NH4+ concentration in PM2.5 started to increase from 1100 to 1200 LST on February 1, after the first cold front passed, and peaked at 0100 LST to 0300 LST on February 2. However, the highest Ca2+ concentration was recorded 2-3 hours after the second cold front had passed.

일본 니시노시마 화산 분출이 2020년 8월 초 부산지역의 미세먼지 농도에 미치는 영향 (Effect of the Nishinoshima Volcanic Eruption on Fine Particulate Concentration in Busan in Early August 2020)

  • 전병일
    • 한국환경과학회지
    • /
    • 제31권12호
    • /
    • pp.1079-1087
    • /
    • 2022
  • This study investigated the effect of volcanic materials that erupted from the Nishinoshima volcano, Japan, 1,300 km southeast of the Busan area at the end of July 2020, on the fine particle concentration in the Busan area. Backward trajectory analysis from the HYSPLIT model showed that the air parcel from the Nishinoshima volcano turned clockwise along the edge of the North Pacific high pressure and reached the Busan area. From August 4 to August 5, 2020, the concentration of PM10 and PM2.5 in Busan started to increase rapidly from 1000 LST on August 4, and showed a high concentration for approximately 13 hours until 2400 LST. The PM2.5/PM10 ratio showed a relatively high value of 0.7 or more, and the SO2 concentration also showed a high value at the time when the PM10 and PM2.5 concentrations were relatively high. The SO42- concentration in PM2.5 in Busan showed a similar trend to the change in PM10 and PM2.5 concentrations. It rose sharply from 1300 LST on August 4, at the time where it was expected to have been affected by the Nishinoshima Volcano. This study has shown that the occurrence of high concentration fine particle in Busan in summer has the potential to affect Korea not only due to anthropogenic factors but also from natural causes such as volcanic eruptions in Japan.

2015년~2021년 한반도 고농도 미세먼지 사례의 유형분류에 따른 기상학적 특징 분석 (Analysis of Meteorological Characteristics by Fine Dust Classification on the Korean Peninsula, 2015~2021)

  • 지준범;조창래;김유준;박승식
    • 대기
    • /
    • 제32권2호
    • /
    • pp.119-133
    • /
    • 2022
  • From 2015 to 2021, high-concentration fine dust episodes with a daily average PM2.5 concentration of 50 ㎍ m-3 or higher were selected and classified into 3 types [long range transport (LRT), mixed (MIX) and Local emission and stagnant (LES)] using synoptic chart and backward trajectory analysis. And relationships between the fine particle data (PM2.5 and PM10 concentration and PM2.5/PM10 ratio) and meteorological data (PBLH, Ta, WS, U-wind, and Rainfall) were analyzed using hourly observation for the classification episodes on the Korean Peninsula and the Seoul metropolitan area (SMA). In LRT, relatively large particles such as dust are usually included, and in LES, fine particle is abundant. In the Korean peninsula, the rainfall was relatively increased centered on the middle and western coasts in MIX and LES. In the SMA, wind speed was rather strong in LRT and weak in LES. In LRT, rainfall was centered in Seoul, and in MIX and LES, rainfall appeared around Seoul. However, when the dust cases were excluded, the difference between the LRT and other types of air quality was decreased, but the meteorological variables (Ta, RH, Pa, PBLH, etc.) were further strengthened. In the case of the Korean Peninsula, it is difficult to find a clear relationship because regional influences (topographical elevation, cities and coasts, etc.) are complexly included in a rather wide area. In the SMA, it is analyzed that the effects of urbanization such as the urban heat island centered on Seoul coincide with the sea and land winds, resulting in a combination of high concentrations and meteorological phenomena.