• Title/Summary/Keyword: fine needle

Search Result 765, Processing Time 0.03 seconds

Fine Needle Aspiration Cytology of Endodermal Sinus Tumor of the Ovary - A Case Report - (난소 내배엽동 종양의 세침흡인 세포학적 소견 - 1예 보고 -)

  • Kim, Jin-Man;Kang, Dae-Young
    • The Korean Journal of Cytopathology
    • /
    • v.6 no.1
    • /
    • pp.54-57
    • /
    • 1995
  • We report a case of fine needle aspiration cytology of endodermal sinus tumor of the ovary. A 13-year-old girl complained of abdominal mass and pain. The abdominal sonography revealed a well-demarcated huge mass, which was solid and multiseptated. Percutaneous fine needle aspiration was performed from the mass. The smears revealed moderate cellularity, which was arranged in sheets or clumps of pleomorphic malignant cells on mucoid background The valuable characteristic features of tumor cells were papillary configuration, vacuolated cytoplasm and intracellular and extracellular hyaline globules. The diagnosis was confirmed later by histologic study of surgical resection of the specimen.

  • PDF

Pulmonary Nocardiosis Diagnosed by Fine Needle Aspiration - A Case Report - (세침흡인 세포학적 검사로 진단한 폐의 Nocardiosis - 1예 보고 -)

  • Yim, Hyun-Ee;Park, Kwang-Hwa
    • The Korean Journal of Cytopathology
    • /
    • v.6 no.2
    • /
    • pp.169-173
    • /
    • 1995
  • Nocardia, aerobic members of the order of Actinomycetaceae, produces infections in human lung. Nocardial infection is associated with underlying diseases of immuno-suppression or treatment with corticosteroid. It is difficult to detect Nocardia by sputum examination or histologic sections and it has rarely been diagnosed by fine needle aspiration of the lung. We describe a case of pulmonary nocardiosis in a 72 year-old man, diagnosed by fine needle aspiration, which was confirmed by culture of aspirates. The aspirates showed neutrophil-predominant inflammatory cells with microorganisms demonstrated by Gomori methenamine silver and Gram stain. The organisms had characteristic long blanching filamentous structures. The lesions on chest X-ray were in resolution with antimicrobial therapy.

  • PDF

Fine Needle Aspiration Cytology of Pigmented Villonodular Synovitis - A Case Report - (착색성 융모결절성 활막염의 세침흡인 세포학적 소견 - 1예 보고 -)

  • Choi, Joon-Hyuk;Bae, Young-Kyung;Shim, Young-Ran;Kim, Mi-Jin;Choi, Won-Hee
    • The Korean Journal of Cytopathology
    • /
    • v.10 no.2
    • /
    • pp.191-195
    • /
    • 1999
  • Pigmented villonodular synovitis is a destructive, fibrohistiocytic proliferation producing innumerable villous and nodular synovial protrusions. Its common locations are knee, ankle, foot, and hip. Although histologic feature of this tumor is well known, there have been few reports on the fine needle aspiration cytology findings. We report the cytologic features of a biopsy-proven case oi pigmented villonodular synovitis. The patient was a 21-year-old male with a mass of the right knee for 2 years. On fine needle aspiration cytology, the aspirates was composed of abundant mononuclear histiocytic cells, singly and in clusters, multinucleated slant cells, and hemoslderin pigments.

  • PDF

Fine Needle Aspiration Cytological Findings of Burkitt lymphoma -A Brief Case Report- (버킷 림프종의 세침흡인 세포소견 -짧은 증례 보고-)

  • Jo, Hyang-Jeong;Oh, Jung-Taek;Kim, Gang-Deuk;Kim, Hun-Soo
    • The Korean Journal of Cytopathology
    • /
    • v.18 no.2
    • /
    • pp.175-177
    • /
    • 2007
  • A case of Burkitt lymphoma diagnosed through fine needle aspiration cytology is described, A 66-year-old man presented with lymphadenopathy on the right cervical neck and axillary area. An ultrasonogram and CT scan for the cervical neck showed a multiple variable sized lymphadenopathy with pericapsular invasion and necrotic foci, Fine needle aspiration cytology (FNAC) of the cervical lymph nodes revealed very cellular and necrotic smears consisting of diffusely scattered intermediate monotonous round cells, tingible body macrophages and many mitotic figures. Histological features of the excised lymph nodes showed the classic morphological features of Burkitt lymphoma. Recognition of the characteristic cytological features can suggest the possibility of Burkitt lymphoma.

Fabrication of Fine Organic Thin-Film Stripes Using a Hydrophobic Needle (소수성 Needle을 이용한 미세 유기 박막 Stripe 제작)

  • Kim, Jongmyeong;Lee, Jinyoung;Shin, Dongkyun;Park, Jongwoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.1
    • /
    • pp.73-78
    • /
    • 2020
  • There appears lateral capillary force in a hydrophilic flat needle employed for the fabrication of fine organic thin-film stripes, bringing in an increase of the stripe width. It also causes the stripe thickness to increase with increasing coating speed, which is hardly observed in a normal coating process. Through computational fluid dynamics (CFD) simulations, we demonstrate that the lateral capillary flow can be substantially suppressed by increasing the contact angle of the needle end. Based on the simulation results, we have coated the outer surface of the flat needle with a hydrophobic material (polytetrafluoroethylene (PTFE) with the water contact angle of 104°). Using such a hydrophobic needle, we can suppress the lateral capillary flow of an aqueous poly(3,4-ethylenedioxythiophene): poly(4-styrenesulfonate) (PEDOT:PSS) to a great extent, rendering the stripe narrow (63 ㎛ at 30 mm/s). Consequently, the stripe thickness is decreased as the coating speed increases. To demonstrate its applicability to solution-processable organic light-emitting diodes (OLEDs), we have also fabricated OLED with the fine PEDOT: PSS stripe and observed the strong light-emitting stripe with the width of about 68 ㎛.

Prospective Assessment of the Performance of a New Fine Needle Biopsy Device for EUS-Guided Sampling of Solid Lesions

  • El Hajj, Ihab I.;Wu, Howard;Reuss, Sarah;Randolph, Melissa;Harris, Akeem;Gromski, Mark A.;Al-Haddad, Mohammad
    • Clinical Endoscopy
    • /
    • v.51 no.6
    • /
    • pp.576-583
    • /
    • 2018
  • Background/Aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) remains the most common EUS-guided tissue acquisition technique. This study aimed to evaluate the performance of a new Franseen tip fine needle biopsy (FNB) device for EUSguided sampling of solid lesions and compare it with the historical FNA technique. Methods: $Acquire^{(R)}$ 22 G FNB needle (Boston Scientific Co., Natick, MA, USA) was used for solid tumor sampling (Study group). Tissue was collected for rapid on-site evaluation, and touch and crush preparations were made. Historical EUS-FNA samples obtained using $Expect^{(R)}$ 22 G FNA needle (Boston Scientific Co.) were used as controls (Control group). All specimens were independently evaluated by two cytopathologists blinded to the formal cytopathological diagnosis. Results: Mean cell block histology scores were significantly higher (p=0.046) in the FNB group (51 samples) despite a significantly lower (p<0.001) mean number of passes compared to the FNA group (50 specimens). The overall diagnostic yields for the FNB vs. FNA groups were 96% vs. 88%. The degree of tumor differentiation was adequately assessed in all cell block qualifying lesions in the FNB group. Two patients developed post-FNB abdominal pain. Conclusions: The new Franseen tip FNB device provides histologically superior and cytologically comparable specimens to those obtained by FNA, but with fewer passes.

Polymerase Chain Reaction Detection of Mycobacterium tuberculosis and Fine Needle Aspiration Cytology for the Diagnosis of Tuberculous Lymphadenitis (결핵성 림프절염의 진단를 위한 세침흡인 세포검사 및 중합효소연쇄 반응과 효소면역법을 이용한 Mycobacterium tuberculosis의 검출)

  • Kim, Joo-Heon;Kim, Nam-Hoon;Kang, Dong-Wook;Park, Mee-Ja;Moon, Sang-Kyoung;Yu, Tae-Cho;Jang, Eun-Ju
    • The Korean Journal of Cytopathology
    • /
    • v.12 no.1
    • /
    • pp.25-30
    • /
    • 2001
  • Tuberculous lymphadenitis is not uncommon in Korea. Therefore, an inexpensive, safe and rapid method is needed to diagnose the tuberculous lymphadenitis. Flne needle aspiration cytology Is a good method for this purpose, but has several limitations in the diagnosis of tuberculous lymphadenitis, especially when the presence of acid-fast bacilli is not proved. To evaluation the usefulness of the polymerase chain reaction with enzyme immunoassay technique in the detection of Mycobacterium tuberculosis (M. tuberculosis) In the cervical Iymph node asplrates, the authors performed fine needle aspiration cytology and M. tuberculosis PCR with enzyme immunoassay for mycobacterial DNA sequences from 15 cases of the fine needle aspirates. Cytomorphologically, the cases were categorized into three types: predominantly necrotic materials; typical epithelioid cell granulomas with or without slant cells and caseous necrosis; and non-tuberculous lesions, such as reactive lymphadenitis, abscess, metastatic carcinoma and malignant lymphoma. M. tuberculosis DNA was found in 8 of 15 cases by PCR with enzyme immunoassay. Negative findings on PCR were achieved in 7 cases, which revealed non-tuberculous tymphadenopathy. In conclusion, we suggest that M. tuberculosis PCR with enzyme immunoassay using the fine needle aspirates is a very useful tool for the diagnosis of tuberculous lymphadenitis.

  • PDF

Fabrication of Fine PEDOT:PSS Stripes Using Needle Coating (Needle 코팅을 이용한 미세 PEDOT:PSS 스트라이프 제작)

  • Lee, Jinyoung;Park, Jongwoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.3
    • /
    • pp.100-104
    • /
    • 2019
  • We have investigated the feasibility of fabricating fine stripes using needle coating for potential applications in solution-processed organic light-emitting diodes (OLEDs). To this end, we have employed an aqueous poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate) (PEDOT:PSS) solution that has been widely used as a hole injection layer (HIL) of OLEDs and performed needle coatings by varying the process parameters such as the coating gap and coating speed. As expected, the stripe width is reduced with increasing coating speed. However, the central thickness of the stripe is rather increased as the coating speed increases, which is different from other coating processes such as slot-die and blade coatings. It is due to the fact that the meniscus formed between the needle tip and the substrate varies depending sensitively on the coating speed. It is also found that the stripe width and thickness are reduced with increasing coating gap. To demonstrate its applicability to OLEDs, we have fabricated a red OLED stripe and obtained light emission with the width of about 90㎛.

Diagnostic Pitfalls in Breast Fine Needle Aspiration Cytology: False Positive and False Negative (유방 세침흡인 세포검사의 진단적 함정: 위양성과 위음성)

  • Park, Kyeong-Mee
    • The Korean Journal of Cytopathology
    • /
    • v.18 no.2
    • /
    • pp.112-118
    • /
    • 2007
  • Fine needle aspiration cytology (FNAC) has become a highly preferred, minimally invasive diagnostic tool of choice in the diagnosis of a palpable breast mass owing to its sensitivity, specificity, cost-effectiveness, and expediency. Although breast needle biopsies have been widely employed recently due to the increased detection rate of non-palpable early lesions, the importance of the use of FNAC cannot be underestimated. It comprises part of the diagnostic triad for the breast along with a physical examination and mammography, which together contribute to an increasing diagnostic accuracy. The differential diagnosis of a benign and malignant lesion is of the utmost importance in the diagnosis of breast lesions, and therefore the understanding of the possible diagnostic pitfalls is of great importance.

Fine Needle Aspipration Cytology of Metastatic Pulmonary Seminoma - A Cese Report - (세침흡인 세포검사로 진단된 폐에 전이한 정상피종 - 1예 보고 -)

  • Jeong, Hwa-Sook;Lee, Geon-Kook;Kim, Wun-Jae;Earm, Jae-Ho;Song, Hyung-Geun
    • The Korean Journal of Cytopathology
    • /
    • v.7 no.1
    • /
    • pp.97-102
    • /
    • 1996
  • Fine needle aspiration cytology of a pulmonary mass was performed on a 51-year-old man who had a left testicular mass. Cytologic features were composed of a homogeneous population of malignant cells associated with a background of foamy and lacelike material. The cellular features were characterized by monomorphous cell proliferation of relatively regular large cells, generally isolated or grouped. Occasionally, fine blanching stroma with large tumor cells and scanty lymphocytes were noted. The tumor cells had a round, regular nucleus, prominent round nucleoli, and a thin rim of cytoplasm containing large vacuoles or lacunae filled with glycogen. The fine needle aspiration cytologic diagnosis was highly consistent with metastatic seminoma from testis and less likely primary or other metastatic carcinoma. The diagnosis of resected testicular mass was classic seminoma. Despite the fact that cytopathologists were not familial with diagnosis of seminoma due to clinician's lack of interest in fine needle aspiration cytology of germ cell tumors including seminoma, it appears that a diagnosis of this tumor should not be problematic in cytologic material if specific histologic criteria are applied.

  • PDF