• Title/Summary/Keyword: fine line

Search Result 460, Processing Time 0.034 seconds

Maximum Optical Coupling Point Search Algorithm for Manufacturing of Optical Device (광전소자 제조를 위한 최대 광 결합점 검색 알고리즘)

  • 한일호;김회율
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.9-12
    • /
    • 2001
  • Optical aligning process to archive the maximum optical coupling is crucial in many optical device manufacturing line such as laser diode module. Due to the three-dimensional nature of housing module and the aligning process for laser diode coupler, large amount of the manufacturing time, typically ranging from tens of minutes to an hour has to be devoted to the aligning process alone. In this thesis, we propose a new optical aligning process that employee a two-pass algorithm: coarse-to-fine search. Coarse search is a kind of blind search that finds the candidate region where the maximum optical coupling might mostly occur, followed by a fine searching that finds the maximum within the candidate region. The algorithm has been tested on 50 samples of cam-type laser diode modules, and the experimental results are analyzed in terms of aligning time and coupling efficiency.

  • PDF

The Design of a 0.15 ps High Resolution Time-to-Digital Converter

  • Lee, Jongsuk;Moon, Yong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.3
    • /
    • pp.334-341
    • /
    • 2015
  • This research outlines the design of a HR-TDC (High Resolution Time-to-Digital Converter) for high data rate communication systems using a $0.18{\mu}m$ CMOS process. The coarse-fine architecture has been adopted to improve the resolution of the TDC. A two-stage vernier time amplifier (2S-VTA) was used to amplify the time residue, and the gain of the 2S-VTA was larger than 64. The error during time amplification was compensated using two FTDCs (Fine-TDC) with their outputs. The resolution of the HR-TDC was 0.15 ps with a 12-bit output and the power consumption was 4.32 mW with a 1.8-V supply voltage.

A Study on the High Selective Oxide Etching using Inductively Coupled Plasma Source (유도결합형 플라즈마원을 이용한 고선택비 산화막 식각에 관한 연구)

  • 이수부;박헌건;이석현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.4
    • /
    • pp.261-266
    • /
    • 1998
  • In developing the high density memory device, the etching of fine pattern is becoming increasingly important. Therefore, definition of ultra fine line and space pattern and minimization of damage and contamination are essential process. Also, the high density plasma in low operating pressure is necessary. The candidates of high density plasma sources are electron cyclotron resonance plasma, helicon wave plasma, helical resonator, and inductively coupled plasma. In this study, planar type magnetized inductively coupled plasma etcher has been built. The density and temperature of Ar plasma are measured as a function of rf power, flow rate, external magnetic field, and pressure. The oxide etch rate and selectivity to polysilicon are measured as the above mentioned conditions and self-bias voltage.

  • PDF

Photo-imageable Thick-Film Lithography Technology for Embedded Passives Fabrication (내장형 수동소자의 제조를 위한 포토 이미징 후막리소그라피 기술)

  • Lim, Jong-Woo;Kim, Hyo-Tea;Kim, Jong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.303-303
    • /
    • 2007
  • Photo-imageable thick-film lithography technology was developed for the fabrication of embedded passives such as inductors and capacitors. In this study, photo-imageable dielectric and conductor pastes have apoted a negative type. Sodalime glass wafer, alumina substrate and zero-shrinkage LTCC green tapes were used as substrates. In result, The lithographic patterns were designed as lines and spaces for conductor material, or via-holes for ceramic, LTCC, materials. The scattering and reflection of UV-beam on the substrate had negative effects on fine patterning. The patterning performance was varied with the exposing and developing process conditions, and also varied with the substrate materials. Fine resolution of less then $50/50{\mu}m$ in line and space was obtained, which is difficult in screen printing method.

  • PDF

Eco-design Clothing Purchase, Usage and Disposal -A Cross-country Study of China and Korea-

  • Jin, Cheng;Cui, Yu Hua
    • Journal of Fashion Business
    • /
    • v.23 no.3
    • /
    • pp.10-22
    • /
    • 2019
  • Eco-design is an environmental key point since consumers' consumption behaviors have huge impacts on the environment. The objective of this study was to investigate the various responses between Chinese and Korean consumers and to look into the effects that consumers' environmental awareness have on eco-design clothing product purchase, usage and disposal. The study comprised of literature review and empirical research conducted through on line survey (www .sojump.com) from 5-20th Jan 2019. 200 Chinese respondents and 200 Korean respondents were collected and structural equation modeling (SEM) was used to test the research hypotheses. The results suggested that consumers' environmental awareness positively influenced their three ecological dimensions about consumption. In addition, the positive relationship was also influenced by respondents' nationality. These results suggest that consumers' environmental awareness is an important responsibilities and could become more important retail mix for clothing marketers. Findings would also enable environmental organizations to understand eco behavior and to design appropriate strategic decisions to appeal eco-summers. Other findings and implications were also discussed.

Design of a Small Radio Frequency Identification Tag Antenna Using a Corrugated Meander Line Applicable to a Drug Runout Sensor System

  • Ko, Dong-Ok;Woo, Jong-Myung
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.1
    • /
    • pp.7-12
    • /
    • 2018
  • This article proposes an ultrahigh frequency band radio frequency identification (RFID) tag antenna for drug runout management that can be used in hospitals. The RFID tag antenna is designed to function as a sensor that alerts drug runout when a drug inside a drip chamber is completely consumed but does not work when a drug remains inside a drop chamber. A previously proposed 915 MHz dipole antenna, is too large to be attached to the drip chamber of a feeding bag. Moreover, the length of the dipole (L) should be increased for conjugate matching with an RFID chip. Therefore, the dipole antenna is downsized so that it can be attached to the drip chamber through a fine meander line structure coupling with a corrugate meander line. A transparent cover is added to enhance the grip force between the designed antenna and the drip chamber and to enable detachment. The dimensions of the completed antenna structure attachable to a drip chamber are 32.59 mm (height) and 13.5 mm (width). The gain reduction due to the decreased antenna length is enhanced. The fabricated antenna shows an average omni-directional read range of 10.65 m on a horizontal plane and has the function of sensing the presence of a drug.

Study on the Calculation of the Optimal Power System Operation Considering Line Contingencies and Line Capacities (선로사고 및 선로용량을 고려한 전력계통 최적운영에 관한 연구)

  • 박영문;백영식;서보혁;신중린
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.9
    • /
    • pp.609-615
    • /
    • 1987
  • The optimal operation of power system is developed by alternately using real power dispatch and reactive power dispatch problem. The real power system scheduling process is formulated as an optimization problem with linear inequality constraints. A.C. loadflow method is used for the problem solution and line losses are considered. The constraints under consideration are generator power limits, load scehdling limits and line capacity limits. In solving the objective function the Dual Relaxation method is adopted. Tests indicate that the method is practical for real time application. The reactive power control problem uses the Dual Simplex Relaxation method as in the real scheduling case. Insted of minimizing the cost of power system, the objective is selected as to determine the highest possible voltage schedule. The constraints under consideration are the voltage limits at each node and the possibilities of supply or absobtion of reactive energy by generator units and the compensation facilities. Tests indicate that the method is practical for real time applications. The overall optimization methods developed in this paper proved to obtained fine results in minimizing object function compared with the method without using voltage control. And the overall voltage profiles were also improved.

  • PDF

A Study on the Vision Sensor System for Tracking the I-Butt Weld Joints (I형 맞대기 용접선 추적용 시각센서 시스템에 관한 연구)

  • Bae, Hee-Soo;Kim, Jae-Woong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.9
    • /
    • pp.179-185
    • /
    • 2001
  • In this study, a visual sensor system for weld seam tracking the I-butt weld joints in GMA welding was constructed. The sensor system consists of a CCD camera, a diode laser with a cylindrical lens and a band-pass-filter to overcome the degrading of image due to spatters and arc light. In order to obtain the enhanced image, quantitative relationship between laser intensity and iris number was investigated. Throughout the repeated experiments, the shutter speed was set at 1-milisecond for minimizing the effect of spatters on the image, and therefore most of the spatter trace in the image have been found to be reduced. Region of interest was defined from the entire image and gray level of searched laser line was compared to that of weld line. The differences between these gray levels lead to spot the position of weld joint using central difference method. The results showed that, as long as weld line was within $^\pm$15$^\circ$from the longitudinal straight fine, the system constructed in this study could track the weld line successful1y. Since the processing time reduced to 0.05 sec, it is expected that the developed method could be adopted to high speed welding such as laser welding.

  • PDF

High density line patterns fabricated by thermal imprint (Thermal imprint를 이용한 고밀도 line패턴 형성방법)

  • Lee, Sang-Moon;Kwak, Jung-Bok;Lee, Hwan-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.270-270
    • /
    • 2008
  • We present details of experimental results in the fabrication of high density line patterns, using imprint technique that can provide a simple and comparatively cost-effective manufacturing means. Barrier array structures for display or interconnects for semiconductor applications were the aims of this study. For pattern fabrication, a polymer layer (Ajinomoto GX-13 dielectric film) with a thickness of 38um that can act as either an insulating or a dielectric layer was laminated on a substrate. Fine tracks were then formed using a patterned stamp under isostatic pressure. The line width was ranged between 10 to 60 mm. A self-assembled monolayer (SAM) of fluorinated alkylchlorosilane [$CF_3(CF_2)5(CH_2)2SiCl_3$] as an anti-sticking layer was coated on the surface of the stamp prior to thermal imprint to improve the de-molding characteristic.

  • PDF

Effects of Total Sleep Deprivation on Fine Motor Performance (전수면박탈이 정상인의 미세운동수행 능력에 미치는 영향)

  • Lee, Heon-Jeong;Song, Hyung-Seok;Ham, Byung-Joo;Suh, Kwang-Yoon;Kim, Leen
    • Sleep Medicine and Psychophysiology
    • /
    • v.8 no.2
    • /
    • pp.129-137
    • /
    • 2001
  • Objectives: The purpose of this study is to investigate the effects of 38-hour sleep deprivation on fine motor performance. The Motor Performance Series (MPS) in the Vienna Test System (computerized neurocognitive function tests) was used in this study. Methods: Twenty four subjects participated in this study. Subjects had no past history of psychiatric disorders and physical illness. Subjects had normal sleep-waking cycle without current sleep disturbances and were all right-handed (Annett's Hand Preference Questionnaire: above +9 points). To minimize the learning effects, familiarization with the Vienna Test System was performed one day before the study. Subjects were to get up at 6:00 in the morning after getting enough sleep according to his or her usual sleep-wake cycle. After awakening, subjects remained awake for 38 hours under continuous surveillance. During two consecutive study days, the subjects tested MPS at 7 AM and 7 PM each day, which means the MPS was done four times in total. During the experiment, anything that could affect the subjects' sleep such as coffee, tea, alcohol, a nap, tiring sports, and all medications were prohibited. Results: In MPS, the fine motor functions of both hands decreased after 38 hours of sleep deprivation. The decrement in motor performance was prominent in the dominant right hand. In the right hand, the total number of tapping was reduced (p<.005), and the number of misses (p<.05) and the length of misses (p<.05) of line tracking, the total length of inserting a short pin (p<.01), the total length of inserting a long pin (p<.05), and the number of misses in aiming (p<.05) increased. Such performance decrement was distinct in the morning sessions. Conclusions: These results suggest that fine motor performance decrement during sleep deprivation is predominant in the right hand, which exerts maximal motor function. The finding of decrement in motor function in tapping during sleep deprivation also suggested that the time required for exhaustion of muscles is shortened during sleep deprivation. More deterioration of motor performance was shown in the morning, which could be explained as circadian rhythm effects.

  • PDF