• Title/Summary/Keyword: fin tube

Search Result 466, Processing Time 0.02 seconds

Experimental Study on the Air-Side Heat Transfer Characteristics of a Spirally-Coiled Circular Fin-Tube Heat Exchanger According to Geometric Parameters (형상변수에 따른 나선형 원형핀-튜브 열교환기의 공기측 열전달 특성에 관한 실험적 연구)

  • Kang, Tae-Hyung;Lee, Moo-Yeon;Kim, Yong-Chan;Yun, Sung-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.5
    • /
    • pp.515-522
    • /
    • 2010
  • The objective of this study is to investigate the air-side heat transfer characteristics of a spirally-coiled circular fin-tube heat exchanger for various geometric parameters under non-frosting conditions. The heat transfer characteristics of the heat exchanger were analyzed with respect to heat exchanger geometries, and then, the characteristics were compared with those of rectangular-plate fin-tube heat exchangers with discrete fins. The heat transfer coefficient increased with a decrease in the number of tube rows and an increase in the fin pitch. The optimum length of the L-foot was 2.7 mm. In addition, the heat transfer rate increased with a decrease in the tube pitch and the tube thickness. The heat transfer coefficient of the spirally-coiled circular fin-tube heat exchanger was 24.3% higher than that of the rectangular-plate fin-tube heat exchanger.

A Study on the Entropy Generation of Single Fin-Tube Heat Exchanger (단일 핀-관 열교환기에서 엔트로피 생성에 관한 연구)

  • Pak, Hi-Yong;Lee, Kwan-Soo;Kim, Byoung-Kue
    • Solar Energy
    • /
    • v.10 no.1
    • /
    • pp.14-21
    • /
    • 1990
  • The entropy generation rate in a fin-tube heat exchanger is investigated as a basis for thermodynamic optimization associated with single fin-tube heat exchanger. The entropy generation (irreversibility)analysis is used to find the optimum design factor and investigate total entropy generation, optimum dimensions of fin length, tube inner and outer diameters, and fin spacing on the variation of design factors. The results of this study are as follows: As the outer diameter increases, optimum !in spacing and fin length increase but the entropy generation and optimum inner diameter decrease; As fin thickness increases, the entropy generation of system and optimum fin spacing increase; As fin length increases, entropy generation and optimum outer diameter increase.

  • PDF

A Study on the Improement of Condensation and Boiling Heat Transfer on Horizontal Tube by Fin Effect(ll)-Shellside Condensation- (수평 원형전열관의 핀효과에 의한 응축 및 비등 열전달촉진에 관한 연구 (2)-튜브외부 응축-)

  • 한규일;조동현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1275-1287
    • /
    • 1994
  • Heat transfer performance improvement by fin and grooves is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapezoidal shaped integral-fins having fin densities from 748 to 1654 fpm and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also tested for comparison. R-11 condenses at saturation state of $32^{\circ}C$ on the outside tube surface cooled by inside water flow. All of test data ate taken at steady state. Beatty and Katz's, Rudy's and Webb's theoretical models are used to predict the R-11 condensation coefficient of tubes having 748, 1024 and 1299 fpm. The predicted value by Betty and Katz's model is within 10% of experimental values in this study at fpm<1024 and Rudy's model predicted the experimental data at fpm>1024 within 15%. The tube having fin density of 1299 fpm and 30 grooves has the best overall heat transfer performance. This tube shows the overall heat transfer coefficient of 11500 $W/m^{2}K$,/TEX> at coolant velocity of 3.0m/s.

Development of Hybrid Expander Unit for Fin Tube Heat Exchanger (핀튜브 열교환기용 전관확관 유닛 개발)

  • Roh, Geonsang;Kim, Jongnam
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.165-168
    • /
    • 2011
  • In this paper, the hybrid tube expander unit for fin and tube type heat exchanger are developed by means of enlarging and inserting the smooth tube with a small diameter to a finned tube having larger diameter. In other word, the tube expander tool that is easy to attach and remove from tube is developed. The hybrid tube expander unit developed in this study can move easily and enlarge the tube without fixing at tube sheet. Also, this unit has a function removing scales inside tube by replacing a tube expander ball.

Comparison of Various Heat Exchanger Performances in order for Air Compressor Intercooler Application (공기압축기의 인터쿨러 선정을 위한 열교환기의 형상별 성능해석)

  • Yoo, Sang-Hoon;Park, Sang-Gu;Yoon, Jeong-Pil;Jeong, Ji-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.73-81
    • /
    • 2008
  • Intercooling and aftercooling are required in order to operate air compressor, these are conducted through air-cooled or water-cooled heat exchangers. This study aims to find more suitable type of heat exchanger as a water-cooled intercooler of air compressor. Comparative performance evaluation among fin-tube heat exchanger and shell-and-tube (S&T) heat exchanger having various tubes such as circular tube, spiral tube, and internally finned tube was conducted. Thermal-hydraulic performance of each heat exchanger type is evaluated in terms of temperature drop and pressure drop. The comparisons show that shell-and-tube heat exchangers may have similar and larger heat transfer capacity to the fin-tube heat exchanger if tube diameter is reduced and multiple pass is adopted. For these cases, however, compressed air pressure drop in shell-and-tube heat exchanger become much larger than that in fin-tube heat exchanger.

Heat Transfer Correlation for the Forced Convective Flow on Single Circular Fin-tube Heat Exchanger

  • Kang Hie-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.1
    • /
    • pp.14-18
    • /
    • 2006
  • This study was performed to investigate the heat transfer characteristics of the circular fin-tube heat exchanger. This paper contains the experimental data for the seven kinds of fin geometries. The correlation of Stasiulevicius agreed with the experimental data at high Reynolds number, however not well at low Reynolds number. The Nusselt number was well correlated with Graetz number, and showed a transition near Gz=10. An empirical correlation proposed in the present study agreed well with the experimental data.

Forced Convection Correlation for Single Circular Fin-tube Heat Exchanger (단일 원형휜-원형관에 대한 강제대류열전달 상관식)

  • 강희찬;강민철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.6
    • /
    • pp.584-588
    • /
    • 2004
  • This work was performed to investigate the heat transfer characteristics of the circular fin-tube heat exchanger. This paper contains the experimental data for the seven kinds of fin geometries. The correlation of Stasiulevicius agreed with the experimental data at high Reynolds number, however not well at low Reynolds number. The Nusselt number was well correlated with Graetz number, and showed a transition near Gz=10. An empirical correlation proposed in the present work agreed well with the experimental data.

Frosting Heat Transfer Characteristics of Evaporators Used for Household Refrigerators According to Fin Configuration (냉장고용 증발기의 핀 형상 변화에 따른 착상 열전달 성능특성)

  • Lee, Moo-Yeon;Lee, Sang-Heon;Jung, Hae-Won;Kim, Yong-Chan;Park, Jae-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1071-1078
    • /
    • 2010
  • The objective of this study is to investigate the heat transfer characteristics of evaporators that have various fin configurations and are used in household refrigerators. The frosting and defrosting characteristics of a spirally coiled circular fin-tube evaporator, a discrete-plate fin-tube evaporator, and a continuous-plate fin-tube evaporator were measured and compared. Under non-frosting conditions, the heat transfer coefficient of the spirally coiled circular fin-tube evaporator was 22.3% and 40.2% higher than the coefficients of the discrete- and continuous-plate fin-tube evaporators, respectively. Under frosting conditions, the heat transfer coefficient of the spirally coiled circular fin-tube evaporator was 27.0% and 46.3% higher than the coefficients of the discrete- and continuous-plate fin-tube evaporators, respectively. In addition, the defrosting water amount of the spirally coiled circular fin-tube evaporator was 3.2% and 9.4% lower than the amounts in the case of the discrete- and continuous-plate fin-tube evaporators, respectively.

An Experimental Study on the Effects of Design Factors for the Performance of Fin-Tube Heat Exchanger Under Frosting Conditions (착상시 설계인자에 따른 핀-관 열교환기의 성능변화에 관한 실험적 연구)

  • 이관수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2657-2666
    • /
    • 1995
  • In this study, the effects of design factors of finned-tube heat exchanger, such as fin spacing and fin array on the frost growth and heat exchanger performance are investigated under a frosting condition. The results show that the amount of frost, frost density and blockage ratio of air flow passage increase with decreasing fin spacing. Heat transfer rate increases momentarily at the initial stage of frosting and then decreases. After that heat transfer rate continues to increase again to reach a maximum value and then decreases dramatically. It is shown that the time required for heat transfer rate to reach a maximum value becomes shorter with decreasing fin spacing, and after a maximum value, heat transfer rate decreases very fast. The maximum allowable blockage ratio is introduced to determine the operation limit of a finned-tube heat exchanger operating under frosting condition and is obtained as a function of fin spacing. It is also shown that heat transfer rate of heat exchanger with staggered fin array increases about 17% and the amount of pressure drop of air increases about 1~2 mmH$_{2}$O, compared with those of in-line type heat exchanger under frosting condition.

An Experimental Study on Evaporative Heat Transfer Characteristics in Micro-Fin Tubes Before and After Expansion Process (마이크로핀관의 확관 전후 증발열전달 특성에 관한 실험적 연구)

  • 전상희;황윤욱;윤석호;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.932-940
    • /
    • 2000
  • An experimental study on evaporative heat transfer characteristics in micro-fin tubes before and after expansion process has been performed with R-22. Single-grooved micro-fin tubes with outer diameter of 9.52 mm were used as test sections, and it was uniformly heated by applying direct current to the test tubes. Experiments were conducted at mass flow rates of 20 and 30 kg/hr. For each mass flow rate condition, evaporation temperature was set at 5 and $15^{\circ}C$and heat flux was changed from 6 to 11 kW/$m^2$ The evaporative heat transfer coefficient of micro-fin tubes after expansion is decreased because of the crush of fins and enlargement of inner diameter compared to that before expansion. Convective boiling effect decreased remarkably at higher quality range in the micro-fin tube after expansion, and the difference of the heat transfer coefficient in micro-fin tubes before and after expansion was greater for higher quality region. The evaporative heat transfer coefficient of the micro-fin tube after expansion was 19.9% smaller on the average than that before expansion.

  • PDF