• Title/Summary/Keyword: fin tube

Search Result 466, Processing Time 0.024 seconds

Development of heat exchanger for underground water heat. II - Design and manufacture for heat exchanger of underground water - (지하수 이용을 위한 열교환기 개발. II - 지하수이용 냉·난방기 설계제작 -)

  • Lee, W.Y.;Ahn, D.H.;Kim, S.C.;Park, W.P.;Kang, Y.G.;Kim, S.B.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.4 no.1
    • /
    • pp.128-137
    • /
    • 2002
  • This study was conducted to develop the heat exchanger by utilizing the heat energy of underground water(15℃), which might be used for cooling and heating system of the agricultural facilities. We developed the heat exchanger by using the parallel type plat fin tube made of Aluminum(Al 6063), which was named Aloo-Heat(No. 0247164, offered by Korean Intellectual property Office). The trial manufactures were made from Aloo-heat which was 600mm, 700mm length respectively, and It were welded to the end "U" type in order to direct flow of the underground water. The performance test was carried out under the condition of open space and room temperature with the change of flow rate of the underground water and air. The results are as follows. 1. The trial manufactures had convection heat value from 33 to 156 W/m2℃, and It was coincided with design assumption. 2. The amount of energy transfer was increased with the increment of the area of heat transfer, the air flow, the gap of temperature inlet & outlet the underground water and the air. 3. The heat value was 6,825W when the air flow was 6,000m3/h and the gap of temperature between inlet and outlet of the underground water was 6℃, and It dropped from 25.8℃ to 23.2℃(-2.6℃ difference). The convection heat value was 88.5W/m2℃. 4. The heat value was 2.625W when the air flow was 4,000m3/h and the gap of temperature between inlet and outlet the underground water was 2℃, and It dropped from 27℃ to 22.5℃(-4.5℃ difference). The convection heat value was 33.6W/m2℃. 5. Correlation values(R2) of the testing heat values of the trial manufacture type I, II, and III were 0.9141, 0.8935, and 0.9323 respectively, and correlation values(R2) of the amount of the air flow 6,000m3/h, 5,000m3/h, 4,000m3/h were 0.9513, 0.9414, and 0.9003 respectively.

Embryonic Development of Eggs, Larvae and Juveniles of the Hemitripterus villosus (삼세기 Hemitripterus villosus의 산란생태, 난발생 및 자치어의 형태발달)

  • Park, Ae-Jeon;Han, Kyeong-Ho;Lee, Sung-Hoon;Kim, Hui-Jin;Kim, Seung-Yong;Lim, In-Hyeon
    • Korean Journal of Ichthyology
    • /
    • v.26 no.1
    • /
    • pp.34-41
    • /
    • 2014
  • The present study describes the spawning ecology and early morphological development of Hemitripterus villosus. The natural spawning ground consisted of bedrock and pebbles was the intertidal coast at Taean (Chungnam) and its depth was about 5~10 m. Spawning period was mainly from the end of October to December, when the water temperature and salinity were $6.0{\sim}15.8^{\circ}C$ and mean 32.0‰, respectively. There were no difference of the body shape and color between female and male of Hemitripterus villosus, however its reproductive organs showed clear differences. The male had tube shaped genital papilla, which was connected with testis, and the female had seminal recepacle, which was the lower part of oviduct connected with ovary. Genital papilla of male came out of its body at spawning period and then male copulated. After copulation, female stored the sperm in its seminal recepacle and fertilized when it spawned. Fertilized eggs were reached 8 cells stage after fertilization at rearing water temperature $8.2{\sim}14.9^{\circ}C$. At 29 hours after fertilization, it reached morula stage, and at 146 hours after fertilization, its embryo was clearly formated. Hatching was begun from 1,488 hours (62 days) after fertilization with $8.2{\sim}14.9^{\circ}C$ water temperature. The newly hatched larvae were 12.99~15.46mm(mean $14.16{\pm}0.65$ mm) in TL (Total Length), and its mouth and anus were open. At 7 days after hatching, its yolk sac was completely absorbed and the myotomes were 15+25=40, measuring 15.23~15.54mm(mean $15.39{\pm}0.22$ mm, n=5) in TL. At 75~80 days after hatching, it was measured mean $30.06{\pm}0.76$ mm in TL, and it had reached the juvenile stage with the complete set of fin rays.

The Study of Spontaneous Developmental Abnormalities and Toxicology of Benomyl and Its Metabolite on Salamander, Hynobius leechii.

  • Park, Yong-Uk
    • Proceedings of the Korea Society of Environmental Biology Conference
    • /
    • 2005.12a
    • /
    • pp.38-45
    • /
    • 2005
  • The egg bags of Korean salamander(Hynobius leechii) were collected from farmlands in Gyeongsangnam-do area. The assumed breeding time, numerical variation of embryos in each egg bag, mortality and the rates of abnormalities were investigated. The toxicity of benomyl, the metabolite carbendazim and BIC which were frequently spread in agricultural area and caused spontaneous embryonic malformation was investigated. The assumed breeding time between the end of February and the end of March has the difference about a month because of a habitat and it takes about 2 or 3 weeks from laying eggs to hatching. The length of each egg bag and the number of embryos were very varied in each area. It is due to geographical variation. Among egg bags in total study area, only 406 of egg bags(17.70% of total egg bags) developed all of embryos to normal larvae, and 78.49% of total embryos were normally developed. The patterns of spontaneous embryonic malformation were 26 species from A to Z and the abnormal patterns in individual were 8 species and above. the geographical differences about the abnormal pattern were identified and 11 habitats categorized 4 groups. The most frequent abnormality in Gyeongsangnam-do area is the dysplasia of external gill. The caudal dysplasia, abdominal blister and dysplasia of fin were also frequently observed. Individuals showing severe external defect were histologically studied and they showed retinal hypo-pigmentation, thyroid carcinoma, somatic muscular dysplasia, degeneration of cephalic neuron and various organ dysplasia. Benomyl and carbendazim were treated by 10pM$^{\sim}$10uM and BIC was treated by 1$^{\sim}$40ppm to know the effect of toxicity about toxic substance of salamander. After benomyl was treated, a survival rate was sharply dropped from 2 to 8 days. $LC_{100}$ identified in $1{\mu}M$, $LC_{50}$ identified between 100nM and $1{\mu}M$. $EC_{50}$ was assumed between 10nM and 100nM. The prevalent external malformation was abdomen swelled abnormally and histo-pathological effects were abdomen, neural tube and lens hernia. This suggests that benomyl is the toxicitic substance which inhibits the development of digestive system and nervous system. The result of treated carbendazim was similar to that of the treated benomyl. The survival rate is sharply dropped between 2 and 6 days. $LC_{100}$ was identified $1{\mu}M$ and $LC_{50}$ was identified between 10nM and 100nM. This shows that cabendazim has stronger lethal toxicity than benomyl. Ventral blister, eye dysplasia and cephalic dysplasia in the individual of external malformation mean that cabendazim affected nervous system much more than benomyl. Because the toxicity of BIC affected less in the beginning but affected more in the near hatching period, the period causing toxicity is somewhat different. $LC_{100}$ identified near 40ppm and $LC_{50}$ identified near 25ppm. The external defect shows mainly ventral blister and histo-pathological results show intestinal deformities. This result suggests the BIC inhibited strongly the development of digestive system. These abnormal developments may be caused by antimitotic action, inhibition of tubulin complex, destruction of microtubule, inhibitions of neurulation and closing of neural fold, and by the inhibition of movement of neural crest cells of benomyl. These abnormal developments may be caused by the rupture of epithelium, the loss of microtubule, the reduction of spindle size, the inhibition of spindle assembly formation, the destruction of spindle poles of carbendazim. These abnormal developments may be caused cytotoxicity by inhibition of the synthesis of a number of macromolecules and similar reaction the inhibition of benomyl.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008 (설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.

Recent Progress in Air Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2007 (설비공학 분야의 최근 연구 동향 : 2007년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.844-861
    • /
    • 2008
  • The papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during the year of 2007 have been reviewed. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro nano fluid, micropump and fuel cell. Traditional CFD was still popular and widely used in research and development. Studies about fans and pumps were performed in the field of fluid machinery. Characteristics of flow and fin shape optimization are studied in the field of piping system. (2) The research works on heat transfer have been reviewed in the field of heat transfer characteristics, heat exchangers, and desiccant cooling systems. The research on heat transfer characteristics includes thermal transport in pulse tubes, high temperature superconductors, ground heat exchangers, fuel cell stacks and ice slurry systems. For the heat 'exchangers, the research on pin-tube heat exchanger, plate heat exchanger, condensers and gas coolers has been cordially implemented. The research works on heat transfer augmenting tubes have been also reported. For the desiccant cooling systems, the studies on the design and operating conditions for desiccant rotors as well as performance index are noticeable. (3) In the field of refrigeration, many papers were presented on the air conditioning system using CO2 as a refrigerant. The issues on the two-stage compression, the oil selection, and the appropriate oil charge were treated. The subjects of alternative refrigerants were also studied steadily. Hydrocarbons, DME and their mixtures were considered and various heat transfer correlations were proposed. (4) Research papers have been reviewed in the field of building facilities by grouping into the researches on heat and cold sources, air conditioning and air cleaning, ventilation and fire research including tunnel ventilation, flow control of piping system, and sound research with drain system. Main focuses have been addressed to the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies were mostly focused on analyzing the indoor environment in various spaces like cars, old tombs, machine rooms, and etc. in an architectural environmental field. Moreover, subjects of various fields such as the evaluation of noise, thermal environment, indoor air quality and development of energy analysis program were researched by various methods of survey, simulation, and field experiment.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 - (공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF