• Title/Summary/Keyword: filtration performance

Search Result 378, Processing Time 0.025 seconds

Porous polymer membranes used for wastewater treatment

  • Melita, Larisa;Gumrah, Fevzi;Amareanu, Marin
    • Membrane and Water Treatment
    • /
    • v.5 no.2
    • /
    • pp.147-170
    • /
    • 2014
  • This paper focuses on the study of the most recent ultra-filtration techniques, based on porous polymer membranes, used for the treatment of wastewater from oil, mine and hydrometallurgical industries. The performance of porous membranes used in separation and recovery of oil and heavy metals from wastewater, was evaluated by the polymer composition and by the membrane characteristics, as it follows: hydrophobicity or hydrophilicity, porosity, carrier (composition and concentration), selectivity, fouling, durability, separation efficiency and operating conditions. The oil/water efficient separation was observed on ultra-filtration (UF) techniques, with porous membranes, whereas heavy metals recovery from wastewater was observed using porous membranes with carrier. It can be concluded, that in the ultra-filtration wastewater treatments, a hybrid system, with porous polymer membranes with or without carrier, can be used for these two applications: oil/water separation and heavy metals recovery.

연속공정에 의한 UF용 폴리이미드 분리막의 제조

  • 김완주;전종영;탁태문
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.04a
    • /
    • pp.45-45
    • /
    • 1995
  • Filtration, one of the most important process in the various industrials, is defined as the separation of two or more compounds from a fluid by passing the mixture refers to the separation of solid, immisible particles from liquid or gaseous mixture. Membrane filtration which is a type of filtration extends it's application further to include the separation, concentration, and filtration. The main objective of this investigation is the preparation of organic solvents-resistant polyimide membranes by using phase inversion technique and their application as a UF membrane. Specially, the dope solution was prepared from the newly developed method. The newly developed method is that the dope solution was directly prepared from the polyimide solution which was prepared by the modified one-step polymerization. The effects of the parameters for membrane preparation such as the casting solution composition and the casting conditions were investigated and the performance and chemical stabfiity of membrane are going to be tested.

  • PDF

Empirical modelling of chemically enhanced backwash during ultrafiltration process

  • Daramola, M.O.;Adeogun, A.G.
    • Membrane and Water Treatment
    • /
    • v.2 no.4
    • /
    • pp.225-237
    • /
    • 2011
  • In this study, response of reversibility of membrane flux during chemically enhanced backwash (CEB) to changes in filtration time, filtration flux and coagulant concentration dosing during ultrafiltration (UF) process was investigated using a regression model. The model was developed via empirical modelling approach using response surface methodology. In developing the model, statistically designed UF experiments were conducted and the results compared with the model output. The results showed that the performance of CEB, evaluated in terms of the reversibility of the membrane flux, depends strongly on the changes in coagulant concentration dosage and the filtration flux. Also the response of the reversibility of membrane flux during CEB is independent of the filtration time. The variance ratio, VR << $F_{value}$ and $R^2$ = 0.98 obtained from the cross-validation experiments indicate perfect agreement of the model output with experimental results and also testify to the validity and suitability of the model to predict reversibility of the membrane flux during CEB in UF operation.

A Study on the Effect of Dust Precharging on Filtration Performance

  • Park, Y.O;Park, S.J.;Lee, J.H.;Kim, S.D.;Park, H.S.;Park, H.K.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E2
    • /
    • pp.53-59
    • /
    • 2001
  • A hybrid dust-collector combining electrostatic charging with fabric filtration method was developed, and its performance characteristics were evaluated in this study. Charged particles build porous dendritic structure on the surfaces of filter by electrostatic attraction, increasing the collection efficiency of dust particles and reducing the pressure drop through the deposited dust layer and filter media. The cleaning performance of the dust layer is improved because the dendritic structured dust layer can be removed more easily by pulse jet cleaning flow. The results of the experiment showed a reduction of fine particle emission of 37% and the energy saving of 13% by precharging dust particles before filtration.

  • PDF

Sludge Thickening Performance of the Filtration Bio-reactor Equipped with Shadow Mask Filter Module (Shadow mask 여과 모듈을 이용한 슬러지 농축 특성)

  • Jung, Yong-Jun;Kwon, Koo-Ho;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.29-33
    • /
    • 2005
  • In order to recycle the waste material and to develop the thickening unit of waste activated sludge from wastewater treatment facilities, the filtration bio-reactor equipped with a shadow mask filter module was employed for this work from which the operating properties and parameters were drawn. The sludge thickening and filtration unit is made of cylindrical acryl tank(12cm i.d. ${\times}$ 58cm height: working volume of 6L), where the flat-sheet type of shadow mask filter module(pore size: 220~250um, opening area: 34.8~39.6%) was installed and the effluent was withdrawn from the effluent port at the lowest point of the reactor, and the filtration was performed only by the hydraulic pressure. For evaluating the operating performance of this reactor, some parameters such as the solid-liquid separation of different biomass concentrations, the water quality of filtrate, the aeration cleaning time and the cleaning effect were investigated. Depending on the MLSS concentrations, the different time to withdraw 3L of filtrate was required in which the longer filtration time was necessary for the higher MLSS concentrations caused by the thicker formation of cake layer: 40 minutes for 5,000 mg/L, 70 minutes for 10,000 mg/L and 100 minutes for 15,000 mg/L, where the concentrations of SS were 8.9, 6.7 and 6.5 mg/L, respectively. Under the same operating conditions (the intensity of aeration cleaning: 80 L/min, MLSS: 10,000 mg/L), the proper aeration cleaning time was revealed 30 seconds, and the stable formation of cake layer was in the range of 10 to 15 minutes. Therefore, the shadow mask considered as a waste material can be of use as a filter material for the sludge thickening system.

Performance Test of Air Filter Media (필터여재의 성능평가)

  • Ahn, K.H.;Bae, G.N.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.417-426
    • /
    • 1994
  • Filter media performance was evaluated using monodisperse NaCl particles with Differential Mobility Analyzer and Ultrafine Condensation Particle Counter. Low or medium performance filters show that the most penetrating particles size(MPPS) is around $0.3{\mu}m$ in diameter and is shifted to smaller sizes as the filter face velocity increases. However, HEPA and ULPA filters show MPPS is around $0.15{\mu}m$ in diameter and is also shifted to $0.1{\mu}m$ in diameter as the face velocity increases. In case of electret filter, the MPPS is found around $0.04{\mu}m$ region for Boltzmann charge equilibrium particles. There is a tendency of strong collection efficiency decrease for large particles as the face velocity increases on the contrary to the other filters. One of the medium performance filter efficiency was compared with filtration theory and the good agreetment was found in the experimental range.

  • PDF

A Pilot Study for Introducing Advanced Water Treatment Facilities at Nakdong River (낙동강수계 고도정수시설 도입을 위한 PILOT 실험 연구)

  • Oh, Se-Won;Choi, Kwong-Ho;Choi, Soo-Il;Son, Seong-Sup
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.88-98
    • /
    • 1997
  • To obtain design and operating parameters for advanced water facilities, pilot test consisted of ozonation and GAC filtration was conducted at midstream of Nakdong River. Even though the concentrations were very low, 62 chemicals were detected above $0.005{\mu}g/L$ in raw water. In the preozonation, natural organic matters which could produce THMs and organics such as phenols and amines were effectively removed. The performance of TOC removal of GAC filtration with ozonation was better than GAC filtration alone and adsorption capacity of GAC adsorbers were ranged 3~6mg-TOC/g-carbon. And also the life of GAC adsorber for removing TOC was predicted more than 1 years if ozonation is introduced. This indicates that biological degradation of organics happened in GAC filters. Most organics detected at ppt level were removed below detection limit by GAC filtration with ozonation. These results show that ozonation and GAC filtration are the reliable and safe process for organic contaminants and chlorinated byproducts control at Nakdong River.

  • PDF

Evaluation of Filtration Efficiency and Inhalation Airflow Resistance of Uncertified Masks in Asian Countries

  • Sohyun Kang;Soomin Kim;Ji Soo Kim;Gayoung Lee;Annisa Utami Rauf;Kraichat Tantrakarnapa;Shih-Chun Candice Lung;Kiyoung Lee
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.4
    • /
    • pp.267-273
    • /
    • 2024
  • Background: During the coronavirus pandemic, masks played a critical role in preventing respiratory infections. While the performance of masks such as KF-certified masks and N95 masks was evaluated and managed by the authorities, the performance of common masks was not. Objectives: This study aimed to evaluate the performance of uncertified masks in four Asian countries against certification standards (Korean KF80, KF94, and US N95). Methods: Thirty uncertified mask products from Indonesia, 20 from South Korea, 26 from Taiwan, and 30 from Thailand were purchased to perform performance evaluations. The uncertified masks included disposable dental masks, cloth masks, and children's masks. Filtration efficiency and inhalation airflow resistance tests were conducted according to Korean KF80, KF94, and US N95 protocols. Results: None of the 106 identified masks complied with the KF94 standard. A few complied with the KF80 standard: four from Indonesia, four from South Korea, 13 from Taiwan, and 16 from Thailand. Some of the masks met the N95 standard: one from Indonesia, three from South Korea, two from Taiwan, and one from Thailand. Conclusions: Since many uncertified masks did not comply with performance standards, wearing them might not have provided sufficient protection. Performance of uncertified masks could provide critical information for next pandemic management.

The Effect on Treatment Performance of Fiber Filter Under Various Packing-Density and Filtration Velocity (충진밀도와 여과속도가 섬유사 여과기의 처리 성능에 미치는 영향)

  • Im, Jeong-Hoon;Kim, Hyo-Kwan;Lee, Jung-June;Moon, Tae-Sup;Jeong, Min-Ki;Woo, Hae-Jin;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.216-222
    • /
    • 2006
  • A flexile fiber filter developed in Korea was operated to evaluate the effect of packing density and filtration velocity on particle removal. The pilot-scale fiber filter with 40 cm of diameter and 2 m of height was packed with polyamide fibers of which mean diameter was approximately 0.93 mm. While the filtration velocity was maintained at 325 m/hr, the particle removal efficiency was compared with various of packing density from $70kg/m^3\;to\;100kg/m^3$. On the contrary, when the packing density was maintained at $70kg/m^3$, the particle removal efficiency was examined with various filtration velocity from 65 m/hr to 400 m/hr. The filtration pressure increased with the packing-density increase. Below $80kg/m^3$ of packing density, the removal efficiencies of turbidity ad SS were less than 30% and 50%, respectively. At $100kg/m^3$ of packing density, the removal efficiencies of them were nearly 45% and 60% respectively. The filtration pressure increased with the filtration-velocity increase. A better removal efficiency was obtained at a lower filtration velocity, removal efficiency of them were 73% at 65 m/hr. Consequently, The filtration velocity was the more important factor to enhance the particle removal efficiency compared with the packing density in fiber filter.

A study on the evaluation of field application for the waterproofing or corrosion proof construction method, as coating high quality filtration plant with ozone resistance paints of phenol degeneration polyamine (페놀 변성 폴리아민계 내오존도료를 이용한 고도정수처리장의 방수$\cdot$방식 공법에 대한 현장 적용성 평가에 관한 연구)

  • Jung Mun-Jung;Kwon Shi-Won;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.33-38
    • /
    • 2005
  • It is applied in the high quality equipment construction by introduction of this high duality treating technology (ozone treating, activated carbon treating, high quality oxidation treating, UV treating etc.)waterproofing or corrosion proof method caused secondary economy damage of operation discontinuance and high quality treating equipment for applying existent waterproofing method that corrosion proof ability (ozone resistance performance, chemical resistance etc.) and abrasion resistance performance by comprehension insufficiency of user and designer. Therefor, In this study, we will analyze problem of waterproofing and corrosion material of existing construction application by high quality treating, and measure physical performance change by various condition. It is required to waterproofing and corrosion system and application of the field valuation.

  • PDF