• 제목/요약/키워드: filtration equipment

검색결과 64건 처리시간 0.021초

Application of Neural Inverse Modeling Scheme to Optimal Parameter Tuning of Filter Test Equipment

  • Kim, Sung-Ho;Han, Yun-Jong;Bae, Geum-Dong
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제4권2호
    • /
    • pp.172-175
    • /
    • 2004
  • Generally, the yield rate of semiconductors is the major factor that affects directly the price of semiconductors. For a high yield rate of semiconductors, the air inside clean room is needed to be purified and high efficient filters are used for this. The filter are made of super-fine fiber and certain pinholes can be easily produced on the filter's surface by inadvertent manufacturing. As these pinholes are not easily detected with the bare sight, these pinholes exert a negative impact to filtration performance of the filter. In this research, not only the automatic test equipment for detecting pinholes is proposed, but also inverse modeling scheme based on artificial neural network is applied for tuning of its important parameters.

소형 자동차 페인트 도장부스에서 발생하는 점착성 paint aerosol 처리장치에서 제거성능 (Removal Performance of Sticky Paint Aerosol Control System Generated from Small Scale Car Paint Overspray Booth)

  • 이재랑;;전성민;이강산;손종렬;박영옥
    • 한국대기환경학회지
    • /
    • 제31권1호
    • /
    • pp.54-62
    • /
    • 2015
  • Small scale paint overspray booths are being operated nationwidely, for repair of passenger car body parts. paint aerosols are emitted from the paint overspray booth in operations. In paint overspray booth operations without ventilation system and air pollutants collection unit, it may land on nearby equipment. In this study a removal of sticky paint aerosol for application of the small-scale overspray paint booth. it's cause the surface of filter bag from generated sticky paint aerosol. To remove adhesion of paint aerosol the agglomerating agents are injected and mixed with sticky paint aerosols prior to reach the filter bag. The paint spray rate was set as $10{\pm}5g/min$ from air-atomized spray guns in the spray booth, injection rate of agglomerating was $10{\pm}5g/min$ in the mixing chamber. The filtration velocity including air pollutants varied from 0.2 m/min to 0.4 m/min. Bag cleaning air pressure was set as $5.0kg_f/min$ for detaching dust cake from surface of filter bag. Bag cleaning interval at the filtration velocity of 0.2 m/min was around 3 times longer than that of the 0.4 m/min. The residual pressure drop maintained highest value at the highest filtration velocity. Fractional efficiency of 99.952%~99.971% was possible to maintain for the particle size of 2.5 microns. Total collection efficiency at the filtration velocity of 0.2 m/min was 99.42%. During this study we could confirm high collection efficiency and long cleaning intervals for the test with filtration velocity of 0.2 m/min indicating an optimal value for the given dimensions of the test unit and test operating conditions.

동적 신장 신티그래피 검사 시 사용되는 Gates 법과 Modified Gates 법의 사구체 여과율 비교에 관한 고찰 (A Study on Glomerular Filtration Rate Comparisons between Gates Method and Modified Gates Method used in Dynamic Renal Scintigraphy)

  • 함준철;반영각;박민수;조석원;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.96-101
    • /
    • 2012
  • 사구체 여과율은 신기능의 평가 및 신 질환의 조기 발견 및 만성 신 질환 환자의 경과 관찰에 중요한 지표가 된다. 본 연구에서는 동적 신장 신티그래피의 Gates법과 Modified Gates법을 채혈을 이용한 MDRD법 공식을 기준으로 그 차이를 비교, 분석하고자 한다. 2010년 11월부터 2011년 8월까지 본원에 내원하여 신장 신티그래피 검사를 시행한 45명의 환자를 대상으로 시행하였다. 이 중 20명의 환자는 AGUS(Philips Medical System, Cleveland, OH, USA) 장비의 Gates법과 MDRD법(Modification of Diet Renal Disease) 공식에 의한 사구체 여과율 값을 비교하였으며, 20명의 환자는 INFINIA (General Electric Healthcare, Wisconsin, MI, USA) 장비의 Modified Gates법과 MDRD법 공식에 의한 사구체 여과율 값을 비교하였다. 마지막으로 경과 관찰 시 MDRD법 공식에 의한 사구체 여과율 변화가 없는 환자 5명을 대상으로 Gates법과 Modified Gates법을 비교하였다. Gates법과 Modified Gates법 모두 MDRD법 공식에 의한 사구체 여과율 값과 높은 상관 관계를 보였으며($p$<0.01, r=0.903, r=0.867), Gates법의 대응 차 평균은 $2.05{\pm}2.54mL/min/1.73m^2$로 나타났고, Modified Gates법의 대응 차 평균은 $25.2{\pm}3.71mL/min/1.73m^2$로 나타났다. 마지막으로 5명의 환자에서 실시된 Gates법과 Modified Gates법의 비교는 높은 상관 관계를 보였으며($p$<0.05, r=0.949), 대응 차 평균은 $20.4{\pm}8.84mL/min/1.73m^2$ 로 나타났다. Gates법과 Modified Gates법 및 MDRD법 공식에 의한 사구체 여과율 값은 서로 높은 상관 관계를 보였다. 동적 신장 신티그래피 검사 시 사용되는 Gates법과 Modified Gates법의 상관 관계를 인지하고 검사를 진행 한다면, 진단능을 향상시켜 정확한 신기능의 평가가 이루어질 것으로 사료된다.

  • PDF

소화슬러지의 비저항계수(SRF)와 모세관흡입시간(CST)의 상호관계식 유도 및 비교 (Coupling Equation of Specific Resistance to Filtration(SRF) and Capillary Suction Time(CST) of Digested Sewage Sludge)

  • 김지형;나승민;박지호;김영욱
    • 한국산학기술학회논문지
    • /
    • 제8권4호
    • /
    • pp.874-880
    • /
    • 2007
  • CST와 SRF는 슬러지 탈수효율 인자로 가장 널리 사용되고 있다. 이러한 CST와 SRF는 각각의 분석특징의 장.단점으로 인해 실험방법 및 결과 해석시, 슬러지 탈수의 최적조건을 찾아 예측하는데 어려움이 있다. 따라서 본 연구는 탈수성 지표로 이용되는 CST와 SRF의 이론식 가운데 CST와 SRF의 상호관계식을 유도하여 각각의 실측값과 예측값을 비교한 후 비교적 측정이 간편한 CST 시험만으로도 탈수최적조건을 도출할 수 있는 이론식을 검토하였다.

  • PDF

솔더 스크랩의 재생을 위한 전처리 공정 (Pretreatment Process for the Reuse of Solder Scrap)

  • 정우광;김병수;이재천
    • 한국재료학회지
    • /
    • 제21권12호
    • /
    • pp.673-678
    • /
    • 2011
  • With an increased production of Printed Circuit Boards (PCBs) in electronic equipment, the consumption of solder alloys is growing globally. Recently, increasing importance of recycling solder scrap has been recognized. Generally, solder scrap contains many impurities such as plastics and other metals. Hazardous components must be eliminated for recycling solder scrap. The present work studied pretreatment for reuse of solder scrap alloys. An experiment was conducted to enhance the cleanliness of solder scrap melt and eliminate impurities, especially lead. Physical separation with sieving and magnetic force was made along with pyrometallurgical methods. A small decrease in lead concentration was found by high temperature treatment of solder scrap melt. The impurities were removed by filtration of the solder scrap melt, which resulted in improvement of the melt cleanliness. A very low concentration of lead was achieved by a zone melting treatment with repeated passage. This study reports on a pretreatment process for the reuse of solder scrap that is lead free.

입자상물질과 VOCs 동시제거 실증장치에서 자동차 페인트 부스 발생 paint aerosol과 VOCs의 동시제거 성능 특성 (Performance characteristics of simultaneous removal equipment for paint particulate matter and VOCs generated from a spraying paint booth)

  • 이재랑;;전성민;이강산;김광득;박영옥
    • 한국입자에어로졸학회지
    • /
    • 제12권4호
    • /
    • pp.161-168
    • /
    • 2016
  • The purpose of this study is to determine the performance characteristics of the paint particulate and volatile organic compounds(VOCs) simultaneous removal from the spraying paint booth in the laboratory and real site by sticky paint particulate and VOCs simultaneous removal demonstration unit. The sticky paint particulate and VOCs simultaneous removal unit is composed of the horizontal type pleated filter modules and the zig-zag type granular activated carbon packing modules. The test conditions at the laboratory are $50.15g/m^3$ of average paint aerosol concentration and 300 ppm of VOCs concentration which were same as the working conditions of spraying paint booth in the real site. But, the demonstration conditions at the real site are varied according to the working condition of spraying paint booth for the kind of passenger car bodies. The test results at the laboratory obtained that 99% of total particulate collection efficiency at 0.62 m/min of filtration velocity and 84% at 1.77 m/min of filtration velocity. The VOCs removal efficiencies are 97% at $3500hr^{-1}$ of gas hour space velocity and 59% at $10,000hr^{-1}$ of gas hour space velocity. In the real site test, the average removal efficiency of PM10 was measured to be 99.65%, the average removal efficiency of PM2.5 was 99.38%, the average removal efficiency of PM1 was 98.52%, and the average removal efficiency of VOCs was 89%.

진단용엑스선촬영장치의 간접 선량 계산법 개발 (Development of Indirect Dosimetry by Calculation Method in the Diagnostic X-ray Equipment)

  • 김정수;김성환;전민철;주원하;정민규;김미정;이승열;이태희;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.587-594
    • /
    • 2018
  • The purpose of this study was to develop the indirect dosimetry by calculation (IDC) method for diagnostic X-ray equipment. The experiments were performed with inverter type X-ray tubes: Toshiba (E7252X, Japan) and Varian (RAD-14, USA). For the development method, we first applied the standard quality of X-ray beam shown in the TRS457 document, and second, to produce the constants of trendline for the IDC, the total filtration on X-ray beam was subdivided. Third, in order to increase the precision, the energy region was divided into the high energy region and the low energy region and developed by the IDC. In order to verify the IDC, mean dose (mR) values were measured for three Toshiba X-ray tubes and three Varian X-ray tubes at clinical medical institutions and then compared with the IDC on the 2013. As a result, compared with the previous study, the accuracy of the IDC of this study were improved by 2.71% and 9.91% in Toshiba and Varian X-ray tubes, respectively.

진동막분리장치에 의한 반도체폐수처리와 재이용에 관한 연구 (A Study on the Semiconductor Wastewater Treatment and Recycling by VSEP system)

  • 강경환
    • 한국환경과학회지
    • /
    • 제14권3호
    • /
    • pp.335-343
    • /
    • 2005
  • The objective of this research is to evaluate a feasibility of wastewater reuse by membrane treatment with vibrating membrane separation equipment. Molecular weight of compounds in wastewater, permeability of membrane and retentate characterization after membrane filtration were investigated in order to determine appropriate membrane pore size and materials for wastewater treatment. Selected membrane was evaluated with vibration membrane separation equipment to optimize operating conditions. The following conclusion are drawn. 1. We got as following test results after the distribution of particles in the semiconductor wastewater, are made up of $1\~20{\mu}m$. Si, gold and Al in turn are contained in semiconductor wastewater. 2. Recovery rate is changeless under increasing recovery rate in operation. Though a value can be if pressure can be changed, the highest value of permeate rate is presented in 150 psi. 3. The AS-100(polysulpone) was selected as the most appropriate membranes for the treatment of semi-conductor wastewater to VSEP system. The fouling almost did not occur during this experiments. The analyses of treated water with VSEP system showed conductivity: 0.059,us/cm, TDS: 40mg/l, COD: 20mg/l, SS : 5mg/l, n-Hexane: 8.3mg/l. Comparing previous systems, operating expenses is decreased by more $50\%$.

PFC 제염 후 발생된 제염폐액 내 오염입자의 제거 (The Separation of Particulate within PFC Decontamination Wastewater Generated by PFC Decontamination)

  • 김계남;이성열;원휘준;정종헌;오원진;박진호
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2005년도 춘계 학술대회
    • /
    • pp.32-39
    • /
    • 2005
  • 원자력연구시설의 핫셀 내 바닥이나 장치표면에 부착된 방사성 오염입자의 제거를 위해서 PFC 제염기술을 적용한다. 고가인 PFC 제염용액의 재사용을 위해서는 여과장치의 개발이 필요하고 제염종료 후 이차폐기물의 양을 최소화할 필요가 있다. 여과막을 이용한 입자의 제거효율 측면에서 보면 Ceramic, PVDF, PP 막 모두가 $95\%$ 이상의 높은 여과 성능을 보였다. 기공 크기가 같은 동일 여과막에서는 입자가 크거나 공급되는 압력이 높을수록 좀더 성공적인 입자의 제거효율을 나타내었다. 투과 성능은 PVDF 막이 가장 높은 수준을 나타내었고 Ceramic과 PP 막에서는 다소 낮은 성능을 보였다. PVDF 막은 낮은 압력과 짧은 여과시간으로 최대(한계) 투과량에 도달함을 확인하였다. Ceramic 막은 모의입자의 제거효율은 높지만 다소 낮은 투과 성능을 나타냈다. 또한, 막 자체의 비싼 가격과 쉽게 부서지는 성질의 단점을 지니고 있지만 무기화합물의 재질로 되어있기 때문에 알파방사능 환경에서 $H_2$ 가스를 발생하는 고분자 막인 PVDF, PP 막과 비교하여 훨씬 안정적이므로 실제 핫셀에 적용 가능함을 알 수 있었다.

  • PDF

A Study of the Technical Treatment within an Environmental Appetency for the Ballast Water

  • Nam, Chung-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권8호
    • /
    • pp.1313-1323
    • /
    • 2004
  • In accordance with adoption of new convention for the control of ship's ballast water at the diplomatic conference held in London Feb, 2004, every country has to regulate the ballast water and deposit matters. When this Resolution comes into effect in 2009, all vessels engaged in international voyage must have ballast water control program, ballast water records, equipments which are suitable to the standard of exchange and performance for the ballast water. This study estimates objectively their performances, merits and demerits of the ballast water treatment technique and exchanging techniques for safe operation of ships. It is desirable to design an equipment to control the ballast water using the brush-type vacuum suction nonstop reverse cleaning system to overcome the clogging phenomenon and the direct disc filtering to maximize filtering area for the optimum process considering biological availabilities. It will be expected to protect against marine pollution and to maintain clean sea if it is secured to develop new ballast water treatment techniques. And it will also be expected to cope with the Resolution and each regulation of the developed countries from the ballast water.