• 제목/요약/키워드: filtration efficiency

검색결과 513건 처리시간 0.029초

세라믹 섬유필터를 이용한 디젤 입자상물질 배출저감에 관한 기초연구 (A Study on the Exhaust Reduction of Diesel Particulates Using Ceramic Fiber Filters)

  • 주용남;홍민선;문수호;이동섭;임우택
    • 한국대기환경학회지
    • /
    • 제19권3호
    • /
    • pp.297-306
    • /
    • 2003
  • Works were focused on back pressure characteristics of ceramic fiber filter on DPF (Diesel Particulate Filter) system and experiments were performed to select appropriate filter which can filter particulates. Filters were installed on metal -support tube which has openings for exhaust gas flow. Ceramic fiber filters with high specific surface area and adequate high temperature strength are commercially available for filtration of diesel particulates and in -situ hot regeneration. Thus, ceramic blanket and ceramic board which are used as insulating media were applied to filter and filtration apparatus was installed on exhaust gas line connected to 2.0 L diesel engine. Alternating filter structure to adapt DPF system, collection efficiency test of diesel particulates was measured. In case of ceramic blanket, pressure drop was low, caused by the destruction of soft structures. Also, particulate collection efficiency was decreased depending on loading time. In case of ceramic board, structure design was altered to reduce back pressure on DPF system. Structure design was altered to induce Z-flow by making 10 mm and 5 mm holes on the surface of media. Alteration of 5 mm hole showed that media have low back pressure but particulate collection efficiency was 77%, while 10 mm hole showed that of 90%.

$MIEX^{(R)}$+응집공정을 이용한 한외여과 공정의 최적화 : 다양한 전처리 공정의 적용에 따른 막 오염 현상 규명 (Optimization of Ultrafiltration Process using $MIEX^{(R)}$+Coagulation Process)

  • 손희종;황영도;노재순;정철우;강임석
    • 대한환경공학회지
    • /
    • 제27권7호
    • /
    • pp.753-761
    • /
    • 2005
  • 전처리 공정에 따른 투과 flux 변화를 살펴보면 $MIEX^{(R)}$+UF 공정의 경우 응집+UF 공정에 비하여 높은 유기물 제거율을 나타내었으나 투과 flux 감소는 크게 나타났다. 따라서, 막 오염을 자세하게 규명하기 위하여 sequential filtration 실험결과 막 오염물질은 고분자 유기물질로 나타났으며, DOC 0.5 mg/L 이하의 유기물질이 막 오염 유발물질로 작용하고 있었다. 10 kDa 이하의 저분자 유기물질들은 $MIEX^{(R)}$ 처리에 의해 제거가 용이하여 막 표면에서 유기물 부하를 감소시켜 이로 인해 응집+UF공정에 비하여 투과 flux 감소율이 낮게 나타났다. $MIEX^{(R)}$+UF공정은 입자상 물질의 존재 유무에 관계없이 flux 감소율은 거의 유사한 경향을 보였으나 응집+UF공정은 용존성 유기물질만이 존재하는 시수에 비하여 입자상 물질이 존재하는 경우에 투과 flux 감소가 더 낮게 나타났다.

Fe 첨가제를 적용한 금속분말 필터의 포집 및 재생 특성에 관한 연구 (A Study on the Performance of the Diesel Particulate Filter made of Porous Metal with Fe-based Fuel Additive)

  • 박상현;전광민;조규백;정용일;박용렬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.802-806
    • /
    • 2001
  • Diesel particulate trap is the most reliable system to reduce the particulate matters from diesel engine. Filter is the core component of DPF and ceramic monolith type is dominantly used, which is expensive and fragile relatively at thermal shock. Porous metal filter, which has superior thermal characteristics and low cost, was tested in order to analyze the regeneration performance by using with ferrocene additive. This filter showed the 72% filtration efficiency, additives itself diminished 48% of PM from engine out emission, and final PM reduction ratio of 89% was achieved by DPF system with D-13 test mode.

  • PDF

상향류 및 하향류 생물막여과공정의 처리특성에 관한 연구 (Treatment Characteristics of Biological Aerated Filter Process Using the Upflow and Downflow System)

  • 이양규;김건협
    • 상하수도학회지
    • /
    • 제20권6호
    • /
    • pp.837-848
    • /
    • 2006
  • This paper presents the test results of biological aerated filtration(BAF) process to replace activated sludge process by enhancing treated effluent quality and reducing the costs. In BAF process both BOD and SS compounds in wastewater are degraded and removed by biological reaction and filtration. Upflow BAF with expanded polypropylene media and downflow BAF with ceramic media were used to investigate the effects of hydraulic and organic loads on effluent quality. As a result, in BAF processes which has different media, upflow BAF reactor shows 5% higher efficiency than downflow BAF and this phenomena caused by backwashing methods and operational conditions. The results of influence factors analyzed by Factor Analysis Method in BOD and SS treatment efficiency are the size of media, hight of media bed and type of media. The quantitative effects of media size are 5.73% in TBOD, 5.78% in SBOD and 7.65% in TSS, so we confirmed the main factor is media size.

철염계 응집제를 사용한 전응집침전, 전염소처리와 PVDF 재질의 정밀여과 막을 조합한 막 여과 정수처리시스템 평가에 관한 연구 (Performance Evaluation of MF Membrane Filtration Pilot System Associated with Pre Coagulation-Sedimentation with Iron-Based Coagulant and Chlorination Treatment)

  • 이상협;장낙용;와타나베 요시마사;최용수
    • 상하수도학회지
    • /
    • 제18권5호
    • /
    • pp.588-597
    • /
    • 2004
  • In this research, we investigated the variation of transmembrane pressure and permeate water quality with pre coagulation and sedimentation with iron based coagulant and chlorination of feed water for PVDF (polyvinylidene fluoride) based MF membrane filtration. NaCIO was fed to the membrane module with dosage of 0.5mg/L and maintained during filtration. To observe the effect of raw water, three types of raw and processed waters, including river surface water, coagulated water and coagulated-settled water, were applied. In case of river surface water, the transmembrane pressure increased drastically in 500 hours of operation. On the contrary, no significant increase in transmembrane pressure was observed for 1,200 hours of operation for coagulated water and coagulated-settled waters. The turbidity of permeate was lower than a detection limit of equipment for all raw waters. The removal efficiency of humic substances of coagulated water and coagulated-settled water was approximate ten times of that of surface river water. And, the removal efficiency of TOC and DOC was approximate two times of that of surface river water. From the results of plant operation, stable operation was maintained at $0.9m^3/m^2{\cdot}day$ filtration flux through the combination of pre-coagulation and pre-chlorination. However, the water quality of permeate was the best when pre-coagulation-sedimentation process was combined with pre-chlorination.

Usable water production from coal seam gas water with a combination of pore control fiber filtration and reverse osmosis

  • Shin, Choon Hwan;Bae, Jun Seok
    • Environmental Engineering Research
    • /
    • 제23권2호
    • /
    • pp.210-215
    • /
    • 2018
  • Coal seam gas (CSG) water, to be discharged, has been usually treated in reverse osmosis (RO) plants which require extensive and expensive pre-treatment. However, current low gas prices have been a great driver for relevant industries to seek for alternative cost-effective technologies in the aspect of its beneficial use and fit-for-purpose usable water production. In this paper, a combined system with a two-stage pore control fiber (PCF) filtration and a RO system was designed and tested for CSG water treatment. Also, a coagulation reactor was placed in front of the PCF to further enhance suspended solid removal. More than 99% of SS were removed through the PCF filtration while organic, total nitrogen and total phosphorous were mostly removed by the RO system. Especially along with a decrease in conductivity, the total dissolved solid derived from salts was mainly removed in the RO system. Having $OH^-$ undetected, $HCO_3{^-}$ was found to be a dominant compound and its removal efficiency was 97-98% after the RO treatment. And a Fe(III) type of Polytetsu, which was the first to be tested in this paper, was found to be a better option than a Al(III) type of Poly Aluminium Chloride due to its greater coagulation efficiency and applicability at a broader range of pH than the Al(III) type. In addition, there was no noticeable change in oxidation reduction potential, suggesting that an additional process is required to oxidize non-ionic organic carbons (detected as total organic carbon).

전기응집 조건이 활성슬러지 막 여과 저항에 미치는 영향 (Effect of operating condition of electro-coagulation on the membrane filtration resistances of activated sludge)

  • 홍성준;장인성
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.2314-2320
    • /
    • 2015
  • MBR (Membrane Bio-Reactor) 공정은 막 오염을 해결하기 위해 막대한 에너지 소비를 하는 공정으로 알려져 있다. 이를 해결하기 위한 일환으로 전기응집 기술을 MBR에 적용하는 시도가 보고되고 있다. 본 연구에서는 전류밀도를 변화시켜가며 활성슬러지의 막 여과를 수행하여 전기응집이 막 오염 저감에 미치는 영향과 메커니즘을 파악하고자 하였다. 활성슬러지 혼합액을 전기응집한 후 회분식교반셀로 분리 막의 여과성능을 평가하였다. 전류밀도(A/m2)를 10에서 40으로 증가시켰을 때 총 오염 저항 (Rc+Rf) 값이 18%에서 79%까지 감소하여 전기응집으로 인해 분리 막의 여과성능이 향상됨을 확인할 수 있었다. 전기응집 전후로 유기물 농도와 활성슬러지 입도분포 변화는 거의 일어나지 않았다. 여과 성능의 향상은 수산화알루미늄, Al(OH)3이 생성되어 막 표면에 부착되면서 오염물질이 쌓이게 됨을 방지하는 역할, 즉 dynamic membrane 으로 작용하였기 때문인 것으로 판단되었다.

담체가 첨가된 침지형 막결합 연속회분식 반응기에서 제거효율과 여과성능에 대한 담체의 효과 (The Effect of Media on the Removal Efficiency and Filtration Performance in the Submerged Membrane-Coupled Sequencing Batch Reactor with Media)

  • 김승건;이호원
    • 멤브레인
    • /
    • 제22권6호
    • /
    • pp.450-460
    • /
    • 2012
  • 스펀지 형태의 담체가 첨가된 침지형 막결합 연속회분식 생물반응기에서 담체가 제거효율과 여과성능에 미치는 영향을 조사하였다. 담체는 반응기 부피 기준으로 각각 5%, 10% 및 20% 첨가하였고, 담체를 첨가하지 않은 반응기를 대조군으로 하였다. COD, T-N 및 T-P에 대한 제거효율은 담체 첨가 유무에 관계없이 큰 차이가 없었다. 그러나 담체를 첨가한 경우, 첨가하지 않은 경우에 비해 조업시간에 따른 막간차압(TMP)은 매우 서서히 증가하였다. 이러한 결과는 폭기에 의해 상승하는 담체가 막 표면과 충돌하게 되고, 이때 막 표면에 형성된 케이크 층을 제거시키기 때문이다. 결론적으로 담체가 첨가된 막결합형 연속회분식 생물반응기는 담체가 없는 반응기에 비해 여과성능이 크게 개선되어, 폐수처리에 효과적으로 활용될 수 있을 것이다.

강변여과수(충적층 및 하상)를 이용한 냉방시스템 설치 및 모니터링 (Installation and Monitoring of Bankfiltration (including alluvial and riverbed deposits) Source Heat Pump Cooling System)

  • 정우성;황기섭;안영섭
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.5-8
    • /
    • 2006
  • The Alternative energy has lately attracted considerable attention due to the high oil price and environment problem. In this study, pilot test facility for using the geothermal energy source from riverbank filtration was constructed and monitoring devices are installed to estimate the efficiency of this system. Initial installation cost can be saved efficiently by connect ing a heat pump system into the exist ing pumping well in Changwon riverbank filtration site. One set of monitoring results during summer was presented and analyzed.

  • PDF

Pilot Study Analysis of Three Different Processes in Drinking Water Treatment

  • Kim, Dae-Ho;Lee, Byoung-Ho
    • Environmental Engineering Research
    • /
    • 제16권4호
    • /
    • pp.237-242
    • /
    • 2011
  • In this study, three pilot-scale plants with the capacity 30 $m^3$/day were designed and set up to treat reservoir water for the production of drinking water. Three treatment processes were compared in the pilot testing: process 1 (coagulation- flocculation- sedimentationsand filtration- ozone- BAC); process 2 (coagulation- flocculation- sedimentation- microfiltration-ozone- BAC); and process 3 (coagulation- flocculation- sedimentation- sand filtration- GAC). The quality of water has been evaluated on the basis of selected parameters such as turbidity, color, consumption of $KMnO_4$, dissolved organic carbon (DOC), trihalomethane formation potential (THMFP), geosmin and 2-MIB. A detailed assessment of performance was carried out during a five months operation. Process 2 was found to have better removal efficiency of DOC, THMFP, geosmin and 2-MIB than process 1 and process 3 under identical conditions, although the removal rate of color was found to be the same in the three cases.