• 제목/요약/키워드: filter replacement

검색결과 68건 처리시간 0.025초

차량용 에어컨필터 교환시점 알림 시스템 및 과농도 먼지 차단 시스템 (Auto Alarm System of Replacement Period for Vehicle Cabin Filter & Interception System of High Concentration Dust)

  • 이규세;변성욱;김영민;박성우;염영진
    • 대한기계학회논문집A
    • /
    • 제32권11호
    • /
    • pp.1035-1040
    • /
    • 2008
  • Replacement period for vehicle cabin filter of most automobiles is fixed without consideration of conditions of filter and environment. Auto alarm system of replacement period at vehicle cabin filter and interception system of high concentration dust were developed. Control program which is related with the AQS has been developed based on the circuit drive algorithm. This system is expected to be beneficial to passenger's health and to extend the life of the filter which regulates vehicle HVAC system by ventilation mode change at the time of high concentration dust.

큰느타리 재배사에서 헤파필터 교체 이후 기간에 따른 미생물상 변화 (Changes in microbial phase by period after hepa filter replacement in King oyster(Pleurotus eryngii) mushroom cultivation)

  • 박혜성;민경진;이은지;이찬중
    • 한국버섯학회지
    • /
    • 제18권4호
    • /
    • pp.398-402
    • /
    • 2020
  • 버섯은 대부분 시설에서 재배되기 때문에 안전하게 고품질의 버섯 생산을 위해서는 재배사 내 환경에 대한 정보가 필요하다. 따라서 본 연구에서는 헤파필터 교체에 따른 큰느타리 재배사 대기중 미생물상 변화를 분석하여 헤파필터 적정 교체기간을 설정하고자 연구를 수행하였다. 헤파필터 교체 전 재배단계별 대기중 세균 및 진균 밀도는 배지제조과정에서 세균 169.7 cfu/㎥, 진균 570 cfu/㎥, 균 긁기과정에서 세균 126.3 cfu/㎥, 진균 560cfu/㎥로 부유균의 밀도가 가장 높았다. 헤파필터 교체 후 세균의 밀도는 배양실에서 가장 낮아졌고, 진균의 밀도는 냉각실에서 가장 낮게 나타났다. 헤파필터 교체전 Cladosporium sp. 등 7속 7종이었고, 교체 후 1개월은 Penicillium sp. 등 6속 6종, 2개월은 Cladosporium cladosporioides 등 4속 7종, 3개월차는 Mucor plumbeus 등 5속 7종, 4개월에서 6개월까지는 Penicillium brevicompactum 등 각각 5속 12종, 5속 10종, 5속 10종으로 교체 후 기간이 지날수록 종이 다양해지고 증가하였다. 부유균의 밀도는 헤파필터 교체 후 2개월 후 가장 낮았고 차츰 증가하다가 6개월에는 교체전 밀도와 비슷해지거나 높아지는 것을 확인하였다. 따라서 헤파필터는 6개월마다 교체하는 것이 오염저감을 위해 효율적인 것으로 판단된다.

The Effects of Nafamostat Mesilate on a Bleeding Risk as an Anticoagulant During Use as a Continuous Renal Replacement Therapy: Systematic Review

  • Kang, YoungJu;Moon, Su Jee;Kang, Hye-Young
    • 보건의료기술평가
    • /
    • 제6권2호
    • /
    • pp.133-141
    • /
    • 2018
  • Objectives: In the past, the pharmaceutical drug heparin was mostly used as the anticoagulant for continuous renal replacement therapy (CRRT), but the duration time is long to have the risk of a bleeding adverse effect, and in that case the drug therapy Nafamostat mesilate was utilized instead, as it is more safe in this case, with a short half-life and is increasing in use to permit lower concerns for bleeding incidents. However, there are insufficient number of large-scale studies on the comparison of Nafamostat mesilate and heparin. Methods: In this study, a systematic review are used to compare the bleeding risk of Nafamostat mesilate and Heparin, as subjected to patients and procedures for measuring risks performed with a CRRT, and the filter life span is to be evaluated as well in this patients. Results: As a result of literature review search, a total of 6 studies were included in systematic review. The reducing risk of bleeding and filter life span was analyzed. The retrospective cohort studies confirm that Nafamostat mesilate is less at risk of bleeding than heparin. And a cohort study confirms that Nafamostat mesilate is longer filter lifespan than heparin and randomized controlled trial studies show that Nafamostat mesilate is longer filter lifespan than not using the anticoagulants. Conclusion: Nafamostat mesilate is considered to be a good therapeutic option because it has a longer filter life span as well as the advantage of reducing bleeding.

방진 마스크 필터 교체와 성능 변화의 상관성 조사 (Evaluation of the Relationship between Filter Replacement and Filter Performance Change in Particulate Respirators)

  • 이헌용;박지훈;윤충식
    • 한국산업보건학회지
    • /
    • 제27권4호
    • /
    • pp.283-290
    • /
    • 2017
  • Objectives: This study aimed to evaluate the relationship between filter replacement and filter performance change in particulate filters used in the workplace. Methods: Three types of particulate respirator filters are mainly used in the workplaces. These were tested against the filter performance safety certification standard for dust masks established by the Ministry of Employment and Labor(MoEL). Used filters were collected to test their performance, such as filter pressure drop, efficiency, and quality factors. All these factors were evaluated by a filter tester. To compare filter performance between used and new ones, the same kinds of new filters were also tested together under the same procedures. Results: A total of 270 used filters were collected for testing. The main reasons to replace the filters were difficulty in breathing(46.2%), dirty/odor influx(19.7%), and a combination of factors(26.7%). The pressure drop for two special class groups was significantly different(new filters: $20.72{\pm}3.33mmH_2O$; used filters: $24.70{\pm}5.26mmH_2O$, p<0.0001). In the case of penetration, new filter groups indicated $0.0032{\pm}0.0040%$, while that of the used filters was $0.0596{\pm}0.1187%$. The quality factor for the used filters($0.34{\pm}0.09$) significantly decreased compared to the new filters($0.53{\pm}0.08$) (p<0.0001). Conclusions: Filter performance including pressure drop, penetration, and the quality factor was evaluated and compared between new and used filters in the workplace. The results showed that general filter performance deteriorated more for change of pressure drop, penetration and the quality factor.

A Capacitance Estimation of Film Capacitors in an LCL-Filter of Grid-Connected PWM Converters

  • Heo, Hong-Jun;Im, Won-Sang;Kim, Jang-Sik;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • 제13권1호
    • /
    • pp.94-103
    • /
    • 2013
  • A capacitor deterioration of LCL-filter grid-connected PWM converters is progressed by the self-healing mechanism. It leads to the degradation of the filter performance and drop of power factor. Thus, it is required to diagnose fault-point of capacitors and determine the replacement time. Typically, the fault of capacitors is determined when the capacitance is reduced up to 80% from initial value. This paper proposes algorithm to the determine capacitor replacement time of an LCL filter. The algorithm takes the advantage of change of the response on the injected resonant frequency corresponding to 80% value from the initial capacitance. The results of the algorithm are demonstrated through simulations and experiments.

가변 문턱조건을 이용한 odd/even median filter 알고리즘 (A Study on the Algorithm for Adaptive Odd/Even Multi-shell Median Filter)

  • 조상복;이일권
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.495-498
    • /
    • 1999
  • In this paper, we propose the adaptive Odd/Even Multi-shell Median Filter(adaptive O/E MMF) to improve the defect that Modified Multi-shell Median Filter(MMMF) can not recover missing lines of vertical and cross direction. This filter uses odd/even multi-shells and new proposed threshold strategy The performance of the proposed filter is evaluated over image 'airfield 'by using MATLAB. As the proposed threshold strategy eliminate the number of redundant replacement, it suppresses impulse noise and recovers missing lines.

  • PDF

오배자 천연염색을 적용한 필터교체형 면마스크 개발 (Development of Filter Replacement Type Mask by Natural Dyeing of Gallnut)

  • 김민서;송현주;이소희
    • 한국염색가공학회지
    • /
    • 제32권4호
    • /
    • pp.199-207
    • /
    • 2020
  • Recently, as the demand for masks increases, the use of filter-replaceable cotton masks is increasing. A filter-replaceable cotton mask is one of the ways to solve the environmental problems of a disposable nonwoven mask because only the filter can be replaced after washing. Cotton fiber products are known to be environmentally friendly, but cotton products dyed with general synthetic dyes are not safe for humans. In this study, to prepare of cotton mask applied with natural dyeing, the optimal dyeing conditions are set when dyeing with gallnut extract. A polychromatic natural dye that changes color by mordant, and the functionalities of gallnut dyeing fabrics are evaluated. The experimental method is dyed the gallnut by temperature and time by concentration to set the optimal conditions. The color fastness rating grade of aluminium potassium sulfate dodecahydrate, copper(ll) sulfate pentahydrate, and iron(ll) chloride tetrahydrate were evaluated after the pre/post mordanting.

SFR 기법을 이용한 영상 융합의 정확도 향상에 관한 연구 (A Study on the Improvement of Image Fusion Accuracy Using Smoothing Filter-based Replacement Method)

  • 윤공현;손홍규
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2006년도 춘계학술발표회 논문집
    • /
    • pp.187-192
    • /
    • 2006
  • Image fusion techniques are widely used to integrate a lower spatial resolution multispectral image with a higher spatial resolution panchromatic image. However, the existing techniques either cannot avoid distorting the image spectral properties or involve complicated and time-consuming decomposition and reconstruction processing in the case of wavelet transform-based fusion. In this study a simple spectral preserve fusion technique: the Smoothing Filter-based Replacement(SFR) is proposed based on a simplified solar radiation and land surface reflection model. By using a ratio between a higher resolution image and its low pass filtered (with a smoothing filter) image, spatial details can be injected to a co-registered lower resolution multispectral image minimizing its spectral properties and contrast. The technique can be applied to improve spatial resolution for either colour composites or individual bands. The fidelity to spectral property and the spatial quality of SFM are convincingly demonstrated by an image fusion experiment using IKONOS panchromatic and multispectral images. The visual evaluation and statistical analysis compared with other image fusion techniques confirmed that SFR is a better fusion technique for preserving spectral information.

  • PDF

Cache-Filter: A Cache Permission Policy for Information-Centric Networking

  • Feng, Bohao;Zhou, Huachun;Zhang, Mingchuan;Zhang, Hongke
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권12호
    • /
    • pp.4912-4933
    • /
    • 2015
  • Information Centric Networking (ICN) has recently attracted great attention. It names the content decoupling from the location and introduces network caching, making the content to be cached anywhere within the network. The benefits of such design are obvious, however, many challenges still need to be solved. Among them, the local caching policy is widely discussed and it can be further divided into two parts, namely the cache permission policy and the cache replacement policy. The former is used to decide whether an incoming content should be cached while the latter is used to evict a cached content if required. The Internet is a user-oriented network and popular contents always have much more requests than unpopular ones. Caching such popular contents closer to the user's location can improve the network performance, and consequently, the local caching policy is required to identify popular contents. However, considering the line speed requirement of ICN routers, the local caching policy whose complexity is larger than O(1) cannot be applied. In terms of the replacement policy, Least Recently Used (LRU) is selected as the default one for ICN because of its low complexity, although its ability to identify the popular content is poor. Hence, the identification of popular contents should be completed by the cache permission policy. In this paper, a cache permission policy called Cache-Filter, whose complexity is O(1), is proposed, aiming to store popular contents closer to users. Cache-Filter takes the content popularity into account and achieves the goal through the collaboration of on-path nodes. Extensive simulations are conducted to evaluate the performance of Cache-Filter. Leave Copy Down (LCD), Move Copy Down (MCD), Betw, ProbCache, ProbCache+, Prob(p) and Probabilistic Caching with Secondary List (PCSL) are also implemented for comparison. The results show that Cache-Filter performs well. For example, in terms of the distance to access to contents, compared with Leave Copy Everywhere (LCE) used by Named Data Networking (NDN) as the permission policy, Cache-Filter saves over 17% number of hops.

여과필터를 포함한 세척이 가능한 수도꼭지 어셈블리 하우징 개발을 위한 최적설계 연구 (Optimal Design Study for Development of Washable Faucet Assembly Housing Including Filtration Filter)

  • 손인수;배상대
    • 한국산업융합학회 논문집
    • /
    • 제24권5호
    • /
    • pp.581-587
    • /
    • 2021
  • In recent years, contamination of drinking water sources has emerged as a serious social problem, such as a large number of impurities in tap water or groundwater or the supply of suitable water due to rust of pipes. Although the government and public institutions are implementing various measures to protect water sources, they cannot improve water quality in a short period of time because of the enormous cost involved. Therefore, in recent years, preference has been given to a device that converts tap water, which is hard water, into soft water by installing a separate water softener at the faucet from which tap water is discharged. However, the existing filtration device has a problem that filtration performance is gradually lowered when impurities accumulate in the filter, requiring continuous filter replacement. In this study, the optimal design of the filter housing was performed to develop a water softener that can be washed when impurities accumulate on the filter inside the water softener connected to the faucet. For optimal design of the filter housing, fluid and fluid-structural interaction analysis were performed on the design pressure to determine the shape and thickness of the housing, and design review was performed through prototype.