• Title/Summary/Keyword: film-less system

Search Result 180, Processing Time 0.026 seconds

Effect of Shape Error of an Air Stage on Motion Precision (공기 스테이지의 형상 오차가 운동정밀도에 미치는 영향)

  • Ryu, Daewon;Lee, Jae Hyeok;Park, Sang-Shin;Kim, Gyu Ha
    • Tribology and Lubricants
    • /
    • v.36 no.2
    • /
    • pp.68-74
    • /
    • 2020
  • In this study, the effect of the shape error of a guideway on the movement of a stage that uses an air bearing is analyzed. The shape error of moving parts supported by the air bearing is known not to affect the vibrations of moving parts as much as the magnitude of the shape error. This is called the "averaging effect." In this study, the effect of shape error on a guideway, as well as the averaging effect of an air-bearing system, is analyzed theoretically using a dynamic-analysis program. The dynamic-analysis program applies a commercially available code in COMSOL and solves the Reynolds equation between the stage and the guideway, along with the equation of motion of the stage. The stage is modeled as a two-degree-of-freedom system. The shape error is applied to the film thickness function in the form of a sine wave. The stage movement is analyzed using the fast Fourier transform process. The eccentricity and tilting are found to be proportional to the amplitude of the shape error of the guideway. Stage vibrations are less than 10% of the amplitude of the shape error on the guideway. This means that the averaging effect of the air bearing is verified quantitatively. Moreover, if the air supply position matches the shape error in the guideway, there is a notable change in eccentricity and tilting.

2 Cropping systems using field crops in unheated plastic house at paddy field

  • Shin, Jung-Ho;Moon, Jin-Young;Song, Jae-Ki;Choi, Yong-Jo;Hong, Kwang-Pyo
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.279-279
    • /
    • 2017
  • In Korea, the single span unheated plastic house cultivated crops from autumn to spring of the following year, removed the plastic film and frame, cultivated rice, set up a plastic house again and cultivated crops. The crops in the greenhouse are utilized mainly for the production of leaf vegetables such as lettuce, leek, and fruit vegetables such as strawberry, watermelon, oriental melon, etc. and raising high income. Because, the production of these crops has characteristics requiring a lot of labor and it is difficult to produce horticultural crops at unheated plastic houses as the rural population ages. Therefore, we conducted a test to develop a crop planting system to cultivate crops in single span unheated plastic houses, although the utilization of labor is less than that of horticultural crops. The prior cropping cultivated three cultivars of sweet potatoes early, the second produced cultivated sweet potatoes, corn and soybeans. In the cultivation of the previous cropping, the sweet potatoes were harvested on the 113th day after planting on March 30th, the yield was 822 kg/10a for Pungwonmi, 1,377 kg/10a for Jinhongmi, 1,483 kg/10a for the Dahomi. Because of differences, the yield of Pungwonmi cultivar was less than that other cultivars and the yield of open field cultivations, we will expect further research. In the cultivation of the succeeding crops sweet potatoes were planted on July 27 and harvested 110 days later and investigated. The product yield of Pungwonmi cultivar was 1,024 kg/10a, and the Jinhongmi, Dahomi cultivars were not at economic level for sale and were necessary to review. In succeeding-crops, corn tested the Ilmichal cultivar, seeded on 27th July, harvested on October 11th. The day of silking was 45 days after sowing, the yield was 1,156 kg/10a, the goods rate was 100% level. The beans in the succeeding cultivation crop were sowed on 27th July, the early maturing of the varieties coming to Hwangeumol and Saeol cultivar, on 17th October, the late maturing soybean Daewonkong cultivar were harvested on October 21st. The yield of early maturing two cultivars was 214 kg/10a, Daewonkong was 257 kg/10a, and 100 seeds weight which were more than the early maturing beans were also heavy. When calculating these incomes price-wise according to the harvest time, we were able to consider the income in the order of corn, sweet potato and soybean from the second term crop. Various studies such as varieties, mulching method, moisture management, control environment management, etc. are considered necessary to develop cropping systems with sweet potato and field crops in future unheated plastic house.

  • PDF

The Accuracy of the Digital Imaging System and the Frequency Dependent Type Apex Locator in Root Canal Length Measurement (근관장 측정에 있어서 디지털 영상 처리기와 주파수 의존형 측정기의 정확도)

  • Lee Byaung-Rib;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.435-459
    • /
    • 1998
  • In order to achieve a successful endodontic treatment, root canals must be obturated three-dimensionally without causing any damage to apical tissues. Accurate length determination of the root canal is critical in this case. For this reason, I've used the conventional periapical radiography, Digora/sup (R)/(digital imaging system) and Root ZX/sup (R)/(the frequency dependent type apex locator) to measure the length of the canal and compare it with the true length obtained by cutting the tooth in half and measuring the length between the occlusal surface and the apical foramen. From the information obtained by these measurements, I was able to evaluate the accuracy and clinical usefulness of each systems. whether the thickness of files used in endodontic therapy has any effect on the measuring systems was also evaluated in an effort to simplify the treatment planning phase of endodontic treatment. 29 canals of 29 sound premolars were measured with #15, #20, #25 files by 3 different dentists each using the periapical radiography. Digora/sup (R)/ and Root ZX/sup (R)/. The measurements were then compared with the true length. The results were as follows: 1. In comparing mean discrepancies between measurements obtained by using periapical radiography(mean error: -0.449±0.444 mm), Digora/sup (R)/(mean error: -0.417±0.415 mm) and Root ZX/sup (R)/(mean error: 0.123±0.458 mm) with true length. periapical radiography and Digora/sup (R)/ system had statistically significant differences(p<0.05) in most cases while Root ZX/sup (R)/ showed none(p>0.05). 2. By subtracting values obtained by using periapical radiography, Digora/sup (R)/ and Root ZX/sup (R)/ from the true length and making a distribution table of their absolute values. the following analysis was possible. In the case of periapical film. 140 out of 261<53.6%) were clinically acceptable satisfying the margin of error of less than 0.5 mm. 151 out of 261 (53,6%) were acceptable in the Digora/sup (R)/ system while Root ZX/sup (R)/ had 197 out of 261(75.5%) within the limits of 0.5mm margin of error. 3. In determining whether the thickness of files has any effect on measuring methoths, no statistically significant differences were found(p>0.05). 4. In comparing data obtained from these methods in order to evaluate the difference among measuring methods, there was no statistically significant difference between periapical radiography and Digora/sup (R)/ system(p>0.05), but there was statistically significant difference between Root ZX/sup (R)/ and periapical radiography(p<0.05). Also there was statistically significant difference between Root ZX/sup (R)/ and Digora/sup (R)/ system(p<0.05). In conclusion, Root ZX/sup (R)/ was more accurate when compared with the Digora/sup (R)/ system and periapical radiography and seems to be more effective clinically in determining root canal length. But Root ZX/sup (R)/ has its limits in determining root morphology and number of roots and its accuracy becomes questionable when apical foramen is open due to unknown reasons. Therefore the combined use of Root ZX/sup (R)/ and the periapical radiography are mandatory. Digora/sup (R)/ system seems to be more effective when periapical radiographs are needed in a short period of time because of its short processing time and less exposure.

  • PDF

Domestic Intercomparison Study for the Performance of Personnel Dosimeters (개인선량계 성능의 국내 상호비교)

  • Kim, Jang-Lyul;Chang, Si-Young;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.3
    • /
    • pp.147-153
    • /
    • 1996
  • The Korea Atomic Energy Research Institute(KAERI) conducted a intercomparison study for personnel dosimetry services in Korea to enhance the accuracy and precision of the dosimetry system. Nine types of dosimeters(6 TLD, 3 film badge) from 7 institutions took part in this intercomparison study. Each participant submitted 30 dosimeters including transit control for irradiations. Both TLDs and film badges were irradiated with Cs-137 gamma, Sr/Y-90 beta and 4 X-ray beams in ISO wide series. Four dosimeters were irradiated on phantom with same dose equivalent for each field category. The delivered dose equivalent was in the range of $0.1{\sim}10mSv$. The participants assessed the results of their dosimeter readings in terms of the ICRU operational quantities for personal monitoring, Hp(10) and Hp(0.07). Most participants except 1 dosimeter estimated the delivered dose equivalent with biases less than ${\pm}25%$ for Cs-137 and Sr/Y-90. But for X-rays, the biases exceeded ${\pm}35%$ in some cases bacause the dose evaluation algorithm was based on the ANSI N13.11 X-ray fields which are different from those given by ISO.

  • PDF

A Study on Dose Distribution Programs in Gamma Knife Stereotactic Radiosurgery (감마나이프 방사선 수술 치료계획에서 선량분포 계산 프로그램에 관한 연구)

  • 고영은;이동준;권수일
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.175-184
    • /
    • 1998
  • The dose distribution evaluation program for the stereotactic radiosurgery treatment planning system using a gamma knife has been built in order to work on PC. And this custom-made dose distribution is compared with that of commercial treatment planning program. 201 source position of a radiation unit were determined manually using a gamma knife collimator draft and geometrical coordinates. Dose evaluation algorithm was modified for our purpose from the original KULA, a commercial treatment planning program. With the composed program, dose distribution at the center of a spherical phantom, 80 mm in diameter, was evaluated into axial, coronal and sagittal image per each collimator. Along with this evaluated data, the dose distribution at a arbitrary point of inside the phantom was compared with those from KULA. Radiochromic film was set up at the center of the phantom and was irradiated by gamma knife, for the verification of dose distribution. In result, the deviation of the dose distribution from that of KULA is less than ${\pm}$3%, which is equivalent to ${\pm}$0.3 mm in 50% isodose distribution for all examined coordinates and film verification. The custom-made program, GPl is proven to be a good tool for the stereotactic radiosurgery treatment planning program.

  • PDF

Relationship between the Level of Depression and Facial EMG Responses Induced by Humor among Children (유머에 의해 유발된 아동의 안면근육반응과 우울 수준과의 관계)

  • Jang, Eun-Hye;Lee, Ju-Ok;Sohn, Sun-Ju;Lee, Young-Chang;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.13 no.1
    • /
    • pp.33-40
    • /
    • 2010
  • The study is to examine relationship between the level of depression and facial EMG responses during the humor condition. Forty-three children(age range 22-49 years) participated in the study. The Korean Personality Inventory for Children(KPI-C) was used to measure the level of depression in children. While children were presented to audio-visual film clip inducing humor, facial EMG were measured on their faces(bilateral corrugators and orbicularis). A baseline state was measured during 60 seconds before the presentation of the stimulus, i.e., emotional state lasting 120 seconds. Participants were asked to report the intensity of their experienced emotion. The results of emotion assessment showed 95.3% appropriateness and 3.81 intensity on the 5 points Likert scale). Facial EMG showed a significant increase while participants experiencing humor compared to baseline state. Additionally, the result showed a negative correlation between right corrugator responses and the level of depression. The study findings showed the more children experienced depression, the less facial EMG activity they had while experiencing humor.

  • PDF

Development of a polystyrene phantom for quality assurance of a Gamma Knife®

  • Yona Choi;Kook Jin Chun;Jungbae Bahng;Sang Hyoun Choi;Gyu Seok Cho;Tae Hoon Kim;Hye Jeong Yang;Yeong Chan Seo;Hyun-Tai Chung
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2935-2940
    • /
    • 2023
  • A polystyrene phantom was developed following the guidance of the International Atomic Energy Association (IAEA) for gamma knife (GK) quality assurance. Its performance was assessed by measuring the absorbed dose rate to water and dose distributions. The phantom was made of polystyrene, which has an electron density (1.0156) similar to that of water. The phantom included one outer phantom and four inner phantoms. Two inner phantoms held PTW T31010 and Exradin A16 ion chambers. One inner phantom held a film in the XY plane of the Leksell coordinate system, and another inner phantom held a film in the YZ or ZX planes. The absorbed dose rate to water and beam profiles of the machine-specific reference (msr) field, namely, the 16 mm collimator field of a GK PerfexionTM or IconTM, were measured at seven GK sites. The measured results were compared to those of an IAEA-recommended solid water (SW) phantom. The radius of the polystyrene phantom was determined to be 7.88 cm by converting the electron density of the plastic, considering a water depth of 8 g/cm2. The absorbed dose rates to water measured in both phantoms differed from the treatment planning program by less than 1.1%. Before msr correction, the PTW T31010 dose rates (PTW Freiberg GmbH, New York, NY, USA) in the polystyrene phantom were 0.70 (0.29)% higher on average than those in the SW phantom. The Exradin A16 (Standard Imaging, Middleton, WI, USA) dose rates were 0.76 (0.32)% higher in the polystyrene phantom. After msr correction factors were applied, there were no statistically significant differences in the A16 dose rates measured in the two phantoms; however, the T31010 dose rates were 0.72 (0.29)% higher in the polystyrene phantom. When the full widths at half maximum and penumbras of the msr field were compared, no significant differences between the two phantoms were observed, except for the penumbra in the Y-axis. However, the difference in the penumbra was smaller than variations among different sites. A polystyrene phantom developed for gamma knife dosimetry showed dosimetric performance comparable to that of a commercial SW phantom. In addition to its cost effectiveness, the polystyrene phantom removes air space around the detector. Additional simulations of the msr correction factors of the polystyrene phantom should be performed.

Fabrication and Characteristics of Integrated Nb DC SQUID (집적화된 Nb DC SQUID 소자의 제작 및 특성)

  • Lee, Yong-Ho;Gwon, Hyeok-Chan;Kim, Jin-Mok;Park, Jong-Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.3
    • /
    • pp.277-281
    • /
    • 1992
  • We have designed, fabricated and tested an integrated planar DC SQUID which incorporates input coil and mofulation coil in thin film structure. The SQUID uses Nb /Al-oxide /Nb Josephson junctions and Pd shunt resistors, and the SQUID loop incorporates two rings connected in series forming figure '8' structure and has the advantage of a negligibly small circulating current for the spatially homogeneous noise fields. The devices were fabricated using photolithographic technique, RF magnetron sputtering, anodic oxidation for insulation and lift-off process. The preliminary test of the fabricated SQUID at 4.2 K showed that the flux-voltage characteristics were smooth enough to adopt standard readout system, and the voltage noise was too small to be measured by direct method and so the white noise was thought to be less than $10^{-4}\;{\phi}_o/\;\sqrt{H_z}$.

  • PDF

A Study on Micro Gas Sensor Utilizing WO$_3$ Thin Films Fabricated by Sputtering Method (스퍼터링법으로 제작한 WO$_3$ 박막을 이용한 NO$_2$ 마이크로 가스센서에 관한 연구)

  • 김창교;이영환;노일호;유홍진;유광수;기창진
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.139-144
    • /
    • 2003
  • A flat type micro gas sensor was fabricated on the p-type silicon wafer with low stress Si$_3$N$_4$, whose thickness is 2 ${\mu}{\textrm}{m}$, using MEMS technology. WO$_3$ thin film as a sensing material for detection of NO$_2$ gas was deposited using a tungsten target by sputtering method, followed by thermal oxidation at several temperatures (40$0^{\circ}C$-$600^{\circ}C$) for one hour. NO$_2$ sensitivities were investigated for the WO$_3$ thin films with different annealing temperatures. The highest sensitivity was obtained for the samples annealed at $600^{\circ}C$ when it was operated at 20$0^{\circ}C$. The results of XRD analysis showed the annealed samples had polycrystalline phase mixed with triclinic and orthorhombic structures. The sample exhibits higher sensitivity when the system has less triclinic structure. The sensitivities, $R_{gas}/R_{air},$ operating at 20$0^{\circ}C$ to 5 ppm NO$_2$ of the sample annealed at $600^{\circ}C$ were approximately 90.

  • PDF

Multi-component $ZnO-In_2O_3-SnO_2$ thin films deposited by RF magnetron co-sputtering

  • Lee, Byoung-Hoon;Hur, Jae-Sung;Back, Sang-Yul;Lee, Jeong-Seop;Song, Jung-Bin;Son, Chang-Sik;Choi, In-Hoon
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2006.10a
    • /
    • pp.68-71
    • /
    • 2006
  • Multi-component $ZnO-In_2O_3-SnO_2$ thin films have been prepared by RF magnetron co-sputtering using targets composed of $In_3Sn_4O_{12}$(99.99%) [1] and ZnO(99.99%) at room temperature. $In_3Sn_4O_{12}$ contains less In than commercial ITO, so that it lowers cost. Working pressure was held at 3 mtorr flowing Ar gas 20 sccm and sputtering time was 30 min. RF power ratio [RF1 / (RFI + RF2)] of two guns in sputtering system was varied from 0 to 1. Each RF power was varied $0{\sim}100W$ respectively. The thickness of the films was $350{\sim}650nm$. The composit ion concentrations of the each film were measured with EPMA, AES and XPS. The low resistivity of $1-2\;{\times}\;10^3$ and an average transmittance above 80% in the visible range were attained for the films over a range of ${\delta}\;(0.3\;{\leq}\;{\delta}\;{\leq}\;0.5)$. The films also showed a high chemical stability with time and a good uniformity.

  • PDF