검색결과 205건 처리시간 0.023초

Thermal Analysis of a Film Cooling System with Normal Injection Holes Using Experimental Data

  • Kim, Kyung-Min;Lee, Dong-Hyun;Cho, Hyung-Hee;Kim, Moon-Young
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권1호
    • /
    • pp.55-60
    • /
    • 2009
  • The present study investigated temperature and thermal stress distributions in a film cooling system with normal injection cooling flow. 3D-numerical simulations using the FEM commercial code ANSYS were conducted to calculate distributions of temperature and thermal stresses. In the simulations, the surface boundary conditions used the surface heat transfer coefficients and adiabatic wall temperature which were converted from the Sherwood numbers and impermeable wall effectiveness obtained from previous mass transfer experiments. As a result, the temperature gradients, in contrast to the adiabatic wall temperature, were generated by conduction between the hot and cold regions in the film cooling system. The gradient magnitudes were about 10~20K in the y-axis (spanwise) direction and about 50~60K in the x-axis (streamwise) direction. The high thermal stresses resulting from this temperature distribution appeared in the side regions of holes. These locations were similar to those of thermal cracks in actual gas turbines. Thus, this thermal analysis can apply to a thermal design of film cooling holes to prevent or reduce thermal stresses.

Evaporation of Water in an Aqueous Lithium Bromide Solution flowing over a Horizontal Tube

  • Kim, Dong-Kwan;Kim, Moo-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.57-62
    • /
    • 2001
  • Falling film heat transfer analyses with aqueous lithium bromide solution were performed to investigate the transfer characteristics of the copper tubes. Finned (knurled) tube and a smooth tube were selected as test specimens. Averaged generation fluxes of water and the heat flux were obtained. As the film flow rate of the solution increased, the generation fluxes of water decreased for both tubes due to the fact that the heat transfer resistance increased with the film thickness. The effect of the enlarged surface area at the knurled tube was supposed to be dominant at a small flow rate. The generation fluxes of water increased with the increasing degree of tube wall superheat. Nucleate boiling is supposed to occur at a wall superheat of 20K for a smooth tube, and at 10K for a knurled tube. The increased performance of the knurled tube was supposed to mainly come from the effect of the increased heating surface area.

  • PDF

CT 검사에서 시간분석에 의한 필름시스템과 PACS의 비교 연구 (Comparison of Time Analysis on the Film Based System Versus PACS in the CT Scanning)

  • 권대철;홍성만;박범
    • 산업공학
    • /
    • 제15권4호
    • /
    • pp.439-443
    • /
    • 2002
  • In this paper, we study to evaluate the relative time required to perform the CT scanning in the PACS versus a film-based system and helical versus non-helical studies. Time studies were performed in 175 consecutive CT scanning. Images from 85 examinations were electronically transferred to a PACS, and 90 were printed to film. The time required to obtain and electronically transfer the images or print the images to film and make the current and previous studies available to the radiologists for interpretation was recorded. The time required for a radiological technologist to complete a CT test was reduced by 43% with the PACS compared with the film-based system and nonhelical was reduced 10~20% with helical studies. This reduction was due to the elimination of a transfer and printing, such as the printing at window or level settings. The use of PACS can result in the elimination of time tasks for the radiological technologist, resulting in marked reduction in examination time. This reduction can result in decreased cost and increased productivity in PACS operation.

수직관내 리튬브로마이드 수용액막의 흡수과정에 대한 비흡수가스의 영향 (Effects of Non-Absorbable Gases on the Absorption Process of Aqueous LiBr Solution Film in a Vertical Tube (I))

  • 김병주;이찬우
    • 대한기계학회논문집B
    • /
    • 제22권4호
    • /
    • pp.489-498
    • /
    • 1998
  • Among the heat/mass exchange units composing an absorption system, the absorber, where the refrigerant vapor is absorbed into the liquid solution is the one least understood. In the present study, the effects of non-absorbable gas on the absorption process of aqueous lithium bromide solution falling film inside a vertical tube were experimentally investigated. In the range of film Reynolds number of 30 ~ 195, heat and mass transfer characteristics were investigated as a function of non-absorbable gas volumetric concentration, 0.2 ~ 20%. An increase of non-absorbable gas volumetric concentration degraded the mass transfer rate dramatically in the absorption process. The reduction of mass transfer rate was significant for the addition of small amount of non-absorbable gas to the pure vapor. At film Reynolds number of 130, an increase of non-absorbable gas concentration from 0.2 to 6.0% resulted in the decrease of mass transfer rate by 36% and 20% of non-absorbable gas by 59%. However the decrease of film Nusselt number with the increase of volumetric concentration of non absorbable gas was relatively smaller than the decrease of Sherwood number. Critical film Reynolds number was identified to exist for the maximum heat and mass transfer regardless of the volumetric concentration of non-absorbable gases.

Integral Analysis of the Effects of Non-absorbable gases on the Heat Mass Transfer of Laminar Falling Film

  • Kim, Byong-Joo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.56-66
    • /
    • 1998
  • The absorption process of water vapor in a liquid film is an important process in LiBr-Water absorption system. The composition of the gas phase, in which a non-absorbable gas is combined with the absorbate, influences the transport characteristics. In the present work, the absorption processes of water vapor into aqueous solutions of lithium bromide in the presence of non-absorbable gas are investigated. The continuity, momentum, energy and diffusion equations for the solution film and gas are formulated in integral forms and solved numerically. It is found that the mass transfer resistance in gas phase increases with the concentration of non-absorbable gas. However the primary resistance to mass transfer is in the liquid phase. As the concentration of non-absorbable gas in the absorbate increases, the interfacial temperature and concentration of absorbate in solution decrease, which results in the reduction of absorption rate. The reduction of mass transfer rate is found to be significant for the addition of a small amount of non-absorbable gas to the pure vapor, especially at the outlet of tube where the non-absorbable gas accumulates. At higher non-absorbable gas concentration, the decrease of absorption rate seems to be linear to the concentration of non-absorbable gas.

  • PDF

미생물 배양 시스템에서의 산소 전달 (Oxygen Transfer in Microbial System)

  • 최동원
    • 한국식품영양학회지
    • /
    • 제7권4호
    • /
    • pp.399-405
    • /
    • 1994
  • Some method was introduced to explain oxygen transfer from broth to cell during aerobic microbe cultivation. It is explained by 5 steps that how desolved oxygen can reach to cell. Among these steps film resistance was the most important factor to describe oxygen transfer. Lumped model and distributed model was introduced to explain oxygen diffusion rate and oxygen consumption rate which occurs in the microbe pellet.

  • PDF

기능성 편광필름을 이용한 2차원/3차원 전환가능 변형 집적 영상 시스템 (Two-dimensional / Three-dimensional convertible modified integral imaging system using functional polarizing film)

  • 송병섭;박순기;민성욱
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2009년도 창립 20주년기념 특별학술발표회
    • /
    • pp.6-7
    • /
    • 2009
  • We proposed the two-dimensional (2D) / three-dimensional (3D) convertible modified integral imaging system using functional polarizing film named $imazer^{TM}$, which transfer or scatter the incident light ray according to the polarizing direction of ray. When the incident light rays transfer to $imazer^{TM}$, the rays generate 3D image through the process of the modified integral imaging system. However, the scattered light rays generate 2D image through the simple backlight scheme when the incident rays are scattered by the film. The proposed method can be implemented the partial 3D display system without any mechanical movements. In this paper, we propose and verify our system using some basic experiments and its results.

  • PDF

Effects of Non-absorbable Gases in the Absorption of Water Vapor by Aqueous LiBr Solution Film on Horizontal Tube Banks

  • Kwon, Ky-Seok;Kim, Byong-Joo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권2호
    • /
    • pp.19-27
    • /
    • 2001
  • In the present study, the effects of film Reynolds number (60∼200) and volumetric content of non-absorbable gases (0∼10%) in water vapor on the absorption process of aqueous LiBr solution were investigated experimentally. The formation of solution film on the horizontal tubes of six rows was observed to be complete for Re>100. Transition film Reynolds number was found to exist above which the Nusselt number and Schmidt number diminishes with solution flow rate. As the concentration of non-absorbable gases increased, mass transfer rate decreased more seriously than heat transfer rate did. the degradation effects of non-absorbable gases seemed to be significant especially when small amount of non-absorbable gases was introduced to the pure water vapor.

  • PDF

분자 동역학을 이용한 나노임프린트 리소그래피에서의 패턴 전사에 관한 연구 (Molecular Dynamics Study on the Pattern Transfer in Nanoimprint Lithography)

  • 강지훈;김광섭;김경웅
    • Tribology and Lubricants
    • /
    • 제21권4호
    • /
    • pp.177-184
    • /
    • 2005
  • The molecular dynamics simulation of nanoimprint lithography (NIL) using $SiO_2$ stamp and amorphous poly-(methylmethacrylate) (PNMA) film is performed to study pattern transfer in NIL. Force fields including bond, angle, torsion, van der Waals and electrostatic potential are used to describe the intermolecular and intramolecular force of PMMA molecules and $SiO_2$ stamp. Nose-Hoover thermostat is used to control the system temperature and cell multipole method is adopted to treat long range interactions. The deformation of PMMA film is observed during pattern transfer in the NIL process. For the detail analysis of deformation characteristics, the distributions of density and stress in PMHA film are calculated. The adhesion and friction forces are obtained by dividing the PMMA film into subregions and calculating the interacting force between subregion and stamp. Their effects on the pattern transfer are also discussed as varying the indentation depth and speed.

비정질 셀레늄을 이용한 직접방식의 디지털 방사선 검출기와 X-ray film과의 MTF측정을 통한 영상 질(quality) 비교평가에 관한 연구 (Comparison Study of the Modulation Transfer Function of a Prototype a-Se based Flat Panel Detector with Conventional Speed Class 400 Film/screen System)

  • Park, Jang-Yong;Park, Ji-Koon;Kang, Sang-Sik;Moon, Chi-Woong;Lee, Hyung-Won;Nam, Sang-Hee
    • 전자공학회논문지SC
    • /
    • 제40권3호
    • /
    • pp.163-171
    • /
    • 2003
  • 디지털 방사선 검출기의 성능을 측정하기 위해 변조전달할수(Modulation Transfer Function)을 측정하여 기존 방사선 영상 시스템인 필름/스크린과 비교하였다. 제작된 디지털 방사선 검출기는 TFT 패널위에 진공 증착법을 통해 비정질 셀레늄이 코팅되었다. 비교 측정물이 감도 400의 필름/스크린은 아날로그 방식의 방사선 검출기로서 현재 임상에서 이용되고 있는 필름이다. Square wave & slit 측정법을 통해 두 시스템의 변조전달함수를 측정하였다. 필름/스핀린의 반치폭(FWHM)은 357㎛(1.4 lp/mm at 50% spatial frequency)으로 측정되었으며, 디지털 방사선 검출 시스템은 200㎛(2.5 lp/mm at 50%)였다. 영상의 표현성능 평가의 결과 디지털 방사선 시스템은 필름 시스템보다 높은 것으로 나타났다.