• Title/Summary/Keyword: film Scanner

Search Result 69, Processing Time 0.026 seconds

Design and fabrication of mirror for optical pick-up head (광기록장치의 pick-up 헤드용 미러의 설계 및 제작)

  • Chon, Joong-Hyun;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3292-3294
    • /
    • 1999
  • In this paper, electrostatic scanner mirror for optical pick-up head is designed and fabricated. The mirror size is $20{\mu}m{\times}2400{\mu}m{\times}2400{\mu}m$ and torsional beam size is $10{\mu}m{\times}20{\mu}m{\times}500{\mu}m$. Static deflection angle is calculated ${\pm}0.4$ degrees when the maximum driving voltage is 20 V. Silicon mirror was fabricated using KOH etching and deep RIE. For passivation of the patterned mirror from KOH solution, parylene thin film was used and its usefulness has been verified. Driving electrode was fabricated using UV LIGA process. Mirror and electrode were bonded.

  • PDF

The Digital Orthophoto Production by the Automative Generation of DEM using Non-photogrammetric Scanner (비측정용 주사기를 사용한 수치표고모델의 자동생성에 의한 수치정사사진 제작)

  • Park, Woon-Yong;Yi, Gi-Chul;Lee, In-Soo;Kim, Jin-Su
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.3 no.2
    • /
    • pp.24-36
    • /
    • 2000
  • This study deals with the optimal method of orthophoto products using the non-photogrammetric scanners. we scanned positive film of aerial photographs at the different resolution and producted the orthophoto using the automatically generated DEM based on the Digital Photogrammetric Workstation, considering aerial image resolutions, DEM interval, resampling method and outpixel size. As a results, the acquired accuracy was worse in horizontal, but good in vertical. So It will be expected that orthophoto using non-photo grammetric scanner is good enough for the acquisition of GIS data and the calculation of soil volumes.

  • PDF

The Properties of Beam Intensity Scanner(BInS) in IMRT with Phantom for Three Dimensional Dose Verification

  • Young W. Vahc;Park, Kwangyl;Byung Y. Yi;Park, Kyung R.;Lee, Jong Y.;Ohyun Kwon;Park, Kwangyl;Kim, Keun M.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.64-64
    • /
    • 2003
  • Objectives: Patient dose verification is clinically the most important parts in the treatment delivery of radiation therapy. The three dimensional(3D) reconstruction of dose distribution delivered to target volume helps to verify patient dose and determine the physical characteristics of beams used in intensity modulated radiation therapy(IMRT). We present Beam Intensity Scanner(BInS) system for the pre treatment dosimetric verification of two dimensional photon intensity. The BInS is a radiation detector with a custom made software for relative dose conversion of fluorescence signals from scintillator. Methods: This scintillator is fabricated by phosphor Gadolinium Oxysulphide and is used to produce fluorescence from the irradiation of 6MV photons on a Varian Clinac 21EX. The digitized fluoroscopic signals obtained by digital video camera will be processed by our custom made software to reproduce 3D relative dose distribution. For the intensity modulated beam(IMB), the BInS calculates absorbed dose in absolute beam fluence, which are used for the patient dose distribution. Results: Using BInS, we performed various measurements related to IMRT and found the followings: (1) The 3D dose profiles of the IMBs measured by the BInS demonstrate good agreement with radiographic film, pin type ionization chamber and Monte Carlo simulation. (2) The delivered beam intensity is altered by the mechanical and dosimetric properties of the collimating of dynamic and/or static MLC system. This is mostly due to leaf transmission, leaf penumbra, scattered photons from the round edges of leaves, and geometry of leaf. (3) The delivered dose depends on the operational detail of how to make multileaf opening. Conclusions: These phenomena result in a fluence distribution that can be substantially different from the initial and calculative intensity modulation and therefore, should be taken into account by the treatment planing for accurate dose calculations delivered to the target volume in IMRT.

  • PDF

Measurement of Ir-192 Source Activity for High Dose Rate Brachytherapy (고 선량률 근접치료시 사용되는 Ir-192 선원의 방사능 평가)

  • 최동락;허승재;안용찬;임도훈;김대용;우홍균
    • Progress in Medical Physics
    • /
    • v.8 no.1
    • /
    • pp.25-29
    • /
    • 1997
  • Ir-192 source activity for high dose rate brachytherapy is measured using Farmertype ionization chamber. The source-to-chamber distance is 10 cm and the measured charge unit is converted to activity unit. The measured values are compared to the values provided from vendor. Because of time dependency of Ir-192 source activity, the activities are regularly checked and compared to calculated values. As the accuracy of Ir-192 source activity is depend on the mechanical measurement setup, we estimated the precision of remote controlled source dwell position using home-made device and film scanner. The difference between measured and predicted dwell position is within 1 mm. As a result, the errors of source activity are 0.7${\pm}$1.5 % for measured and vendor-provided values and 0.l${\pm}$1.2% for measured and time-dependent calculated vlaues. In conclusion, our measured activity has been comparable to the values provided from vendor and our brachytherapy unit has been very accurate until now. Regular quality control of brachytherapy is essential for successful treatment which depends on the accuracy of source position and activity.

  • PDF

An evaluation on crystallization speed of N doped $Ge_2Sb_2Te_5$ thin films by nano-pulse illumination (나노-펄스 노출에 따른 질소 첨가한 $Ge_2Sb_2Te_5$ 박막의 결정화 속도 평가)

  • Song, Ki-Ho;Beak, Seung-Cheol;Park, Heung-Su;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.134-134
    • /
    • 2009
  • In this work, we report that crystallization speed as well as the electrical and optical properties about the N-doped $Ge_2Sb_2Te_5$ thin films. The 200-nm-thick N-doped $Ge_2Sb_2Te_5$ thin film was deposited on p-type (100) Si and glass substrate by RF reactive sputtering at room temperature. The amorphous-to-crystalline phase transformation of N-doped $Ge_2Sb_2Te_5$ thin films investigated by X-ray diffraction (XRD). Changes in the optical transmittance of as-deposited and annealed films were measured using a UV-VIS-IR spectrophotometer and four-point probe was used to measure the sheet resistance of N-doped $Ge_2Sb_2Te_5$ thin films annealed at different temperature. In addition, the surface morphology and roughness of the films were observed by Atomic Force Microscope (AFM). The crystalline speed of amorphous N-doped $Ge_2Sb_2Te_5$ films were measured by using nano-pulse scanner with 658 nm laser diode (power : 1~17 mW, pulse duration: 10~460 ns). It was found that the crystalline speed of thin films are decreased by adding N and the crystalline temperature is higher. This means that N-dopant in $Ge_2Sb_2Te_5$ thin film plays a role to suppress amorphous-to-crystalline phase transformation.

  • PDF

Laser 방식 및 CCD 방식 Film Digitizer의 균일도 비교평가

  • 강원석;정해조;민덕기;김새롬;이상호;김희중
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.80-80
    • /
    • 2003
  • 디지털 의료영상 획득기술과 컴퓨터 및 네트워크 기술의 발달로 현재 각 병원에서는 PACS(Picture Archiving and Communication System)를 설치하여 필름을 사용하지 않고 진단과 진료를 하는 병원이 증가하고 있으며, 이에 따라 기존 필름상태의 의료영상은 필름디지타이저로 디지털 영상화한 후 모니터를 통하여 판독과 진료에 이용하고 있다. 본 연구에서는 현재 세브란스병원에서 사용되고 있는 CCD 방식 필름디지타이저와 레이저 스캐너방식 필름디지타이저의 픽셀값 균일도에 대해 중점적으로 비교, 분석하고자 한다. 픽셀값 균일도 측정을 위해 필름프린터를 이용하여 균일한 광학밀도를 가진 필름을 출력하였다. 그 테스트 필름은 각 사분면에 각기 다른 광학밀도를 가지고 있었으며, 그 광학밀도 값은 각각 0.19, 0.71, 1.41, 그리고 3.10 이었다. 제작된 필름은 레이저 (Model 2905, Array Corp., Japan) 방식과 CCD 방식 (SEDAS Media Film Scanner, Kodak, japan) 디지타이저에 의해 디지털화 되었다. 그 영상들은 다시 분석을 위해 PACS를 통해 PC로 전송되어졌고 자체 제작된 소프트웨어를 이용하여 균일도에 대한 분석을 수행하였다. 하나의 사분면 영상에 대하여 일정한 간격과 크기로 20개의 ROI를 만들고, 그 내부의 픽셀값들의 평균값을 구하여 그 영역의 대푯값으로 하였다. 그 대푯값들 중 최대값과 최소값의 차이에 대한 백분율로써 균일도를 표시하였다. 그 결과 광학밀도가 0.19인 사분변의 영상에서의 균일도는 레이저 방식 및 CCD 방식 각각에서 99.8%, 94.3%였으며, 0.71인 사분면에서는 99.4%, 75.6%, 1.41 일때는 97.9%, 62.96%, 그리고 3.1인 사분면에서는 82.7%, 53.7%였다. 같은 광학밀도를 가진 사분면에서는 레이저방식의 균일도가 CCD 방식에 비해 더 우수함을 알 수 있었으며, 같은 방식에서 얻은 영상이라 할지라도 광학 밀도값이 높은 사분변에서 얻은 영상일수록 균일도가 떨어짐을 알 수 있었다. 결론적으로, 레이저 방식 필름 디지타이저는 균일도 면에서도 CCD 방식에 비해 우수함을 알 수 있었으며 CCD 방식은 백라이트의 균일도가 영상의 균일도에 영향을 미칠수도 있는 만큼 향후 거기에 대한 연구도 이루어져야 할 것으로 생각된다.

  • PDF

Evaluation of Image Quality according to the Use of Attachable X-ray Table Equipped with Heating Device (가열장치를 구비한 부착형 X선 촬영대의 사용에 따른 화질 평가)

  • Song, Jongnam;Kim, Eungkon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.219-225
    • /
    • 2015
  • This study aims to evaluates the image quality of CR and DR that are scanned with the use of the attachable carbon heater X-ray scanner table equipped with heating device by measuring SNR and CNR before and after the attachment of the said table. In the aluminum staircase testing, CR increased SNR and CNR when attached with the table, while DR decreased SNR and CNR. In the human-body model phantom testing, CR increased SNR and CNR only in the low-energy low-dose radiation and the high-energy high-dose radiation, but decreased SNR and CNR under all other conditions. In conclusion, the use of such table can make the patient feel comfortable by removing his or her anxiety, thus helping the testing, but in the actual clinical application thereof, if the thickness and material of the bottom film and the protective film, including the carbon heater, are not considered, it affects the picture quality, thereby requiring continuous research on the use of such table.

Automatic Detection of Kidney Tumor from Abdominal CT Scans (복부 CT 영상에서 신장암의 자동추출)

  • 김도연;노승무;조준식;김종철;박종원
    • Journal of KIISE:Software and Applications
    • /
    • v.29 no.11
    • /
    • pp.803-808
    • /
    • 2002
  • This paper describes automatic methods for detection of kidney and kidney tumor on abdominal CT scans. The abdominal CT images were digitalized using a film digitizer and a gray-level threshold method was used to segment the kidney. Based on texture analysis results, which were perform on sample images of kidney tumors, SEED region of kidney tumor was selected as result of homogeneity test. The average and standard deviation, which are representative statistical moments, were used to as an acceptance criteria for homogeneous test. Region growing method was used to segment the kidney tumor from the center pixel of selected SEED region using a gray-level value as an acceptance criteria for homogeneity test. These method were applied to 113 images of 9 cases, which were scanned by GE Hispeed Advantage CT scanner and digitalized by Lumisvs LS-40 film digitizer. The sensitivity was 85% and there was no false-positive results.

Characteristics of $Ag_x(Ge_2Sb_2Te_5)_{1-x}$ (x= 0, 0.05, 0.1) thin films for PRAM (PRAM을 위한 $Ag_x(Ge_2Sb_2Te_5)_{1-x}$ (x= 0, 0.05, 0.1) 박막의 특성)

  • Kim, Sung-Won;Song, Ki-Ho;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.21-22
    • /
    • 2008
  • In the paper, we report several experimental data capable of evaluating the phase transformation characteristics of $Ag_x(Ge_2Sb_2Te_5)_{1-x}$ (x =0, 0.05, 0.1) thin films. The $Ag_x(Ge_2Sb_2Te_5)_{1-x}$ phase change thin films have been prepared by thermal evaporation. The crystallization characteristics of amorphous$Ag_x(Ge_2Sb_2Te_5)_{1-x}$ thin films were investigated by using nano-pulse scanner with 658 nm laser diode (power; 1~17 mW, pulse duration; 10~460 ns) and XRD measurement. It was found that the more Ag is doped, the more crystallization speed was 50 improved. In comparision with $Ge_2Sb_2Te_5$ thin film, the sheet resistance$(R_{amor})$ of the amorphous $Ag_x(Ge_2Sb_2Te_5)_{1-x}$ thin films were found to be lager than that of $Ge_2Sb_2Te_5$ film($R_{amor}$ $\sim10^7\Omega/\square$ and $R_{cryst}$ 10 $\Omega/\square$). That is, the ratio of $R_{amor}/R_{cryst}$ was evaluates to be $\sim10^6$ This is very helpful to writing current reduction of phase-change random acess memory.

  • PDF