• Title/Summary/Keyword: filling method

Search Result 1,094, Processing Time 0.029 seconds

Cu Through-Via Formation using Open Via-hole Filling with Electrodeposition (열린 비아 Hole의 전기도금 Filling을 이용한 Cu 관통비아 형성공정)

  • Kim, Jae-Hwan;Park, Dae-Woong;Kim, Min-Young;Oh, Tae Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.4
    • /
    • pp.117-123
    • /
    • 2014
  • Cu through-vias, which can be used as thermal vias or vertical interconnects, were formed using bottom-up electrodeposition filling as well as top-down electrodeposition filling into open via-holes and their microstructures were observed. Solid Cu through-vias without voids could be successfully formed by bottom-up filling as well as top-down filling with direct-current electrodeposition. While chemical-mechanical polishing (CMP) to remove the overplated Cu layer was needed on both top and bottom surfaces of the specimen processed by top-down filling method, the bottomup process has an advantage that such CMP was necessary only on the top surface of the sample.

Experimental verification and improvement of heat transfer tube local wall temperature measurement method

  • Jiabao Liu;Xiaxin Cao;Peixun Yang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4317-4328
    • /
    • 2023
  • To ensure the measuring accuracy of the wall temperature, the outer wall temperature measurement values by using three kinds of thermocouple welding methods were analyzed and evaluated in the paper, including single-point flush-mounted in the wall groove method, single-point insert-mounted in the wall groove, and outer surface direct welding method, based on the application of a tube-in-tube condensing heat exchanger. And the impacts of silver, tin, and thermal resistance adhesive as filling materials on wall temperature measurement were also investigated, and the results were compared to that obtained without filling materials. The results showed that the wall temperatures measured by the three welding methods were lower than the theoretically calculated value. And the wall temperature measured by the outer surface direct welding method was lowest under the same experimental conditions. The wall temperatures measured by single-point flush-mounted and insert-mounted in the wall groove methods were also affected by different welding filling materials. It was found that the greater the thermal resistance of filling materials, the smaller the heat loss. By analyzing the reasons for the low measured value of wall temperature, a new wall temperature measurement method was developed to improve the accuracy of the current measurement method. Meanwhile, the outer wall temperature measurement experiments of vertical and horizontal heat transfer tubes were carried out to validate and calibrate the improved outer wall temperature measurement method. The results showed that the average outer wall temperature deviation measured by the improved wall temperature measurement method ranged from - 0.82% to +2.29% for vertical tubes and - 4.75% to - 1.44% for horizontal tubes, and the improved measurement method had good measurement accuracy.

A Study on Improvement of Halftoning using Random Space Filling Curve (무작위 공간 채움 곡선을 이용한 하프토닝의 개선 방안)

  • Jho, Cheung-Wonn
    • Journal of Digital Convergence
    • /
    • v.12 no.1
    • /
    • pp.415-421
    • /
    • 2014
  • In this paper, we proposed problem and improvement of halftoning using random space filling curve. Random space filling curve is developed as a solution for shortcoming which space filling curve has self-similarity. It is used to reduce regular pattern can be occurred in constant brightness area in order that randomness apply to scanning path. But there is a problem that some area along scanning path can show too bright result in halftoning using random space filling curve. In this paper, we analyzed cause of problem and proposed single pixel error diffusion as a solution method. This method can avoid over-accumulated error and show better result in halftoning.

A study on the seismic performance of reinforced concrete frames with dry stack masonry wall using concrete block

  • Joong-Won Lee;Kwang-Ho Choi
    • Earthquakes and Structures
    • /
    • v.24 no.3
    • /
    • pp.205-215
    • /
    • 2023
  • Currently, many studies are underway at home and abroad on the seismic performance evaluation and dry construction method of the masonry structure. In this study, a dry stack masonry wall system without mortar using concrete blocks is proposed, and investigate the seismic performance of dry filling wall frames through experimental studies. First, two types of standard blocks and key blocks were designed to assemble dry walls of concrete blocks. And then, three types of experiments were manufactured, including pure frame, 1/2 height filling wall frame, and full height filling wall frame, and cyclic load experiments in horizontal direction were performed to analyze crack patterns, load displacement history, rebar deformation yield, effective stiffness change, displacement ductility, and energy dissipation capacity. According to the experimental results, the full height filling wall frame had the largest horizontal resistance against the earthquake load and showed a high energy dissipation capacity. However, the 1/2 height filling wall frame requires attention because the filling wall constrains the effective span of the column, limiting the horizontal displacement of the frame. In addition, the concrete block was firmly assembled in the vertical direction of the wall as the horizontal movement between the concrete blocks was allowed within installation margin, and there was no dropping of the assembled concrete block.

A COMPARATIVE STUDY ON THE COMPOSITE RESTORATION DESIGN AND PLACEMENT METHODS USING THREE DIMENSIONAL FINITE ELEMENT ANALYSIS (광중합 콤포짓트레진의 수복형태 및 방법에 관한 삼차원 유한요소분석법적 비교 연구)

  • Lee, Jung-Taek;Yim, Soon-Ho;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.133-149
    • /
    • 1998
  • Clinical application of composite resin recently draw great concerns in dentistry. Especially due to advantages such as esthetics, adhesiveness, simple clinical procedures, various shapes and kinds of composite resins are widely being applied to prosthodontics, conservative dentistry, and orthodontics. But, clinical problems attributable to the polymerization shrinkage of composite resin have been proposed, and we have to regard clinical problems such as secondary caries, loss of restoration, fracture of the surrounding tooth structure, marginal discoloration, and tooth sensitivity, and many portions are remained to be overcome. Therefore, this study attempts to analyze stress distribution between resin and tooth structure which is generated during polymerization shrinkage of composite resin using three dimensional finite element method. Three dimensional finite element models with conventional box-shape cavity and erosion/abrasion type V-shape lesion cavity in upper central incisor were developed. These cavities were filled with four different types of placement techniques. (bulk filling, horizontal increment filling, oblique occlusal increment filling, oblique gingival increment filling) The stresses generated by polymerization shrinkage of composite resin were calculated. The results analyzed with three dimensional finite element method were as follows : 1. The increment filling technique showed the highest maximum normal stress in both conventional box-shape and V-shape cavities and showed a tendency to decrease after complete polymerization. 2. The bulk filling technique resulted in increased stresses during the curing process in both conventional box-shape and V-shape cavities and the highest maximum normal stress occurred after complete polymerization. 3. The bulk filling resulted in the lowest maximum normal stress in both box-shape and V-shape cavities 4. Regardless of placement method, in conventional box-shape cavity, the maximum normal stress increased in dentin floor, enamel, dentin sequence and in V-shape cavity, the maximum normal stress increased in enamel, dentin sequence.

  • PDF

A SCANNING ELECTRON MICROSCOPIC EVALUATION OF THE ROOT CANAL FILLING WITH ULTRASONIC ENDODONTIC INSTRUMENT (초음파 근관기구를 이용한 근관충전법의 근관폐쇄능에 관한 주사 전자현미경적 연구)

  • Choi, La-Young;Lee, In-Sook
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.2
    • /
    • pp.104-114
    • /
    • 1990
  • The purpose of this study was to evaluate the adaptation of root canal filling material to the dentinal wall of root canal and to compare the sealing ability of the root canal filling materials using ultrasonic endodontic instrument with injection-molded thermoplasticized gutta-percha filling method and lateral condensation method. Fifty fresh human single root exlracted for orthodontic treatment, were randomly selected, and instrumented by step-back technique. And then, the teeth were divided into 5 groups according to each root canal filling methods. In the experimental group 1 and group 2, the root canals were filled with gutta perdia cases using ultrasonic instrument with and without sealer. In the experimental group 3 and 4, using jection-moldeed thermoplasticized gutta-percha method by obtul$^{(R)}$ canals were filled with and without sealer. In the control group, the canals were filled with sealer by lateral candensation. And then, 5 teeth of each group were immersed in black Indian ink, decalcified and cleared. The depth of dye penetration into the root canal were evaluated with stereoscope (Reichert Ltd., USA). Among the 5 teeth remaining in each group, the single longituding grooves were made on the labial and lingual root surfaces and then immersed in the liquid nitrogen to fracture the teeth spontaneously without any distortions of gutta-percha. Each specimens were examined with X-650 Scanning Electron Microscope(Hitachi ltd, Japan) to show the adaptation to the canal wall, void, homogenicity of filling material and location of gutta-percha or sealer in the dentinal tubules of the root canal. The observations were as follows : 1. The experimental group 1 showed smaller mean dye penetration than control group, and showed the penetraton of sealer in the dentinal tubules of apical third of the root canal. 2. The experimental group 2 and group 4 showed the penetration of gutta-percha in the dentinal tubules of root canals. 3. The experimental group 1 and group 3 showed less mean dye penetration than the experimental group 2 and group 4. 4. The experimental group 1 and group 2 showed better adaptation of filling materials than control group.

  • PDF

Efficient Signal Filling Method Using Watershed Algorithm for MRC-based Image Compression (MRC 기반의 영상 부호화를 위한 분수령 알고리즘을 이용한 효과적인 신호 채움 기법)

  • Park, Sang-Hyo;Lee, Si-Woong
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.2
    • /
    • pp.21-30
    • /
    • 2015
  • Image coding based on mixed raster content model generates don't care regions (DCR) in foreground and background layers, and its overall coding performance is greatly affected by region filling methods for DCRs. Most conventional methods for DCR filling fail in utilizing the local signal properties in hole regions and thus the high frequency components in non-DCR regions are reflected into DCR after signal filling. In addition, further high frequency components are induced to the filled signal because of signal discontinuities in the boundary of DCR. To solve this problem, a new DCR filling algorithm using the priority-based adaptive region growing is proposed in this paper. The proposed method uses the watershed algorithm and the flooding priority of each pixel for region filling is determined from the degree of smoothness in the neighborhood area. By growing the filled region into DCR based on the computed priority, the expansion of high-textured area can be minimized which can improve the overall coding performance. Experimental results show that the proposed method outperforms conventional algorithms.

A STUDY ON THE MARGINAL LEAKAGE OF CLASS II LIGHT CURING COMPOSITE RESIN RESTORATION ACCORDING TO FILLING METHODS (2급와동 광중합 복합레진의 충전방법에 따른 변연누출에 관한 실험적 연구)

  • Kim, Kyung-Hyun;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.55-72
    • /
    • 1993
  • The aim of this study was to compare the marginal leakage of class II light curing composite resin restoration according to filling methods. With using acid etching technique and dentin bonding agent, various methods were suggested to eliminate or reduce the marginal leakage. In this study, class II cavities were prepared in 100 extracted human premolars with cementum margin(1mm below the CEJ) and the teeth were randomly assigned to 5 groups of 20 teeth each. The teeth in group 1, 2, 3 and 4 were restored by direct filling methods using P-50 and Clearfil Photoposterior of 10 teeth each, but the method of insertion of the restorative materials varied with each group. And the teeth in group 5 were restored by inlay method using Kulzer Inlay and CR Inlay. Filling methods are as follows : Group 1 : The composite resin was inserted in one layer in the proximal box and one layer in the occlusal portion. Group 2 : Insertion was in two equally thick horizontal layers in the proximal box. Group 3 : Insertion was in two diagonally placed layers in the proximal box. Group 4 : The composite resin was inserted in the same way as in group 3 except that a glass ionomer liner was first placed on the axial wall and gingival floor. Group 5 : The teeth were restored by Inlay technique using dure cure resin cement. All the teeth were thermocycled, stained with 1 % methylene blue solution, sectioned mesiodistally, and scored for marginal leakage. To compare the marginal leakage, ANOVA and T-test were used in analysis. The following results were obtained : 1. In direct filling methods, there was no significant difference in marginal leakage at both occlusal and cervical margins. 2. In all groups, occlusal margin showed significantly less leakage than cervical margin. 3. In group using glass ionomer liner, there was no significant reduction of marginal leakage at the cervical margin. 4. The group restored by inlay method showed significantly less marginal leakage than groups restored by direct filling methods at both occlusal and gingival margins. 5. There was no significant difference in each group according to filling materials.

  • PDF

AN ELECTROCHEMICAL STUDY ON MICROLEAKAGE OF RETROGRADE FILLING USING DIFFERENT RETROGRANE FILLING MATERIALS, ROOT RESECTION ANGLE AND CAVITY PREPARATION INSTRUMENTS (역충전재 및 치근단 절제 각도와 와동 형성 기구에 따른 역충전물의 변연 누출에 관한 전기화학적 연구)

  • Kim, Jin-Woo;Lim, Sung-Sam
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.499-512
    • /
    • 1994
  • The purpose of this study was to evaluate the microleakage electrochemically using different retrograde filling materials, different root resection angle, and different cavity preparation instruments. 104 extracted single-rooted teeth were selected for this study. 100 teeth were used as experimental groups and four was used as controls. Anatomical crowns were resected, root canals were prepared, and the apical 2 mm of roots were removed. The experimental roots were randomly divided into five equal groups. Experimental groups : Group 1. no bevel, cavity preparation with ultrasonic instruments, amalgam filling Group 2. no bevel, cavity preparation with ultrasonic instruments, SuperEBA cement filling Group 3. no bevel, cavity preparation with ultrasonic instruments, desiccated ZOE filling Group 4. $45^{\circ}$ bevel, cavity preparation with ultrasonic instruments, amalgam filling Group 5. no bevel, cavity preparation with conventional bur, amalgam filling Microleakage was measured once a day for 30 days using electrochemical method and were analyzed statistically. The results were as follows : 1. The group with Super EBA cement filling showed the least marginal leakage from second to fourth day(p<0.05), there was no significant difference between the group with amalgam filling during eighth to eighteenth day(p>0.05), but after the nineteenth day here was a higher marginal leakage than the group with amalgam filling(p<0.05). 2. The group with desiccated ZOE filling demostrated that the highest marginal leakage, started on the eighth day(p<0.05). 3. The group using ultrasonic instrument showed lower marginal leakage than the group using bur until the nineteenth day(p<0.05), but there was no significant differnce with the group using bur after twentythird day(p>0.05). 4. The group without bevel showed lower marginal leakage than the group with bevel (p<0.05). 5. Whether bevel or nor had much more effect on marginal leakage than with cavity perparation instrument when the cavity was retrogrdefilled with amalgam(stepwise regression).

  • PDF

Hole-Filling Method for Depth-Image-Based Rendering for which Modified-Patch Matching is Used (개선된 패치 매칭을 이용한 깊이 영상 기반 렌더링의 홀 채움 방법)

  • Cho, Jea-Hyung;Song, Wonseok;Choi, Hyuk
    • Journal of KIISE
    • /
    • v.44 no.2
    • /
    • pp.186-194
    • /
    • 2017
  • Depth-image-based rendering is a technique that can be applied in a variety of 3D-display systems. It generates the images that have been captured from virtual viewpoints by using a depth map. However, disoccluded hole-filling problems remain a challenging issue, as a newly exposed area appears in the virtual view. Image inpainting is a popular approach for the filling of the hole region. This paper presents a robust hole-filling method that reduces the error and generates a high quality-virtual view. First, the adaptive-patch size is decided using the color and depth information. Also, a partial filling method for which the patch similarity is used is proposed. These efforts reduce the error occurrence and the propagation. The experiment results show that the proposed method synthesizes the virtual view with a higher visual comfort compared with the existing methods.