• 제목/요약/키워드: fillers

검색결과 695건 처리시간 0.025초

유기/무기 복합 절연재료의 전기적 특성 (Electrical Properties of Organic/lnorganic Hybrid Composites for Insulation materials)

  • 깅상철;김현석;옥정빈;안명진;박도현;이건주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.78-83
    • /
    • 2001
  • In this work, the surface of inorganic fillers were modified with some functional groups such as stearic acid, aliphatic long chain, vinylsilane and aminosilane to control the interaction between inorganic fillers and polymer matrix. Ethylene-vinyl acetate copolymers (EVA) with various amount of vinyl-acetate content and copolyether-ester elastomer were used as polymer matrix. The addition of inorganic fillers increases flame retardancy, but results in steep drop of electrical and mechanical properties, which may be caused by the defect in the interface between organic/inorganic hybrid composites. The hybrid composites are found to show better mechanical properties and higher volume resistivities as inorganic fillers are well dispersed and have good adhesion with polymer matrix. Also, the most effective type of functional group coated on fillers depends on the chemical structure of polymer.

  • PDF

Feasibility on Fillers for Bismate Glass System Used for Etching Process in Barrier-Ribs

  • Sung, Woo-Kyung;Jeon, Jae-Sam;Chong, Eu-Gene;Kim, Hyung-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.938-941
    • /
    • 2006
  • It is suggested that the bismate glass system is one of alternatives to the lead glass for barrier-ribs in PDP. Moreover it is necessary to investigate the resultant change in properties with addition of ceramic fillers. Glass frit was selected to be a $Bi_2O_3-ZnO-B_2O_3-Al_2O_3$ and two fillers, ZnO and $Al_2O_3$ were added into a glass matrix with the different content. We investigated thermal, chemical properties of bismate glass system with two different fillers. We confirmed that addition of fillers effects properties of composites such as the thermal expansion coefficient, etching mechanism.

  • PDF

플라즈마 코팅된 실리카와 에폭시 수지간의 반응성 연구 (Study of Heat of Reaction Between Plasma Polymer Coated Silica Fillers and Biphenyl Epoxy Resin)

  • 김남일;강현민;윤태호
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 추계학술발표대회 논문집
    • /
    • pp.96-99
    • /
    • 2004
  • Silica fillers were coated by plasma polymer coatings of 1,3-diaminopropane, allylamine, pyrrole, 1,2-epoxy-5-hexene, allyl mercaptan and allyl alcohol using RF plasma (13.56 MHz). The coated fillers were then mixed with biphenyl epoxy, phenol novolac (curing agent) and/or triphenylphosphine (catalyst), and subjected to DSC analyses in order to elucidate the chemical reaction between functional moieties in the plasma polymer coatings and the epoxy resin. Only the samples with 1,3-diaminopropane and allylamine plasma polymer coated silica fillers showed heat of reaction peaks when they were mixed with biphenyl epoxy resin only, while these samples as well as the samples with 1,3-diaminopropane, allylamine and pyrrole plasma polymer coated silica fillers exhibited heat of reaction peaks when mixed with both biphenyl epoxy and phenol novolac (curing agent).

  • PDF

저온 회화법에 의한 무기물의 정량${\cdot}$정성분석 (Quantitative and Qualitative Analysis of Inorgainc Substances by Low Temperature Ashing)

  • 이종만;류정용;신종호;송봉근;오세균;신채호
    • 펄프종이기술
    • /
    • 제31권2호
    • /
    • pp.77-85
    • /
    • 1999
  • A study on the thermal stability of commonly used six fillers, such as titanium dioxide, silica, ground calcium carbonate, zeolite, and, clay, showed that most fillers except titanium dioxide were strongly effected by heat treatment. Therefore, the present methods for determination of ash in paper give weight loss due to thermal decomposition of fillers. It was found that a paper ashing method at a temperature of 40$0^{\circ}C$ allows most fillers in their original and undecomposed from. Results presented in this paper also show that X-ray diffraction can be used for qualitative determination of mixed fillers and coating pigments in a paper sheet.

  • PDF

"Cohesiveness of Hyaluronic Acid Fillers": Evaluation Using Multiple Cohesion Tests

  • Kyun Tae Kim;Won Lee;Eun-Jung Yang
    • Archives of Plastic Surgery
    • /
    • 제51권1호
    • /
    • pp.14-19
    • /
    • 2024
  • Background Hyaluronic acid fillers can be manufactured using various processes. They have multiple properties, including their concentration, degree of modification, and rheological data. Cohesion is one such property to evaluate gel integrity; however, there is no standardized method for calculating this parameter. This study aimed to evaluate different tests for calculating hyaluronic acid cohesion and discuss the importance of hyaluronic acid cohesion as a consideration when selecting fillers. Methods The cohesion levels of five different hyaluronic acid fillers with different rheological properties were evaluated and compared using the drop weight, compression, tack, and dispersion time tests. Results The cohesion tests yielded different results in the samples. Samples 2 and 4 showed approximately two times the number of droplets when compared with Sample 5 in drop weight test. Samples 1, 2, 3, and 4 were superior to Sample 5 in tack test. Samples 1, 2, and 3 showed cohesive appearances at 95 seconds in most cases in dispersion test. Rheological test results did not reflect the measures of cohesion. Conclusion Although there are no definite standardized tests to evaluate the cohesion of hyaluronic acid fillers, our proposed tests showed similar results for different hyaluronic acid filler products. Further studies are needed to evaluate the cohesion of hyaluronic acid fillers and determine the clinical use of this distinguishing characteristic for clinicians selecting the product of choice. Level of evidence statement: These data are Level IV evidence.

충전재 종류에 따른 포장용 포러스 폴리머 콘크리트의 강도 및 투수 특성 (Strengths and Permeability Properties of Porous Polymer Concrete for Pavement with Different Fillers)

  • 김영익;성찬용
    • 한국농공학회논문집
    • /
    • 제49권4호
    • /
    • pp.51-59
    • /
    • 2007
  • Recently, concrete has been made porous and used for sound absorption, water permeation, vegetation and water purification according to void characteristics. Many studies are carried out on the utilization of sewage sludge, fly ash and waste concrete to reduce the environmental load. This study was performed to evaluate the void, strength, relationship between void and strength, permeability and chemical resistance properties of porous polymer concrete for pavement with different fillers. An unsaturated polyester resin was used as a binder, crushed stone and natural sand were used as an aggregate and bottom ash, fly ash and blast furnace slag were used as fillers. The mix proportions were determined to satisfy the requirement for the permeability coefficient, $1{\times}10^{-2}$ cm/s for general permeable cement concrete pavement in Korea. The void ratios of porous polymer concrete with fillers were in the range of $18{\sim}23%$. The compressive strength and flexural load of porous polymer concrete with fillers were in the range of $19{\sim}22$ MPa and $18{\sim}24$ KN, respectively. The permeability coefficients of porous polymer concrete with fillers were in the range of $5.5{\times}10^{-1}{\sim}9.7{\times}10^{-2}$ cm/s. At the sulfuric acid resistance, the weight reduction ratios of porous polymer concrete immersed during 8-week in 5% $H_{2}SO_{4}$ were in the range of $1.08{\sim}3.56%$.

Reliable Anisotropic Conductive Adhesives Flip Chip on Organic Substrates For High Frequency Applications

  • Paik, Kyung-Wook;Yim, Myung-Jin;Kwon, Woon-Seong
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2001년도 Proceedings of 6th International Joint Symposium on Microeletronics and Packaging
    • /
    • pp.35-43
    • /
    • 2001
  • Flip chip assembly on organic substrates using ACAs have received much attentions due to many advantages such as easier processing, good electrical performance, lower cost, and low temperature processing compatible with organic substrates. ACAs are generally composed of epoxy polymer resin and small amount of conductive fillers (less than 10 wt.%). As a result, ACAs have almost the same CTE values as an epoxy material itself which are higher than conventional underfill materials which contains lots of fillers. Therefore, it is necessary to lower the CTE value of ACAs to obtain more reliable flip chip assembly on organic substrates using ACAs. To modify the ACA composite materials with some amount of conductive fillers, non-conductive fillers were incorporated into ACAs. In this paper, we investigated the effect of fillers on the thermo-mechanical properties of modified ACA composite materials and the reliability of flip chip assembly on organic substrates using modified ACA composite materials. Contact resistance changes were measured during reliability tests such as thermal cycling, high humidity and temperature, and high temperature at dry condition. It was observed that reliability results were significantly affected by CTEs of ACA materials especially at the thermal cycling test. Results showed that flip chip assembly using modified ACA composites with lower CTEs and higher modulus by loading non-conducting fillers exhibited better contact resistance behavior than conventional ACAs without non-conducting fillers. Microwave model and high-frequency measurement of the ACF flip-chip interconnection was investigated using a microwave network analysis. ACF flip chip interconnection has only below 0.1nH, and very stable up to 13 GHz. Over the 13 GHz, there was significant loss because of epoxy capacitance of ACF. However, the addition of $SiO_2filler$ to the ACF lowered the dielectric constant of the ACF materials resulting in an increase of resonance frequency up to 15 GHz. Our results indicate that the electrical performance of ACF combined with electroless Wi/Au bump interconnection is comparable to that of solder joint.

  • PDF

금속 보강재를 이용한 에폭시 수지형의 특성 향상 및 적용에 관한 연구 (A Study on Characteristics Improvement of Epoxy Resin Mold Using Metal Fillers and Its Application)

  • 정성일;임용관;김경래;정해도
    • 한국정밀공학회지
    • /
    • 제20권4호
    • /
    • pp.165-173
    • /
    • 2003
  • As the cycling time of new products have become more and more short in recent years, the demand for lowering the cost and reducing the production time becomes stronger. In order for the demand, the rapid prototyping and rapid tooling technology have been used. It has been widely known that RP technology has advantages with fabricating 3-D object having a complicated geometric shape. RP products, however, have a limitation with applying to the real die and mold because soft materials such as resin, paper and wax has been mostly used in RP technology. So in this paper, the RP products have been copied to semi-metallic soft tools using the mixture of metal fillers and epoxy resin. In order to evaluate the effect of the fillers on the characteristics of semi-metallic soft tools, three fillers are used including commercial aluminum powder, cast iron powder recycled by machining chips, and aluminum short fiber made by self-excited vibration technique. Besides, in the case of aluminum powder, the change of characteristics of semi-metallic soft tools is also tested according to the volume fraction of the powder.

하이브리드카본이 충전된 Poly(Phenylene Sulfide) 복합재 연료전지 분리판 특성 연구 (A Study on the Characteristics of the Hybrid Carbons Filled Poly(Phenylene Sulfide) Composite Bipolar Plates of Fuel Cell)

  • 김남훈;박옥경;이창노;이중희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.172-175
    • /
    • 2009
  • A bipolar plate is an important component in a fuel cell in the sense of cost and weight. This study aimed at developing highly conductive, lightweight, and low cost bipolar plates. Hybrid carbons filled poly(phenylene sulfide)(PPS) composite bipolar plates were prepared by using the compression molding technique. Various types and amounts of conducting carbon fillers such as graphite, carbon black, carbon fibers, and carbon nanotubes (CNTs) were adopted for the composites. Electrical conductivity and mechanical properties of the composites were measured in order to investigate effects of each components of fillers. When the graphite is only used as a conducting filler, the electrical conductivity of the composites increases with increasing the content, but the flexural strength decreases dramatically. However, for CNTs and carbon fibers, the flexural strength initially increases and then decreases with increasing the amount of the conducting fillers. The amount of graphite corresponding to the peak of flexural strength was moved to lower content with increasing the amount of CNTs or carbon fiber. When hybrid conducting fillers such as fibrous and particulate fillers were used, the synergy effect in mechanical and electrical properties was observed.

  • PDF

Radiographic study of dermal fillers in the facial area: A series of 3 cases

  • Kwon, Young-Eun;An, Chang-Hyeon;Choi, Karp-Shik;Lee, Du-Hyeong;An, Seo-Young
    • Imaging Science in Dentistry
    • /
    • 제48권3호
    • /
    • pp.227-231
    • /
    • 2018
  • In recent years, as interest in maintaining beauty and a youthful appearance has grown, filler procedures such as soft tissue augmentation have become more popular. These fillers are sometimes seen as radiopaque shadows on radiographic images, either due to the fillers themselves or because of secondary reactions; such findings may present a diagnostic challenge to dentists. The present report describes 3 cases of dermal fillers observed in panoramic and cone-beam computed tomographic (CBCT) images. All 3 elderly female patients had filler injected into their cheeks and chin area for cosmetic purposes decades ago. On panoramic images, multiple symmetric radiopacities were observed in the facial area; on CBCT, these calcifications were seen in the subcutaneous tissue in various shapes and with varying density. In conclusion, dentists should be aware of the imaging characteristics of dermal filler, and should be able to differentiate dermal filler from other pathological findings.