• 제목/요약/키워드: field measurements

검색결과 2,756건 처리시간 0.035초

60Hz 고압 송전선로의 자기장 발생범위에 대한 GIS 적용 방안에 대한 연구 (Study about the Applicable Plan of GIS on Range of Magnetic Field Emitted from 60 Hz Powerline)

  • 홍승철;최성호;김윤신;박재영
    • 환경영향평가
    • /
    • 제15권4호
    • /
    • pp.271-277
    • /
    • 2006
  • In this study, we investigated the applicable plan of GIS on the environmental impact assessment of 60 Hz Powerline. So we assessed distance data based on calculations by use of 2D and 3D Geographical information systems(GIS) and distance data based on measurements on 1: 5000 maps accord with on site distance measurements to use input data for calculating magnetic field. One hundred eight of the on site measured addresses were selected from residences. The data were achieved by measuring the distance between residence and power line on maps with scales of 1: 5000. The digital map was obtained from National Geographic Information Institute with scales of 1: 5000, and we made 2D and 3D map. Correlation analyses were performed for statistical analyses. For the 3D GIS versus on site comparison of different exposure categories, 70 of 108 measurements were assigned to the correct category. Similarly for 2D GIS versus on site comparison, 71 of 108 were correctly categorized. When comparing map measurement with on site measurement, 62 of 108 were correctly categorized. When the correlation analysis was performed, best correlation was found between 3D GIS and on site measurements with r = 0.84947 (p<0.0001). The correlation between map and on site measurement yielded an r of 0.76517 (p<0.0001). Since the GIS measurements and map measurement were made from the center point in the building and the on site measurements had to be made from the closest wall on the building, this might introduce and additional error in urban areas. The difference between 2D and 3D calculations were resulted from the height of buildings.

전자파와 수표면 영상을 이용한 산지하천 홍수유량 및 유속 계측 비교 연구 (Comparison of Flood Discharge and Velocity Measurements in a Mountain Stream Using Electromagnetic Wave and Surface Image)

  • 양성기;김동수;류권규;강명수;정우열;이준호;김용석;유호준
    • 한국환경과학회지
    • /
    • 제21권6호
    • /
    • pp.739-747
    • /
    • 2012
  • Due to the difficulties for measuring flood discharge in the dangerous field conditions, conventional instruments with relatively low accuracy such as float still have been widely utilized for the field survey. It is also limited to use simple stage-discharge relationship for assessment of the flood discharge, since the stage-discharge relationship during the flood becomes complicated loop shape. In recent years, various non-intrusive velocity measurement techniques such as electromagnetic wave or surface images have been developed, which is quite adequate for the flood discharge measurements. However, these new non-intrusive techniques have little tested in the flood condition, though they promised efficiency and accuracy. Throughout the field observations, we evaluated the validity of these techniques by comparing discharge and velocity measurements acquired concurrently during the flood in a mountain stream. As a result, the flood discharge measurements between electromagnetic wave and surface image processing techniques showed high positive relationship, but velocities did not matched very well particularly for the high current speed more 3 m/s. Therefore, it should be noted here that special cares are required when the velocity measurements by those two different techniques are used, for instance, for the validation of the numerical models. In addition, authors assured that, for the more accurate flood discharge measurements, velocity observation as well as stage height is strongly necessary owing that the unsteady flow occurs during the flood.

고기압 $SF_{6}$가스에서 전극표면 상태가 절열파괴 강도에 미치는 영향 (Influence of electrode surface conditions on breakdown field strength in pressurized $SF_{6}$)

  • 이동인
    • 전기의세계
    • /
    • 제30권3호
    • /
    • pp.172-176
    • /
    • 1981
  • The reduction in the breakdown field strength due to electrode surface roughness was calculated by applying the streamer breakdown criterion and the surface roughness factor, and measurements of static breakdown voltage for a gap with an artificial protrusion were made under the uniform field at pressures up to 4 bar in pressurized $SF_{6}$. The effect of polarity of highly stressed electrode on the breakdown field strength was also investigated. The measurements have shown that the measured breakdown levels for a protrusion located on the cathode agree with those calculated and the values measured with an identical anode protrusion are substantially higher and more scattered. This may be explained if it assumed that a high rate of production of initiatory electrons is maintained at the tip of a cathode protrusion by field emission. In practical point of view, the breakdown levels in pressurized $SF_{6}$ can be bereliably estimated from the values calculated.

  • PDF

On-the-go Soil Strength Profile Sensor to Quantify Spatial and Vertical Variations in Soil Strength

  • Chung, Sun-Ok;Sudduth, Kenneth A.
    • Agricultural and Biosystems Engineering
    • /
    • 제6권2호
    • /
    • pp.39-46
    • /
    • 2005
  • Because soil compaction is a concern in crop production and environmental pollution, quantification and management of spatial and vertical variability in soil compaction for soil strength) would be a useful aspect of site -specific field management. In this paper, a soil strength profile sensor (SSPS) that could take measurements continuously while traveling across the field was developed and the performance was evaluated through laboratory and field tests. The SSPS obtained data simultaneously at 5 evenly spaced depths up to 50 em using an array of load cells, each of which was interfaced with a soil-cutting tip. Means of soil strength measurements collected in adjacent, parallel transects were not significantly different, confirming the repeatability of soil strength sensing with the SSPS. Maps created with sensor data showed spatial and vertical variability in soil strength. Depth to the restrictive layer was different for different field locations, and only 5 to 16% of the tested field areas were highly compacted.

  • PDF

뇌 확산강조 자기공명영상에 대한 정량적, 성적 평가: 1.5 T와 3.0 T 기기 비교 (Quantitative and Qualitative Evaluation of Brain Diffusion Weighted Magnetic Resonance Imaging: Comparision with 1.5 T and 3.0 T Units)

  • 구은회;동경래
    • 방사선산업학회지
    • /
    • 제10권4호
    • /
    • pp.227-230
    • /
    • 2016
  • DWI of biological effects are independent of magnetic field strength in various regions. High field strength, however, does affect the signal to noise ratio (SNR) and artifacts of diffusion weighted imaging (DWI) images, which ultimately will influence the quantitative of diffusion imaging. In this study, the effects of field strength on DWI are reviewed. The effects of the diseases also are discussed. Comparing DWI in cerebellum, WM, GM, Hyperacute region measurements both as a function of field strength (1.5T and 3.0T). Overall, the SNR of the DWI roughly doubled going from 1.5 T to 3.0 T. In summary, DWI studies at 3.0 T is provided significantly improved DWI measurements relative to studies at 1.5T.

현장계측을 통한 T-4 천공과 암반 이중천공의 비교·분석 (Comparative Analysis between T-4 Drilling and Dual Drilling Methods through Field Measurements)

  • 손무락;이종우;서정호;김종모
    • 한국지반환경공학회 논문집
    • /
    • 제17권9호
    • /
    • pp.13-20
    • /
    • 2016
  • 본 연구에서는 PRD 방식으로 암반천공을 위해 사용되는 두 공법, 즉 T-4 천공 공법과 암반 이중천공 공법에 대한 현장계측을 실시하고 각 공법의 적용으로부터 발생된 진동, 소음, 천공속도 및 천공수직도를 조사하였으며 그 결과를 비교 및 분석하였다. 이를 바탕으로 두 공법에 관한 관련 계측자료를 제공하고 그 차이점을 파악하여 향후 암반천공으로 인한 주변 민원피해를 최소화하고 천공의 효율을 향상 시키고자 함에 그 목적이 있다. 본 연구에서 제한된 현장계측을 토대로 비교한 결과 암반 이중천공 공법이 T-4 천공 공법에 비해서 진동 및 소음이 보다 작게 발생하는 특징을 나타냈으며 이와 더불어 천공속도와 천공수직도는 더 양호한 특징을 가지는 것으로 나타났다.

로렌츠 상호작용 원리와 근역장-원역장 변환 공식을 이용한 안테나 근역장 측정 알고리즘 개선 (The Enhancement of Antenna Near-Field Measurements Using Near-Field to Far-Field Transform Algorithms Based on the Lorentz Reciprocity Theorem)

  • 조용희
    • 한국콘텐츠학회논문지
    • /
    • 제6권2호
    • /
    • pp.51-58
    • /
    • 2006
  • 안테나 복사 특성을 효과적으로 측정하는 방법 중 하나인 안테나 근역장 측정 알고리즘의 개선을 논한다. 로렌츠 상호작용 원리와 상호작용 표기법을 이용하여 근역장-원역장 변환공식의 핵심인 프로브 교정 알고리즘을 간략히 유도한다. 제안된 일반적인 프로브 교정 방정식과 제작된 시스템을 사각 혼안테나에 대한 평면주사법에 적용하여 근역장 복사 패턴을 얻고 이를 원역장 복사 패턴과 비교하여 복사 특성이 유사한 것을 보인다. 이를 통해 본 논문의 접근법이 매우 간단하면서도 대부분의 안테나 측정에 유용하게 쓰일 수 있는 것을 보인다.

  • PDF

The Effects of Dielectric Coatings on Electron Emission from Tungsten

  • Al-Qudah, Ala'a M.;Alnawasreh, Shady S.;Madanat, Mazen A.;Trzaska, Oliwia;Matykiewicz, Danuta;Alrawshdeh, Saad S.;Hagmann, Mark J.;Mousa, Marwan S.
    • Applied Microscopy
    • /
    • 제47권1호
    • /
    • pp.36-42
    • /
    • 2017
  • Field electron emission measurements were performed on dielectric-coated tungsten emitters, with apex radii in the nanometer and micrometer range, which were prepared by electrochemical etching in NaOH solution. Measurements were performed in a field electron microscopy (FEM) with a base pressure <$10^{-6}$ Pascal ($10^{-8}$ mbar). Four different types of dielectric were used, namely: (1) Clark Electromedical Instruments epoxylite resin, (2) Epidian 6 produced by Ciech Sarzyna S. A., (3) a Radionox solution of colloidal graphite; and (4) Molyslip 2001 E compound ($MoS_2$ and MoS). Current-voltage measurements and FEM images were used to investigate the characteristics of these composite emitters, and to assess how the different types of dielectric coating affect the suitability of the composite emitter as a potential electron source.

복개 터널구조물의 현장 시공에 따른 계측 분석 사례 (Field Measurements with the Construction of Cut and Cover Tunnel)

  • 박시현;이석원;이규필;배규진;전오성;이종성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.149-156
    • /
    • 2002
  • Field measurements were carried out in this study to investigate the behavior of cut and cover tunnel such as the distribution and the magnitude of the earth pressure during back fill process of the ground material. Three kinds of measuring instruments, such as the earth pressure load cell, the concrete strain gauge and the reinforcing bar meter of embedded type in concrete structure were installed and measured. Earth pressure load cells, installed after construction of the tunnel lining, measure the outside forces acting on the tunnel lining with radial directions. Three load cells were installed at the crown, the right and the left shoulder of the tunnel, respectively. Three sets of reinforcing bar meter were installed in the double reinforcements of the tunnel lining and their locations were the same with the position of the earth pressure load cells. Concrete strain gauge was installed only one site of the upper compressive part at the tunnel crown. Based on the measuring results in the field, the deformation and the earth pressure acting on the tunnel lining were investigated with the back fill process of the ground material. Considerations on the validity of the measuring results were paid. For the analysis of measurements, after dividing back fill process into three steps, various factors which affect on the behavior of tunnel lining were investigated at each step.

  • PDF

Field measurements of natural periods of vibration and structural damping of wind-excited tall residential buildings

  • Campbell, S.;Kwok, K.C.S.;Hitchcock, P.A.;Tse, K.T.;Leung, H.Y.
    • Wind and Structures
    • /
    • 제10권5호
    • /
    • pp.401-420
    • /
    • 2007
  • Field measurements of the wind-induced response of two residential reinforced concrete buildings, among the tallest in the world, have been performed during two typhoons. Natural periods and damping values have been determined and compared with other field measurements and empirical predictors. Suitable and common empirical predictors of natural period and structural damping have been obtained that describe the trend of tall, reinforced concrete buildings whose structural vibrations have been measured in the collection of studies in Hong Kong compiled by the authors. This data is especially important as the amount of information known about the dynamic parameters of buildings of these heights is limited. Effects of the variation of the natural period and damping values on the alongwind response of a tall building for serviceability-level wind conditions have been profiled using the gust response factor approach. When using this approach on these two buildings, the often overestimated natural periods and structural damping values suggested by empirical predictors tended to offset each other. Gust response factors calculated using the natural periods and structural damping values measured in the field were smaller than if calculated using design-stage values.