• 제목/요약/키워드: field inhomogeneity

검색결과 107건 처리시간 0.026초

3.0 T MRI를 위한 Parallel-Transmission RF 코일 구조의 비교와 최적화 (Comparison and Optimization of Parallel-Transmission RF Coil Elements for 3.0 T Body MRI)

  • 오창현;이흥규;류연철;현정호;최혁진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.61-63
    • /
    • 2007
  • In high field (> 3 T) MR imaging, the magnetic field inhomogeneity in the target object increases due to the nonuniform electro-magnetic characteristics and relatively high Larmor frequency. Especially in the body imaging, the effect causes more serious problems resulting in locally high SAR(Specific Absorption Ratio). In this paper, we propose an optimized parallel-transmission RF coil element structure and show the utility of the coil by FDTD simulations to overcome the unwanted effects. Three types of TX coil elements are tested to maximize the efficiency and their driving patterns(amplitude and phase) optimized to have adequate field homogeneity, proper SAR level, and sufficient field strength. For the proposed coil element of 25 cm ${\times}$ 8 cm loop structure with 12 channels for a 3.0 T body coil, the 73% field non-uniformity without optimization was reduced to about 26% after optimization of driving patterns. The experimental as well as simulation results show the utility of the proposed parallel driving scheme is clinically useful for (ultra) high field MRI.

  • PDF

뇌기능 영상을 위한 TRFGE와 CGE 기법에서 자화율 효과의 정량적 해석 (Quantitative Analysis of Susceptibility Effects in TRFGE and CGE Sequences for Functional MRI)

  • 정순철;노용만;조장희
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.66-74
    • /
    • 1997
  • 혈액의 산소화와 불 산소화에 따른 국부적인 자화율 효과의 변화에 의한 자장의 불 균일성에 민감한 경사 자장 에코 기법은 현재의 뇌기능 MR 영상의 기본이 되고 있다. 일반적으로 이러한 경사 자장 에코기법은 $T2^{*}$ 혹은 BOLD효과에 의한 자장의 불 균일성의 증가가 신호의 감소로 나타난다. BOLD 효과는 주자장에 대한 핏줄의 방향이나 영상 형식, 즉, 횡단면, 관상면, 또는 시상면에 따라 달라진다. 그래서 영상 형식과 영상면에 대한 기울임 각에 따른 신호의 변화와 BOLD 효과의 변화에 대한 정량적인 연구를 하였다. 연구는 자화율 효과에 대해 다른 민감도를 가지는 TRFGE 와 CGE 기법으로 이루어졌다. 컴퓨터 모의 실험과 실험 결과를 본 논문에 나타내었다.

  • PDF

6MV X-선에 대한 조직 보상체의 제작 및 응용에 관한 연구 (A Study on Design and Application of Tissue Compensator for 6MV X-rays)

  • 채규영;최은경;정웅기;강위생;하성환;박찬일
    • Radiation Oncology Journal
    • /
    • 제7권1호
    • /
    • pp.123-132
    • /
    • 1989
  • A radiation beam incident on an irregular or sloping surface produces the non-uniformity of absorded dose. The use of a tissue compensator can partially correct this dose inhomogeneity. The tissue compensator is designed based on the patient's three dimensional contour. After required compensator thickness was determined according to tissue deficit at $25cm\pm25cm$ field size, 10cm depth for 6MV x-rays, tissue deficit was mapped by isoheight technique using laser beam system. Compensator was constructed along the designed model using 0.8mm lead sheet or 5mm acryl plate. Dosimetric verification were peformed by film dosimetry using humanoid phantom. Dosimetric measurements were normalized to central axis full phantom readings for both compensated and non-compensated field. Without compensation, the percent differences in absorbed dose ranged as high as $12.1\%$ along transverse axis, $10.8\%$ along vertical axis. With the tissue compensators in place, the difference was reduced to $0\~43\%$ Therefore, it can be concluded that the compensator system constructed by isoheihnt technique can produce good dose distribution with acceptible inhomogeneity, and such compensator system can be effectively applied to clinical radiotherapy.

  • PDF

Coated conductor에서 임계전류의 불균일 (A unhomogeneity of critical current at the long length coated conductors)

  • 이남진;오상수;김호섭;하동우;하홍수;고락길;김태형;문승현;염도준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1-2
    • /
    • 2009
  • The high critical current ($I_c$, A) of SmBCO coated conductor in a magnetic field, the high production rate and the high material yield are promising for applications. The inhomogeneity of Ie at the long length coated conduct is very important problem for electric application. So we researched the reason of inhomogeneity of $I_c$ at long length tape prepared by batch type co-evaporation system called by EDDC. The long length SmBCO coated conductors were developed on $LaMnO_3/IBAD-MgO/Y_2O_3/Al_2O_3$/Hastelloy C276 template. The distribution of $I_c$ are from 0 to 397 A/cm at 77 K and self field. We have studied the microstructures of these films by using SEM, EDS and X-ray diffraction. The XRD and composition by EDS results of SmBCO film reveals subtle difference. But, the microscopic observation by SEM show the microcrack at the sample with low $I_c$.

  • PDF

Analysis of Solar Microwave Burst Spectrum, I. Nonuniform Magnetic Field

  • Lee, Jeongwoo
    • Journal of Astronomy and Space Sciences
    • /
    • 제35권4호
    • /
    • pp.211-218
    • /
    • 2018
  • Solar microwave bursts carry information about the magnetic field in the emitting region as well as about electrons accelerated during solar flares. While this sensitivity to the coronal magnetic field must be a unique advantage of solar microwave burst observations, it also adds a complexity to spectral analysis targeted to electron diagnostics. This paper introduces a new spectral analysis procedure in which the cross-section and thickness of a microwave source are expressed as power-law functions of the magnetic field so that the degree of magnetic inhomogeneity can systematically be derived. We applied this spectral analysis tool to two contrasting events observed by the Owens Valley Solar Array: the SOL2003-04-04T20:55 flare with a steep microwave spectrum and the SOL2003-10-19T16:50 flare with a broader spectrum. Our analysis shows that the strong flare with the broader microwave spectrum occurred in a region of highly inhomogeneous magnetic field and vice versa. We further demonstrate that such source properties are consistent with the magnetic field observations from the Michelson Doppler Imager instrument onboard the Solar and Heliospheric Observatory (SOHO) spacecraft and the extreme ultraviolet imaging observations from the SOHO extreme ultraviolet imaging telescope. This spectral inversion tool is particularly useful for analyzing microwave flux spectra of strong flares from magnetically complex systems.

Defects Nucleation in the Liquid Crystal Director Field from Inhomogeneous Surface

  • Lee, Gi-Dong;Lee, Jong-Wook;Ko, Tae-Woon;Lee, Joun-Ho;Oh, Chang-Ho;Choi, Hyun-Chul;Kim, Jae-Chang
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.1159-1162
    • /
    • 2004
  • A modeling of the nucleation and dynamical behavior of defects from an inhomogeneous surface configuration using fast Q-tensor method is realized. On modeling the defect nucleation and dynamics, A fast Q-tensor method is applied. From the numerical modeling, we confirmed that surface inhomogeneity which makes strong strain energy in the local liquid crystal director field could cause defects. Experimental result has compared with numerical modeling in order to verify the simulation of the defect nucleation.

  • PDF

분산형 복합재료의 손상 메커니즘 (Damage Mechanics in Particle or short-Fiber Reinforced Composite)

  • 조영태
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 추계학술대회 논문집
    • /
    • pp.287-292
    • /
    • 1998
  • In particle or short-fiber reinforced composites. cracking of the reinforcements is a significant damage mode because the broken reinforcements lose load carrying capacity. This paper deals with the load carrying capacity of intact and broken ellipsoidal inhomogeneities embedded in an infinite body and a damage theory of particle or short-fiber reinforce composites. The average stress in the inhomogeneity represents its load carrying capacity. and the difference between the average stresses of the intact t and broken inhomogeneities indicates the loss of load carrying capacity due to cracking damage. The composite in damage process contains intact and broken reinforcements in a matrix. An incremental constitutive relation of particle or short-fiber reinforced composites including the progressive cracking damage of the reinforcements have been developed based on the Eshelby's equivalent inclusion method and Mori and Tanaka's mean field concept. Influence of the cracking damage on the stress-strain response of the composites is demonstrated.

  • PDF

Modeling of Defects Nucleation in the Inhomogeneous Liquid Crystal Director Field

  • Lee Gi-Dong;Kim Jae Chang
    • Journal of the Optical Society of Korea
    • /
    • 제9권2호
    • /
    • pp.74-78
    • /
    • 2005
  • With the fast Q-tensor method, which can model the defect dynamics in a liquid crystal director field, the nucleation and dynamical behavior of defects is modeled. In order to model the defect, hormeotropic aligned liquid crystal cell with step inhomogeneous electrode which has a height of $1\;{\mu}m$ is used. From the simulation, we can observe the nucleation and line of the defect from surface inhomogeneity and the experiment is performed for confirmation. The experimental result is compared with numerical modeling in order to verify the simulation of the defect nucleation.

불균질 매질에 따른 인공 합성 탄성파 자료 비교 (Comparison of synthetic seismograms referred to inhomogeneous medium)

  • 김영완;장성형;윤왕중;서상용
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.197-202
    • /
    • 2007
  • Most of seismic reflection prospecting assumes subsurface formation to be homogeneous media. These models are not capable of estimating small scale heterogeneity which is verified by well log data or drilling core. And those synthetic seismograms by homogeneous media are limited to explain various changes at field data. So we developed a inhomogeneous velocity model which can estimate inhomogeneity of background medium to implement numerical modeling from homogeneous medium and inhomogeneous medium on the model. Background medium using three autocorrelation functions in order to generate inhomogeneous velocity media was according to dominant wavelength of background medium and correlation length of random medium. And then we compared shot gathers. The results show that numerical modeling implemented at inhomogeneous medium depicts complex wave propagation of field data.

  • PDF

불균일 자장 보정 후처리 기법을 이용한 간 영상에서의 지방 및 $T_2{^*}$ 측정 (Background Gradient Correction using Excitation Pulse Profile for Fat and $T_2{^*}$ Quantification in 2D Multi-Slice Liver Imaging)

  • 남윤호;김한성;조상영;김동현
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권1호
    • /
    • pp.6-15
    • /
    • 2012
  • 목적: 이 연구의 목적은 excitation pulse profile을 이용하여 불균일 자장에 의하여 발생하는 배경 경사 자장에 의한 영향을 보상하여 2차원 다중 단면 경사에코 간 영상에서의 정확한 지방 및 $T_2{^*}$ 측정을 하는 데에 있다. 대상과 방법: 2차원 경사에코영상에서 불균일 자장에 의한 배경경사자장으로 인하여 유도되는 신호의 감소는 excitation pulse profile weighting으로 나타난다. 이에 의한 영향을 최소화 하기 위하여 $B_0$ field map을 통하여 단면선택방향으로의 선형 경사자장의 정도를 추정한 후, 획득한 신호를 excitation pulse profile을 이용하여 보정하였다. $T_2{^*}$ 및 지방은 보정된 신호로부터 측정되었으며 보정방법은 3.0T 임상용 장비에서 팬텀 및 in vivo 실험을 통하여 이루어 졌다. 결과: 팬텀 실험 결과는 보정 후 측정된 $T_2{^*}$ 및 지방의 양이 자장이 균일한 경우에 가까워 진 것을 보여 주었다. In vivo 실험에서는 간에서 배경경사자장의 크기가 약 120 ${\mu}T/m$ 정도 까지로 나타났으며 보정하기 전에 비하여 측정된 $T_2{^*}$ 및 지방의 정도의 균일도가 높아지는 것을 확인할 수 있었다. 결론: Excitation pulse profile을 이용한 배경경사자장 보정 방법은 경사 에코 신호에서의 거시적인 불균일 자장에 의한 영향을 줄여 주며 2차원 간 영상에서의 적용을 통하여 보다 정확한 지방 및 $T_2{^*}$의 측정에 도움이 될 수 있다.