• 제목/요약/키워드: field homogeneity

검색결과 196건 처리시간 0.031초

환경 및 신뢰성 시험분야를 위한 숙련도시험 시료개발 연구 (A Study on Proficiency Test Sample Development for Environmental & Reliability Testing Field)

  • 박경환;이철규
    • 품질경영학회지
    • /
    • 제45권3호
    • /
    • pp.447-462
    • /
    • 2017
  • Purpose: This study aims to develop distributable samples that can be used for proficiency testing to verify the ability of the testing laboratory to perform high temperature and low temperature tests. Method: In this study, the temperature-resistance characteristics of the NTC thermistor were used to develop samples. The homogeneity and stability of samples were examined according to the proficiency testing requirements. Results: Thirty samples with homogeneity and stability were developed and used for the proficiency testing. Thus, it was possible to distinguish between the test laboratories that showed satisfactory results and those that did not. Conclusion: It was the first time to develop samples that can be used for proficiency testing in high temperature and low temperature tests. and it was proved that the proficiency test program can be operated using the characteristics of NTC thermistor.

68 cm 상온 보아를 갖는 MRI용 초전도마그네트에 관한 연구 (The Study on the Superconducting MRI Magnet of 68 cm in Room Temperature Bore)

  • 진흥범;오봉환;조전욱;오상수;권영길;하동우;이언용;김해종;김옥곤;최병주;류강식
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.142-146
    • /
    • 1996
  • In this paper, we present the main research results on the 2 Tesla class - superconducting MRI magnet which we have developed. Multi section type superconducting MRI main coil and various superconducting shims were designed and fabricated for obtaining the high field homogeneity, which is requested in the MR imaging. After assembling the magnet with room temperature bore cryostat field homogenity has been measured and analyzed by NMR field mapping system. According to this, field homogeneity of 22 ppm / 30 cm dsv was confirmed.

  • PDF

중력 데이터 해석과 드론원격정보를 이용한 지반의 다짐도 평가 (Evaluation of Soil Compaction Using Gravity Field Interpretation and UAV-based Remote Sensing Information)

  • 김성욱;최승찬;최은경;이영재;고대홍;이규환
    • 지질공학
    • /
    • 제31권3호
    • /
    • pp.283-293
    • /
    • 2021
  • 고해상 드론 기반의 지형 정보와 중력장 데이터를 이용하여 다짐지반의 모양과 균질성을 분석하였다. 지형과 수문 모형에서 계산된 지형요소 중 곡률은 다짐과정에서 발생한 지형의 변화를 효과적으로 보여 주었으며 이를 통해 불균질 다짐 영역을 확인할 수 있다. 지형 정보의 적정 해상도는 10 cm 정도였다. 성토지반의 공간적인 밀도변화를 분석하기 위해 중력장 해석을 수행하였으며 완전 부게이상의 변화로부터 불균질 다짐 영역과 지하 밀도구조 모델링을 통해 다짐도 차이에 의한 불균질 영역을 파악하였다. 연구결과로부터 지형요소와 중력장 해석법은 다짐된 지반의 균질성을 평가법이 될 수 있을 것으로 판단된다.

초전도 MRI 마그네트 국산화 개발 (The Domestic Development of a Superconducting MRI Magnet)

  • 배준한;심기덕;고락길;진홍범;조전욱;하동우;오상수;권영길;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.121-124
    • /
    • 2001
  • The research results on the superconducting magnet for whole body MRI are presented. The magnet consists of main coil with 6 solenoid coils, shielding coil with 2 solenoid coils and 6 sets of cryogenic shim coil. The ferromagnetic shim assembly is installed on the inside wall of the room temperature bore for shimming inhomogeneous field components generated due to manufacturing tolerances, installation misalignments and external ferromagnetic materials near the magnet. Also, the magnet is enclosed with the horizontal type cryostat with 80cm room temperature bore to keep the magnet under the operating temperature. The magnetic field distributions within the imaging volume were measured by the NMR field mapping system. Through the test, the central field of magnet was 1.5 Tesla and the field homogeneity of 9.3 ppm has been obtained on 40cm DSV(the diameter of spherical volume) and using this magnet, comparatively good images for human body, fruits and water phantoms have been achieved.

  • PDF

고균일자계 Double Helmholtz형 및 삼개분리 원통형키전동자석에 관한 연구 (A Study on Highly Homogeneous Double Helmholtz Superconducting Magnet and Newly Configurated Superconducting Magnet)

  • 이승원;권용안
    • 대한전기학회논문지
    • /
    • 제37권8호
    • /
    • pp.521-527
    • /
    • 1988
  • At present superconducting magnets have been feasible for many applications which require high field or highly homogeneous field that it is too difficult to be produced by conventional electromagnets. This paper is a stuny on Donble Helmholtz superconducting magnet and newly configurated superconducting magnet that realize highly homogeneous field with the minimum magnet volume. Nonlinear programming method is effectively used for the minimum volume of superconducting magnet that realizes the desired field intensity and high homogeneity. The results on Double Helmholtz and newly configurated superducting magnets that are presented in this paper are largely improved.

  • PDF

Design of Body RF Coil with Multiple Strips for Open MRI System by Pseudo Electric Dipole Radiation

  • 김경락;류승학;류연철;양형진;오창현
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.76-76
    • /
    • 2002
  • Purpose: The purpose of this study is to optimize the configuration of body RF coil composed of 4 planar subcoils for low field open MRI. Method: Our low field RE coil is composed of 4 subcoils assumed to be located at both the bottom and top sides of permanent magnet. Each subcoils has 3 main strips. The coil system has mirror inversion symmetry. First, the currents on the strips are obtained by inductance calculation and circuit analysis, Second, all the strips are divided into line strip elements across the strips, the self Inductances of line strip elements and the mutual inductances among the line strip elements are calculated, and current distributions of strip are obtained by circuit analysis, where each strip is considered as parallel combination of line strip elements. Finally all the line strip elements are segmented, magnetic field has been calculated by pseudo electric dipole radiation method, where the current elements are regarded as pseudo electric dipole radiation sources. We have performed above procedures for various configurations of RE coil. The field homogeneity is calculated in the 25 cm DSV.

  • PDF

Design and Implementation of Portable NMR Probe Magnet

  • Junxia, Gao;Yiming, Zhang;Jiashen, Tian
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.14-22
    • /
    • 2017
  • The NMR's probe consists of the static magnetic field generator (magnetic source) and the RF coil. It is very strict for the homogeneity of the static magnetic field intensity of the magnetic source, so the cost of the magnetic source is more expensive in the entire nuclear magnetic resonance instrument. The magnetic source generally consists of electromagnet, permanent magnet and superconducting magnet. The permanent magnet basically needs not to spend on operation and maintenance and its cost of manufacture is much cheaper than the superconducting magnet. Therefore, the permanent magnet may be the only choice for the static magnetic field device if we want to use the magnetic resonance instrument as an analyzer for production by reducing price. A new probe magnet was developed on the basis of the permanent magnet ring in this paper to provide a technological way for reducing the manufacturing cost, weight and volume of the existing nuclear magnetic resonance instrument (including MRI) probe.

Design of Low Field RF Coil for Open MRI System by Electric Dipole Radiation

  • 김경락;양형진;오창현
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.174-174
    • /
    • 2001
  • Purpose: Dimensions of body RF coil composed of 4 rectangular loops for low field open MRI hav been optimized. The design result shows the field inhomogeneity of B1 field below 1.5 dB in the 25 cm DSV can be achieved. Method: Our low field RF coil is composed of 4 rectangular strip loops that assumed to b located at both the bottom and top sides of permanent magnet. All the loops have identica dimensions and current amplitude. First, the inductance of a loop is calculated. Second, the current distribution on the coil strip is calculated by using finite difference time doma method (FDTD). It takes as much as 4 days in FDTD simulation for low frequency RF field That's why the electrical dipole radiation method is used for simulation. With the curren distribution obtained using the FDTD simulation, for various dimensional parameters th magnetic field has been calculated by electric dipole radiation method, where the curren elements are regarded as electric dipole radiation sources. The field pattern from electri dipole radiation is almost same as that from FDTD simulation. Also, it is same as that fro the result using the Viot-Savart equation, for far tone radiation term becomes zero and th Bl field amplitude of near one radiation is the same as the B field due to static current The field homogeneity is calculated in the 25 cm BSV.

  • PDF

Field gradient calculation of HTS double-pancake coils considering the slanted turns and the splice

  • Baek, Geonwoo;Kim, Jinsub;Lee, Woo Seung;Song, Seunghyun;Lee, Onyou;Kang, Hyoungku;Ko, Tae Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권1호
    • /
    • pp.51-55
    • /
    • 2017
  • To obtain Nuclear Magnetic Resonance (NMR) measurement of membrane protein, an NMR magnet is required to generate high intensity, homogeneity, and stability of field. A High-Temperature Superconducting (HTS) magnet is a promising alternative to a conventional Low-Temperature Superconducting (LTS) NMR magnet for high field, current density, and stability margin. Conventionally, an HTS coil has been wound by several winding techniques such as Single-Pancake (SP), Double-Pancake (DP), and layer-wound. The DP winding technique has been frequently used for a large magnet because long HTS wire is generally difficult to manufacture, and maintenance of magnet is convenient. However, magnetic field generated by the slanted turns and the splice leads to field inhomogeneity in Diameter of Spherical Volume (DSV). The field inhomogeneity degrades performance of NMR spectrometer and thus effect of the slanted turns and the splice should be analyzed. In this paper, field gradient of HTS double-pancake coils considering the slanted turns and the splice was calculated using Biot-Savart law and numerical integration. The calculation results showed that magnetic field produced by the slanted turns and the splice caused significant inhomogeneity of field.

자기장하에서 액막 초크랄스키 방법에 의한 단결정 성장에 관한 연구 (A Study on the Liquid Encapsulant Czochralski(LEC) Crystal Growth with Magnetic Fields)

  • 김무근;서정세
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1667-1675
    • /
    • 2001
  • Numerical simulations are carried out for the liquid encapsulant Czochralski(LEC) by imposing a magnetic field. The use of a magnetic field to the crystal growth is to suppress melt convection and to improve the homogeneity of the crystal. In the present numerical investigation, we focus on the range of 0-0.3Tesla strength for the axial and cusped magnetic field and the effect of the magnetic field on the melt-crystal interface, flow field and temperature distribution which are the major factors to determine the quality of the single crystal are of particular interest. For both axial and cusped magnetic field, increase of the magnetic field strength causes a more convex interface to the crystal. In general, the flow is weakened by the application of magnetic field so that the shape of the melt-crystal interface and the transport phenomena are affected by the change of the flow and temperature field.