• 제목/요약/키워드: field engineers

검색결과 11,907건 처리시간 0.041초

실차 시험을 통한 ER 현가장치의 성능평가 (Rerformance Evaluation of ER Suspensions Under Field Test)

  • 이헌균;최승복;한승직;장유진;이성범
    • 대한기계학회논문집A
    • /
    • 제24권2호
    • /
    • pp.347-354
    • /
    • 2000
  • This paper presents performance characteristics of a semi-active suspension featuring continuously variable ER (electro-rheological) dampers. These are evaluated through the field test of a passeng er car. Four ER dampers (two for front and two for rear part) are manufactured and their field-dependent damping properties are experimentally investigated. The damping force responses to step input fields are also identified by employing small size of high voltage amplifiers which are made adaptable to the field test. A skyhook controller considering the vertical, pitch and roll motions is formulated and incorporated with a car to be tested. The field test is then undertaken in order to evaluate both comfortability and steering stability showing bump, dive and squat responses.

논의 배수물꼬의 유량에 관한 기초연구 (A Study on the Outlet Drain Discharge from Paddy Field)

  • 최진규;김현영;손재권
    • 한국농공학회지
    • /
    • 제39권2호
    • /
    • pp.134-142
    • /
    • 1997
  • This study was performed to evaluate the drain runoff characteristics from one paddy field, and to provide the basic data required for the determination of flood discharge and unit drainage water for drainage improvement and farmland consolidation. For this purpose, under the assumption that drain discharge from paddy field was similar to outflow of reservoir, runoff model based on storage equation was applied to the experimental field, and simulated results were compared to the measured discharge at weir point. To estimate effective storage volume of paddy field with water depth, 4 regression formula were examined such as linear, exponential, power, and combined. From the observed runoff characteristics, it was shown to be 3.3~16.3${\ell}$/sec in weir discharge, 57.2~98% in runoff ratio, and relative error of simulated result was 3.0~39.4%, 8.5 ~56.0 % for peak flow and runoff ratio, respectively. Curve number by SCS method was calculated as mean value of 96.4 using measured rainfall and runoff data, it was considered relatively high because paddy field has generally flooding depth contrary to the upland watershed area.

  • PDF

고온초전도 BSCCO 팬케이크 권선에 인가되는 자장과 임계전류의 산정 (Estimation of the Magnetic Field and the Critical Current of HTS BSCCO Pancake Windings)

  • 구명환;강명훈;이희준;차귀수
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1970-1975
    • /
    • 2008
  • Critical current of the superconducting machines is limited by the magnetic field. When the magnetic field is not uniform, it is difficult to estimate the magnetic field and the critical current. This paper proposed a method for the estimation of the magnetic field and the critical current of the HTS pancake windings which can be used to generate the high field magnet. A parameter which was needed to calculate the critical current of a BSCCO magnet with 10 pancake windings was obtained by the experiment. Test which was carried out by using single pancake winding and magnet consisting of 10 pancake windings shows the proposed method can be an effective method for the estimation of the critical current of pancake windings.

반무한 전기 쌍극자층에 의한 정전계 해석과 앙페르 법칙에 자계와 커패시터의 누설 전계간의 이중성 유사 관계 (Electrostatic field of the semi-infinite electric dipole layer as (a) dual analogy to the Ampere's law (b) capacitor's fringing field)

  • 조영기;;손혁우;김현덕;유형석
    • 전기학회논문지
    • /
    • 제61권4호
    • /
    • pp.606-611
    • /
    • 2012
  • The similarity, analogy and equivalence between the phenomenon due to electric and magnetic dipoles have been discussed in the open literature for different situations. Here we are presenting the numerical proof of the trajectory of leakage electric field due to a semi-infinite electric dipole layer in the external periphery and the electric field in the space between oppositely charged surfaces. The result is also valid for the fringing electric field of a parallel plate capacitor. The result is also proved to be a dual of Amp$\grave{e}$re's law in the electrostatics due to a semi-infinite electric dipole layer.

2[MVA] 배전용 몰드변압기의 글라스넷 형상 최적설계 (Optimum Design of Glass Net in 2[MVA] Mold Transformer)

  • 전문호;김창업
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.107-112
    • /
    • 2011
  • In this paper, the optimum design of the glass net shape was studied to minimize the electric field of mold transformer. The glass net is used for reinforcement in structure between coils and epoxy, but it can cause to increase the electric field and the partial discharge. Therefore, the optimum design of glass net is required to minimize the electric field. In this paper, the objective function was approximated by using response surface method and then Zoom-in method was used for optimal design to minimize the electric field. The electric field was analysed using finite element method for each shape of glass nets.

교류자기장 차폐를 위한 자기장 상쇄장치 모델의 설계 (Design of Magnetic Field Compensation System Model for AC Magnetic Field Shielding)

  • 최학윤
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.78-82
    • /
    • 2011
  • In this paper, magnetic field compensation system with an open architecture and can be installed indoors is designed and measured by fabricated. To verify the shielding effectiveness, two rectangular helmholtz coils with 3-axis are fabricated to generate magnetic field and measured magnetic field inside compensation coil for 1~60[Hz], According to measurements, AC shielding effectiveness of compensation system is 96[%] of 1[Hz], 95[%] of 30[Hz] and 90[%] of 60[Hz]. The performance of system therefore can be used as the magnetically shielded room for medical and industrial field.

종자계형 진공인터럽터의 개발 (The Development of Axial Magnetic Field Type Vacuum Interrupter)

  • 박홍태;안희일;김성일;이경행
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.231-233
    • /
    • 2001
  • Axial magnetic field(AMF) type electrodes can be increase the interrupting capability of vacuum interrupters. Depending on the design, the principle of the local axial magnetic field arrangement are different. In this paper, a new AMF contact design based on a unipolar field arrangement and its characteristics are introduced. The influence of the unipolar AMF on the arc behavior is described by high-speed video camera. In addition, three-dimensional AMF simulations have been peformed by means of a finite element analysis(FEM) program to analyze the influence of magnetic field distribution on the AMF performance. The high interrupting capability of the unipolar AMF type electrode has been confirmed by three-phase test.

  • PDF

전계효과에 의한 칼코게나이드 박막에서의 광유기 복굴절 특성 (The Properties of Photoinduced Birefringence in Chalcogenide Thin Films by the Electric Field Effects)

  • 장선주;박종화;여철호;정홍배
    • 한국전기전자재료학회논문지
    • /
    • 제14권1호
    • /
    • pp.58-63
    • /
    • 2001
  • We have investigated the photoinduced birefrinence by the electric field effects in chalcogenide thin films. The electric field effects have investigated the various applied bias voltages(forward and reverse) in chalcogenide thin films. A pumping (inducing) and a probing bean were using a linearly polarized He-Ne laser light (633nm) and semiconductor laser light (780nm), respectively. The result was shown that the birefringence had a higher value in DC +2V than the others, Also, we obtained the birefringence in the electric field effects by various voltages. In addition, we have discussed the anisotropy property of chalcogenide thin films by the electric field effects.

  • PDF

수동루프 설치에 의한 송전선로 자계 저감 (Mitigation of Transmission Line Magnetic Field by Installation of Passive Shield-Loop.)

  • 김정부;신구용;신명철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권2호
    • /
    • pp.59-61
    • /
    • 2006
  • In our country most of transmission lines are double-circuit lines. In these lines, the combining method of increasing conductor height and installation of passive shield-loop to mitigate magnetic field near a transmission line, is a good and feasible method. The basic principle of passive shield loop is that the field from the current induced in the shield loop conductors counteracts the field from the phase conductors. This method applied to domestic transmission lines to meet the magnetic field level, 100, 30, 10 and 4 mG, respectively. In each magnetic field level, the minimum conductor height and passive loop height are presented for the implementation of the practical design.

일관장 개념의 평면변형률 요소에의 확장 (Extension of Field-Consistency to Plane Strain Elements)

  • 김용우
    • 대한기계학회논문집
    • /
    • 제19권8호
    • /
    • pp.1799-1809
    • /
    • 1995
  • The applicability of the field-consistency paradigm, which was originally employed for analysis of locking due to constrained energy having the second power of a strain, is extended to the constrained energy having a quadratic form of strain. For the extension, nearly-incompressible plane strain problem is considered by introducing the concept of reduced minimization. The field-consistent analysis of the plane strain problem leads to a clear and systematic understanding on the relation amongst constraints imposed on element, spurious constraint -free optimal points, and integration order used.