• 제목/요약/키워드: fiberglass

검색결과 130건 처리시간 0.034초

Basalt 섬유로 보강된 철근콘크리트 보의 휨 성능 고찰 (The Considerations on Flexural Performance of RC Beam Strengthened with Basalt Fibers)

  • 심종성;문도영;박성재;박경동
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.599-604
    • /
    • 2002
  • Fibers have been used to improve tile flexural performance of reinforced concrete. Therefore many different kinds of fibers have been developed and tested to reinforcing concrete. Basalt fiber is one of the recently developed materials for this purpose. Basalt fiber produced from this basalt raw material has high initial strength and durability. But, the main advantages of the basalt fiber are resistance to high operating temperatures and lower modulus and chemical resistance compared to fiberglass. Also basalt fiber may be consumed as a potential replacement for expensive carbon fibers.

  • PDF

FRP 보강 폴리머 모르터 패널의 역학적 특성 (Mechanical Properties of Polymer Mortar Panel Reinforced by FRP)

  • 유능환;연규석;김기성;이윤수;최동순
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.342-347
    • /
    • 1999
  • This study was initiated to develop a precast polymer concrete panel production method and to describe some engineering properties of FRP (Fiberglass Reinforced Plastics) reinforced polymer mortar. Specimens with different panel thickness and FRP reinforcement were prepared and tested and analyzed with respect to structural behaviors. Cracking moment was mostly affected by the thickness and reinforced FRP. Data of the study could be widely applied to the designing and planning of production processes of many polymer concrete products of which all or some of the components are composed with thin panels.

  • PDF

서울월드컵경기장 지붕구조물 설계와 시공 (The Roof Canopy for Seoul World Cup Stadium)

  • 문석용;;김형영
    • 기술사
    • /
    • 제34권5호
    • /
    • pp.29-33
    • /
    • 2001
  • This paper summarizes the design and construction of the roof canopy structure for the SEOUL 2002 World Cup Main Stadium with a design inspired by Korean traditional beauty emphasizing images of the Pangpae kite. The stadium has also been designed for maximization of its post-World Cup utility to be used on as every basis by the citizens. The stadium canopy is a unique spatial network of truss members with a tensile membrane roof suspended from 16 masts. The canopy covers 40,950 ㎡. which is clad with a pre-stressed tensile membrane of PTFE coated fiberglass fabric and the glass.

  • PDF

Development of an Optical Waveguide Loss Measuring System using an Rectangular Glass Probe

  • Choi, Young-Kyu
    • 센서학회지
    • /
    • 제10권1호
    • /
    • pp.71-79
    • /
    • 2001
  • The use of a glass-plate probe of rectangular shape is proposed for the measurement of transmission loss in optical waveguides. The light-collecting window is of a thin, rectangular shape and is perpendicular to the light streak, while the conventional fiberglass probe has a small circular face. This transversely elongated form results in a grate improvement of mechanical tolerance for the probe movement in the vortical as well as in the transverse direction. A theoretical investigation also presents a reasonable agreement with the experiments.

  • PDF

적층복합재료구조물의 변형에 미치는 제작조건과 작동조건의 영향에 대한 실험적 고찰 (Experimental Investigation of the Effect of Manufacturing and Working Conditions on the Deformation of Laminated Composite Structures)

  • 팜탄눗;염영진
    • Composites Research
    • /
    • 제26권4호
    • /
    • pp.265-272
    • /
    • 2013
  • 섬유강화플라스틱(Fiber-reinforced plastic, FRP)은 복합재료 보트를 만드는 데 주 구조물로 사용되고 그것들 대부분은 몰드에서 만들어진다. 이러한 제품들은 몰드에서 분리될 때나 높은 온도의 환경에서 변형이 생긴다. 그러므로 다양한 제작 및 작동 조건에서 적층복합재료 구조물의 변형에 대한 실험적 조사 및 평가는 필수적이다. 불포화 폴리에스테르수지와 유리섬유를 이용하여 L-shape과 Curve-shape 시편을 제작하였다. 경화제 비율과 제작온도, 네 가지 작동온도가 입력인자(독립변수)로 사용되었고 출력인자는 시편에서 측정되는 변형이다. 결과로부터 경화제 비율이 높을수록 또한 제작온도가 높을수록 변형이 작게 생김을 알 수 있었다. 작동온도가 상승할 때 초기 변형 값에 따라 큰 변화를 보였다. 또한 변형 값이나 입력인자들은 회귀 방정식으로부터 예측할 수 있었다.

망사 및 스틱 형태의 유리섬유 보강재를 삽입한 의치상용 레진의 굴곡강도 및 굴곡계수 비교 평가 (Comparative evaluation of flexural strength and modulus of denture base resin with mesh and stick type glass fiber reinforcement)

  • 김동연;김재홍
    • 대한치과기공학회지
    • /
    • 제42권2호
    • /
    • pp.91-98
    • /
    • 2020
  • Purpose: This study is to compare the flexural strength and modulus by inserting a mesh and stick type fiberglass reinforcement into resin specimens. Methods: Wax specimens (length 64 mm, width 39 mm, thickness 5 mm) are prepared according to ISO 20795-1:2013. Mesh type and stick type glass fiber reinforcements were prepared. The prepared wax specimens were used plaster and flask for investment. The flask was separated and the wax was removed. The heat curing resin was injected into the flask, and then a mesh type and stick type fiberglass reinforcement were inserted. The prepared resin specimen was cut into three equal parts (length 64 mm, width 10 mm, thickness 3.3 mm). The mesh type glass fiber reinforcement (MT group) and the stick type glass fiber reinforcement (ST group) were classified into two groups. The prepared specimen was measured using a universal testing machine (UTM). The data were analyzed by Mann-Whitney U test, and the significance level was set to 0.05. Results: In the flexural strength, the ST group was higher than the MT group, and there was a significant difference between the two groups (p<0.05). In the flexural modulus, the ST group was higher than the MT group, and there was a significant difference between the two groups (p<0.05). Conclusion: The stick-type glass fiber inreased the flexural strength than the mesh-type glass fiber reinforcement.

고성능 폴리머 재질의 포스트-코어 시스템의 생역학적 거동에 대한 예비실험 (A Preliminary study of Biomechanical Behavior of High-Performance Polymer Post-Core System)

  • 이기선;김종은;김지환;이정열;신상완
    • 대한심미치과학회지
    • /
    • 제27권2호
    • /
    • pp.75-81
    • /
    • 2018
  • 본 연구의 목적은 기존의 다른 포스트-코어 재료와의 유한요소분석(FEA)의 비교를 통한 치과용 포스트-코어 재료로서의 고성능 폴리머 PEKK의 생체역학 및 장기 안전성을 평가하는 데 있다. 상악 중절치를 모델링 하였으며, 구개 표면에서 치아의 장축에 $45^{\circ}$의 각도로 50N의 반복 하중을 가했다. 전통적으로 사용 된 포스트 코어 재료와 비교하기 위해 3가지 재료 (금, 유리 섬유 및 PEKK)를 시뮬레이션하여 결과를 상호 비교 해 보았다. 상아질보다 낮은 탄성 계수를 갖는 PEKK는 종래의 포스트 코어 재료보다 비교적 치근에 유리한 응력 분포를 보여 주었다. 그러나, PEKK 포스트-코어 시스템은 금속 또는 유리 섬유 포스트-코어 시스템보다 장기간의 반복하중에 대해 타락 및 크라운 파손의 가능성이 더 높을 가능성이 있다.

Comparison between a bulk-fill resin-based composite and three luting materials on the cementation of fiberglass-reinforced posts

  • Carlos Alberto Kenji Shimokawa ;Paula Mendes Acatauassu Carneiro ;Tamile Rocha da Silva Lobo;Roberto Ruggiero Braga ;Miriam Lacalle Turbino;Adriana Bona Matos
    • Restorative Dentistry and Endodontics
    • /
    • 제48권3호
    • /
    • pp.30.1-30.11
    • /
    • 2023
  • Objectives: This study verified the possibility of cementing fiberglass-reinforced posts using a flowable bulk-fill composite (BF), comparing its push-out bond strength and microhardness with these properties of 3 luting materials. Materials and Methods: Sixty endodontically treated bovine roots were used. Posts were cemented using conventional dual-cured cement (CC); self-adhesive cement (SA); dual-cured composite (RC); and BF. Push-out bond strength (n = 10) and microhardness (n = 5) tests were performed after 1 week and 4 months of storage. Two-way repeated measures analysis of variance (ANOVA), 1-way ANOVA, t-test, and Tukey post-hoc tests were applied for the push-out bond strength and microhardness results; and Pearson correlation test was applied to verify the correlation between push-out bond strength and microhardness results (α = 0.05). Results: BF presented higher push-out bond strength than CC and SA in the cervical third before aging (p < 0.01). No differences were found between push-out bond strength before and after aging for all the luting materials (p = 0.84). Regarding hardness, only SA presented higher values measured before than after aging (p < 0.01). RC and BF did not present 80% of the maximum hardness at the apical regions. A strong positive correlation was found between the luting materials' push-out bond strength and microhardness (p < 0.01, R2 = 0.7912). Conclusions: The BF presented comparable or higher push-out bond strength and microhardness than the luting materials, which indicates that it could be used for cementing resin posts in situations where adequate light curing is possible.

액체질소의 연면 방전 기초 특성 연구 (Basic Study on Characteristics of Surface Flashover in L$N_{2}$)

  • 정종만;백승명;김영석;김상현
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.237-240
    • /
    • 2002
  • Fiberglass - reinforced plastic (FRP) can have high breakdown puncture strength and has high mechanical strength. So the research of its dielectric properties have been conducted in liquid nitrogen(L$N_{2}$). In this study, we discussed the characteristics of surface flashover on FRP in L$N_{2}$ for applying it to spacer of a superconducting power equipment. We distinguished four types of surface flashover along solid insulator with arrangement of electrodes and tested the surface flashover voltage of each types of electrode arrangement. The type of a electrode set at the back of the insulator showed the worst dielectric property.

  • PDF

저항형 고온초전도 한류기용 절연체의 절연 특성 (Breakdown Characteristics of Insulators for a Resistor Type HTS Fault Current Limiter)

  • 백승명;류엔반둥;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.48-52
    • /
    • 2004
  • Breakdown characteristics of insulator-liquid nitrogen ($LN_2$) composite insulation for resistor type High $T_c$/ superconducting fault current limiter (HTSFCL) under ac and impulse voltage in $LN_2$ has been studied using model electrode systems. Electrodes for model electrode systems were made of SUS 304 contacted fiberglass reinforced plastic (FRP) and Au coated sapphire. The breakdown characteristics of model electrode systems were investigated experimentally for FRP thickness ranging from 1 mm to 5 mm. surface distance ranging from 2.5 mm to 7 mm and electrode gap ranging from 1 to 5 mm. The experimental data suggested that the breakdown voltage of model electrode systems in $LN_2$ is highly dependent on the surface distance, electrode gap as well as on the FRP thickness. Also, we had observed discharge traces and puncture due to high-voltage 60-Hz AC stress.