• Title/Summary/Keyword: fiber optical sensors

Search Result 372, Processing Time 0.024 seconds

High Sensitive Fiber Optic Temperature Sensor Based on a Side-polished Single-mode Fiber Coupled to a Tapered Multimode Overlay Waveguide

  • Prerana, Prerana;Varshney, Ravendra Kumar;Pal, Bishnu Pada;Nagaraju, Bezwada
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.337-341
    • /
    • 2010
  • A high sensitivity fiber optic temperature sensor based on a side-polished fiber (SPF) coupled to a tapered multimode overlay waveguide (MMOW) is proposed and studied. Both tapered and non-tapered MMOW were considered to study the effect of tapering of MMOW on the characteristics of the device and to investigate the criticality of the uniformity of the multimode overlay waveguide over the SPF. Present study shows that tapering of the MMOW can be used to tune the desired wavelength range without any loss in the sensitivity. Sensitivity up to 9 nm/$^{\circ}C$ within the temperature range of 25 to $100^{\circ}C$ can be achieved with the proposed sensor, almost 6 times higher compared even to state-of-the-art high-sensitivity grating-based fiber optic temperature sensors.

A Study on the Tank Liquid-Level Monitoring Sensor Systems for Large Scaled Vessels (대형선박의 액체 탱크용 수위 모니터링 센서 시스템 연구)

  • Sohn, Kyung-Rak;Kim, Jin-Wook;Cho, Seok-Je;Shim, Joon-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.330-335
    • /
    • 2009
  • A fiber-optic liquid level sensor based on bending cantilever beam has been proposed. A fiber Bragg grating(FBG) embedded in the cantilever beam is used to sensing elements. The basic concept is elongation and constriction of the FBG corresponding to the liquid level variation. The best FBG position on the cantilever for obtaining the high sensitivity was 4 cm from the fixing point. When the liquid level moves up and down vertically, the Bragg wavelength is linearly shifted. But, the wavelength sensitivity of the FBG installed on the upper side of cantilever was four times better than that of the FBG equipped in the lateral side due to the difference of unit strain applied to the FBG. Intensity demodulation using the low-cost edge filter is used to interrogate the Bragg wavelength through converting the wavelength signals into the optical intensity ones. Experiment results show that the electrical output is exponentially proportional to the liquid level. But, it should be overcome for applying to the ships.

레이저를 이용한 가연성 물질의 연소폭발

  • U In Seong;V.A Stamatov;Z. Alawabi;K.D. King;D.K Zhang;Choe Seong-Eul;Hwang Myeong-Hwan
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2001.11a
    • /
    • pp.79-82
    • /
    • 2001
  • The studies of the radiation-induced ignition of combustible atmospheres are of particular importance due to increasing use of optical sensors in industries such as coal mining and petroleum production. Because of the alleged intrinsic safety of such systems, substantial optical power is transmitted through optical fibers in potentially explosive atmospheres. However, there has been little experimental or theoretical research on the safety of optical power delivered by optical fiber systems in combustible atmospheres.(omitted)

  • PDF

GPS and DR Navigation System for Unmanned 9round Vehicle (무인지상차량을 위한 GPS와 DR을 이용한 항법시스템)

  • 박대선;박정훈;지규인
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.75-75
    • /
    • 2000
  • Recently, number of navigation system using GPS and other complementary sensors has been developed to offer high-position accuracy. In this paper, an integration of GPS and Dead-Reckoning, which consists of a fiber optical gyroscope and two high-precision wheel-motor encoders for a unmanned navigation system, is presented. The main objective of this integrated GPS/DR unmanned navigation system is to provide accurate position and heading navigation data continuously for autonomous mobile robot. We propose a method for increasing the accuracy of the estimated position of the mobile robot by its DR sensors, high-precision wheel-motor encoders and a fiber optical gyroscope. We used Kalman filter theory to combine GPS and DR measurements. The performance of GPS/DR navigation system is evaluated.

  • PDF

Measurement of Brillouin Backscattering for Distributed Temperature Sensor Applications

  • Kim, Su-Hwan;Kwon, Hyung-Woo;Kwon, Hyun-Ho;Jang, Hang-Seok;Kim, Jee-Hyun;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.8-13
    • /
    • 2011
  • We present measurements of the Brillouin frequency shift in an optical fiber using a 1550 nm distributed feedback laser diode(DFB-LD) as a light source. By modulating the probe light with an electro-optic modulator, we confirm the stimulated Brillouin gain spectrum(BGS) and spontaneous BGS using the coherent detection method. We also confirm the applicability of the technique to distributed temperature sensors that measure the change in Brillouin frequency shift due to temperature variations.

The Method of Measurement Signal Processing of Biosensor Based on Optical Fiber Using Reflected Localized Surface Plasmon Resonance (반사된 국소화 표면 플라즈몬 공명 신호를 이용한 광섬유기반 바이오센서의 측정 신호처리 방법)

  • Jeong, Hyeon-Ho;Lee, Seung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.107-113
    • /
    • 2011
  • LSPR(Localized Surface Plasmon Resonance) sensor measures the refractive index change on the sensor surface. The detection of biological reaction with the unknown refractive index needs to be converted into the signal sensitivity for the refractive index change for comparison with other measurements. To find the signal sensitivity, the three steps of signal processing are proposed, which are signal modeling, signal calibration and signal normalization of LSPR sensor. The detected signal of biotin-streptavidin interaction has been converted into unit of [RU](Resonance Unit) using the proposed method. The converted signal directly can be compared with the other sensors including commercialized one.

Static Behavior of Hollow Cantilever Beam using Multiplexed FBG Sensors (다중화된 FBG 센서를 이용한 중공 내민보의 정적 거동 분석)

  • Lee, Tae-Hee;Kang, Dong-Hoon;Chung, Won-Seok;Mok, Young-Jin
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.593-598
    • /
    • 2009
  • This paper presents a preliminary study to monitor the lateral behavior of pile foundation using multiplexed fiber Bragg grating (FBG) sensors. In the preliminary study, an 1.7 meter long cantilever beam with the shape of square hollow box was fabricated and tested under the static loading. Four FBG sensors were multiplexed in a single optical fiber and installed into the top and bottom of the cantilever beam. The strains are directly measured from FBG sensors followed by curvature calculations based on the plane section assumption. Vertical deflections are then estimated using the regression analyses based on the geometric relationships. It has been found that excellent correlation with conventional sensing system was observed. The success of the test encourages the use of the FBG sensing system as a monitoring system for pile foundations. However, further consideration should be given in the case of the sensor malfunction for the practical purpose.

  • PDF

Strain monitoring of overhead contact line with FBG sensors (FBG 센서를 활용한 가공 전차선의 스트레인 모니터링)

  • Choi, Won-Seok;Ko, Ki-Han;Lee, Kyung-Bok;Park, Young;Cho, Yong-Hyeon
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1227-1230
    • /
    • 2008
  • This paper reports on measurement method for the fiber optic strain monitoring of overhead contact line systems of trains. We used fiber Bragg grating (FBG) sensors to measure the strain variation of overhead contact line. FBG sensors were attached on the contact line and connected to the monitering system with optical fibers. The monitering system with FBG sensors showed very good sensitivity to measuring strain variation and this system could be applied to the overhead contact line of KTX.

  • PDF

Method for Locating Arc-events by Utilizing Transmission Loss of Plastic Optical Fiber (플라스틱 광섬유의 손실 특성을 활용한 아크플래시 위치추적 방법)

  • Jeong, Hoonil;Kim, Young Ho;Kim, Youngwoong;Rho, Byung Sup;Kim, Myoung Jin
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.280-284
    • /
    • 2016
  • For an arc-flash protection system, the selection of arc-flash sensor in implementation is largely dependent on the coverage area and the spatial resolution. Typically, a point sensor is used to accurately measure an arc event within a very narrow region; whereas, a loop or a line sensor can cover several electrical compartment at the same time, but with a poor resolution. In this work, a novel scheme for an arc-flash sensor was developed by making use of the transmission loss of plastic optical fibers (POFs) to cover a broad range with a high spatial resolution. By relating the amplitude ratio of the arc-signals at the ends of the POF with the arc-location, arc events could be located with a resolution of ~5 cm within a spatial range of 10 m, which has not been reported yet.

Development of Fiber Optic BOTDA Sensor for Intrusion Detection (침입탐지를 위한 광섬유 BOTDA 센서의 개발)

  • Kwon, Il-Bum;Kim, Chi-Yeop;Choi, Man-Yong;Yu, Jae-Wang
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.163-172
    • /
    • 2001
  • Fiber optic BOTDA (Brillouin Optical Time Domain Analysis) sensor was developed to be able to detect intrusion effect through several ten kilometer optical fiber. Fiber optic BOTDA sensor was constructed with 1 laser diode and 2 electro-optic modulators. The intrusion detection experiment was peformed by the strain inducing set-up installed on an optical table to simulating an intrusion effect. In the result of this experiment, the intrusion effect was well detected as the distance resolution of 3 m through the fiber length of about 4.81 km during 1.5 seconds.

  • PDF