• Title/Summary/Keyword: fiber concrete

Search Result 2,755, Processing Time 0.026 seconds

Properties of Fire Resistance of Concrete with Contents of Polypropylene Fiber and Specimens Size (폴리프로필렌 섬유의 혼입률 및 부재크기 변화에 따른 콘크리트의 내화 특성)

  • 전선천;황인성;이병열;양성환;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.463-468
    • /
    • 2001
  • A lot of considerations on the spatting by fire of high performance concrete should be taken into for fire resistance of the concrete structures. In this paper, fire resistance of high performance concrete is described using polypropylene fiber, which is known to be contributed to fire resistance. Strength level and member size are varied with. According to test results, spatting by fire takes place more easily, as W/C increases and member size decreases. It shows that concrete containing polypropylene fiber has good effects on preventing spatting by fire. In case high performance concrete does not contain polypropylene fiber, residual strength shows to be decreased remarkably compared :o that of normal concrete. Whereas, in case 0.1% of polypropylene fiber contents, high performance concrete shows higher residual strength than that of normal concrete. As member size is smaller, residual strength shows to be decreased.

  • PDF

Fundamental Properties and Spalling Resistance of High Strength Concrete Containing Hybrid Organic fiber (복합유기섬유를 사용한 고강도 콘크리트의 기초특성 및 폭렬방지)

  • Pei, Chang-Chun;Han, Dong-Yeop;Lee, Jin-Woo;Han, Chang-Pyung;Yang, Seong-Hwan;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.745-748
    • /
    • 2006
  • This study investigates the fundamental properties and examines spalling appearances and residual compressive strength of high strength concrete containing hybrid organic fibers subjected to fire. Test showed that overall, an increase of fiber content decreased the fluidity of concrete, but specimens containing polyvinyl alcoho(PVA)+polypropylene(PP) fiber and nylon(NY)+PP fiber had improved flow. In addition, the air content of all specimens was properly ranged in target value, regardless of fiber content. As for the spalling properties when completed the fire test, control concrete exhibited spalling occurrence due to sudden elevated temperature. However, specimens containing more than 0.1 vol% of PP fiber prevented the spalling, while specimens containing PP+CL and PVA+PP fiber can protected from fire in more than 0.15vol% of the fiber content. Importantly, a specimen containing only 0.05vol% of NY+PP showed the favorable spalling resistance performance.

  • PDF

The optimum steel fiber reinforcement for prestressed concrete containment under internal pressure

  • Zheng, Zhi;Sun, Ye;Pan, Xiaolan;Su, Chunyang;Kong, Jingchang
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2156-2172
    • /
    • 2022
  • This paper investigates the optimum fiber reinforcement for prestressed concrete containment vessels (PCCVs) under internal pressure. To achieve this aim, steel fiber, which is the most widely used fiber type in current engineering applications, is adopted to constitute steel fiber-reinforced concrete (SFRC) to substitute the conventional concrete in the PCCV. The effects of characteristic parameters, 𝜆sf, of the steel fiber affecting significantly the mechanical behavior of the concrete are first taken into account. Partial or complete concrete regions of the PCCV are also considered to be replaced by SFRC to balance the economy and safety. By adopting the ABAQUS software, the ultimate bearing capacity and performance for the fiber-reinforced PCCV are scientifically studied and quantified, and the recommendations for the optimum way of fiber reinforcement are presented.

Confining Effect of CFS on Concrete Compressive Members under Load Actions (하중이력에 따른 콘크리트 압축부재의 CFS 보강효과에 관한 연구)

  • 배주성;김경수;김재욱;고영표
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.705-708
    • /
    • 1999
  • Advanced composite materials such as carbon fiber, aramid, and glass fiber sheet, are widely used recently to strengthening existing reinforced concrete structures. The purpose of this paper was to investigate the mechanical characteristics of concrete compressive members confined with carbon fiber sheet and evaluate the efficiency of the strengthening under load actions. Uniaxal compression tests of concrete compressive members confined with carbon fiber sheet were experimentally used to develop a relationship between the axial stresses and the lateral stresses. The resulting axial and lateral strains were used to determine the confinement effect of concrete compressive members.

  • PDF

Calculation of Crack Width in SFRC Structures (강섬유보강 철근콘크리트구조물에 있어서의 균열폭 계산)

  • 강보순
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.579-584
    • /
    • 2001
  • A method is described for predicting crack with and spacing in Steel Fiber Reinforced Concrete (SFRC). The crack behavior of SFRC influenced by longitudinal reinforcement ratio, volume and type of steel fiber, strength of concrete. It can be observed from experimental results that addition of steel fiber to reinforced concrete beam reduces crack width in serviceability limit states. The proposed method predicts crack widths in cracking stage of the beam. Calculated crack widths obtained for reinforced concrete beams and different volume and type of steel fiber, strength of concrete showed good agreement with experimental results.

  • PDF

A new strength model for the high-performance fiber reinforced concrete

  • Ramadoss, P.;Nagamani, K.
    • Computers and Concrete
    • /
    • v.5 no.1
    • /
    • pp.21-36
    • /
    • 2008
  • Steel fiber reinforced concrete is increasingly used day by day in various structural applications. An extensive experimentation was carried out with w/cm ratio ranging from 0.25 to 0.40, and fiber content ranging from zero to1.5 percent by volume with an aspect ratio of 80 and silica fume replacement at 5%, 10% and 15%. The influence of steel fiber content in terms of fiber reinforcing index on the compressive strength of high-performance fiber reinforced concrete (HPFRC) with strength ranging from 45 85 MPa is presented. Based on the test results, equations are proposed using statistical methods to predict 28-day strength of HPFRC effecting the fiber addition in terms of fiber reinforcing index. A strength model proposed by modifying the mix design procedure, can utilize the optimum water content and efficiency factor of pozzolan. To examine the validity of the proposed strength model, the experimental results were compared with the values predicted by the model and the absolute variation obtained was within 5 percent.

Fire resistance of high strength fiber reinforced concrete filled box columns

  • Tang, Chao-Wei
    • Steel and Composite Structures
    • /
    • v.23 no.5
    • /
    • pp.611-621
    • /
    • 2017
  • This paper presents an investigation on the fire resistance of high strength fiber reinforced concrete filled box columns (CFBCs) under combined temperature and loading. Two groups of full-size specimens were fabricated. The control group was a steel box filled with high-strength concrete (HSC), while the experimental group consisted of a steel box filled with high strength fiber concrete (HFC) and two steel boxes filled with fiber reinforced concrete. Prior to fire test, a constant compressive load (i.e., load level for fire design) was applied to the column specimens. Thermal load was then applied on the column specimens in form of ISO 834 standard fire curve in a large-scale laboratory furnace until the set experiment termination condition was reached. The test results show that filling fiber concrete can improve the fire resistance of CFBC. Moreover, the configuration of longitudinal reinforcements and transverse stirrups can significantly improve the fire resistance of CFBCs.

Evaluation of Stress-Strain Relationship and Elastic Modulus Equation of Steel Fiber Reinforced High-Strength Concrete (강섬유보강 고강도콘크리트의 응력-변형률 곡선 및 탄성계수 추정식 평가)

  • 장동일;손영현;조광현;김광일
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.2
    • /
    • pp.13-20
    • /
    • 2000
  • In this study, the compression test of steel fiber reinforced high-strength concrete have been performed with varying strengths and volume factions of steel fiber. Three types of matrices including low strength concrete( c'=30 MPa), medium strength concrete( c'=50 MPa), and high strength concrete( c'=70 MPa) were selected. Five types of fiber fractions were studied including 0.0%, 0.5%, 0.75%, 1.0%, and 1.5% by volume. From the results of the compressive strength test, the post-peak characteristics of the stress-strain relationship were investigated, and the existing equations to predict the elastic modulus were experimentally evaluated.

A Study of the Characteristic Changes of Self-Compacting Concrete with mixing shifted contents of Steel Fibers (섬유 변화량에 따른 고유동 자기충전 콘크리트의 특성변화에 관한 연구)

  • Lee, Keun-Su;Choi, Yeol;Lee, Jae-Ik;Jung, Woong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.243-244
    • /
    • 2009
  • Fibers reinforced concrete(FRC) has abilities to make up for brittleness fracture as one of the material characteristics of concrete. However, being mixed with steed fibers in concrete mixes could set off a "Fiber Ball". The Fiber ball formation could be one of the main reasons to decrease the quality of Fibers reinforced concrete. In order to eliminate the fiber ball formation and improve the deficient flowablitiy, The necessity of research for fiber reinforced self-compacting concrete(FRC-SCC) should be raised.

  • PDF

Statistical methods of investigation on the compressive strength of high-performance steel fiber reinforced concrete

  • Ramadoss, P.;Nagamani, K.
    • Computers and Concrete
    • /
    • v.9 no.2
    • /
    • pp.153-169
    • /
    • 2012
  • The contribution of steel fibers on the 28-day compressive strength of high-performance steel fiber reinforced concrete was investigated, is presented. An extensive experimentation was carried out over water-cementitious materials (w/cm) ratios ranging from 0.25 to 0.40, with silica fume-cementitious materials ratios from 0.05 to 0.15, and fiber volume fractions ($V_f$= 0.0, 0.5, 1.0 and 1.5%) with the aspect ratios of 80 and 53. Based on the test results of 44 concrete mixes, mathematical model was developed using statistical methods to quantify the effect of fiber content on compressive strength of HPSFRC in terms of fiber reinforcing index. The expression, being developed with strength ratios and not with absolute values of strengths, is independent of specimen parameters and is applicable to wide range of w/cm ratios, and used in the mix design of steel fiber reinforced concrete. The estimated strengths are within ${\pm}3.2%$ of the actual values. The model was tested for the strength results of 14 mixes having fiber aspect ratio of 53. On examining the validity of the proposed model, there exists a good correlation between the predicted values and the experimental values of different researchers. Equation is also proposed for the size effect of the concrete specimens.