• Title/Summary/Keyword: fenton

Search Result 342, Processing Time 0.023 seconds

Antioxidative and Protective Effects of Haeganjeon Extract on Oxidative Damage of Hepatocytes (해간전(解肝煎)의 항산화(抗酸化) 활성(活性) 및 간세포(肝細胞)의 산화적(酸化的) 손상(損傷)에 대한 보호효과(保護效果))

  • Ahn Byung-Tae;Kim Jong-Dae;Moon Jin-Young
    • Herbal Formula Science
    • /
    • v.10 no.2
    • /
    • pp.127-141
    • /
    • 2002
  • Objectives: Haeganjeon(HGJ) has been used for the treatment of liver disease in traditional medicine. The present study was carried out to evaluate the antioxidant and protective effects of HGJ extract on oxidative damage of hepatocytes by tert-butyl hydroperoxide(t-BHP). Methods: In the linoleic acid water-alcohol system, the levels of lipid peroxide(LPO) were determined by TBA method. The scavenging effect of HGJ on ${\alpha},{\alpha}-diphenyl-{\beta}-picrylhydrazyl$(DPPH) radical was determined according to the method of Hatano. In the Fenton system(ferrous ion reaction with hydrogen peroxide), the levels of hydroxyl radical induced LPO in rat liver homogenate were determined according to the method of TBA. Inhibitory effect of HGJ on superoxide generation was measured by xanthine-xanthine oxidase system. In order to evaluate antioxidative activity of HGJ in the liver cell, cultured normal rat liver cells(Ac2F) were prepared and incubated with or without HGJ. After 18hr, cells placed in DMEM medium without serum, and then incubated with 1mM tert-butyl hydroperoxide(t-BHP) for 2hrs. Viable cells were detected by MTT assay. Conclusions: In the linoleic acid autoxidation system, HGJ extract significantly inhibited the time course of the lipid peroxidation. These effects were similar to those of BHA HGJ extracts showed about 70% scavenging effect on DPPH radical. And HGJ extract inhibited the lipid peroxide formation in rat liver homogenate induced by hydroxyl radical derived from Fenton system. In addition, HGJ extract protected the cell death induced by t-BHP and significantly increased cell viability in the normal rat liver cell. These result indicated that HGJ extract might playa protective role against oxidative hepatic cell injury by means of free radical scavenger.

  • PDF

Decrease of Membrane Degradation in PEMFC by Fucoidan (후코이단에 의한 PEMFC 고분자막의 열화 감소)

  • Oh, Sohyung;Kak, Ahyeon;Oh, Sungjun;Lee, Daewoong;Na, Il-Chai;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.58 no.1
    • /
    • pp.59-63
    • /
    • 2020
  • Radical scavenger is used to improve the durability of PEMFC polymer membrane. In this study, we investigated whether fucoidan extracted from seaweed as a radical scavenger prevents electrochemical degradation through Fenton and OCV Holding experiments. Fucoidan has an antioxidant effect, protecting the polymer membrane from hydrogen peroxide and oxygen radicals, reducing the degradation rate to 1/10. Fucoidan has been shown to be more effective than MnO2, which is used as a radical scavenger. In the PEMFC cell, the accelerated durability evaluation method (OCV Holding) showed that fucoidan reduced the hydrogen permeability of the polymer membrane by 12% and enhanced the performance by 29.1% compared to without radical scavenger. And fucoidan was found to be more effective in the cathode side ionomer than the anode side.

pH Dependence on the Degradation of Rhodamine B by Fe-ACF/$TiO_2$ Composites and Effect of Different Fe Precursors (Fe-ACF/$TiO_2$ 복합체에 의한 로다민 B 용액의 분해에 있어서 pH 의존성 및 여러 가지 Fe 전구체의 효과)

  • Zhang, Kan;Oh, Won-Chun
    • Elastomers and Composites
    • /
    • v.44 no.4
    • /
    • pp.408-415
    • /
    • 2009
  • Iron-loaded activated carbon fibers (Fe-ACF) supported titanium dioxide ($TiO_2$) photocatalyst (Fe-ACF/$TiO_2$) was synthesized using a sol-gel method. Three different types of Fe-ACF/$TiO_2$ were obtained by treatment with different precursor of Fe, and characterized using BET, SEM, XRD and EDX analysis. The photocatalytic activity of Fe-ACF/$TiO_2$ was investigated by the degradation of Rhodamine B (Rh.B) solution under UV irradiation. From the experimental results, it was revealed that Fe-ACF/$TiO_2$ composites show considerable photocatalytic ability for the removal of Rh.B by comparing non-treated ACF/$TiO_2$ composites. And photo-Fenton reaction with Fe element was incoordinately influenced due to different precursor of Fe. It clearly indicates that Fe-ACF/$TiO_2$ composites prepared using $FeCl_3$ provided the highest photo-Fenton activity, then, which was affected by pH changes on the degradation of Rh.B.

A Study on the Production of VFAs from Sewage Sludge by Fenton's Oxidation (펜톤 산화에 의한 하수 슬러지로부터 유기산 생성에 관한 연구)

  • Han, Kum-Seok;Nam, Young-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.2
    • /
    • pp.184-190
    • /
    • 2005
  • A new VFAs production process from sewage sludge using Fenton's oxidation was investigated. Optimum concentrations of $H_2O_\;and\;Fe^{2+}$ as well as optimum reaction temperature for VFAs production were studied. In the presence of $Fe^{2+}$ as catalyst, the VFAs formation rate increased about 4 times compared to $H_2O_2$ oxidation process without $Fe^{2+}$. Optimum concentrations of $H_2O_2$ and $Fe^{2+}$ were 0.62 M and 0.007 M, respectively. VFAs formation reaction proceeded rapidly within 1 min and VFAs formed degraded partly to acetic acid and $CO_2$, which exhibited series reaction characteristics. Based on the economic aspect, reaction temperature of $25^{\circ}C$ and 10 min of reaction time were thought to be proper reaction conditions. The effect of initial pH in the range of $3{\sim}6.3$ on the VFAs formation was not observed.

Experimental study of degradation and biodegradability of oxytetracycline antibiotic in aqueous solution using Fenton process

  • Zouanti, Mustapha;Bezzina, Mohamed;Dhib, Ramdhane
    • Environmental Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.316-323
    • /
    • 2020
  • The degradation of aqueous oxytetracycline (OTC) from an aqueous solution antibiotic using H2O2/Fe2+ process was studied in one 1 L batch chemical reactor. The extent of OTC degradation (20 mg/L) was investigated from a known initial pH solution, temperature and the type of catalyst (Fe2+, Fe3+) and for various initial concentrations of OTC, H2O2 and Fe2+. The degradation efficiency achieved was found to be very important (90.82% and 90.63%) at initial pH solution of 3 and 4, respectively. However, the type of catalyst and the reaction temperature had a slight impact on the final degradation of OTC. The results showed that the OTC removal increased with increasing initial H2O2 concentration in the range of 70 to 150 mg/L and initial Fe2+ concentrations in the range of 2 to 5 mg/L. The highest degradation efficiency obtained at ambient temperature was 90.95% with initial concentration of OTC of 10 mg/L, H2O2 = 150 mg/L and Fe2+ = 5 mg/L. Moreover, biodegradability improved from 0.04 to 0.36 and chemical oxygen demand degradation was 78.35% after 60 min of treatment. This study proved that Fenton process can be used for pretreatment of wastewater contaminated by OTC before a biological treatment.

Characterization of Fe-ACF/$TiO_2$ composite Photocatalysts Effect Via Degradation of MB Solution (Fe-ACF/$TiO_2$ 복합체의 특성과 MB용액의 분해에서 포토-펜톤 효과)

  • Zhang, Kan;Meng, Ze-Da;Ko, Weon-Bae;Oh, Won-Chun
    • Elastomers and Composites
    • /
    • v.44 no.3
    • /
    • pp.290-298
    • /
    • 2009
  • In this paper, the Fe-activated carbon fiber (ACF)/$TiO_2$ composite catalysts were prepared by a sol-gel method. The synthesized photocatalysts were used for the photo degradation of Methylene blue solution under UV light. From Brunauer-Emmett-Teller measurements (BET) data, it was shown the blocking of the micropores on the surface of ACF by treatment of Fe and Ti compound. As shown in SEM images, the ferric compounds and titanium dioxides were fixed onto the ACF surfaces. The result of X-ray powder diffraction showed that the crystal phase contained a mixing anatase and rutile structure and the 'FeO+$TiO_2$' from the composites. The EDX spectra for the elemental analysis showed the presence of C, O, and Ti with Fe peaks. Degradation activity of MB could be attributed to +OH radicals derived from electron/hole pair's reactions due to photolysis of $TiO_2$ and photo-Fenton effect of Fe.

Mobility of silver nanoparticles (AgNPs) and oxidative degradation of endocrine disrupting chemicals by saturated column experiments (포화컬럼실험에서 산화공정을 적용한 내분비계 장애물질의 제거 및 은나노물질의 거동 연구)

  • Kim, Yejin;Heo, Jiyong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.6
    • /
    • pp.499-505
    • /
    • 2018
  • We applied column experiments to investigate the environmental fate and transport of silver nanoparticles(AgNPs) in fully saturated conditions of porous media. These column experiments were performed to emphasize oxidation method with $H_2O_2$ concentration and acidic conditions. The mobility of AgNPs was decreased with the increasing ionic strength that the surface charge of AgNPs(zeta potential) was neutralized with the presence of positive ions of $Na^+$. Additionally, it was also affected due to that not only more increased aggregated size of AgNPs and surface charge of quartz sand. The decreased breakthrough curves(BTCs) of bisphenol-A(BPA) and $17{\alpha}$-ethynylestradiol(EE2) were removed approximately 35.3 and 40%. This is due to that endocrine disrupting chemicals(EDCs) were removed with the release of $OH{\cdot}$ radicals by the fenton-like mechanisms from acidic and fenton-like reagent presenting. This results considered that higher input AgNPs with acidic conditions is proved to realistic in-situ oxidation method. Overall, it should be emphasized that a set of column experiments employed with adjusting pH and $H_2O_2$ concentration in proved to be effective method having potential ability of in-situ degradation for removing organic contaminants such as BPA and EE2.

Degradation of herbicide paraquat by Fenton reagent and UV light irradiation (Fenton 시약 및 UV 광 조사에 의한 제초제 paraquat의 분해)

  • Kim, Byung-Ha;Ahn, Mi-Youn;Kim, Jang-Eok
    • The Korean Journal of Pesticide Science
    • /
    • v.3 no.3
    • /
    • pp.20-26
    • /
    • 1999
  • This study was to investigate the potential degradation of a herbicide paraquat by Fenton reagents(ferric ion and hydrogen peroxide) under UV light irradiation(365 nm) in an aqueous solution. When $10{\sim}500$ mg/L of paraquat was reacted with either ferric ion or hydrogen peroxide in the dark or under UV light, no degradation was occurred. However, the simultaneous application of both ferric ion(0.8 mM) and hydrogen peroxide(0.140 M) in paraquat solution(500 mg/L) caused dramatic degradation of paraquat both in the dark (approximately 78%) and under UV light(approximately 90%). The reaction approached an equilibrium state in 10 hours. In the dark, when $0.2{\sim}0.8$ mM ferric ion was added, $20{\sim}70%$ paraquat of $10{\sim}500$ mg/L was degraded, regardless of hydrogen peroxide concentrations($0.035{\sim}0.140$ M), while under UV light, 95% of 10 and 100 mg/L paraquat was degraded regardless of ferric ion and hydrogen peroxide concentrations. At paraquat concentration of 200 and 500 mg/L, paraquat degradation increased with increasing ferric ion concentrations as in the dark. However the increase in hydrogen peroxide concentration did not affect the extent of paraquat degradation. The initial reaction rate constants(k) for paraquat degradation ranged from 0.0004 to 0.0314, and 0.0023 to 0.0367 in the dark and under UV light, respectively. The initial reaction rate constant increased in proportion to the increase in ferric ion concentration in both conditions. The half-lives of paraquat degradation(t1/2) were 20 - 1,980 and 19 - 303 minutes in the dark and under UV light, respectively. This study indicates that Fenton reagents under UV light irradiation are more potent than in the dark in terms of herbicide paraquat degradation in an aqueous solution.

  • PDF

The Direct Decomposition of Ion-Exchange Resins by Fenton's Reagent (펜톤시약에 의한 이온교환수지의 직접산화분해)

  • Kim, Kil-Jeong;Shon, Jong-Sik;Ryu, Woo-Seog
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.221-227
    • /
    • 2007
  • Fenton's reagent is applied to directly decompose the ion-exchange resins, IRN-78 and the mixed resin with IRN-77. The newly applied procedures is to dry the resin first and the catalyst solution is completely absorbed into the resin, then a limited dose of $H_2O_2$ is introduced for an effective reaction between the reagents within the resin. As a characteristic on the decomposition of IRN-78, the resin mixture should be heated to $40^{\circ}C$ to induce the initial reaction and lag time is also needed for about 20 minutes until the main reaction occurs. The effectiveness of the decomposition is investigated using $CuSO_4,\;Cu(NO_3)_2\;and\;FeSO_4$ as a catalyst and the decomposition rate is compared depending on the concentration of each catalyst and the amount of $H_2O_2$. The most effective catalyst was found to be $FeSO_4$ for IRN-78 alone and the mixed resin with IRN-77, and $FeSO_4$ showed a special effect that the reaction was initiated without heating and a lag time. Furthermore, the optimum concentration of the catalyst for each resin and the mixed one is suggested in the view point of the amount of $H_2O_2$ needed and the stability of the decomposition reaction.

  • PDF

Effective Methods of Fenton Oxidation for Remediation of Diesel-contaminated Soil (효과적인 펜톤산화처리법을 이용한 경유오염토양 복원에 관한 연구)

  • Lee, Eui-Sang;Kim, Ji-Young;Oh, Se-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2771-2778
    • /
    • 2009
  • This study was performed to solve the problem of the 2nd contamination and excessive treatment cost by determining proper quantity of hydrogen peroxide, iron catalyst, mixing method, and input mode that should be provided when Fenton oxidation (this is mostly applied to small contaminated areas such as service station sites) is applied to the excavated and diesel-contaminated soil. Soil artificially contaminated with 10000mg/kg of diesel was used for the experiment. In the batch test, diesel removal seemed to increase as the concentration of hydrogen peroxide increases. When iron catalyst was added, removal efficiency of diesel was much higher than the time when hydrogen peroxide was added solely. The removal efficiency showed greater when Fe(III) was added compared to Fe(II). Column experiment was executed on the basis of results of the batch test to investigate adequate reagent mixing and input methods. The highest efficiency was acquired in the case of separate input mode. Also, it was found that when inputting Fe(III) iron catalyst and separately inputting hydrogen peroxide after dividing the bundle in the column, removal efficiency was 92.8%, which was 9 times greater than that of the first method, 10.5%, when only hydrogen peroxide was added. Thus, it is expected that if the result of this research is applied to Fenton oxidation for the remediation of soil contaminated by diesel, the problem of the 2nd contamination and excessive treatment charge caused by excessive addition of hydrogen peroxide and iron catalyst could be solved.