• Title/Summary/Keyword: fault interpretation

Search Result 101, Processing Time 0.03 seconds

Gravity Field Interpretation for the Deep Geological Structure Analysis in Pohang-Ulsan, Southeastern Korean Peninsula (한반도 남동부 포항-울산지역 심부 지질구조 분석을 위한 중력장 해석)

  • Sohn, Yujin;Choi, Sungchan;Ryu, In-Chang
    • Economic and Environmental Geology
    • /
    • v.53 no.5
    • /
    • pp.597-608
    • /
    • 2020
  • Even after the Gyeongju earthquake and the Pohang earthquake, hundreds of aftershocks and micro-earthquakes are still occurring in the southeastern part of the Korean Peninsula. These phenomena mean that the stress is constantly working, implying that another huge earthquake may occur in the future. Therefore, the gravity field interpretation method was used to analyze the deep geological structure of the Pohang-Ulsan region in the southeastern Korean Peninsula. First, a gravity survey was performed to collect the insufficient data and to calculate the detailed Bouguer gravity anomaly in the study area. Based on the gravity anomaly data, the location, direction, and maximum depth of deep fault lines were analyzed using the inversion methods "Curvature analysis" and "Euler deconvolution method". As a result, it is interpreted that at least six fault lines(C1~C6) exist in deep depth. The deep fault line C1 is well correlated to the Yeonil Tectonic Line(YTL), suggesting that YTL is extended up to about 4000m deep. The deep fault line C2 consists of several segment faults and well correlated to the fault lines on the surface. Inferred fault lines C3, C4, and C5 have an NW-SE direction, which is parallel to the Ulsan fault. The deep fault line C6 has the direction of NE-SW, and it is interpreted that the eastern boundary fault of Eoil Basin is extended to the deep. Comparing the inferred fault lines with the distribution of micro-earthquakes, the location of the deep fault line C1 is well correlated to the hypocenter of micro-earthquakes. This implies that faults in deep depth are related to the recent earthquakes in the southeastern Korean Peninsula.

The Alluvial Fan Surface Deformation of the Northern Part of the Ulsan(Bulguksa) Active Fault System in the Southeastern Korea

  • Yoon, Soon-Ock;Hwang, Sang-Il
    • The Korean Journal of Quaternary Research
    • /
    • v.18 no.2 s.23
    • /
    • pp.5-16
    • /
    • 2004
  • The geomorphic deformation of the alluvial fans by tectonic movement was investigated along the lineaments of the northem part of the Ulsan(Bulguksa) fault system. Based on the aerial photographs interpretation and field surveys Ulsan fault system was identified as an active reverse fault which has displaced the Quatemary fan deposits. Buguksa fault system strikes for the direction of NW-SE and N-S. These two lineaments of active fault are crossing at Jinty village in Gyeongju city and the fault plane forms here almost vertical dip. The lateral pressures from the two directions have possibly influenced on the formation of the vertical dip at jinty villagy. It should be resulted from that the two pressures responsible for the active reverse fault at which the one with the NW-SE strike thrusts the hanging wall of Tohamsan block southwestward and the other pressure with the N-S strike thrusts it westward over the foot wall of the fan deposits. The marine oxygen isotope stage 8(0.30-0.25 Ma. BP) and stage 6(0.20-0.14 Ma. BP) are presumed to be the ages of high and middle surfaces of the alluvial fan, repectively. The vertical displacements on the high surfaces along the Bulguksa fault system are about 1.05 m at Ha-Dong, 9.5-10.5 m at Jinhyun-Dong, and about 10 m high at Jinty village. And the vertical displacement on the middle surface was measured about 6 m high at Ha-Dong. The average slip rate of vertical displacements is calculated about 0.03-0.43 mm/y.

  • PDF

Investigation of fault in the Kyungju Kaekok-ri area by 2-D Electrical Resistivity Survey (2차원 전기비저항 탐사를 이용한 경주 개곡리 지역의 단층조사)

  • Lee, Chi-Seop;Kim, Hee-Joon;Kong, Young-Sae;Lee, Jung-Mo;Chang, Tae-Woo
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.4
    • /
    • pp.124-132
    • /
    • 2001
  • Electrical resistivity survey has been conducted for delineating geological fault structure in Kaekok-ri near Kyungju. In general, electrical resistivity survey has an advantage of searching buried faults and its traces compared with other geophysical survey methods. Distribution of electrical conductivity in the ground is influenced by the ratio of pores, groundwater and clay minerals. These properties are evidenced indirectly to explain for weathering condition, faults and fracture Bones. Thus the electrical resistivity survey can be an effective method to find buried faults. We have carried out two dimensional (2-D) interpretation by means of smoothness-constrained least-squares and finite element method. Field data used in this paper was acquired at Kaekok-ri, Wuedong-eup, Kyungju-si, where is Ulsan Fault and is close to the region in which debatable quaternary fault traces were found recently. The dipole-dipole array resistivity survey which could show the 2-D subsurface electrical resistivity structure, was carried out in the area with three lines. The results showed good property of fault, fracture zone and fault traces which we estimated were congruous with the results. Through this study, 2-D electrical resistivity survey interpretation for fault is useful to apply.

  • PDF

Application of geophysical methods to determine the extent of the Dongrae Fault in the Oedong-eup area, Gyeongju City (경주시 외동읍 구어리 일대 동래단층 연장성 확인을 위한 물리탐사 적용)

  • Hwang, Hak-Soo;Hamm, Se-Yeong;Lee, Cheol-Woo;Lee, Chung-Mo;Kim, Sung Wook
    • The Journal of Engineering Geology
    • /
    • v.27 no.3
    • /
    • pp.207-215
    • /
    • 2017
  • The northern extension of the Dongrae Fault is inferred to transect the Ulsan Fault in the Gueo-ri area, Oedong-eup, ~15 km SE of Gyeongju City, Gyeongbuk province, S Korea. We conducted geological and geophysical (magnetic, electrical resistivity, and frequency domain electromagnetic) surveys to identify the extent and orientation of the Dongrae Fault in this region. Through joint interpretation of the geological and geophysical data sets, we confirm the presence of the Dongrae Fault and determine its strike ($N14^{\circ}E$). The Dongrae Fault is thought to cross the Ulsan Fault near Ipsil Bridge in the Gwangeo-ri area. Geophysical surveying revealed a fault damage zone that widens to the south, with a typical width of >200 m. Geological field surveys did not delineate the geometry of the Dongrae Fault because alluvial deposits overlie the fault in this area.

Fault Analysis of Semiconductor Device (반도체 장치의 결함해석)

  • Park, S.J.;Choi, S.B.;Oh, C.S.
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.192-197
    • /
    • 2016
  • We have surveyed on technical method of fault analysis of semiconductor device. Fault analysis of semiconductor should first be found the places of fault spots. For this process they are generally used the testers; EB(emission beam tester), EM(emission microscope), OBIRCH(optical beam induced resistance change method) and LVP(laser voltage probing) etc. Therefore we have described about physical interpretation and technical method in using scanning electron microscope, transmission electron microscope, focused ion beam tester and Nano prober.

Improvements in Patch-Based Machine Learning for Analyzing Three-Dimensional Seismic Sequence Data (3차원 탄성파자료의 층서구분을 위한 패치기반 기계학습 방법의 개선)

  • Lee, Donguk;Moon, Hye-Jin;Kim, Chung-Ho;Moon, Seonghoon;Lee, Su Hwan;Jou, Hyeong-Tae
    • Geophysics and Geophysical Exploration
    • /
    • v.25 no.2
    • /
    • pp.59-70
    • /
    • 2022
  • Recent studies demonstrate that machine learning has expanded in the field of seismic interpretation. Many convolutional neural networks have been developed for seismic sequence identification, which is important for seismic interpretation. However, expense and time limitations indicate that there is insufficient data available to provide a sufficient dataset to train supervised machine learning programs to identify seismic sequences. In this study, patch division and data augmentation are applied to mitigate this lack of data. Furthermore, to obtain spatial information that could be lost during patch division, an artificial channel is added to the original data to indicate depth. Seismic sequence identification is performed using a U-Net network and the Netherlands F3 block dataset from the dGB Open Seismic Repository, which offers datasets for machine learning, and the predicted results are evaluated. The results show that patch-based U-Net seismic sequence identification is improved by data augmentation and the addition of an artificial channel.

Development of Management Software for Transformers Based on Artificial Intelligent Analysis Technology of Dissolved Gases in Oil (지능형 유중가스 분석기술 기반 유입식 변압기 전산관리 프로그램 개발)

  • Sun Jong-Ho;Han Sang-Bo;Kang Dong-Sik;Kim Kwang-Hwa
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.12
    • /
    • pp.578-584
    • /
    • 2005
  • This paper describes development of management software for transformers based on artificial intelligent analysis technology of dissolved gases in oil. Fault interpretation using the artificial intelligent analysis is performed by the artificial neural network and a rule based on the analysis of dissolved gases. The used gases are acetylene($C_{2}H_{2}$), hydrogen($H_2$), ethylene($C_{2}H_{4}$), methane($CH_4$), ethane($C_{2}H_{6}$), carbon monoxide(CO) and carbon dioxide($CO_2$). This software is mainly composed of gases input, fault's causes, expected fault's phenomena in detail, the decision on maintenance as well as report and gas trend windows. It is indicated that this is very powerful software for the efficient management of oil-immersed transformers using data analysis of gas components.

Seismic response characteristics of the hypothetical subsea tunnel in the fault zone with various material properties (다양한 물성의 단층대를 통과하는 가상해저터널의 지진 시 응답 특성)

  • Jang, Dong In;Kwak, Chang-Won;Park, Inn-Joon;Kim, Chang-Yong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1061-1071
    • /
    • 2018
  • A subsea tunnel, being a super-sized underground structure must ensure safety at the time of earthquake, as well as at ordinary times. At the time of earthquake, in particular, of a subsea tunnel, a variety of response behaviors are induced owing to relative rigidity to the surrounding ground, or difference of displacement, so that the behavior characteristics can be hardly anticipated. The investigation aims to understand the behavior characteristics switched by earthquake of an imaginary subsea tunnel which passes through a fault zone having different physical properties from those of the surrounding ground. In order to achieve the aim, dynamic response behaviors of a subsea tunnel which passes through a fault zone were observed by means of indoor experiments. For the sake of improved earthquake resistance, a shape of subsea tunnel to which flexible segments have been applied was considered. Afterward, it is believed that a D/B can be established through 3-dimensional earthquake resistance interpretation of various grounds, on the basis of verified results from the experiments and interpretations under various conditions. The present investigation performed 1 g shaking table test in order to verify the result of 3-dimensional earthquake resistance interpretation. A model considering the similitude (1:100) of a scale-down model test was manufactured, and tests for three (3) Cases were carried out. Incident seismic wave was introduced by artificial seismic wave having both long-period and short-period earthquake properties in the horizontal direction which is rectangular to the processing direction of the tunnel, so that a fault zone was modeled. For numerical analysis, elastic modulus of the fault zone was assumed 1/5 value of the modulus of individual grounds surround the tunnel, in order to simulate a fault zone. Resultantly, reduced acceleration was confirmed with increase of physical properties of the fault zone, and the result from the shaking table test showed the same tendency as the result from 3-dimensional interpretation.

Near-surface geophysical studies in the Ulsan Fault Zone of Korea (한국 울산단층대에서의 천부지구물리 연구)

  • Kim, Ki-Young;Kim, Dong-Hoon;Lee, So-Young
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.1
    • /
    • pp.78-84
    • /
    • 2008
  • Recent earthquakes near nuclear power plants in Korea have triggered public concerns about possible seismicity of the Ulsan Fault Zone in the south-eastern part of the Korean peninsula. To reveal subsurface structures of this fault zone, we conducted high-resolution seismic refraction and reflection surveys, and closely spaced gravity measurements in the Dongchon River valley north of Ulsan, Korea. Here alluvium covers the north-south trending fault zone in a 1-km wide valley. Both source points and receivers were spaced at 5-m intervals for the 24-channel seismic refraction and reflection methods, along two profiles of 835 m and 415 m length. Gravity data were also measured along these profiles at 131 stations using a 10-m interval. Synergetic interpretation of seismic refraction, high-resolution seismic reflection, and gravity surveys across the valley indicates that the Ulsan Fault Zone was formed by apparent north-south strike-slip motions during the Cretaceous, and that some faults may have been reactivated by east-west compressional or transpressional stresses during the Tertiary or Quaternary.

컴퓨터 영상처리에 의한 윤활시스템의 상태진단

  • 서영백;박흥식;전태옥;이충엽
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.224-231
    • /
    • 1997
  • Microscopic examination for the morphological estimation of wear debris on the oil-lubrcated moving system is an accepted method for machine condition and fault diagnosis. However wear particle anaysis has not been widely accepted industry because it is dependent on expert interpretation of particle morphology and relies on subjective assessment criteria. This paper was undertaken to estimate the morphology of wear debris on the oil-lubricated movig system by computer image analysis. The wear test was performed under different sliding conditions using a wear test device made in our laboratory and wear testing specimen of the pin-on-disk-type was rubbed in pararline series base oil. In order to describe characteristics of debris of various shape and size, four shape parameters (50% volumetric diameter, aspect, roundness and reflectivity) have been developed and outlined in the paper. A system using such techniques promises to obviate the need for subjective, human interpretation of particle morphology in machine condition monitoring.

  • PDF